* For instruments with higher Serial Numbers, a change page may be included.
Agilent Part No. 66000-90001 Printed in USA: June , 1997
Microfiche Part No. 66000-90002 Update April 2000
CERTIFICATION
Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory. Agilent
Technologies further certifies that its calibration measurements are traceable to the United States National Bureau of
Standards, to the extent allowed by the Bureau’s calibration facility, and to the calibration facilities of other International
Standards Organization members.
WARRANTY
This Agilent Technologies hardware product is warranted against defects in material and workmanship for a period of three
years from date of delivery. Agilent Technologies software and firmware products, which are designated by Agilent
Technologies for use with a hardware product and when properly installed on that hardware product, are warranted not to
fail to execute their programming instructions due to defects in material and workmanship for a period of 90 days from date
of delivery. During the warranty period Agilent Technologies will, at its option, either repair or replace products which
prove to be defective. Agilent Technologies does not warrant that the operation of the software, firmware, or hardware shall
be uninterrupted or error free.
For warranty service, with the exception of warranty options, this product must be returned to a service facility designated
by Agilent Technologies. Customer shall prepay shipping charges by (and shall pay all duty and taxes) for products returned
to Agilent Technologies for warranty service. Except for products returned to Customer from another country, Agilent
Technologies shall pay for return of products to Customer.
Warranty services outside the country of initial purchase are included in Agilent Technologies product price, only if
Customer pays Agilent Technologies international prices (defined as destination local currency price, or U.S. or Geneva
Export price).
If Agilent Technologies is unable, within a reasonable time to repair or replace any product to condition as warranted, the
Customer shall be entitled to a refund of the purchase price upon return of the product to Agilent Technologies.
LIMITATION OF WARRANTY
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Customer,
Customer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental
specifications for the product, or improper site preparation and maintenance. NO OTHER WARRANTY IS EXPRESSED
OR IMPLIED. AGILENT TECHNOLOGIES SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
EXCLUSIVE REMEDIES
THE REMEDIES PROVIDED HEREIN ARE THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDIES. AGILENT
TECHNOLOGIES SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY.
ASSISTANCE
The above statements apply only to the standard product warranty. Warranty options, extended support contracts, product
maintenance agreements and customer assistance agreements are also available. Contact your nearest Agilent
Technologies Sales and Service office for further information on Agilent Technologies’ full line of Support Programs.
2
SAFETY SUMMARY
The following general safety precautions must be observed during all phases of operation, service, and repair of this
mainframe. Failure to comply with these precautions or with specific warnings elsewhere in this guide violates safety
standards of design, manufacture, and intended use of the mainframe. Agilent Technologies assumes no liability for the
customer’s failure to comply with these requirements.
BEFORE APPLYING POWER.
Verify that the product is set to match the available line voltage and the correct fuse is installed.
GROUND THE MAINFRAME.
This product is a Safety Class 1 instrument (provided with a protective earth terminal). To minimize shock hazard, the mainframe must
be connected to an electrical ground. The mainframe must be connected to the ac power supply mains through a three-conductor power
cable, with the third wire firmly connected to an electrical ground (safety ground) at the power outlet. Any interruption of the protective
(grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal
injury.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE.
Do not operate the instrument in the presence of flammable gases or fumes.
KEEP AWAY FROM LIVE CIRCUITS.
Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by qualified
service personnel. Do not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even
with the power cable removed. To avoid injuries, always disconnect power, discharge circuits and remove external voltage sources before
touching components.
DO NOT SERVICE OR ADJUST ALONE.
Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
DO NOT EXCEED INPUT RATINGS.
This mainframe is equipped with a power line filter to reduce electromagnetic interference and must be connected to a properly grounded
receptacle to minimize electric shock hazard. Operation at line voltages or frequencies in excess of those stated on the line rating label
may cause leakage currents in excess of 5.0 mA peak.
SAFETY SYMBOLS.
Instruction manual symbol: the product will be marked with this symbol when it is necessary for the user to refer to the
instruction manual (refer to Table of Contents) .
The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly
performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING sign until the
indicated conditions are fully understood and met.
The CAUTION sign denotes a hazard. It calls attention to an operating procedure, or the like, which, if not correctly
performed or adhered to, could result in damage to or destruction of part or all of the product. Do not proceed
beyond a CAUTION sign until the indicated conditions are fully understood and met.
DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT.
Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the
instrument. Return the instrument to an Agilent Technologies Sales and Service Office for service and repair to ensure that safety features
are maintained.
Mainframes that appear damaged or defective should be made inoperative and secured against unintended operation until they can be
repaired by qualified service personnel.
3
SAFETY SUMMARY (continued)
GENERAL: Any LEDs used in this product are Class 1 LEDs as per IEC 825-1.
ENVIRONMENTAL CONDITIONS:
This instrument is intended for indoor use in an installation category II, pollution degree 2 environment. It is
designed to operate at a maximum relative humidity of 95% and at altitudes of up to 2000 meters. Refer to the
specifications tables for the ac mains voltage requirements and ambient operating temperature range.
SAFETY SYMBOL DEFINITIONS
SymbolDescriptionSymbolDescription
Direct currentTerminal for Line conductor on permanently
installed equipment
Alternating currentCaution, risk of electric shock
Both direct and alternating currentCaution, hot surface
Three-phase alternating currentCaution (refer to accompanying documents)
Earth (ground) terminalIn position of a bi-stable push control
Protective earth (ground) terminalOut position of a bi-stable push control
Frame or chassis terminalOn (supply)
Terminal for Neutral conductor on
permanently installed equipment
Terminal is at earth potential
(Used for measurement and control
circuits designed to be operated with
one terminal at earth potential.)
Herstellerbescheinigung
Diese Information steht im Zusammenhang mit den Anforderungen der
Maschinenläminformationsverordnung vom 18 Januar 1991.
* Schalldruckpegel Lp <70 dB(A) * Am Arbeitsplatz * Normaler Betrieb
* Nach EN 27779 (Typprüfung).
Manufacturer’s Declaration
This statement is provided to comply with the requirements of the German Sound Emission Directive,
from 18 January 1991.
* Sound Pressure Lp <70 dB(A) * At Operator Position * Normal Operation
* According to EN 27779 (Type Test).
Off (supply)
Standby (supply) - Units with this symbol are not
completely disconnected from ac mains when
this switch is off. To completely disconnect the
unit from ac mains, either disconnect the power
cord or have a qualified electrician install an
external switch.
4
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacturer's Name:Agilent Technologies, Inc.
Manufacturer's Address:140 Green Pond Road
Rockaway, New Jersey 07866
U.S.A.
declares that the Product
Product Name:Modular Power System mainframe and modules
EMC:CISPR 11:1990 / EN 55011:1991 - Group 1 Class A
IEC 801-2:1991 / EN 50082-1:1992 - 4 kV CD, 8 kV AD
IEC 801-3:1984 / EN 50082-1:1992 - 3 V / m
IEC 801-4:1988 / EN 50082-1:1992 - 0.5 kV Signal Lines
1 kV Power Lines
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC and carries the CE-marking accordingly.
Note 1: The product family was introduced prior to 12/93.
New Jersey January 1997
Location Date Bruce Krueger / Quality Manager
European Contact: Your local Agilent Technologies Sales and Service Office or Agilent Technologies GmbH,
Department TRE, Herrenberger Strasse 130, D-71034 Boeblingen (FAX:+49-7031-14-3143)
Printing History
The current edition of this guide is indicated below. Reprints of this guide containing minor corrections and updates may
have the same printing date. New editions are identified by a new printing date and, in some cases, by a new part number.
A new edition incorporates all new or corrected material since the previous edition. Changes to the guide occurring
between editions are covered by change sheets shipped with the guide. Also, if the serial number prefix of your mainframe
is higher than those listed on the title page of this guide, then it may or may not include a change sheet. That is because
even though the higher serial prefix indicates a design change, that change may not affect the content of the guide.
Edition 1 ... October, 1991 (Agilent Model 66000A)
may be photocopied, reproduced, or translated into another language without the prior consent of Agilent Technologies.
The information contained in this document is subject to change without notice.
Options and Parts .......................................................................................................................................10
Power Cord Installation..............................................................................................................................14
Location and Cooling.................................................................................................................................15
Digital Connections....................................................................................................................................22
3-4.Examples of the Remote Inhibit Function..............................................................................25
Tables
1-1.Specifications and Supplemental Characteristics............................................................................11
7
1
General Information
Introduction
This guide describes how to install the Agilent 66000A Modular Power System (MPS) Mainframe. It includes the
following information:
■ specifications and operating characteristics
■ connecting the power cord to the mainframe
■ setting the address and frame switches
■ installing modules in the mainframe
■ mainframe rear panel connections
Mainframe turn-on and checkout procedures are included with the module manual since an installed module is required to
properly check out mainframe operation. Refer to the module User’s Guide for more information.
Related Documents Agilent Part No.
Programming Guide for Agilent Series 66lxxA MPS Power Modules 5959-3362
Installation Guide for DC Module Connectors 5959-3366
User’s Guide for Agilent 66lxxA Power Modules 5959-3360
Service Guide for Agilent Series 66lxxA MPS Power Modules 5959-3364
Service Guide for Agilent 66000A Modular Power System Mainframe 66000-90003
Quick Reference Card for optional Agilent 66001A MPS Keyboard 66001-90001
Agilent 66000A Modular Power System Product Note 5091-2497E
Safety Considerations
This mainframe is a Safety Class 1 instrument, which means that it has a protective earth terminal. That terminal must be
connected to earth ground through a power source equipped with a 3-wire ground receptacle.
Refer to the safety summary page at the beginning of this manual for general safety information. Before installation or
operation, check the mainframe and review this manual for safety markings and instructions. Safety information for specific
procedures is located at the appropriate places in this manual.
Instrument Identification
The mainframe is identified by a two-part serial number, such as 3140A-01234, on the back of the unit. The first part, or
prefix, is a number-letter combination that describes:
3140 The year and week of manufacture or last significant design change. Add 1960 to the first two
digits to determine the year. For example, 31=1991, 32=1992, etc. The last two digits specify the week
of the year (40 = the 40th week).
AThe letter indicates the country of manufacture, where A = USA.
General Information
9