Welcome to the Administrator Release Notes for Release 1.2.42 of the OmniAccess
3500 Nonstop Laptop Guardian. This document provides detailed information about the
product release and all identified issues that may impact the IT-administrator
experience of the solution. The previous revision of this document (25.01) was issued
on 11.27.2007 and was attached to Release 1.2.25 of the OmniAccess 3500 NLG. This
document should be read in conjunction with the previous version.
Please note that Release 1.2.42 of the OmniAccess 3500 NLG is a patch release that
only fixes bugs found in the previous release.
o Issue Date: January 29, 2008
o Distribution: General availability to all customers
•Hardware: OmniAccess 3500 Nonstop Laptop Guardian Enterprise Gateway,
Hardware Revision 1 (there is no change in the gateway hardware compared to
Release 1.2.25)
•Software
o Distribution Server: www.nonstopguardian.com (client software only)
o Directory: Link on the main page
o Package Files: See Table 1
Sr. File Name Description Size
(bytes)
1 NLG-Flash-
Image-
1.2.42-V4-
64.raw
Card
firmware
15,194,112
MD5 Hash Comments
5CCE2BBE16DDA2EB36A4E769655AAACF Pre-
installed in
the card
2
Page 3
Administrator Release Notes
2 NLG-
ManagementServerpgsqlbin-
1.2.42.rpm
3 NLG-
ManagementServer-
1.2.42.rpm
4 NLG-
Gateway-
1.2.42.rpm
5 NLG-
SMSServersetup-
1.2.42.exe
Database
software
running on
the gateway
Management
system
software
running on
the gateway
Gateway
software
Software for
Microsoft
SMS
integration
to be
installed in
the SMS
server
7,333,807 77D16FBF2DF3287DA4FE978076E4612D Pre-
installed in
the
gateway
52,570,241
19,739,009 03226D5D55842B5BFE4274BAC9E5EA39 Pre-
3,262,569 E4184EDC6BDF5F81185AACEBC6EEC77B To be
5D65AD452675DBB3EC67D1441A3A100D Pre-
installed in
the
gateway
installed in
the
gateway
installed
only if
Microsoft
SMS is used
6 NLG-
GatewayCommon-
1.2.42.rpm
Documentation
Please note that there are no new revisions of the user manuals for this product
release (1.2.42). All documents associated with the previous release (1.2.25) are still
applicable. All product changes that are visible to the IT administrator and end user
are covered in the respective Release Notes documents.
The following list contains all user documents that are available for consultation in
addition to the Administrator and End-User Release Notes:
This document highlights all known issues of Release 1.2.42 of the OmniAccess 3500
NLG and all incremental changes introduced in Release 1.2.42 with respect to Release
1.2.25.
Installation/Upgrade Instructions
•Please refer to the OmniAccess 3500 Nonstop Laptop Guardian Release 1.2
Gateway Installation Guide for detailed instructions regarding the installation
and initial configuration of the OmniAccess 3500 NLG gateway.
• To achieve proper operation of all components of the OmniAccess 3500 NLG
platform, the installed version number must be the same for the laptop client
software, the OmniAccess 3500 NLG card firmware, and the OmniAccess 3500
NLG gateway software.
System Requirements
• End user laptop:
o OS: Microsoft Windows XP SP2
o Processor speed: 1 GHz or higher
o RAM: 512 MB or higher
o PCMCIA CardBus slot
o No VPN client installed in the laptop
o Trusted Platform Module (TPM) disabled if installed in the laptop.
• Access to management system GUI:
o Internet Explorer 6.0 or above or Mozilla Firefox 3.0 or above, installed in any
computer with network access. The 1024x768 screen resolution (normal font
size) is recommended.
Contacting Technical Support
Please contact your Service Provider to address any technical issue that you may
encounter in the operation of the OmniAccess 3500 NLG platform. If instructed by your
Service Provider to contact Alcatel-Lucent for technical support, please refer to the
following contact information:
4
Region Phone Number
North America 1-800-995-2696
Page 5
Administrator Release Notes
Latin America +1-877-919-9526
Europe +33-388-55-69-29
Asia Pacific +65-6240-8484
Other International +1-818-878-4507
Email: support@ind.alcatel.com
Internet: Customers with Alcatel-Lucent service agreements may open cases 24 hours
a day via Alcatel-Lucent’s support web page at: service.esd.alcatel-lucent.com.
New Features
This product release (1.2.42) does not introduce new features compared to the
previous release (1.2.25). Please refer to the previous revision (25.01) of this
document for a list of the features that are included in this product release.
Issues Fixed
This section lists known issues of Release 1.2.25 that have been fixed in Release
1.2.42:
1. Internal tracking ID: 775
Problem Description: It is not possible to configure a secondary RADIUS server (if
RADIUS is used) for administrators and end users.
2. Internal tracking ID: 1127
Problem Description: If the user's “full name” is missing and you ask for the user
status then the operation fails.
3. Internal tracking ID: 1277
Problem Description: While importing a user who is already present in the
management system database, a message saying “base key foreign key integrity
constraint” is displayed.
4. Internal Tracking ID:
Problem Description: The card firmware cannot be upgraded automatically when
a new version of the OmniAccess 3500 NLG client software is installed in the
laptop.
Resolution Details: When a new version of the OmniAccess 3500 NLG client
software is installed in the laptop, it is now no longer necessary to manually flash
the OmniAccess 3500 NLG card with the corresponding firmware version. Instead,
after the end user installs the new client software in the laptop, the client
software automatically recognizes the card firmware version the next time the
card is inserted again, and replaces it if it is obsolete. No intervention is required
from the end user or the IT administrator.
Problem Description: The OmniAccess 3500 NLG client software cannot be
uninstalled.
Resolution Details: To prevent the end user from bypassing the security and
management controls enforced by the OmniAccess 3500 NLG, the end user is
normally not allowed to uninstall and remove the OmniAccess 3500 NLG client
software from the laptop. However, if the IT administrator concludes that the
client software must be uninstalled, Release 1.2.42 now enables uninstallation of
the client software by the end user under administrative control. The controlled
uninstallation procedure works as follows:
o The end user calls the IT helpdesk.
o The IT helpdesk administrator on the phone instructs the end user to start
the uninstallation of the OmniAccess 3500 NLG client software using the AddRemove Programs feature of Windows.
o A pop-up window appears on the screen asking for the uninstallation
password. The window displays the current date and time and a screen-count
number. The administrator needs this information to generate a One-Time
Uninstallation Password (OTUP).
o To generate the OTUP on the management system GUI, the administrator
clicks Users on the left-hand main menu, selects the desired user, clicks
Configure, clicks Generate One Time Password, enters the information
found by the end user on the pop-up window, and clicks GetPW. Please note
that the OTUP is user-specific and can be used only once within two hours of
its generation. The password is not case-sensitive and does include the
hyphens that appear on the management system GUI window.
o The end user resumes the uninstallation process by entering the password
supplied by the administrator.
The OmniAccess 3500 Nonstop Laptop Guardian Release 1.2.42 End-User Release Notes document contains detailed message flows and screen shots.
6. Internal Tracking ID:
Problem Description: A redundant RADIUS server for end-user authentication is
not supported.
Resolution Details: Release 1.2.42 supports two RADIUS servers (primary and
secondary). All authentication requests are first sent to the primary RADIUS
server. If the primary server does not respond to a request, the same request is
forwarded to the secondary RADIUS server. The secondary RADIUS server becomes
now the primary RADIUS server and maintains this role until its first failure to
respond to a request. To configure the primary and secondary RADIUS servers on
the management system GUI the administrator clicks Gateway on the left-hand
main menu, clicks Edit Gateway Settings, enters the IP Address, Port, and
Secret values for the two servers, and clicks Save.
Known Issues
This section lists known issues of Release 1.2.42 of the OmniAccess 3500 NLG.
6
Page 7
Administrator Release Notes
Gateway
INSTALLATION AND CONFIGURATION
1. Internal tracking ID: 349
Problem Description: Change of super admin id is not forced when gateway is
installed.
Impact: Gateway may continue to have the default admin password.
Workaround/s: Make sure that you change the admin password after installation
of the Gateway. This step is also recommended in the Gateway Installation Guide.
2. Internal tracking ID: 507
Problem Description: Same or overlapping IP addresses can be configured for the
Cards and Laptops address pools.
Impact: Some clients may fail to connect.
Workaround/s: Verify the configured values before entry.
3. Internal tracking ID: 1818
Problem Description: The Gateway Configuration and Restore utility does not
restore the pre-existing values of connectivity and OTP timeout (per user) and of
radio timeout (per user group). Instead, the default values are set after a
restoration (90 days).
Impact: In case of configuration restore (if the gateway fails) the connectivity,
radio, and OTP timeout are set to the maximum value permitted.
Workaround/s: After configuration restore, make sure to configure these values
correctly for all users and user groups.
4. Internal tracking ID: 655
Problem Description: There is no mechanism for the recovery of a lost super
administrator’s password.
Impact: The super admin account may become unusable if the password is lost.
Workaround/s: Store the super administrator’s password in a safe place. Also
create immediately upon gateway installation at least one more administrator
account in addition to the super administrator one, so that the administrative
functions can be carried out using the other account.
HIGH AVAILABILITY
5. Internal tracking ID:
Problem Description: There is no redundancy for the gateway.
Impact: If the OmniAccess 3500 NLG gateway fails, no client can avail the service.
Workaround/s: Keep a backup gateway ready. Periodically backup the
configuration on the active gateway (automatic procedure). Restore the
configuration on the backup gateway if the active gateway fails.
Problem Description: It is not possible to configure a secondary Active Directory
server or domain name.
Impact: If the configured Active Directory server fails then the authentication of
the end users will start failing.
Workaround/s: Use the most reliable Active Directory server or consider the
virtual server option.
USER INTERFACE
7. Internal tracking ID: 993
Problem Description: The certificate used for the management system GUI (HTTPS
server) cannot be uploaded by the customer.
Impact: Every time the management system GUI is accessed, the certificate
warning will appear to the administrator.
Workaround/s: Install the CA certificate on the client computer that is used for
accessing the management system GUI.
8. Internal tracking ID: 96
Problem Description: On the management system GUI, the browser’s back button
does not work.
Impact: Inconvenience to the administrator; accidentally hitting the back button
will logout the administrator.
Workaround/s: Always use the pane menu on the left-hand side of the GUI window
to browse through the management system GUI sections.
9. Internal tracking ID: 755
Problem Description: Simultaneous multiple logins can be made using the same
administrator account.
Impact: Accountability issues. The account may be misused as well.
Workaround/s: Discourage this practice by creating individual administrator
accounts for each administrator.
10. Internal tracking ID: 1834
Problem Description: Some of the management system GUI windows, specifically
the Gateway Configuration window, may appear jumbled up.
Impact: Accountability issues. Not able to carry out the desired configuration
changes.
Workaround/s: Use of Internet Explorer 6.0 with 1024x768 screen resolution shall
fix this problem.
OPERATION
11. Internal tracking ID: 1840
Problem Description: Sometime the user status information, including indication
of whether the card is currently inside or outside the laptop, is not shown
correctly. If the tunnel is not active, the status shown is the last known at the
8
Page 9
Administrator Release Notes
time of the request and is only updated after completion of the remote wakeup
procedure.
Impact: Incorrect status information.
Workaround/s: If the status information is critical, always recheck the desired
status entry again 10 minutes after issuing the status request.
POLICY OBJECTS
12. Internal tracking ID: 805
Problem Description: Users within a user group cannot be modified.
Impact: Accountability issues. The method for modifying individual user
configurations within a user group is convoluted.
Workaround/s: Instead of editing the user group, change the user group for the
desired users.
AUTO VPN
13. Internal tracking ID:
Problem Description: AES is not supported by the encryption acceleration
hardware in the card. However the AES algorithm will automatically work using
the software-based encryption. The encryption acceleration hardware in the
gateway supports AES.
Impact: Reduced throughput for the clients making use of AES.
Workaround/s: Avoid using AES if not required.
14. Internal tracking ID: 1024
Problem Description: If RADIUS is used for end-user authentication then any user
having a valid RADIUS account can use the OmniAccess 3500 MLG-enabled laptop.
Impact: This is not a bug. Some enterprises may like it this way. However, this
behavior may be an issue for enterprises that want to have a strict binding
between the laptop, the OmniAccess 3500 NLG card, and the user.
Workaround/s: If you want to have a strict binding between the laptop, the
OmniAccess 3500 NLG card, and the user, do not use the RADIUS-based
authentication and use instead the default Active-Di rectory authentication
method.
15. Internal tracking ID: 1471
Problem Description: Switching from the default 3DES encryption to AES
encryption does not work.
Impact: Because of the configuration issue, it is not possible to use AES in this
release.
Workaround/s: There is no known workaround at the moment. Continue using
3DES in place of AES.
Problem Description: It is not possible to change the authentication method from
RADIUS (Lax or Strict) to Domain (Active Directory) after the RADIUS selection has
been saved in the initial configuration.
Impact: Once RADIUS is selected, Domain is no longer an available option. Trying
to switch from RADIUS to Domain will compromise the configuration of all
OmniAccess 3500 NLG components.
Workaround/s: Make a conclusive decision about the authentication method
(RADIUS or Domain) before installing the gateway.
17. Internal Tracking ID: 1892, 1893
Problem Description: Switching the authentication method from Domain to RADIUS
(Lax or Strict) when the RADIUS configuration parameters are already populated
or changing the configuration of the RADIUS server parameters when a secondary
RADIUS server is configured may not work.
Impact: Once an authentication method is selected and configured, changing any
portion of the configuration may compromise the configuration of all OmniAccess
3500 NLG components.
Workaround/s: In general, it is always preferable to make a conclusive decision
about the authentication method (RADIUS or Domain) and its configuration before
installing the gateway. However, in the specific cases outlined in the Problem
Description the following procedure can be used to ensure a successful update of
the configuration parameters for the authentication method:
o Click Gateway and Edit Gateway Settings.
o On the Gateway Configuration window, enter incorrect values for all RADIUS-
server fields (IP address, port, secret).
o Save the incorrect values. The gateway will reboot.
o Click Gateway and Edit Gateway Settings.
o On the Gateway Configuration window, enter the desired values for all
RADIUS-server fields (IP address, port, secret).
o Save the correct configuration. The gateway will reboot.
o Check the Rules table in the Connection Manager settings (click Configure
Advanced Settings and click Rules to view the Gateway Configure -> Rule
Information window). The Rule table may show two duplicate rules (106 and
108). This is not a problem if the two rules are identical.
ACTIVE DIRECTORY IMPORT
18. Internal tracking ID: 1305
Problem Description: The display name of the user is not imported.
Impact: Difficult to identify the imported users.
Workaround/s: Enter the display name manually for the imported users.
PERSONAL FIREWALL
19. Internal tracking ID: 1001
10
Page 11
Administrator Release Notes
Problem Description: If a change is made to a host or service group that is already
used in a personal firewall policy then the changes are not reflected in the policy.
Impact: Desired changes are not reflected in the personal firewall policy.
Workaround/s: Remove the host or the service group from the policy. Make the
changes to the host/service group and then reapply the host/service group to the
policy.
SMSINTEGRATION
20. Internal tracking ID: 734
Problem Description: Patches available in the card are not applied to the laptop if
the gateway is not accessible.
Impact: Application of patches may get delayed.
Workaround/s: Configure the connectivity timeout to a lower value. This will
ensure that if the laptop is not connected to the enterprise network then it is in
locked state, causing no danger due to pending patch.
21. Internal tracking ID: 735
Problem Description: The patch advertisement may erroneously be declared
successful while the patch is in transit.
Impact: The SMS Administrator may get a false notification that the patch has
been applied while it is in transit.
Workaround/s: Configure the connectivity timeout to a lower value and encourage
the end user to remain always connected. This will reduce the probability of
incorrect notification.
22. Internal tracking ID: 1571
Problem Description: Patches delivered to the laptop do not get installed. This
happens because the virtual IP address of the laptop is not registered with the
DNS and therefore the SMS client on the laptop is not able to connect to the SMS
management point (residing either on the SMS server or on a separate server).The
SMS management point hence never gets to know that a patch is waiting to be
installed.
Impact: The patches sent to the laptop may not be applied.
Workaround/s: For the patches to be delivered successfully, the admin shall take
care of following:
o Add to the DNS a reverse lookup zone for the virtual IP address range
assigned to the laptops.
o Add the virtual IP address range assigned to the laptops to the site
Problem Description: PatchLink Update patches that have already been
downloaded to the card are not applied to the laptop until the tunnel to the
gateway is established.
Impact: Application of patches may be delayed.
Workaround/s: Configure a low value for the connectivity timeout. This will
ensure that the laptop locks shortly after disconnecting from the enterprise
network, minimizing the risk associated with the delayed application of a patch.
24. Internal tracking ID: 1885
Problem Description: The status of the AWT facility is not properly reflected in
the management system GUI.
Impact: Once AWT is enabled it is not possible to disable it because the
management system GUI will not show the option of disabling it.
Workaround/s: There is no workaround for this. However there is no harm in
leaving the AWT enabled all the time.
ANTI-TAMPERING
25. Internal tracking ID: 866
Problem Description: It is possible to uninstall the OmniAccess 3500 NLG client
software from the laptop by restoring Windows to a previous checkpoint.
Impact: The end user may get rid of the security and management controls
enforced by the OmniAccess 3500 NLG.
Workaround/s: To prevent this from happening, please delete all previous
checkpoints after installing the OmniAccess 3500 NLG software.
26. Internal tracking ID: 1848
Problem Description: The One-Time Password issued for one user also works for
another user.
Impact: Not a desirable behavior from a security perspective.
Workaround/s: This happens if the base password configured for both users is the
same. Please make sure that a unique base password is configured for each user.
In the future the base password will be generated automatically.
Client
Please refer to the OmniAccess 3500 Nonstop Laptop Guardian Release 1.2.42 End-User
Release Notes for information on known issues for the OmniAccess 3500 NLG client
(card and laptop).