Copyright 2001 Allied Telesyn International Corp.
960 Stewart Drive Suite B, Sunnyvale CA 94085, USA
All rights reserved. No part of this publication may be reproduced without prior written permission
from Allied Telesyn International Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names,
logos or other designations mentioned herein are trademarks or registered trademarks of their
respective own ers .
Allied Telesyn International Corp. reserves the right to make changes in specifications and other
information contained in this document witho ut prio r writte n noti ce. The infor mation prov id ed
herein is subject to change without notice. In no event shall Allied Telesyn International Corp. be
liable for any incidental, special, indirect, or consequential damages whatsoever, including but not
limited to lost profits, a rising out of or related to this manual or the information contai ned herein,
even if Allied Telesyn International Corp. has been advised of, known, or should have known, the
possibility of such damages.
Page 3
Electrical Safety and Emission Compliance
Statement
Standards: This product meets the following standards.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of F CC Rul e s. Th es e l im i t s are desi gn ed t o prov id e reas o n ab l e pr ot ec t ion against
harmful interference when th e eq uipment is operated in a commercia l environment. Th is equipment
generates, uses, and can rad iate radio frequency en ergy and, if not installed an d use d in acco r d an ce
with this instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void
your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
RFI EmissionFCC Part 15 (Class A), EN55022 (Class A),
WARNING: In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
ImmunityEN55024
Electrica l SafetyUL 1950 (UL/cUL), EN60950 (TUV), EN60825
Important: Appendix A contains translated safety statements for installing this equipment. When you
$
see the
Wichtig: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie
$
Vigtigt: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af dette udstyr. Når
De ser symbolet
Belangrijk: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van deze
apparatuur. Wannee r u de
taal.
Important: L'annexe A contient les instructions de sécurité relatives à l'installation de cet équipement.
Lorsque vous voyez le symbole
instructions dans votre langu e.
Tärkeää: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet
symbolin, katso käännettyä turvaohjetta liitteestä A.
Importante: l’Appendice A contiene avvisi di si cu rezza tradotti per l’installazione di questa
apparecchiatura. Il simbolo
lingua.
Viktig: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser
$
Importante: O Anexo A contém advertências de segurança traduzidas para instalar es te eq uipamento.
Quando vir o símbolo
Importante: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo.
Cuando vea el símbolo
Obs! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning.
När du ser
, go to Appendix A for the translated safety statement in your language.
sehen, schlagen Sie in Anhang A den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
$
, skal De sl å op i t illæ g A og f inde d e ove rsatt e si kker heds advars ler i Dere s ege t spr og.
$
ziet, raadpleeg Appendix A voor vertaalde veiligheidsinstructies in uw
$
$
, indica di consultare l’Appendice A per l’avviso di s icurezza nella pro pria
, åpner du til Tillegg A for å finne den oversatte sikkerhetsin fo rmasjonen på ønsket språk.
$
, leia a advertência de segurança traduzida no seu idioma no Ane xo A.
$
, vaya al Apéndice A para ver el mensaje de seguridad traducido a su idioma.
$
, skall du gå till Bilaga A för att läsa det öve rsatta säkerhetsmeddelandet på ditt språk.
EN61000-3-2, EN61000-3-3
$
2
$
3
$
1
$
, reportez-vous à l'annexe A pour consulter la traduction de ces
$
4
-
iii
Page 4
Page 5
Table of Contents
Electrical Safety and Emission Compliance Statement ......................iii
Welcome to Allied Telesyn .........................................................................vii
Where to Find Web-based Guides ...................................................................vii
The guide contains instructions on how to install the AT-FS713FC/xx and
AT-FS717FC/xx Series Ethernet Switches.
Where to Find Web-based Guides
The Allied Telesyn web site at www.alliedtelesyn.com provides you with an
easy way to access the most recent documentation, software, and technical
information for all of our products. For product guides, select “Support &
Services” from our web site.
Document Conventions
This guide uses several conventions that you should become familiar with
before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may
result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may
result in bodily injury.
vii
Page 8
Contacting Allied Telesyn Technical Support
You can contact Allied Telesyn technical support online or by telephone, fax,
or e-mail.
Online Suppo rt
You can request technical support online by filling out the Technical Enquiry
Form or by accessing the Knowledge Base. You can use the Knowledge Base to
submit questions to our technical support staff and review answers to
previously asked questions.
To access the Knowledge Base, select “Support & Services”, then select “Help”
from www.alliedtelesyn.com. To access the Technical Enquiry Form, select “Contact Us” from our web site.
Telephone and Fax Support
For technical support via fax, please fill out the “Technical Support Fax
Order” on page 35 and send it to the appropriate location listed below.
Americas
United States, Canada, Mexico,
Central America, South America
Tel:1 (800) 428-4835, option 4
Fax: 1 (425) 481-3790
Asia
Singapore, Taiwan, Thailand, Malaysia,
Indonesia, Korea, Philippines, China,
India, Hong Kong
Tel:(+65) 3815-612
Fax: (+65) 3833-830
Australia
Australia, New Zealand
Tel:1 (800) 000-880
Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg,
The Netherlands, Middle East, Africa
Tel:(+33) 0-1-60-92-15-25
Fax: (+33) 0-1-69-28-37-49
viii
Germany
Germany, Switzerland, Austria, Eastern
Europe
Tel:(+49) 30-435-900-126
Fax: (+49) 30-435-70-650
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Technical Support E-mail Addresses
United States and Canada
TS1@alliedtelesyn.com
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
Europe
support_europe@alliedtelesyn.com
Returning Products
Products for return or repair must first be assigned a Return Materials
Authorization (RMA) number. A product sent to Allied Telesyn without a
RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one
of the following locations:
Tel: International code + 425-481-3852
Fax: International code + 425-481-3895
Mexico
Toll-free: 800-424-5012, ext 3852
Fax: International code + 425-481-3895
Australia
Toll-free: 1-800-000-880
Fax: 2-9438-4966
Europe, Africa, and Middle East
Tel: +44-1793-501401
Fax: +44-1793-431099
Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 3852
Asia and Southeast Asia
Tel: +65 381-5612
Fax: +65 383-3830
New Zealand
Toll-free: 0800-45-5782
FTP Server
If you need management software for an Allied Telesyn managed device and
you know the file name of the software, you can download the software by
connecting directly to our FTP server at ftp.alliedtelesyn.com. At login,
enter ‘anonymous’ as the user name and your e-mail address as the password.
ix
Page 10
For Sales or Corporate Information
You can contact Allied Telesyn for sales or corporate information at the
location listed below:
Allied Telesyn International Corp.
19800 North Creek Parkway, Suite 200
Bothell, WA 98011
Tel: 1 (425) 487-8880
Fax: 1 (425) 489-9191
Tell Us What You Think
If you have any comments or suggestions on how we might improve this or
other Allied Telesyn documents, please fill out the General Enquiry Form
online. This form can be accessed by selecting “Contact Us” at
www.alliedtelesyn.com.
x
Page 11
Chapter 1
Overview
The AT-FS713FC/xx and AT-FS717FC/xx Series Fast Ethernet Switches
include the following models:
These units are unmanaged Layer 2 switches. These switches can be used as a
‘bridge’ between the different workgroups in your network or they can be used
to create small workgroups with dedicated 10/100 Mbps links to your network
devices. They can also be used to connect to other Ethernet switches so that
they can be part of a larger Ethernet network.
The AT-FS713FC/xx Series Switches feature twelve 10/100Base-TX twisted
pair ports and a 100Base-FX fiber optic port. The twisted pair ports have a
RJ-45 connector and a maximum operating distance of 100 meters (328 feet).
The fiber optic port has a FJ, LC, MT, SC, ST, or VF connector, depending on
the model, and a maximum operating distance of 2 kilometers (1.2 miles).
The AT-FS717FC/xx Series Switches feature sixteen 10/100Base-TX twisted
pair ports and a 100Base-FX fiber optic port. The twisted pair ports have a
RJ-45 connector and a maximum operating distance of 100 meters (328 feet).
The fiber optic port has a FJ, LC, MT, SC, ST, or VF connector, depending on
the model, and a maximum operating distance of 2 kilometers (1.2 miles).
The fiber optic port operates at 100 Mbps and features half- and full-duplex
operation. The twisted pair port operates at 10 or 100 Mbps and autonegotiates the duplex mode.
The AT-FS713FC/xx and AT-FS717FC/xx Series Switches are easy to install
and do not require software configuration or management.
1
Page 12
Figure 1 illustrates the front and back panels of an AT-FS713FC/xx Series
Switch.
Front Panel
Duplex Switch
LEDs
AT-FS713FC/MT
10Base-T/100Base-TX 12 Port Fast Ethernet Switch with 100FX Uplink
100FX10/100TX
LNK/
ACT
FD
1197531
12131310 8 6 4 2
100FX
DUPLEX
HALF
FULL
LNK/
ACT
100M
LNK/
ACT
PWR
100M
Back Panel
1357911
2468101213
120-240V 50-60Hz 0.5A
Power Plug
10/100Base-TX Ports
100Base-FX Port
Figure 1 AT-F S7 13 FC /x x Serie s Switc h (AT- FS 71 3F C/ MT Mod el)
Figure 2 illustrates the front and back panels of an AT-FS717FC/xx Series
Switch.
LEDs
100FX10/100TX
1113159 7 5 3 1
LNK/
ACT
FD
12141617108642
LNK/
ACT
100M
LNK/
ACT
PWR
100M
Front Panel
AT-FS717FC/ST
10Base-T/100Base-TX 16 Port Fast Ethernet Switch with 100FX Uplink
Duplex Switch
100FX
DUPLEX
HALF
FULL
17
Back Panel
2
1357 9111315
TXRX
246810121416
10/100Base-TX Ports
17
100Base-FX Ports
Figure 2 AT-FS717FC/xx Series Switch (AT- FS717FC/ST Model)
120-240V 50-60Hz 0.5A
Power Plug
Page 13
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Table 1 lists the maximum operating distances for the AT-FS713FC/xx Series
Switches.
Table 1 AT-FS713FC/xx Series Maximum Operating Distan ces
10/100Base-TX100Base-FX
Model
Connector
Maximum
Operating Distance
Connector
Maximum
Operating Distance
AT-FS713FC/FJRJ-45100 m (328 ft)FJ2 km (1.2 mi)
AT-FS713FC/LCRJ-45100 m (328 ft)LC2 km (1.2 mi)
AT-FS713FC/MTRJ-45100 m (328 ft)MT2 km (1.2 mi)
AT-FS713FC/SCR J-45100 m (328 ft)SC2 km (1.2 mi)
AT-FS713FC/STRJ-45100 m (328 ft)ST2 km (1.2 mi)
AT-FS713FC/VFRJ-45100 m (328 ft)VF2 km (1.2 mi)
Table 2 lists the maximum operating distances for the AT-FS717FC/xx Series
Switches.
Table 2 AT-FS717FC/xx Series Maximum Operating Distan ces
10/100Base-TX100Base-FX
Model
Connector
Maximum
Operating Distance
Connector
Maximum
Operating Distance
AT-FS717FC/FJRJ-45100 m (328 ft)FJ2 km (1.2 mi)
AT-FS717FC/LCRJ-45100 m (328 ft)LC2 km (1.2 mi)
AT-FS717FC/MTRJ-45100 m (328 ft)MT2 km (1.2 mi)
AT-FS717FC/SCR J-45100 m (328 ft)SC2 km (1.2 mi)
AT-FS717FC/STRJ-45100 m (328 ft)ST2 km (1.2 mi)
AT-FS713FC/VFRJ-45100 m (328 ft)VF2 km (1.2 mi)
3
Page 14
Features
q LEDs for unit and port status
q Auto MDI/MDI-X for the twisted pair ports
q Half- or full-duplex operation on the fiber optic port
q Auto-negotiation of the duplex mode on the twisted pair ports
q RJ-45 twisted pair connectors
q FJ, LC, MT, SC, ST, or VF fiber optic connector
q Store and forward Ethernet packet handling
q MAC address table with a capacity of 4,000 addresses
Status LEDs
Table 3 defines the LEDs on the AT-FS713FC/xx and AT-FS717FC/xx Series
Switches.
Table 3 LEDs
LEDColorDescription
PWRGreenThe switch is receiving power.
FDGreen
OFF
100MGreen
OFF
LNK/ACTGreen
Blinking Green
OFF
4
The fiber optic po rt is operating in full- duplex mode.
The fiber optic port is operating in half-duplex mode.
The twisted pair port is operating at 100 Mbps.
The twisted pair port is operating at 10 Mbps.
The port has established a valid link with the end-node
connected to the port.
Activity is detected on the port.
The port has not established a link wi th the end-node.
Page 15
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Twisted Pair Ports
The AT-FS713FC/xx and AT-FS717FC/xx Series Switches have twelve and
sixteen 10/100Base-TX twisted pair ports, respectively.
Port Speed
The twisted pair ports are compliant with the 10Base-T and 10Base-TX
standards and are capable of either 10 Mbps or 100 Mbps operation. The ports
are IEEE 802.3u auto-negotiation compliant. The speed of the port is set
automatically by the switch after determining the speed of the end-node
connected to the port. Auto-negotiation is designed to ensure that each port on
the switch and the end-node connected to each port are operating at the same
speed and that they are communicating at the highest possible common speed
of the devices.
Duplex Mode
The twisted pair ports on the switches can operated in either half- or fullduplex mode and are set automatically through auto-negotiation. If the endnode is capable of full-duplex mode, the twisted pair port is set to full-duplex.
If the end-node is capable of half-duplex mode, the port is set to half-duplex.
Auto MDI/MDI-X
An RJ-45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network
device can have one of two possible wiring configurations: MDI or MDI-X. The
RJ-45 port on a PC, router, or bridge is typically wired as MDI, while the
twisted pair port on a switch or hub is usually MDI-X.
To connect two 10 Mbps or 100 Mbps network devices together that have
dissimilar port wiring configurations, such as MDI to MDI-X, you would
usually use a straight-through twisted pair cable. To connect two network
devices that have the same wiring configuration, such as MDI to MDI, you
would usually use a crossover cable.
The AT-FS713FC/xx and AT-FS717FC/xx Series Switches feature automatic
MDI/MDI-X. Each port automatically determines the configuration of the port
on the device to which it is connected and then configures itself appropriately.
For example, if a port on a switch is connected to a port on a bridge, which is
typically wired as MDI, the port on the switch automatically configures itself
as MDI-X. This feature allows you to use either crossover cables or straightthrough cables when connecting devices to these switches.
5
Page 16
Fiber Optic Port
The AT-FS713FC/xx and AT-FS717FC/xx Series Switches have one
100Base-FX fiber optic port. The fiber optic port has a FJ, LC, MT, SC, ST, or
VF connector, depending on the model.
Port Speed
The fiber optic port is compliant with the 100Base-FX standard and has a
fixed operating speed of 100 Mbps. The end-node connected to the fiber optic
port on the switch must also be able to operate at 100 Mbps.
Duplex Mode
Duplex mode refers to the way an end-node sends and receives data on the
network. An end-node can operate in either half- or full-duplex mode,
depending on its capabilities. An end-node that is operating in half-duplex
mode can either send data or receive data, but it cannot do both at the same
time. An end-node that is operating in full-duplex mode can send and receive
data simultaneously. The best network performance is achieved when an endnode can operate at full-duplex, since the end-node is able to send and receive
data simultaneously.
The AT-FS713FC/xx and AT-FS717FC/xx Series Switches can operate in
either half- or full-duplex mode. To set the duplex mode on the fiber optic port,
slide the 100FX DUPLEX switch UP (half-duplex) or DOWN (full-duplex). The
switch can operate with end-nodes capable of either half-duplex mode or fullduplex mode.
6
Page 17
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
MAC Address Table
Up to 4,000 MAC addresses can be stored in the switch’s MAC address table.
The switch’s self-learning feature will learn all new addresses in real-time
after power-up. If the source address of an incoming packet is not found in the
MAC address table, the switch will update the table with the new address.
The switch also has an automatic address aging feature that will delete a
source address from the table if it has not seen a frame from the end-node
with that address within five minutes. This prevents the table from becoming
filled with addresses of end-nodes that are no longer active.
The switch forwards all multicast, broadcast, and unicast packets when the
MAC address table has exceeded its storage limit.
Store and Forward
The AT-FS713FC/xx and AT-FS717FC/xx Series Switches support store and
forward switching at Fast Ethernet full-wire speed in 100 Mbps, half- or fullduplex mode. Packets entering each port are stored in buffers. Once the full
packet is received, the switch will forward or discard the packet, depending on
its destination address and error status. This ensures that only error-free
packets destined for another segment will be transferred across the switch,
reducing network load. For example, if the packet entering from Port 1 is
destined for an end-node on Port 2, the switch forwards the frame if the frame
does not contain any errors. If the packet from Port 1 is destined for an endnode also connected to Port 1, the packet is discarded.
The switch will discard CRC errors, misaligned, runt, and under-oversized
packets. When the packet has dribble bits at the end, the switch will truncate
to octet boundary and check for a good FCS before forwarding.
7
Page 18
Network Topologies
The AT-FS713FC/xx or AT-FS717FC/xx Series Switches can be used in
several network topologies. Some of these topologies are described below.
Workgroup Topology
Figure 3 illustrates a workgroup topology where each end-node is connected
directly to a port on an AT-FS713FC/SC switch, giving each end-node a
dedicated 10 Mbps or 100 Mbps link.
AT-FS713FC/SC
1357911
TX RX
24681012 13
Figure 3 Power Workgroup Topology
120-240V 50-60Hz 0.5A
10 Mbps
100 Mbps
8
Page 19
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Ethernet Hub Workgroup Topology
Figure 4 illustrates an Ethernet hub workgroup topology where an
AT-FS713FC/SC is used to connect together four 10/100 Mbps Ethernet hubs.
This allows the switch to function as a bridge between the different
workgroups by controlling the flow of data between the workgroups. The
switch transfers an Ethernet frame from hub-to-hub only when the
destination end-node for the frame is on a different hub than the end-node
that originated the frame. This reduces the amount of unnecessary data traffic
in each workgroup. This frees up bandwidth and improves network
performance.
AT-FS713FC/SC
1357911
24681012 13
TX RX
120-240V 50-60Hz 0.5A
Ethernet Hub
8
7
2
1
6
54
3
Ethernet HubEthernet Hub
8
7
2
54
1
3
6
10 Mbps
100 Mbps
Figure 4 Ethernet H ub Workgroup Topology
Ethernet Hub
8
7
6
54
3
8
7
6
54
2
1
2
1
3
9
Page 20
Backbone Topology
If your network consists of several AT-FS713FC/xx or AT-FS717FC/xx Series
Switches, then you will probably want to connect them together to form an
integrated network. Here the fiber optic ports can be extremely useful. You
can use the ports to create a fiber optic backbone. With a maximum operating
distance of 2 kilometers (1.2 miles), the ports can be used to connect together
switches that are physically far apart. Figure 5 shows an AT-FS713FC/ST
switch and an AT-FS717FC/ST switch interconnected using the fiber optic
ports to create a backbone topology.
This chapter contains desktop and wall-mounting installation instructions for
an AT-FS713FC/xx or AT-FS717FC/xx Series Switch.
Reviewing Safety Guidelines
Please review the following safety guidelines before you begin to install the
switch.
Warning
Class 1 laser product. $ 5
Warning
Do not stare into the laser beam. $ 6
Warning
Electric Shock Hazard: To prevent electric shock, do not remove the
cover. There are no user-serviceable parts inside. The unit contains
hazardous voltages and should only be opened by a trained and
qualified technician. $ 7
Warning
Lightning Danger: Do not work on this equipment or cables during
periods of lightening activity. $ 8
Warning
Power cord is used as a disconnection device: To de-energize
equipment, disconnect the power cord. $ 9
11
Page 22
Caution
Pluggable Equipment: The socket outlet should be installed near the
equipment and should be easily accessible. $ 10
Caution
Air vents: The air vents must not be blocked on the unit and must have
free access to the room ambient air for cooling. $ 11
Caution
Operating Temperature: This product is designed for a maximum
ambient temperature of 40°C. $ 12
Caution
All Countries: Install this product in accordance with local and
National Electric Codes. $ 13
Verifying the Package Contents
Make sure the following items are included in your package. If any item is
missing or damaged, contact your Allied Telesyn sales representative for
assistance.
q One AT-FS713FC/xx or AT-FS717FC/xx Series Switch
q Power cord
q Four protective feet (for desktop use only)
q This installation guide
q Warranty card
12
Page 23
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Planning the Installation
Be sure to observe the following guidelines when planning the installation of
your switch.
q The end-node connected to the 100Base-FX fiber optic port must be
able to operate at 100 Mbps.
q The end-node connected to a 10/100Base-TX twisted pair port must be
able to operate at 10 or 100 Mbps.
q The end-node connected to a port on the switch can be a network
adapter card, repeater, router, hub, or another switch.
q Refer to Table 4 for the cabling specifications for the twisted pair
One Media Converter InlineSwitch to switch372 m (1,221 ft)
Workstation to switch372 m (1,221 ft)
Switch to Class I repeater137 m (450 ft)
Switch to Class II repeater18 5 m (607 ft)
Two Media Converters
Switch to switch332 m (1,089 ft)
Inline
Workstation to switch322 m (1, 089 ft)
Switch to Class I repeater97 m (318 ft)
Switch to Class II repeater14 5 m (476 ft)
1. The total distance of the fiber optic port lengths cannot exceed the limits stated in the table. Each media converter
used inline within a single collision domain reduces the overall segment length by 40 meters (131 feet).
Selecting a Site
Be sure to observe the following guidelines when selecting a site for your
switch.
q Select a site that is dust-free and moisture-free.
q Select a site that will allow you to easily access the data cables and
power cord.
q Make sure the air flow around the switch and through its vents on the
side and back are not restricted.
q For use on a desktop, make sure the desktop is level and secure.
q Use dedicated power circuits or power conditioners to supply reliable
power to the device.
q Keep the twisted pair cabling away from sources of electrical noise,
such as radios, transmitters, power lines, broadband amplifiers,
electrical motor, and fluorescent fixtures.
14
Page 25
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Installing the Switch On a Table or Desktop
To wall-mount the switch, refer to “Wall-mounting the Switch” on page 16. To
install the switch on a table or desktop, perform the following procedure:
1.Remove all components from the shipping package and store the
packaging material in a safe location.
Note
Do not remove the dust covers from the fiber optic port until you are
ready to connect the fiber optic cable. Dust contamination can adversely
impact the operating performance of the port and the switch.
2.Attach the four protective feet (provided) to each corner of the base of the
unit.
3. Connect the twisted pair cables to the RJ-45 connectors.
4. Remove the dust cover from the fiber optic port and connect the fiber optic
cable to the port.
5. Set the 100FX DUPLEX switch on the fiber optic port to either HALF for
half-duplex or FULL for full-duplex operation. The capabilities of the endnode connected to the fiber optic port will determine the correct setting for
this switch. If the end-node is capable of only half-duplex, set the switch to
HALF. If the end-node is capable of full-duplex, set the switch to FULL.
Caution
Power cord is used as a disconnection device: To de-energize
equipment, disconnect the power cord. $ 10
6. Power ON the switch by plugging one end of the power cord to the back of
the switch and the other end of the power cord to a power outlet. The PWR
LED should be green. If the LED is OFF, refer to “Troubleshooting” on
page 19 for assistance.
7. Power ON the end-nodes connected to the ports on the switch.
8. Check the LNK/ACT LED for each port. The LED should be green or
blinking. If the LED is OFF, refer to “Troubleshooting” on page 19 for
assistance.
The switch is now ready for use.
15
Page 26
Wall-mounting the Switch
The switch can be mounted either vertically or horizontally on a wall using
the keyholes on the bottom of the chassis. For wall-mount installation, you
will need two panhead screws and plastic anchors.
To wall-mount the switch, perform the following procedure:
1. If attached, remove the rubber feet, data cables, and power cord from the
switch.
2. Select a wall location for the device.
3. Install the plastic anchors and panhead screws 100 millimeters (3.94
inches) apart on the wall.
4. Position the device onto the wall screws. If you are mounting the switch
horizontally, position the switch so that the ports are facing down and the
LEDs are facing up. If you are mounting the switch vertically, position the
switch so that the ports are facing to the left and the LEDs to the right.
5. Connect the twisted pair cables to the RJ-45 connectors.
6. Connect the fiber optic cable to the fiber optic port.
7. Set the 100FX DUPLEX switch on the fiber optic port to either HALF for
half-duplex or FULL for full-duplex operation. The capabilities of the endnode connected to the fiber optic port will determine the correct setting for
this switch. If the end-node is capable of only half-duplex, set the switch to
HALF. If the end-node is capable of full-duplex, set the switch to FULL.
Warning
The power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. $9
8. Power ON the switch by plugging one end of the power cord to the back of
the switch and the other end of the power cord to a power outlet. The PWR
LED should be green. If the LED is OFF, refer to “Troubleshooting” on
page 19 for assistance.
9. Power ON the end-nodes connected to the ports on the switch.
10. Check the LNK/ACT LED for each port. The LED should be green or
blinking. If the LED is OFF, refer to “Troubleshooting” on page 19 for
assistance.
The switch is now ready for use.
16
Page 27
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Warranty Registration
When you have finished installing the product, register your product by
completing the enclosed warranty card and sending it in. You can also fill out
the registration online by selecting “Warranties” under “Support & Services”
from www.alliedtelesyn.com.
17
Page 28
Page 29
Chapter 3
Troubleshooting
Follow the guidelines below to test and troubleshoot the installation in the
event a problem occurs.
If the PWR LED is OFF, do the following:
q Make sure that the power cord is securely connected to the wall outlet
and the power connector on the back of the switch.
q Verify that the power outlet has power by connecting another device
to it.
q Try connecting the switch to another power source.
q Try using another power cord.
If a LNK/ACT LED for a twisted pair port is OFF, do the following:
q Check that the end-node connected to the port is powered ON and is
operating properly.
q Check that the twisted pair cable is securely connected to the port on
the switch and to the port on the end-node.
q Verify that the end-node is operating at 10 or 100 Mbps and half-
duplex mode.
q Make sure that the twisted pair cable does not exceed 100 meters (328
feet) and that you are using a Category 3 or better cable for 10Base-T
operation or a Category 5 or better cable for 100Base-TX operation.
19
Page 30
If the LNK/ACT LED for the fiber optic port is OFF, do the following:
q Verify that the end-node connected to the port is ON and is operating
properly.
q Check that the fiber optic cable is securely connected to the port on the
switch and to the port on the end-node.
q Check to be sure that the end-node connected to the port is operating
at 100 Mbps.
q Make sure that the cable connected to the fiber optic receiver port on
the switch is connected to the transmitter port on the end-node and
that the fiber optic transmitter port on the switch is connected to the
receiver port on the end-node.
q Test the attenuation on the fiber cable to ensure that it does not
exceed acceptable values.
q Verify that you are using the appropriate type of fiber optic cabling
and that you have not exceeded the maximum operating distance. For
cable types and operating distance, refer to Table 1 and Table 2 on
page 3.
q Make sure that the 100FX DUPLEX switch is set correctly. The switch
should be set to match the duplex mode of the end-node connected to
the fiber optic port.
q Check that the operating specifications (e.g., wavelength and
maximum operating distance) of the fiber optic port on the end-node
are compatible with the operating specifications of the fiber optic port
on the switch. See “Fiber Optic Port Specifications” on page 22 for
additional information on the fiber optic port.
If you are still experiencing problems after testing and troubleshooting the
installation, contact Allied Telesyn Technical Support for assistance. Refer to
“Contacting Allied Telesyn Technical Support” on page viii or visit our web
site at www.alliedtelesyn.com for support information.
20
Page 31
Appendix A
Technical Specifications
Physical
Dimensions:W x D x H
1.7 cm x 17.9 cm x 9.8 cm (0.7 in x 7 in x 3.9 in)
Weight:0.42 kg (0.9 lbs)
Temperature
Maximum Operating:0° to 40° C (32° to 104° F)
Maximum Storage:-25° to 70° C (-13° to 158° F)
Relative Humidity:5% to 95% non-condensing
Operating Altitude:Up to 3,000 meters (9,843 feet)
Electrical Rating
Input Supply Voltage:100-240 V AC
Maximum Current:0.5 A
Power Consumption:8 watts
Agency Certifications
Safety:UL/cUL, TUV
Standard:UL1950, EN60950
Immunity:EN55024
EMI/RFI:FCC Part 15 (Class A), EN55022 (Class A),
EN61000-3-2, EN61000-3-3
21
Page 32
Fiber Optic Port Specifications
Table 7 through Table 10 list the specifications for the fiber optic port.
Table 7 Fiber Optic Transmi tter
ModelFiber Type
Fiber
Optic
Diameter
(microns)
Optical
Frequency
Launch Power (dBm)
MaximumAverage Minimum
All modelsMultimode50/1251310 nm-14.0-20.3-22.5
Multimode 62.5/1251310 nm-14.0-16.8-19.0
1. The launch power is measured at one meter from th e t r ansmitter.
Table 8 Fiber Optic Receiver
ModelFiber Type
Fiber
Optic
Diameter
(microns)
Optical
Frequency
Receiver Power (dBm)
Minimum Average Saturation
All modelsMultimode50/1251310 nm-31.8-34.5-14.0
Multimode62.5/1251310 nm-31.8-34.5-14.0
Table 9 Fiber Optic Dat alink
Model
Fiber
Type
Minimum
Power/Link
Budget
Average
Signal
Loss (dB)
Minimum
Distance
Specs.
1
Maximum
Distance
Specs.
1
All models50/125
13.0018.7002 km (1.2 mi)
Multimode
62.5/125
16.8022.5002 km (1.2 mi)
Multimode
1. The recommended minimum range is stated in all cases where the maximum transmitter output
power excee ds the receivers saturati o n level. Thi s is to prevent blindi ng or burning out of the o ptical
receiver on the far end-node.
22
Page 33
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Table 10 Fiber Optic Loss Specification (Benchmark)
Fiber Type
Fiber Optic
Diameter
Multimode50/125
Optical
Frequency
Typical Loss
Factor
Worst Case
Loss Factor
Bandwidth
1310 nm1.00 dB/km1.50 dB/km400 Mhz-km
microns
62.5/125
1310 nm1.00 dB/km1.50 dB/km500 Mhz-km
microns
Pinout Assignments
Figure 6 shows the pin assignments of the RJ-45 connector.
Pin 1Pin 8
Figure 6 RJ-45 Pin Assignments
Table 11 lists the 10/100Base-TX connector pins and their signals when the
port is operating in either MDI or MDI-X configuration.
Important: This appendix contains multiple-language translations for the
safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch
enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af
sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de
veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des
instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla
kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvisi di
sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av
sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das advertências
de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los
mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av
säkerhetsmeddelandena i denna handledning.
25
Page 36
Standards: This product meets the following standards.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with this instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the
FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian InterferenceCausing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le
matériel brouilleur du Canada.
$
1RFI EmissionFCC Part 15 (Class A), EN55022 (Class A),
$
2Warning: In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
EN61000-3-2, EN61000-3-3
$
5Warning: Class 1 Laser product.
$
6Warning: Do not stare into the laser beam.
$
7ELECTRICAL NOTICES
$
8LIGHTNING DANGER
$
9Caution: POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-
$
10PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment
$
11Caution: Air vents must not be blocked and must have free access to the room
$
12Operating Temperature: This product is designed for a maximum ambient
Warning: ELECTRIC SHOCK HAZARD
To prevent ELECTRIC shock, do not remove the cover. No user-serviceable parts
inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a
trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK,
disconnect electric power to the product before connecting or disconnecting the LAN
cables.
Danger: DO NOT WORK on equipment or CABLES during periods of LIGHTNING
ACTIVITY.
ENERGIZE EQUIPMENT, disconnect the power cord.
and shall be easily accessible.
ambient air for cooling.
temperature of 40° degrees C.
26
Page 37
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
$
13All Countries: Install product in accordance with local and National Electrical Codes.
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
$
1HochfrequenzstörungFCC Part 15 (Class A), EN55022 (Class A),
$
2Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
$
3StörsicherheitEN55024
$
4Elektrische Sicherheit UL 1950 (UL/cUL), EN60950 (TUV), EN60825
$
5WARNUNG: Laserprodukt der Klasse 1.
$
6Warnung: Nicht direkt in den Strahl blicken.
$
7Achtung: GEFÄHRLICHE SPANNUNG
$
8GEFAHR DURCH BLITZSCHLAG
$
9Vorsicht: DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG.
$
10STECKBARES GERÄT: Die Anschlußbuchse sollte in der Nähe der Einrichtung
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen
ergreifen.
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile.
Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem
Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
ausführen.
ZUR TRENNUNG VOM NETZ, KABEL AUS DER STECKDOSE ZIEHEN.
angebracht werden und leicht zugänglich sein."
EN61000-3-2, EN61000-3-3
$
11Vorsicht: Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum
$
12Betriebstemperatur: Dieses Produkt wurde für den Betrieb in einer
$
13Alle Länder: Installation muß örtlichen und nationalen elektrischen Vorschriften
$
1Radiofrekvens
$
2Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver
Umgebungstemperatur von nicht mehr als 40° C entworfen.
entsprechen.
Standarder: Dette produkt tilfredsstiller de følgende standarder.
forstyrrelsesemissionFCC Part 15 (Class A), EN55022 (Class A),
EN61000-3-2, EN61000-3-3
det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
27
Page 38
$
7ELEKTRISKE FORHOLDSREGLER
$
8FARE UNDER UVEJR
$
9Advarsel: DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE
$
10UDSTYR TIL STIKKONTAKT, stikkontakten bør installeres nær ved udstyret og skal
$
11Advarsel: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den
$
12Betjeningstemperatur: Dette apparat er konstrueret til en omgivende temperatur
$
13Alle Lande: Installation af produktet skal ske i overensstemmelse med lokal og
$
1RFI EmissieFCC Part 15 (Class A), EN55022 (Class A),
$
2Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval
Advarsel: RISIKO FOR ELEKTRISK STØD For at forebygge ELEKTRISK stød,
undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren.
Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af
en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD,
afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller
afmonteres.
Fare: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET.
STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen
ud af stikket.
være lettilgængelig.
omgivende luft i rummet for afkøling.
på maksimum 40 grader C.
national lovgivning for elektriske installationer.
Eisen: Dit product voldoet aan de volgende eisen.
EN61000-3-2, EN61000-3-3
de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
9Waarschuwing: HET TOESTEL WORDT UITGESCHAKELD DOOR DE
$
10AAN TE SLUITEN APPARATUUR, de contactdoos wordt in de nabijheid van de
Waarschuwing: GEVAAR VOOR ELEKTRISCHE SCHOKKEN
Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin
bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden. Dit
toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door
een daartoe opgeleide en bevoegde technicus. Om het gevaar op ELEKTRISCHE
SCHOKKEN te vermijden, moet u het toestel van de stroombron ontkoppelen alvorens
de LAN-kabels te koppelen of ontkoppelen.
Gevaar: NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
STROOMKABEL TE ONTKOPPELEN.OM HET TOESTEL STROOMLOOS TE
MAKEN: de stroomkabel ontkoppelen.
apparatuur geïnstalleerd en is gemakkelijk te bereiken."
28
Page 39
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
$
11Opgelet: De ventilatiegaten mogen niet worden gesperd en moeten de omgevingslucht
$
12Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer
$
13Alle Landen: het toestel installeren overeenkomstig de lokale en nationale
$
1Emission d’interférences
$
2Mise En Garde : dans un environnement domestique, ce produit peut provoquer des
Normes: ce produit est conforme aux normes de suivantes:
radioélectriquesFCC Part 15 (Class A), EN55022 (Class A),
interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures
adéquates.
Avertissement: DANGER D’ÉLECTROCUTION
Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement protecteur du
matériel. Ce matériel ne contient aucun élément réparable par l’utilisateur. Il
comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un
technicien dûment qualifié. Pour éviter tout risque d’ÉLECTROCUTION, débrancher
le matériel avant de connecter ou de déconnecter les câbles LAN.
EN61000-3-2, EN61000-3-3
$
8DANGER DE FOUDRE
$
9Attention: LE CORDON D’ALIMENTATION SERT DE MISE HORS CIRCUIT.
$
10EQUIPEMENT POUR BRANCHEMENT ELECTRIQUE, la prise de sortie doit être
$
11Attention: Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant de
$
12Température De Fonctionnement: Ce matériel est capable de tolérer une
$
13Pour Tous Pays: Installer le matériel conformément aux normes électriques
Danger: NE PAS MANIER le matériel ou les CÂBLES lors d’activité orageuse.
POUR COUPER L’ALIMENTATION DU MATÉRIEL, débrancher le cordon.
placée près de l’équipement et facilement accessible".
circuler librement pour le refroidissement.
température ambiante maximum de ou 40 degrés Celsius.
nationales et locales.
29
Page 40
Standardit: Tämä tuote on seuraavien standardien mukainen.
$
1Radioaaltojen häirintäFCC Part 15 (Class A), EN55022 (Class A),
$
2Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä
9Huomautus: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
$
10PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle ja
$
11Huomautus: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin
toimenpiteisiin.
Varoitus: SÄHKÖISKUVAARA
Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa
olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain
koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise
sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
Hengenvaara:ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
SALAMOINNIN AIKANA.
VIRTA KATKAISTAAN irrottamalla virtajohto.
siihen on oltava esteetön pääsy."
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
EN61000-3-2, EN61000-3-3
$
12Käyttölämpötila: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle
$
13Kaikki Maat: Asenna tuote paikallisten ja kansallisten sähköturvallisuusmääräysten
$
1Emissione RFI (interferenza
$
2Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio
Standard: Questo prodotto è conforme ai seguenti standard.
di radiofrequenza) FCC Part 15 (Class A), EN55022 (Class A),
EN61000-3-2, EN61000-3-3
interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati
provvedimenti.
30
Page 41
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
$
7AVVERTENZE ELETTRICHE
$
8PERICOLO DI FULMINI
$
9Attenzione: IL CAVO DI ALIMENTAZIONE È USATO COME DISPOSITIVO DI
$
10APPARECCHIATURA COLLEGABILE, la presa va installata vicino all’apparecchio
$
11Attenzione: le prese d’aria non vanno ostruite e devono consentire il libero ricircolo
$
12Temperatura Di Funzionamento: Questo prodotto è concepito per una temperatura
$
13Tutti I Paesi: installare il prodotto in conformità delle vigenti normative elettriche
$
1RFI strålingFCC Part 15 (Class A), EN55022 (Class A),
Attenzione: PERICOLO DI SCOSSE ELETTRICHE Per evitare SCOSSE
ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili
dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un
tecnico specializzato e qualificato. Per evitare ogni possibilità di SCOSSE
ELETTRICHE, interrompere l’alimentazione del dispositivo prima di collegare o
staccare i cavi LAN.
Pericolo: NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI
TEMPORALESCHE.
DISATTIVAZIONE. PER TOGLIERE LA CORRENTE AL DISPOSITIVO staccare il
cavo di alimentazione.
per risultare facilmente accessibile".
dell’aria ambiente per il raffreddamento.
ambientale massima di 40 gradi centigradi.
nazionali.
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
EN61000-3-2, EN61000-3-3
$
2Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
9Forsiktig: STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET. FOR Å
$
10UTSTYR FOR STIKKONTAKT. Stikkontakten skal monteres i nærheten av utstyret
$
11Forsiktig: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Advarsel: FARE FOR ELEKTRISK SJOKK For å unngå ELEKTRISK sjokk, må
dekslet ikke tas av. Det finnes ingen deler som brukeren kan reparere på innsiden.
Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig
kvalifisert tekniker. For å unngå ELEKTRISK SJOKK må den elektriske strømmen til
produktet være avslått før LAN-kablene til- eller frakobles.
Fare: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
og skal være lett tilgjengelig."
romtemperatur for avkjøling.
31
Page 42
$
12Driftstemperatur: Dette produktet er konstruert for bruk i maksimum
$
13Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale elektriske
$
1Emissão de interferência de
$
2Aviso: Num ambiente doméstico este produto pode causar interferência na
Padrões: Este produto atende aos seguintes padrões.
radiofrequênciaFCC Part 15 (Class A), EN55022 (Class A),
radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas
adequadas.
Atenção: PERIGO DE CHOQUE ELÉTRICO Para evitar CHOQUE ELÉTRICO, não
retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este
aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico
qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO,
desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os
cabos da LAN.
Perigo: NÃO TRABALHE no equipamento ou nos CABOS durante períodos
suscetíveis a QUEDAS DE RAIO.
EN61000-3-2, EN61000-3-3
$
9Cuidado: O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM DISPOSITIVO
$
10EQUIPAMENTO DE LIGAÇÃO, a tomada eléctrica deve estar instalada perto do
$
11Cuidado: As aberturas de ventilação não devem ser bloqueadas e devem ter acesso
$
12Temperatura De Funcionamento: Este produto foi projetado para uma
$
13Todos Os Países: Instale o produto de acordo com as normas nacionais e locais para
DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo
de ALIMENTAÇÃO.
equipamento e ser de fácil acesso."
livre ao ar ambiente para arrefecimento adequado do aparelho.
temperatura ambiente máxima de 40 graus centígrados.
instalações elétricas.
32
Page 43
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide
Estándares: Este producto cumple con los siguientes estándares.
$
1Emisión RFIFCC Part 15 (Class A), EN55022 (Class A),
$
2Advertencia: en un entorno doméstico, este producto puede causar
9Atencion: EL CABLE DE ALIMENTACION SE USA COMO UN
$
10EQUIPO CONECTABLE, el tomacorriente se debe instalar cerca del equipo, en un
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas
que sean convenientes al respecto.
Advertencia: PELIGRO DE ELECTROCHOQUE Para evitar un
ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al
cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES
PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado. Para evitar la
posibilidad de ELECTROCHOQUE desconecte la corriente eléctrica que llega al
producto antes de conectar o desconectar los cables LAN.
Peligro: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o
en LOS CABLES durante TORMENTAS ELECTRICAS.
DISPOSITIVO DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte
el cable de alimentación.
lugar con acceso fácil".
EN61000-3-2, EN61000-3-3
$
11Atencion: Las aberturas para ventilación no deberán bloquearse y deberán tener
$
12Temperatura Requerida Para La Operación: Este producto está diseñado para
$
13Para Todos Los Países: Monte el producto de acuerdo con los Códigos Eléctricos
$
1RadiostörningFCC Part 15 (Class A), EN55022 (Class A),
$
2Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
acceso libre al aire ambiental de la sala para su enfriamiento.
una temperatura ambiental máxima de 40 grados C.
locales y nacionales.
Standarder: Denna produkt uppfyller följande standarder.
EN61000-3-2, EN61000-3-3
tvinga användaren till att vidtaga erforderliga åtgärder.
33
Page 44
$
7Tillkännagivanden Beträffande Elektricitetsrisk:
$
8FARA FÖR BLIXTNEDSLAG
$
9Varning: NÄTKABELN ANVÄNDS SOM STRÖMBRYTARE FÖR ATT KOPPLA
$
10UTRUSTNING MED PLUGG. Uttaget skall installeras i utrustningens närhet och
$
11Varning: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande
$
12Driftstemperatur: Denna produkt är konstruerad för rumstemperatur ej
$
13Alla Länder: Installera produkten i enlighet med lokala och statliga bestämmelser
RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det
finns inga delar inuti som behöver underhållas. Denna apparat är under
HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att
undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LANkablarna ansluts eller kopplas ur.
Fara: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
Model number of Allied Telesyn product I am using________________________
Firmware release number of Allied Telesyn product _______________________
Other network software products I am using (e.g., network managers)
______________________________________________________________________
Detailed description (Please use separate sheet)
Please also fax printouts of relevant files such as batch files and configuration
files. When completed, fax this sheet to the appropriate Allied Telesyn office.
Fax numbers can be found on page viii.