Before using the appliance read
these safety instructions.
Keep them nearby for future
reference.
These instructions are valid if the
country symbol appears on the
appliance. If the symbol doesn’t
appear on the appliance, it is
necessary to refer to the
technical instructions which will
provide the necessary
instructions concerning
modication of the appliance to
the conditions of use of the
country.
CAUTION: The use of the gas
cooking appliance results in the
production of heat, moisture
and products of combustion in
the room in which it is installed.
Ensure that the kitchen is well
ventilated especially when the
appliance is in use: keep natural
ventilation holes open or install
a mechanical ventilation device
(mechanical extractor hood).
Prolonged intensive use of the
appliance may call for additional
ventilation, for example opening
of the window, or more eective
ventilation, increasing the level
of mechanical ventilation where
present.
These instructions and the
appliance itself provide
important safety warnings, to be
observed at all times.
The manufacturer declines any
liability for failure to observe
these safety instructions, for
inapropriate use of the
appliance or incorrect setting of
controls.
If the information in this manual
is not followed exactly, a re or
explosion, may result causing
property damage or injury.
SAFETY WARNINGS
Very young (0-3 years) and
young children (3-8 years) shall
be kept away from the appliance
unless continuously supervised.
Children from 8 years old and
above and persons with reduced
physical, sensory or mental
capabilities or lack of experience
and knowledge can use this
appliance only if they are
supervised or have been given
instructions on safe use and
understand the hazards
involved. Children must not play
with the appliance. Cleaning and
user maintenance must not be
carried out by children without
supervision.
WARNING: The appliance and
its accessible parts become hot
during use, children less than 8
year of age shall be kept away
unless continuously supervised.
WARNING: Avoid touching
heating elements or interior
surface - risk of burns.
Never leave the appliance
unattended during food drying.
If the appliance is suitable for
probe usage, only use the
temperature probe
recommended for this oven.
Keep clothes or other ammable
materials away from the
appliance, until all the
components have cooled down
completely.
Overheated oils and fats catch
re easily. Always be vigilant
when cooking food rich in fat,
oil or when adding alcohol (e.g.
rum, cognac, wine) - risk of re.
Use oven gloves to remove pans
and accessories, taking care not
to touch the heating elements.
At the end of cooking, exercise
caution when opening the door,
by letting the hot air or steam
exit gradually before accessing
the appliance.
Do not obstruct hot air vents at
the front of the oven.
PERMITTED USE
CAUTION: The appliance is not
intended to be operated by
means of an external timer or
separate remote controlled
system.
This appliance is solely for
domestic, not professional use.
Do not use the appliance
outdoors.
Do not store explosive or
ammable substances such as
aerosol cans and do not place or
use gasoline or other ammable
materials in or near the
appliance: a re may break out if
the appliance is inadvertently
switched on.
No other use is permitted
(e.g.heating rooms).
INSTALLATION
The appliance must be handled
and installed by two or more
persons. Use protective gloves
to unpack and install the
appliance.
The electrical and gas
connections must comply with
local regulation.
WARNING: Modication of the
appliance and its method of
installation are essential in order
to use the appliance safely and
correctly in all the additional
countries.
Use pressure regulators suitable
for the gas pressure indicated in
the instruction.
Connection with rigid pipe
(copper or steel).
If the gas pressure is dierent
from the recommended
pressure, a suitable pressure
regulator must be tted to the
inlet pipe in accordance with the
current National Regulations
The room must be equipped
with an air extraction system
that expels any combustion
fumes. This may consist of a
hood or an electric fan that
automatically starts each time
the appliance is switched on.
The room must also allow
proper air circulation, as air is
needed for combustion to occur
normally. The ow of air must
not be less than 2 m
of installed power.
The air circulation system may
3
/h per kW
2
take air directly from the outside
by means of a pipe with an inner
cross section of at least 100 cm2;
the opening must not be
vulnerable to any type of
blockages.
The system can also provide the
air needed for combustion
indirectly, i.e. from adjacent
rooms tted with air circulation
tubes as described above.
However, these rooms must not
be communal rooms, bedrooms
or rooms that may present a re
hazard.
Liquid petroleum gas sinks to
the oor as it is heavier than air.
Therefore, rooms containing
LPG cylinders must also be
equipped with vents to allow
gas to escape in the event of a
leak. As a result LPG cylinders,
whether partially or completely
full, must not be installed or
stored in rooms or storage areas
that are below ground level
(cellars, etc.). It is advisable to
keep only the cylinder being
used in the room, positioned so
that it is not subject to heat
produced by external sources
(ovens, replaces, stoves, etc. )
which could raise the
temperature of the cylinder
above 50°C.
Use an appropriate cabinet to
ensure that the appliance
operates properly: to install the
oven under the counter (see
diagram) or in a kitchen unit, the
cabinet must have the
dimensions as the picture.
To ensure adequate ventilation,
the back panel of the cabinet
must be removed. It is advisable
to install the oven so that it rests
on two strips of wood, or on a
completely at surface with an
opening of at least 45 x 560 mm
as the picure.
GAS CONNECTION
WARNING: Prior to installation,
ensure that the local distribution
conditions (nature of gas and
gas pressure) and the
adjustment of the appliance are
compatible.
Check that the pressure of the
gas supply is consistent with the
values indicated in Table 1
(“Burner and nozzle
specications”).
WARNING: The adjustment
condictions for this appliance
are stated on the lable (or data
plate).
WARNING: This appliance is not
connected to a combustion
products evacuation device. It
shall be installed and connected
in accordance with current
installation regulations.
Particulat attention shall be
given to the relevant
requirements regarding
ventilation.
If the appliances is connected to
liquid gas, the regulation screw
must be fastned as tightly as
possible.
IMPORTANT: When gas cylinder
is adopted, the gas cylinder or
gas container must be properly
settled (vertical orientation).
WARNING: This operation must
be perfomed by a qualied
technician.
Use only exible or rigid metal
hose for gas connection.
Connection with a rigid pipe
(copper or steel)
Connection to the gas system
must be carried out in such a
way as not to place any strain of
any kind on the appliance.
There is an adjustable L-shaped
pipe tting on the appliance
supply ramp and this is tted
with a seal in order to prevent
leaks. The seal must always be
replaced after rotating the pipe
tting (the seal is provided with
the appliance).
The gas supply pipe tting is a
threaded 1/2 gas cylindrical
male attachment.
Connecting a exible jointless
stainless steel pipe to a
threaded attachment
The gas supply pipe tting is a
threaded 1/2 gas cylindrical
male attachment. These pipes
must be installed so that they
are never longer than 2000 mm
when fully extended. Once
EN
connection has been carried
out, make sure that the exible
metal pipe does not touch any
moving parts and is not
compressed.
Only use pipes and seals that
comply with current National
regulations.
IMPORTANT: If a staineless steel
hose is used, it must be installed
so as not touch any mobile part
of the furniture (e.g.drawer). It
must pass thorugh an area
where there are no obstructions
and where it is possible to
inspect it on all its length.
The appliance should be
connected to the main gas
supply or to gas cylinder in
compliance with the current
National regulations. Before
carry out the connection, make
sure that the appliance is
compatible with the gas supply
you wish to use. If this is not the
case, follow the instructions
indicated in the paragraph
“Adapting to dierent types of
gas”.
After connection to the gas
supply, check for leaks with
soapy water. Light up the
burners and turn the knobs from
max position to minimum
position to check ame stability.
REPLACING THE INJECTORS
For the Oven , lower side
Remove the burner cover plate.
Remove the screw securing the
oven burner and withdraw the
burner from the support
together with the heat sensor
and the ignition spark plug.
3
Remove the nozzle using a 7
mm socket wrench.
Screw the new injector in fully
(diameter in hundredths of
millimetre stamped on the
injector), taking care not to cross
the thread.
Replace the burner reversing the
operations in step 2 above.
Replace the cover plate.
Adjusting the minimum ame.
Before installing the oven,
remember to ax the gas
calibration plate supplied with
the injectors in such a way that it
covers the existing information
relating to gas calibration.
For the Grill, upper side
Remove the burner screw
located at top front of the oven
cavity.
Remove the burner together
with its heat elements.
Remove the injector using the 7
mm socket wrench.
Fully tighten the new injector
which must be of the diameter
indicated in the table in the
chart table.
Put back the burner and secure
it with the screw.
Installation and repairs must be
carried out by a qualied
technician, in compliance with
the manufacturer’s instructions
and local safety regulations. Do
not repair or replace any part of
the appliance unless specically
stated in the user manual.
Children should not perform
installation operations. Keep
children away during
installation. Keep the packaging
materials (plastic bags,
polystyrene parts, etc.) out of
reach of children, during and
after the installation.
After unpacking the appliance,
make sure that it has not been
damaged during transport. In
the event of problems, contact
the dealer or your nearest Aftersales Service.
The appliance must be
disconnected from the power
supply before any installation
operation.
During installation, make sure
the appliance does not damage
the power cable.
Only activate the appliance
when the installation has been
completed.
After installation, the bottom of
the appliance must no longer be
accessible.
Carry out all cabinet cutting
works before tting the
appliance in the furniture and
carefully remove all wood chips
and sawdust.
Do not obstruct the minimum
gap between the worktop and
the upper edge of the oven.
Only remove the oven from its
polystyrene foam base at the
time of installation.
Do not install the appliance
behind a decorative door - Risk
of re.
ELECTRICAL WARNINGS
For installation to comply with
current safety regulations, an
omnipolar switch with minimum
contact gap of 3 mm is required
and the appliance must be
earthed.
If the power cable is damaged,
replace with an identical one.
The power cable must only be
replaced by a qualied
technician in compliance with
the manufacturer instruction
and current safety regulations.
Contact an authorized service
center.
It must be possible to
disconnect the appliance from
the power supply by unplugging
it if plug is accessible, or by
means of an accessible multipole switch installed upstream
of the socket in conformity with
national electrical safety
standards.
The rating plate is on the front
edge of the oven (visible when
the door is open).
In case of replacement of power
cable, contact an authorized
service center.
IMPORTANT: The data rilevant
to the voltage an power
absortions are indicated on the
rating plate
If the tted plug is not suitable
for your socket outlet, contact a
4
qualied technician.
The power cable must be long
enough to connect the
appliance, once tted in its
housing, to the main power
supply. Do not pull the power
supply cable.
Do not use extension leads,
multiple sockets or adapters.
Do not operate this appliance if
it has a damaged mains cord or
plug, if it is not working
properly, or if it has been
damaged or dropped. Keep the
cord away from hot surfaces.
The electrical components must
not be accessible to the user
after installation.
Do not touch the appliance with
any wet part of the body and do
not operate it when barefoot.
The power cable must be long
enough to connect the
appliance, once tted in its
housing, to the main power
supply. Do not pull the power
supply cable.
The earthing of this appliance is
compulsory by law.
The cable must be checked
regularly and replaced by
authorised tschnicians in
compliance with the
manufacturer instruction and
current safety regulations.
CORRECT USE
Should you experience diculty
in turning the burners knobs,
please contact After Sales
Service for replacement of the
burner tap if found to be faulty.
The openings use for the
ventilation and dispersion of
heat must never be covered.
When you place the rack inside,
make sure that the stop is
directed upwards and in the
back of the cavity.
CLEANING AND
MAINTENANCE
Never use steam cleaning
equipment or pressure cleaners
on the appliance.
WARNING: Ensure that the
EN
appliance is switched o before
replacing the lamp to avoid the
possibility of electric shock.
Do not use harsh abrasive
cleaners or sharp metal scrapers
to clean the appliance door glass
since they can scratch the
surface, which may result in
shattering of the glass.
Wear protective gloves for
cleaning and maintenance.
The appliance must be
disconnected from the power
supply before any maintenance
operation.
Ensure the appliance is cooled
down before carrying out any
cleaning or maintenance
operation.
To avoid damaging the electric
ignition device, do not use it
when the burners are not in
their housing.
Never use steam cleaning
equipment or pressure cleaners
on the appliance.
Wear protective gloves for
cleaning and maintenance.
GF3 43 NG IX A
INJECTOR TABLE
Algeria,
Tunisia, Egypt,
Lybia
BurnerType of gas
OvenG202017/252.5238 l/h113
G30/G310.4228-30/3725/452.5182 g/h76
GrillG202017/252.2210 l/h112
G30/G3128-30/3725/452.2160 g/h75
By-pass
(mm)
Pressure
(mbar)
min.P /
max.P
(mbar)
Eat Input
(kW)
Consumption
Injectors
Ø
5
Loading...