Aiphone JOS-1VW, JOS-1FW, JOS-1AW, JO-1MDW Installation Manual

0 (0)

Installation Manual

JO-1MDW (Master monitor station)

JOS-1AW (A set including JO-1MDW, JO-DA and power supply)

JOS-1VW (A set including JO-1MDW, JO-DV and power supply)

JOS-1FW (A set including JO-1MDW, JO-DVF and power supply)

Issue date: Dec. 2018 FK2603 A P1218 HZ 61036

Part names

Package contents

 

 

 

JO-1MDW

JO-1MDW JOS-1AW

JOS-1VW

JOS-1FW

 

 

JO-1MDW

 

 

 

 

RESET button

 

JO-DA

 

 

Press this button to

microSD card

 

reboot the station.

slot

 

 

 

 

JO-DV

icrophone

Speaker

 

 

 

Status LED

 

 

 

 

 

JO-DVF

 

Camera-angle

JO-DA

 

 

 

 

 

 

adjustment

Surface mount

 

 

 

 

 

 

The camera-angle

 

 

 

 

 

 

behind the panel

Camera

 

 

 

 

 

 

 

+17°

 

 

 

 

 

 

 

Microphone

 

Flush mount

Special

 

 

 

+7° (Upward)

 

 

 

 

Illumination sensor

 

back box

screw × 4

 

 

 

0° (Center)

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

-7°

Speaker

 

 

 

supply

 

 

 

Camera-angle

Call button with white light LED

 

or

 

 

 

 

 

 

 

adjustment switch

Drainage holes

PS-1820, PS-1820S,

PS-1820DM

 

 

 

Locator LED (red)

 

 

 

Holes for discharging rain water from inside the unit.

PS-1820UL, PS-1820BF

 

 

 

 

 

 

Do not obstruct these holes.

 

 

Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

manual

 

JO-DV

 

 

 

 

 

 

Information sheet

 

 

 

 

Surface mount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera

 

 

Special

 

 

 

Illumination

Microphone

 

 

screwdriver

 

 

White light LED

 

 

Special screwdriver

 

 

sensor

 

 

 

 

 

Speaker

 

 

(Hexagonal wrench)

 

 

 

Name plate

 

 

Transparent

 

Call button

(with backlight)

 

 

name plate × 2

 

 

The backlight is always lit while

 

 

 

 

 

 

 

 

the power is on.

NOTES:

 

 

 

 

 

 

Drainage holes

Mounting and wood mounting screws not included.

 

 

 

Vandal resistant front panel Do not obstruct.

microSDHC card is not included. Please purchase separately.

 

 

 

 

For details on the power supply, see the installation manual of the power supply separately.

 

JO-DVF

 

Precautions

 

 

 

 

Surface mount

Illumination sensor

Camera

Microphone

White light LED Speaker

Name plate

(with backlight) Call button

Vandal resistant front panel

1.Do not dismantle or alter the unit. Fire or electric shock could result.

2.Do not use power supply with a voltage other than specified. Fire or electric shock could result.

3.Do not open the case. High voltage is present internally. Electric shock could result.

4.Do not install two power supplies in parallel to single input. Fire or damage to the unit could result.

5.Do not connect any terminal on the unit to AC power line. Fire or electric shock could result.

6.For power supply, use Aiphone power supply model specified for use with system.

Negligence could result in injury to people or damage to property.

1. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit.

2. Before turning on power, make sure wires are not crossed or shorted. Fire or electric shock could result.

3. Install the device in a position where it will not easily be brushed against by somebody’s shoulder, etc.

Failure to do so could result in injury.

4. Do not place your ear close to the speaker during use. cause hearing damage.

for mounting

1.Installing the device in the following locations could cause malfunction:

*Locations exposed to direct sunlight

*Locations that get hot

Close to a heater, boiler, etc.

*Locations where there is risk of exposure to liquid, dust, oil, or chemicals

*Locations with high humidity Bathroom, basement, greenhouse, etc.

*Locations with low temperature

Inside a cold storage warehouse, the front of a cooler, etc.

*Locations directly exposed to steam or oil smoke Next to heating devices or a cooking space, etc.

*Sulphurous environments such as a hot spring area

*Locations close to the sea or directly exposed to sea breeze

2.In 50Hz regions, if a strong fluorescent light shines directly into the camera, it may cause the image to flicker. Either shield the camera from the light or use an inverter fluorescent light.

3.For running cables, separate them for audio/video and door release and keep them more than 10cm (3-15/16″) away from each other.

4.When using an existing wiring, depending on the type of wiring, it may not operate the system. In case of that, change wiring is required.

5.Do not use the impact driver for mounting. Damage to the unit could result.

6.Avoid installing the master monitor station in concave space of a wall to prevent disconnection

.

Precautions

1.Install low-voltage lines at least 30cm (11″) away from high-voltage lines (AC100V-240V), especially inverter air conditioner wiring. Failure to do so may result in interference or malfunction.

2.When installing or using the device, give consideration to the privacy rights of subjects, as it is the responsibility of the system owner to post signs or warnings in accordance with local

.

1.Please note that images and illustrations depicted in this manual may differ from the actual ones.

2.Using a mobile phone or professional-use radio equipment such as walkie-talkie close to the system may cause a malfunction.

3.In areas where broadcasting station antennas are close by, the intercom system may be affected by radio frequency interference.

4.Do not install the unit close to an electrical appliance or water heater using a dimmer or inverter, a remote controller of floor heating, etc. Failure to do so may generate a noise causing a malfunction of the unit.

5.When warm indoor air flows into the unit, dew condensation may be caused by a temperature difference between indoors and outdoors. It is recommended to cover openings on the unit such as cable incoming holes to avoid condensation.

6.In areas where microwave is close by, the intercom system may be affected by radio

interference.

Aiphone JOS-1VW, JOS-1FW, JOS-1AW, JO-1MDW Installation Manual

Installation

Cable

Use PE (polyethylene)-insulated PVC jacket cable.

Parallel or jacketed 2-conductor, mid-capacitance non-shielded cable is recommended.

Never use individual conductors, twisted pair cable or coaxial cable.

1. Line up solid and

2. Overlap more than half

stranded conductors,

of the width and twist

and crimp them.

them at least twice.

1. Twist the stranded

2. Bend the tip and solder it.

3. Overlap more than half of

conductor around the

Make sure no lead wire

the width and twist them at

solid conductor at least

sticks out.

least twice.

three times.

 

 

When using existing cables

Check for short circuit and disconnection before installation.

Ø0.8-1.2mm, 100m

Loop resistance value: 6Ω or less

Disconnection check (6Ω or less)

Connect the ends of one side and make a measure at the other side with a tester.

Short circuit check: Ω (Infinity)

Measure the resistance of this loop.

Wiring method, wiring distance

JO-DA

JO-DV

A

 

 

 

 

JO-1MDW

 

 

 

 

IER-2

 

 

 

 

 

 

B

C

 

JO-DVF

 

 

 

 

 

PS18 : PS-1820, PS-1820S, PS-1820UL,

 

 

 

PS-1820BF, PS-1820DM

 

Ø 0.65 mm

22 AWG

Ø 0.8-1.2 mm

20-16 AWG

A

50 m

165′

100 m

330′

B

5 m

16′

10 m

33′

C

50 m

165′

150 m

490′

Mounting locations

JO-DA, JO-DV, JO-DVF

Do not install the door station in any of the following locations where lighting or the ambient environment could impact the camera of the unit.

Where lights will

Where the sky

be shining directly

fills much of the

into the camera

background

night time

 

 

Sky

JO-1MDW

Where the

Where sunlight or

background of the

other strong light

subject is white.

sources will shine

 

directly into the

 

camera

White

 

wall

 

Do not install the master monitor station at a location exposed to direct sunlight.

Avoid installing the master monitor station in a concave space of a wall to prevent audio distortion.

Make sure to leave at least the specified spaces on all sides to prevent malfunction and audio distortion.

20 cm (7′ 9″)

20 cm (7′ 9

20 cm (7′ 9″)

Do not embed the master monitor station inside a wall.

The reset button is on the left side and the microSDHC card slot is on the right side of the master monitor station. Be sure to install the station at a location where all buttons can be reached by hand.

Install the master monitor station more than 3meters apart from all wireless equipment.

Mounting positions and image view area

JO-DA, JO-DV, JO-DVF

 

Vertical

Camera angle: 0°

 

 

 

 

Approx. 1,800 mm (5′ 11″)

500 mm (20″)

Approx. 550 mm

Unit

 

(1′ 9″)

 

 

center

 

Approx. 1,250 mm

1,500 mm

 

 

(4′ 1″)

Approx. 950 mm

 

 

500 mm (5′)

(3′ 1″)

 

 

(20″)

JO-DA only : Refer to the diagrams below when the camera angle is changed with the adjustment switch.

Camera angle: 7°

Camera angle: 17°

Camera angle: −7°

 

 

 

 

 

(When the station is at a high position

 

 

 

 

 

due to a step)

 

Approx. 1,750 mm (5′ 9″)

Approx. 1,900 mm (6′ 4″)

Approx. 1,900 mm (6′ 4″)

 

 

Approx. 600 mm

 

Approx. 600 mm

 

Approx. 650 mm

Unit

 

 

(2′ 2″)

 

(2′)

center

(2′)

 

Unit

Unit

 

 

 

 

 

 

center

Approx.

center

Approx.

1,500 mm

Approx.

 

 

 

 

 

 

1,300 mm

 

1,300 mm

1,250 mm

1,300 mm

1,150 mm

 

(5′)

(3′ 9″)

500 mm

(4′ 4″)

(4′ 1″) 500 mm

(4′ 4″)

(4′ 4″)

500 mm

 

(20″)

 

(20″)

 

(20″)

 

150 mm (5″)

 

 

 

 

 

Wi-Fi installation requirements

The master monitor station incorporates wireless LAN antennas. The Wi-Fi signal may not reach the master monitor station depending on the installation environment such as wall materials or the number of walls. Make sure the master monitor station receives a Wi-Fi signal successfully before installing the master monitor station. If the Wi-Fi signal does not reach the master station, change the installation location of the router or the master station.

 

Good

Good

 

No Good

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Router

Master

 

 

 

monitor

 

 

station

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Partition masonry walls

 

 

Reinforced concrete walls

 

 

 

Wood walls

 

 

Load-bearing walls

 

 

 

 

Plasterboard walls

 

 

Stone walls

 

 

 

 

 

 

 

 

Metal walls

 

 

 

 

 

 

 

 

Loading...