LOW VOLTAGE AC DRIVES
Drives for HVAC
ACH580, 1 to 350 hp
The ACH580 drive sets new
standards in both simplicity and
reliability, and ensures smooth,
energy-efficient operation of your
HVAC systems in normal and
mission-critical situations.
Leading the way in HVAC drives
Built-in features reduce on-site commissioning time,
add value to existing control systems and provide
easy diagnostics and troubleshooting.
ACH580 drives are ideal for controlling HVAC fans,
pumps, compressors, air handling units and chillers
used in hospitals, data centers, shopping centers,
tunnel ventilation, factories, office buildings, and
more.
Maximum usability
The ACH580 drive series provides common features
throughout the whole product family, making it easy
for you to install, commission, and use them for your
entire installation.
Advanced HVAC features
The drive comes with a variety of new features, such
as a new primary settings menu that allows you to
commission and program the drive based on your
application. Sleep and timed functions are built into
the software to ensure that the drive doesn’t run
when you don’t need it. Another significant feature
of the ACH580 drive to increase life and property
safety is its in-built override mode.
Highlights
• Simple to select, install and use
• Integrated HVAC-specific features
• Intuitive control panel with optional Bluetooth
capability
• Reliable connectivity with major automation and
control systems
• Based on ABB’s all-compatible drive platform
• Safe maintenance and broad service offering
—
ACH580 ultra-low harmonic drive
Overcome challenges of harmonics
Harmonics in electrical systems can be considered
as pollution of the electrical grid and can have
negative effects on equipment.
All-in-one concept
ABBs HVAC Ultra-Low Harmonic (ULH) drives have all
the harmonic mitigation technology in the drive. With
a THDi of 3% or less, there is no need for external
components to install with the drive for reducing
harmonics.
—
ACH580-01 and ACH580-31 technical data
Compliance
ACH580-01/31
ACH580-XxR
Power range
ACH580-01
ACH580-31
Input voltag e (U
ACH580-xx-xxxA-2
ACH580-xx-xxxA-4
ACH580-xx-xxxA-6
Input voltage tolerance
Phase
Power fac tor (cosφ) at nominal load
ACH580-01
ACH580-31
Efficiency at rated power
ACH580-01
ACH580-31
Frequency 48 to 63 Hz
Supported motor control Scalar and vec tor
Supported motor types Asynchronous motor, permanent magnet motor (vector), SynRM (vector)
Degree of protection UL (NEM A) Type 1, as standard
Ambient conditions -15 to +50 °C (5 to 122 °F): No frost allowed.
Harmonic mitigation
ACH580-31 Harmonics are below the limits defined in IEEE519
Control connections Two analog inputs, two analog outputs, six digital inputs including thermistor input, three
Optional I/O
extension modules
Communication extension modules Standard: BACnet MS/TP, Modbus RTU, Johnson Controls N2
PC tools Drive composer tool entry, available for free v ia ABB website
Control panel options Hand-Of f-Auto control panel (ACH-AP- H), as standard
)
1
CE, UL , cUL , CSA , and E AC
UL
1 to 350 hp (frame sizes R1 to R9)
5 to 400 hp (frame sizes R3, R6, R8, R11)
208/240V
480V
600V
+10% / -15%
3-phase (1-phase, 240 V )
0.98
1.0
98.0%
96.5%
UL (NEM A) Type 12, as option
UL (NEM A) Type 3R, as option
Output derated above +40 °C (104 °F)
relay outputs, external 24 V DC supply input, USB via control panel
CMOD -01: External 24 V DC/AC and digital I/O ex tension
CHDI-01: Six (6) 115/230V AC digital inputs and two relay outputs
Options: BACnet/IP, DeviceNet, Ethernet IP, PROFIBUS DP, LonWorks (Q3, 2019)
Drive composer tool pro
Hand-Of f-Auto control panel w ith Bluetooth (ACH-AP-W), as option
Control panels feature battery back-up
Secured operation under special conditions
The ACH580 ULH drive offers a reliable solution to
overcome these challenges as it is able to lower the
harmonic content so that sensitive equipment stay
running. In addition, the ACH580 ULH greatly reduces
the risk of generator failure when you need it the
most.
(2 x relay output and 1 x digital output)
3AXD50 000419937 RE V B 08/02/2019