American Power Conversion AP7902, AP7911 User Manual

Switched Rack
Power Distribution Unit
AP7902
AP7911
Installation and
Quick Start
Contents
Product Description and Inventory . . . . . . . . . . . . . . . . . . . . . . 1
AP7902 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
AP7911 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Additional documentation . . . . . . . . . . . . . . . . . . . . . . . . . 2
Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Receiving inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Please recycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
InfraStruXure-certified . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
How to Install the Rack PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Attach the cord retention tray . . . . . . . . . . . . . . . . . . . . . . . 3
Additional cord retention tray (optional) . . . . . . . . . . . . . . . . 3
Attach cords to the tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Mounting options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Display interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Quick Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
TCP/IP configuration methods . . . . . . . . . . . . . . . . . . . . . . . 7
APC Management Card Wizard . . . . . . . . . . . . . . . . . . . . . . 8
BOOTP & DHCP configuration . . . . . . . . . . . . . . . . . . . . . . . 8
Local access to the control console . . . . . . . . . . . . . . . . . . . 11
Remote access to the control console . . . . . . . . . . . . . . . . . 11
Control console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
How to Access a Configured Rack PDU . . . . . . . . . . . . . . . . . . 13
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Web interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Telnet/SSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
FTP/SCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
How to Recover From a Lost Password . . . . . . . . . . . . . . . . . . 16
How to Download Firmware Updates . . . . . . . . . . . . . . . . . . . 17
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
AP7902/AP7911 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Warranty and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Limited warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Warranty limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Obtaining service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Life-Support Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
General policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Examples of life-support devices . . . . . . . . . . . . . . . . . . . . 20
ii Switched Rack PDU Installation and Quick Start

Product Description and Inventory

AP7902 and AP7911 are Switched Rack Power Distribution Units (Rack PDUs) that distribute power to devices in the rack. The user can turn on, turn off, or recycle power back to the individually controlled outlets. The Rack PDUs also have a sensor that measures the current being used by the Rack PDUs and their attached devices. The Rack PDUs can be monitored through Web, Telnet, SNMP, or InfraStruXure Manager interfaces.

AP7902

AP7911

Bank 1 — Eight NEMA 5-20 outlets
20A circuit breaker for Bank 1
20A circuit breaker for Bank 2
Display interface
Bank 2 — Eight NEMA 5-20 outlets
NEMA L5-30 plug with a 12-foot power cord
Bank 1 — Eight IEC 320 C13 outlets
15A circuit breaker for Bank 1
15A circuit breaker for Bank 2
Display interface
Bank 2 — Eight IEC 320 C13 outlets
NEMA L6-30 plug with a 12-foot power cord
Switched Rack PDU Installation and Quick Start 1
Product Description and Inventory

Additional documentation

Inventory

The Rack PDU User’s Guide and the Rack PDU Addendum are available on the supplied CD and on the APC Web site: www.apc.com.
The User’s Guide (.\doc\eng\usrguide.pdf) contains additional information about the following topics related to the Rack PDU:
• Management interfaces
• User accounts
• Customizing setup
•Security
The Addendum (.\doc\eng\addendum.pdf) contains additional information about the following topics:
• The Management Card Wizard
• Configuration utilities
• File transfers
The Rack PDU is shipped with the following items:
Quantity Item

Receiving inspection

Please recycle

1 Configuration cable (940-0144)
1 Cord retention tray (with 4 flat-head screws and
16 wire ties)
2 Mounting brackets (with 8 flat-head screws)
4 Rubber feet
1 APC Switched Rack PDU Utility CD
1 Warranty registration card
Inspect the package and contents for shipping damage, and make sure that all parts were sent. Report any damage immediately to the shipping agent, and report missing contents, damage, or other problems immediately to APC or your APC reseller.
The shipping materials are recyclable. Please save them for later use, or dispose of them appropriately.

InfraStruXure-certified

This product is certified for use in InfraStruXure systems. The Configuration section, beginning on page 7, does not apply to Rack PDUs that are part of InfraStruXure systems managed by an InfraStruXure Manager.
2 Switched Rack PDU Installation and Quick Start

How to Install the Rack PDU

Installation guidelines

Attach the cord retention tray

• For a Rack PDU installed in an enclosed communications rack, the recommended maximum ambient temperature is 45° C (113º F).
• Install the Rack PDU so that it does not reduce the air flow required for safe operation of the equipment.
• Install the Rack PDU so that there is an even mechanical load.
• Follow the nameplate ratings when connecting equipment to the supply circuit. Avoid overloading the circuits, which could affect over-circuit protection and supply wiring.
• Maintain reliable earthing of the Rack PDU, especially supply­connections that do not directly connect to the branch circuit.
• Install the Rack PDU so that the power plug is accessible to be disconnected for service.
Attach the cord retention tray to the Rack PDU, using four flat-head screws (provided) per tray.

Additional cord retention tray (optional)

Mount an additional cord retention tray to secure cords from the top bank of outlets. Purchase additional tray kits
Note
Attach a second cord retention tray to the PDU, with the cord retainers facing down.
Switched Rack PDU Installation and Quick Start 3
from APC (AP9569).
How to Install the Rack PDU

Attach cords to the tray

Attach a cord to the tray by looping the cord and securing it to the tray, using a wire tie (provided). Cords from both banks of outlets may be secured to the bottom tray, or you may attach an additional tray (shown on the preceding page) to secure cords from the top bank of outlets. Make sure the cords that are attached to the upper tray do not interfere with the operation of the circuit breakers.
Each cord must be secured to the tray so that you can unplug it from the Rack PDU without removing the wire tie.
Note

Mounting options You can install the Rack PDU in one of two ways: flush with the rack, or

recessed to allow the use of the cord retention bracket. To mount the Rack Rack PDU horizontally in a NetShelter
®
or any other standard
EIA-310 rack or enclosure:
1. Attach the mounting brackets to the Rack PDU, using the flat-head
screws (provided).
Some enclosures may require you to recess the Rack PDU so that the back doors of the enclosure will close
Note
when other devices are plugged in to the Rack PDU.
For placement flush-to-rack: use four flat-head screws (provided) for each bracket.