Installation Instructions
SELECTRONIC |
® |
|
|
|
|
6065.111 |
6066.111 |
6065.521 |
|||
|
MODEL NUMBERS |
||||
DC POWERED PROXIMITY EXPOSED |
6065.121 |
6066.121 |
6065.525 |
||
TOILET FLUSH VALVE |
|||||
6065.161 |
6066.161 |
6065.561 |
|||
1.1, 1.28, 1.6, 1.6/1.1 & 1.28/1.1 GPF |
|||||
6065.721 |
6066.721 |
6065.565 |
|||
|
|
||||
|
|
6065.761 |
6066.761 |
|
|
|
|
|
|
|
Exposed Flushometer for 1-1/2" Top Spud Bowls
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
•Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
•Range can be adjusted manually or with optional remote control.
•Sensor Features Low Battery Indicator.
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Certified to comply with ASME A112.19.2
© 2015 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093))
© 2015 AS America Inc. |
1 |
M965646 REV. 1.4 (7/15) |
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING |
All American Standard Products Are Water Tested At Our Factory. |
|
Some Residual Water May Remain In The Valve During Shipping. |
Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions |
6. Wall Escutcheon |
||
2. |
Flush Valve Body Assembly |
7. Cover Tube |
|
3. Vacuum Breaker Tube |
8. |
Sweat Adapter |
|
4. Spud Coupling Nut and Washers |
9. |
Stop Valve |
|
5. |
Spud Flange |
|
|
CARE INSTRUCTIONS:
DO: CLEAN THE PRODUCT WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
2
3
4
5
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
7
6 |
8 |
|
9 |
||
|
|
Instructions |
SELECTRONIC® |
MODEL NUMBERS |
||
|
DC POWERED PROXIMITY EXPOSED |
6065.111 |
6066.111 |
6065.521 |
|
|
|
TOILET FLUSH VALVE |
6065.121 |
6066.121 |
6065.525 |
|
|
1.1, 1.28, 1.6, |
6065.161 |
6066.161 |
6065.561 |
|
|
1.6 / 1.1, & 1.28/1.1 GPF |
|||
|
|
6065.721 |
6066.721 |
6065.565 |
|
|
|
|
|||
|
Installation |
|
6065.761 |
6066.761 |
|
1 |
Exposed Flushometer |
|
|
|
|
|
for 1-1/2" Top Spud Bowls |
|
|
||
|
|
CLOG RESISTANT |
|
|
|
|
|
• Self-cleaning piston valve prevents clogging and reduces maintenance. |
|||
|
|
ONE SENSOR FITS ALL |
|
|
|
|
|
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves. |
|||
|
|
• Range can be adjusted manually or with optional remote control. |
|||
|
|
• Sensor Features Low Battery Indicator. |
|
|
|
|
|
CAUTION: Use only American Standard |
|
||
|
|
supplied cable sets. Using non-AS supplied |
|
||
|
|
cables, or cutting, splicing or modifying any |
|
||
|
|
components will void the warranty. |
|
|
|
|
|
Certified to comply with ASME A112.19.2 |
|
|
|
|
|
© 2015 AS America, Inc. |
|
|
|
|
NOTE TO INSTALLER: Please give this manual to the customer after installation. |
||||
|
To learn more about American Standard Selectronic® Products visit our website at:www.americanstandard-us.com |
||||
|
or e-mail us at: CRTTEAM@americanstandard.com |
|
|
|
|
|
For Parts, Service, Warranty or other Assistance, |
|
|
|
|
|
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369) |
|
|
||
|
|
(In Toronto Area only: 1-905-306-1093) |
|
|
2 |
M965646 REV. 1.4 (7/15) |
Roughing-in Dimensions Fig. 1 |
|
GENERAL DESCRIPTION: |
||
Right or Left Hand Installation |
|
SELECTRONIC® PROXIMITY TOILET FLUSH VALVE |
||
See (Section 5) for converting Flush |
|
Exposed Flushometer for 1-1/2” Top Spud Fixtures |
||
Valve to Left Hand Installation. |
|
|
Exclusive, self cleaning piston-type flush valve with |
|
|
|
|
|
|
|
|
|
|
proximity operation and manual override. Operates |
|
|
|
|
on DC (battery) power. Recommended operating |
|
|
|
|
pressure 35 to 80 psi. Can install left or right-handed. |
|
|
|
|
Detection Zone can also be adjusted manually, or |
|
|
|
FINISHED WALL |
with optional remote control. |
|
73 mm |
|
|
|
|
(2-7/8") |
305 mm MÁX. |
|
|
|
|
|
|
|
|
|
(12" MÁX.) |
|
|
|
120 mm |
|
|
15˚ |
MANUAL |
(4-3/4") |
|
|
|
OVERRIDE |
|
|
|
|
BUTTON |
|
|
|
|
|
|
|
|
DETECTION ZONE |
|
|
SUPPLY |
|
400mm-800mm |
|
|
(1" NPT.) |
|
(15-3/4 TO 31-1/2) |
|
|
(NPT de 1") |
|
|
|
-C-L- |
412 mm |
|
|
|
|
|
|
|
292 mm |
|
(16-3/16") |
|
|
|
108mm-134mm |
|
|
|
(11-1/2") |
|
|
|
|
|
*-C-L- |
(4-1/4" TO 5-1/4") |
|
|
|
152mm MIN. |
|
170 mm MÁX. |
|
|
(6") MIN. |
FOR 1-1/2" TOP |
||
|
|
(6-11/16") MÁX. |
||
|
|
SPUD FIXTURES |
|
|
|
|
|
|
CAUTION: Use only American Standard supplied |
|
|
|
|
transformers and cable sets. Using non-AS supplied |
*Note: The Critical Line (-C-L-) on Vacuum |
|
cables, or cutting, splicing or modifying any components |
||
Breaker must typically be 6" (152mm) above |
|
will void the warranty. |
||
fixture. Consult Codes for details. |
|
|
|
RECOMMENDED TOOLS; Fig. 2.
1. Teflon Tape
2.Flat Blade Screwdriver
3.Adjustable Wrench
4.Tape Measure
5.Hacksaw
6.Tubing Cutter
7.File
8.For Sweat Connection; Solder and Torch
9.2.5mm Hex Wrench
10.1.5mm Hex Wrench
Fig. 2 |
|
|
|
|
1 |
2 |
|
|
3 |
|
4 |
|
|
|
|
|
10' |
|
|
|
|
|
|
|
|
|
|
|
6 |
|
5 |
|
|
8 |
|
7 |
|
9 |
10 |
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush |
• Flush all water lines prior to operation (See Step 4). |
||
Valve the following items must be installed. |
Dirt and debris can cause flush valve to run continuously. |
||
1. Toilet |
• With the exception of Stop Valve Inlet, DO NOT |
||
2. |
Drain line |
||
use pipe sealant or plumbing grease on any |
|||
3. |
Water supply line |
||
valve component or coupling! |
IMPORTANT: |
• Protect the chrome or special finish on the Flushometer. |
|
• All plumbing and electrical wiring should be |
||
DO NOT USE toothed tools on finished surfaces to install |
||
installed in accordance with applicable codes |
||
or service these valves. Also see “Care and Cleaning” |
||
and regulations. |
||
section of this manual. |
||
• The use of water hammer arrestors is strongly |
||
|
||
recommended for commercial applications. All piping |
• This product contains mechanical and/or electrical |
|
behind the walls should be properly secured and |
components that are subject to normal wear. These |
|
fastened. |
||
components should be checked on a regular basis and |
||
• Water supply lines must be sized to provide an |
||
replaced as needed to maintain the valve’s performance. |
||
adequate volume of water for each fixture. |
|
3 |