Installation Instructions

SELECTRONIC

®

 

 

 

6065.111

6066.111

6065.521

 

MODEL NUMBERS

DC POWERED PROXIMITY EXPOSED

6065.121

6066.121

6065.525

TOILET FLUSH VALVE

6065.161

6066.161

6065.561

1.1, 1.28, 1.6, 1.6/1.1 & 1.28/1.1 GPF

6065.721

6066.721

6065.565

 

 

 

 

6065.761

6066.761

 

 

 

 

 

 

Exposed Flushometer for 1-1/2" Top Spud Bowls

CLOG RESISTANT

• Self-cleaning piston valve prevents clogging and reduces maintenance.

ONE SENSOR FITS ALL

Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.

Range can be adjusted manually or with optional remote control.

Sensor Features Low Battery Indicator.

CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.

Certified to comply with ASME A112.19.2

© 2015 AS America, Inc.

NOTE TO INSTALLER: Please give this manual to the customer after installation.

To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com

For Parts, Service, Warranty or other Assistance,

please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)

(In Toronto Area only: 1-905-306-1093))

© 2015 AS America Inc.

1

M965646 REV. 1.4 (7/15)

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

UNPACKING

All American Standard Products Are Water Tested At Our Factory.

 

Some Residual Water May Remain In The Valve During Shipping.

Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.

1. Installation Instructions

6. Wall Escutcheon

2.

Flush Valve Body Assembly

7. Cover Tube

3. Vacuum Breaker Tube

8.

Sweat Adapter

4. Spud Coupling Nut and Washers

9.

Stop Valve

5.

Spud Flange

 

 

CARE INSTRUCTIONS:

DO: CLEAN THE PRODUCT WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

2

3

4

5

DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.

7

6

8

9

 

 

Instructions

SELECTRONIC®

MODEL NUMBERS

 

DC POWERED PROXIMITY EXPOSED

6065.111

6066.111

6065.521

 

 

TOILET FLUSH VALVE

6065.121

6066.121

6065.525

 

 

1.1, 1.28, 1.6,

6065.161

6066.161

6065.561

 

 

1.6 / 1.1, & 1.28/1.1 GPF

 

 

6065.721

6066.721

6065.565

 

 

 

 

Installation

 

6065.761

6066.761

 

1

Exposed Flushometer

 

 

 

 

for 1-1/2" Top Spud Bowls

 

 

 

 

CLOG RESISTANT

 

 

 

 

 

• Self-cleaning piston valve prevents clogging and reduces maintenance.

 

 

ONE SENSOR FITS ALL

 

 

 

 

 

• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.

 

 

• Range can be adjusted manually or with optional remote control.

 

 

• Sensor Features Low Battery Indicator.

 

 

 

 

CAUTION: Use only American Standard

 

 

 

supplied cable sets. Using non-AS supplied

 

 

 

cables, or cutting, splicing or modifying any

 

 

 

components will void the warranty.

 

 

 

 

Certified to comply with ASME A112.19.2

 

 

 

 

 

© 2015 AS America, Inc.

 

 

 

 

NOTE TO INSTALLER: Please give this manual to the customer after installation.

 

To learn more about American Standard Selectronic® Products visit our website at:www.americanstandard-us.com

 

or e-mail us at: CRTTEAM@americanstandard.com

 

 

 

 

For Parts, Service, Warranty or other Assistance,

 

 

 

 

please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)

 

 

 

 

(In Toronto Area only: 1-905-306-1093)

 

 

2

M965646 REV. 1.4 (7/15)

Roughing-in Dimensions Fig. 1

 

GENERAL DESCRIPTION:

Right or Left Hand Installation

 

SELECTRONIC® PROXIMITY TOILET FLUSH VALVE

See (Section 5) for converting Flush

 

Exposed Flushometer for 1-1/2” Top Spud Fixtures

Valve to Left Hand Installation.

 

 

Exclusive, self cleaning piston-type flush valve with

 

 

 

 

 

 

 

 

proximity operation and manual override. Operates

 

 

 

 

on DC (battery) power. Recommended operating

 

 

 

 

pressure 35 to 80 psi. Can install left or right-handed.

 

 

 

 

Detection Zone can also be adjusted manually, or

 

 

 

FINISHED WALL

with optional remote control.

 

73 mm

 

 

 

 

(2-7/8")

305 mm MÁX.

 

 

 

 

 

 

 

 

(12" MÁX.)

 

 

 

120 mm

 

 

15˚

MANUAL

(4-3/4")

 

 

 

OVERRIDE

 

 

 

 

BUTTON

 

 

 

 

 

 

 

 

DETECTION ZONE

 

 

SUPPLY

 

400mm-800mm

 

 

(1" NPT.)

 

(15-3/4 TO 31-1/2)

 

 

(NPT de 1")

 

 

 

-C-L-

412 mm

 

 

 

 

 

 

292 mm

 

(16-3/16")

 

 

 

108mm-134mm

 

 

(11-1/2")

 

 

 

 

*-C-L-

(4-1/4" TO 5-1/4")

 

 

 

152mm MIN.

 

170 mm MÁX.

 

(6") MIN.

FOR 1-1/2" TOP

 

 

(6-11/16") MÁX.

 

 

SPUD FIXTURES

 

 

 

 

 

 

CAUTION: Use only American Standard supplied

 

 

 

 

transformers and cable sets. Using non-AS supplied

*Note: The Critical Line (-C-L-) on Vacuum

 

cables, or cutting, splicing or modifying any components

Breaker must typically be 6" (152mm) above

 

will void the warranty.

fixture. Consult Codes for details.

 

 

 

RECOMMENDED TOOLS; Fig. 2.

1. Teflon Tape

2.Flat Blade Screwdriver

3.Adjustable Wrench

4.Tape Measure

5.Hacksaw

6.Tubing Cutter

7.File

8.For Sweat Connection; Solder and Torch

9.2.5mm Hex Wrench

10.1.5mm Hex Wrench

Fig. 2

 

 

 

 

1

2

 

 

3

 

4

 

 

 

 

10'

 

 

 

 

 

 

 

 

 

6

 

5

 

 

8

 

7

 

9

10

PRIOR TO INSTALLATION

Note: Prior to installing the Selectronic™Flush

• Flush all water lines prior to operation (See Step 4).

Valve the following items must be installed.

Dirt and debris can cause flush valve to run continuously.

1. Toilet

With the exception of Stop Valve Inlet, DO NOT

2.

Drain line

use pipe sealant or plumbing grease on any

3.

Water supply line

valve component or coupling!

IMPORTANT:

• Protect the chrome or special finish on the Flushometer.

All plumbing and electrical wiring should be

DO NOT USE toothed tools on finished surfaces to install

installed in accordance with applicable codes

or service these valves. Also see “Care and Cleaning”

and regulations.

section of this manual.

• The use of water hammer arrestors is strongly

 

recommended for commercial applications. All piping

• This product contains mechanical and/or electrical

behind the walls should be properly secured and

components that are subject to normal wear. These

fastened.

components should be checked on a regular basis and

• Water supply lines must be sized to provide an

replaced as needed to maintain the valve’s performance.

adequate volume of water for each fixture.

 

3