ABB machinery drives
ACS355, 0.37 to 22 kW / 0.5 to 30 hp
The ABB machinery drives are
designed to be fast drives to install,
parameter
saving hours of engineering work.
They are highly compact and cost
effective and equipped with cuttingedge intelligence and an innovative
safety capability. The drives are
designed specifically to meet the
production and performance needs
of system integrators, original
equipment manufacturers (OEMs)
and panel builders, as well as the
requirements of end users in a broad
range of applications.
-set and commission. Thus
Highlights
− Worldwide availability and service
Exceptionally compact drives and
−
uniform design
− Quick commissioning with application
macros and panel assistants
− Safe torque-off function (SIL3 ) as
standard
− Sensorless vector control for
induction and permanent magnet
motors
− Built-in brake chopper
− High protection class variants for
demanding environments
Saving time in installation and
commissioning
The drive’s compact and uniform
dimensions facilitate multiple drive
solutions and cabinet installations.
Different mounting options enable
flexible installation in restricted spaces.
With the FlashDrop tool the drive
can be pre-configured in seconds
without powering the drive. The drive’s
application macros and assistants
enable fast and easy commissioning.
Saving cost with cutting-edge
intelligence and flexilibity
Up to eight pr
operations can be created in minutes
with the drive’s PC tool to reduce the
need for external PLC components.
Versatile fieldbus connectivity to most
PLCs on the market is also available.
The drive includes Safe torque-off
function as standard helping machine
builders to fulfill the latest machinery
directives.
Additional features include Speed
Compensated Stop. This makes the drive
ideal for material handling applications
that require precision stopping that is
independent of variations in process
speed. For demanding environments high
protection class variants are available in
IP66/IP67/UL Type 4X classes that are
NSF certified.
Power and voltage range
1-phase, 200 to 240 V ± 10%
−
0.37 to 2.2 kW (0.5 to 3 hp)
−
3-phase, 200 to 240 V ± 10%
0.37 to 11 kW (0.5 to 15 hp)
− 3-phase, 380 to 480 V ± 10%
0.37 to 22 kW (0.5 to 30 hp)
e-set sequences of
Options
Auxiliary I/O modules
−
- MTAC pulse encoder interface
- MREL module for additional relays
- MPOW for external auxiliary power
supply
− Fieldbus connection via optional
modules
- PROFIBUS DP
- CANopen
- DeviceNet
- Modbus
- Ethernet
- Profinet
- EtherCAT
- LonWorks
− FlashDrop tool for fast preconfiguration without powering the
drive
− DriveWindow Light PC tool for easy
parameter setting and graphical
sequence programming
− External EMC filters for category C2
compatibility
− Input chokes for IEC 61000-3-12
compatibility
Technical data and types
IP20 UL open
Ratings Type designation Frame
P
hp
I
N
2N
A
P
kW
N
1-phase supply voltage 200 to 240 V units
0.37 0.5 2.4 ACS355-01X-02A4-2 R0 202 70 161 1.1
0.75 1 4.7 ACS355-01X-04A7-2 R1 202 70 161 1.3
1.1 1.5 6.7 ACS355-01X-06A7-2 R1 202 70 161 1.3
1.5 2 7.5 ACS355-01X-07A5-2 R2 202 105 165 1.5
2.2 3 9.8 ACS355-01X-09A8-2 R2 202 105 165 1.5
3-phase supply voltage 200 to 240 V units
0.37 0.5 2.4 ACS355-03X-02A4-2 R0 202 70 161 1.1
0.55 0.75 3.5 ACS355-03X-03A5-2 R0 202 70 161 1.1
0.75 1 4.7 ACS355-03X-04A7-2 R1 202 70 161 1.3
1.1 1.5 6.7 ACS355-03X-06A7-2 R1 202 70 161 1.3
1.5 2 7.5 ACS355-03X-07A5-2 R1 202 70 161 1.3
2.2 3 9.8 ACS355-03X-09A8-2 R2 202 105 165 1.5
3 4 13.3 ACS355-03X-13A3-2 R2 202 105 165 1.5
4 5 17.6 ACS355-03X-17A6-2 R2 202 105 165 1.5
5.5 7.5 24.4 ACS355-03X-24A4-2 R3 202 169 169 2.5
7.5 10 31 ACS355-03X-31A0-2 R4 202 260 169 4.4
11 15 46.2 ACS355-03X-46A2-2 R4 202 260 169 4.4
3-phase supply voltage 380 to 480 V units
0.37 0.5 1.2 ACS355-03X-01A2-4 R0 202 70 161 1.1
0.55 0.75 1.9 ACS355-03X-01A9-4 R0 202 70 161 1.1
0.75 1 2.4 ACS355-03X-02A4-4 R1 202 70 161 1.3
1.1 1.5 3.3 ACS355-03X-03A3-4 R1 202 70 161 1.3
1.5 2 4.1 ACS355-03X-04A1-4 R1 202 70 161 1.3
2.2 3 5.6 ACS355-03X-05A6-4 R1 202 70 161 1.3
3 4 7.3 ACS355-03X-07A3-4 R1 202 70 161 1.3
4 5 8.8 ACS355-03X-08A8-4 R1 202 70 161 1.3
5.5 7.5 12.5 ACS355-03X-12A5-4 R3 202 169 169 2.5
7.5 10 15.6 ACS355-03X-15A6-4 R3 202 169 169 2.5
11 15 23.1 ACS355-03X-23A1-4 R3 202 169 169 2.5
15 20 31 ACS355-03X-31A0-4 R4 202 260 169 4.4
18.5 25 38 ACS355-03X-38A0-4 R4 202 260 169 4.4
22 30 44 ACS355-03X-44A0-4 R4 202 260 169 4.4
IP66/IP67/UL Type 4X
Ratings Type designation Frame
P
P
hp
I
N
2N
A
N
kW
3-phase supply voltage 200 to 240 V units
0.37 0.5 2.4 ACS355-03X-02A4-2 + B063 R1 305 195 281 7.7
0.55 0.75 3.5 ACS355-03X-03A5-2 + B063 R1 305 195 281 7.7
0.75 1 4.7 ACS355-03X-04A7-2 + B063 R1 305 195 281 7.7
1.1 1.5 6.7 ACS355-03X-06A7-2 + B063 R1 305 195 281 7.7
1.5 2 7.5 ACS355-03X-07A5-2 + B063 R1 305 195 281 7.7
2.2 3 9.8 ACS355-03X-09A8-2 + B063 R3 436 246 277 13
3 4 13.3 ACS355-03X-13A3-2 + B063 R3 436 246 277 13
4 5 17.6 ACS355-03X-17A6-2 + B063 R3 436 246 277 13
3-phase supply voltage 380 to 480 V units
0.37 0.5 1.2 ACS355-03X-01A2-4 + B063 R1 305 195 281 7.7
0.55 0.75 1.9 ACS355-03X-01A9-4 + B063 R1 305 195 281 7.7
0.75 1 2.4 ACS355-03X-02A4-4 + B063 R1 305 195 281 7.7
1.1 1.5 3.3 ACS355-03X-03A3-4 + B063 R1 305 195 281 7.7
1.5 2 4.1 ACS355-03X-04A1-4 + B063 R1 305 195 281 7.7
2.2 3 5.6 ACS355-03X-05A6-4 + B063 R1 305 195 281 7.7
3 4 7.3 ACS355-03X-07A3-4 + B063 R1 305 195 281 7.7
4 5 8.8 ACS355-03X-08A8-4 + B063 R1 305 195 281 7.7
5.5 7.5 12.5 ACS355-03X-12A5-4 + B063 R3 436 246 277 13
7.5 10 15.6 ACS355-03X-15A6-4 + B063 R3 436 246 277 13
X within the type code stands for E or U.
E = EMC filter connected. U = EMC filter disconnected.
H2 = Height with fastenings but without clamping plate.
H = Height, W = Width, D = Depth
B063 = IP66/IP67/UL Type 4X enclosure
IP20 UL open
size
H2mmWmmDmmWeight
IP66/IP67/UL Type 4X
size
HmmWmmDmmWeight
kg
kg
Mains connection
Voltage and power
connection
1-phase, 200 to 240 V ±10%:
0.37 to 2.2 kW (0.5 to 3 hp)
3-phase, 200 to 240 V ±10%:
0.37 to 11 kW (0.5 to 15 hp)
3-phase, 380 to 480 V ±10%:
0.37 to 22 kW (0.5 to 10 hp)
Frequency
48 to 63 Hz
Motor connection
Voltage
Frequency
Overload capacity
Switching frequency
3-phase, from 0 to U
SUPPLY
0 to 600 Hz
1.5 x I
for 1 minute every 10 minutes
2N
At start 1.8 x I
4 (default) to16 kHz with 4 kHz steps
for 2 seconds
2N
Parameter-enabled noise cancellation function
Programmable control connections
Two analog inputs, signal
selectable
Voltage signal
Current signal
One analog output
Five digital inputs
+ 10 V, 0 (2) to 10 V
±20 mA, 0 (4) to 20 mA
0 (4) to 20 mA
12 to 24 V, PNP and NPN,
programmable DI5 0 to 16 kHz pulse train
One relay output
One digital output
NO + NC, 250 V AC/2 A, 30 V DC/0.5 A
Transistor output, 30 V DC/100 mA,
programmable 10 Hz to 16 kHz pulse train
Accuracy
24 V DC ±10%, max. 200 mA
Environmental limits
Ambient temperature
Relative humidity
Speed reference
R = 1 to 10 kΩ
Output frequency
0 to 20 mA
max. 500 Ω
24 V
Const
Speed 1
Sourcing DI confi guration
0V
(PNP) with external power supply
-10 to 40 oC (14 to 104 oF), no frost allowed
o
C (122 oF) with 10% derating
50
Lower than 95% (without condensation)
AI configuration
DIP switches
AI1
AI2
Fwd /
Rev
Start /
Stop
Fault
No fault
Safety
Switch
1 SCREEN
2 AI1
3 GND
4 +10 V
5 AI2
6 GND
7 AO
8 GND
9 +24 V
10 GND
11 DCOM
12 DI1
13 DI2
14 DI3
15 DI4
16 DI5
17 ROCOM
18 RONC
19 RONO
20 DOSRC
21 DOOUT
22 DOGND
X1C:STO
1 OUT1
2 OUT2
3 IN1
4 IN2
ON ON
0-10 V
0-20 mA
Relay output
Digital output
max. 30 V DC.
200 mA
Figure 1. Inputs and outputs configuration based on ABB standard macro and
external digital input supply voltage.
For more information please contact your local ABB
representative or visit:
www.abb.com/drives
www.abb.com/drivespartners
© Copyright 2011 ABB. All rights reserved. Specifications subject to change
without notice.
3AUA0000068579 REV B EN 7.11.2011 #15956