York Affinity DNX, Affinity DNQ, Affinity DNZ, DNX, DNZ User Manual

...
®
USER’S, MAINTENANCE
SAFETY INFORMATION . . . . . . . . . . . . . . . 2
SYSTEM OPERATION. . . . . . . . . . . . . . . . . 2
THERMOSTATS. . . . . . . . . . . . . . . . . . . . 2
SPARK TO PILOT IGNITION
DEVICE. . . . . . . . . . . . . . . . . . . . . . . . . 2
HEATING . . . . . . . . . . . . . . . . . . . . . . . . . 2
COOLING . . . . . . . . . . . . . . . . . . . . . . . . . 3
CIRCULATING FAN . . . . . . . . . . . . . . . . . 3
INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FOR YOUR SAFETY, READ BEFORE
OPERATING. . . . . . . . . . . . . . . . . . . . . . . 3
WHAT TO DO IF YOU SMELL GAS . . . . . . 3
START-UP INSTRUCTIONS - HEATING
SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . 4
SHUTDOWN INSTRUCTION - TO TURN
OFF GAS TO APPLIANCE . . . . . . . . . . . 4
SECURE OWNER’S APPROVAL . . . . . . . . 4
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . 5
NORMAL MAINTENANCE . . . . . . . . . . . . 5
LUBRICATION . . . . . . . . . . . . . . . . . . . . . 5
GENERAL MAINTENANCE . . . . . . . . . . . 5
FILTER CARE. . . . . . . . . . . . . . . . . . . . . . 5
OUTDOOR COIL . . . . . . . . . . . . . . . . . . . 5
BURNER. . . . . . . . . . . . . . . . . . . . . . . . . . 5
TO CLEAN BURNERS . . . . . . . . . . . . . . . 5
COMBUSTION AIR DISCHARGE . . . . . . 5
CLEANING FLUE PASSAGES AND
HEATING ELEMENTS . . . . . . . . . . . . . 5
REGISTERS . . . . . . . . . . . . . . . . . . . . . . . 5
TROUBLESHOOTING . . . . . . . . . . . . . . . . . 6
BEFORE CALLING A SERVICE-
PERSON . . . . . . . . . . . . . . . . . . . . . . . . 6
REPLACEMENT PARTS . . . . . . . . . . . . . . . 6
SOME EFFICIENCY DO’S AND DONT’S . . 6
and
SERVICE INFORMATION
MANUAL
SINGLE PACKAGE
AIR CONDITIONER
GAS/ELECTRIC
The manufacturer recommends that the “User” read all sections of this manual and keep the manual for future reference.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or prop­erty damage.
- Do not store or use gasoline or other flam­mable vapors and liquids in the vicinity of this or any other appliance.
- WHA T TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
291891-YUM-A-0207
291891-YUM-A-0207
Congratulations . . .
On your purchase of one of our Single Package Air Conditioning Units. This energy efficient system has been precision designed, manufactured of high quality materials and has passed many vigorous inspections and tests to ensure years of satis­factory service.
Please read this manual thoroughly. It will help you understand your system, tell you how to operate it efficiently and how to obtain the greatest measure of comfort at the lowest operating expense.
We appreciate your interest in our products and your decision to purchase our Single Package Unit. Enjoy you r comfort.
SAFETY INFORMATION ­FOR YOUR SAFETY
Make sure that the furnace area is clear and free of com­bustible materials, gasoline and other flammable vapors and liquids.
Be sure the furnace is free and clear of insulating material. Examine the installation of the furnace for addition of insula­tion. Some insulations are combustible.
For proper operation of this fur­nace, air for combustion and ventilation is required. Make sure that these openings are not obstructed.
For lighting or shutting down this furnace, refer to the light­ing instructions provided adja­cent to the burners and also located in this manual.
A blocked vent roll-out switch is provided in the burner com­partment. This switch is a man­ual reset. If the furnace fails to operate, contact a qualified service agency.
Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the fur­nace before shutting off the electrical supply. Then call a qualified service technician.
Do not use this furnace if any part has been under water. A
flood-damaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion. A qualified service agency should be con­tacted to inspect the furnace and to replace all gas controls, control system parts, electrical parts that have be en wet or the furnace if deemed necessary.
Determine the integrity of the installation regarding the flue gas vent, the return and supply air duct, the equipment is well supported and there are no signs of deterioration. The man­ufacturer recommends that main burner, ignition de-vice and controls are inspected by a qualified furnace technician before each heating season.
This gas/electric, heating/cooling unit is designed for outdoor use and can be installed anywhere from grade level to the roof. Elec­tric air conditioning in the summer and gas heating in the winter - all from a single unit.
SYSTEM OPERATION
THERMOSTATS
Set your thermostat for either heat­ing or cooling then set it for the desired temperature. DO NOT MOVE THE THERMOSTAT RAP­IDLY ON AND OFF, OR BACK AND FORTH FROM HEAT TO COOL. THIS COULD DAMAGE YOUR EQUIPMENT.
Always allow at least 5 minutes between changes. Find the tem-
perature that is most comfortable to you, and then LEAVE YOUR THERMOSTAT ALONE. (Excep­tion is for night or vacation “set back” to conserve energy)
Manually moving the thermostat up or down will not speed up tempera­ture changes in your rooms. This only causes the thermostat switch to function at your command rather than responding to room tempera­ture.
Heat generated by devices other than the furnace may interfere with thermostat performance. There­fore, lamps, radios, television sets, etc. should not be placed near the thermostat.
SPARK TO PILOT IGNITION DEVICE
This unit is equipped with a spark to pilot ignition device. The control is designed to automatically light the burner each time the thermo­stat “calls” for heat.
Do not attempt to manu­ally light the burners. Per­sonal injury could result.
HEATING
When the thermostat calls for HEAT, the thermostat terminal “W”, “W1” or “W2” is energized, the con­trol board checks for a open pres­sure switch “PS” and closed limit switches, then energizes the com­bustion air blower.
2 Unitary Products Group
291891-YUM-A-0207
After combustion airflow is estab­lished, the air proving pressure switch “PS” closes, the ignitor is energized and the pilot valve opens igniting the pilot flame.
The flame rod senses a flame and de-energizes the ignitor opening the main gas valve and the main burners light.
30 seconds after the main burners light the circulating fan is energized at the heating speed.
When the thermostat is satisfied, terminal W is de-energized, de­energizing the ignition system clos­ing the gas valve.
After a 30 second postpurge timing period, the combustion air blower is de-energized and the heat fan off timing begins.
When this field selected heat fan off timing is completed the circulat­ing fan is de-energized.
WARNING
Flue hood surface and immediate area is designed to operate at high tempera­tures during the heating cycle. Special attention must be given to keep all human contact and debris away from this area.
V E N T O U T L E T S C R E E N
F L U E V E N T O U T L E T
A I R H O O D
If a call for “COOL” occurs, the cir­culating fan continues to run at the cool speed.
If a call for “HEAT” occurs, the cir­culating fan switches to heat speed after a 30 second delay.
When the thermostat ends the call for “FAN”, the thermostat is de­energized, de-energizing the circu­lating fan.
INPUT
The correct heat capacity of the fur­nace is regulated by the burner ori­fices and the gas pressure. The proper orifices are furnished but the gas pressure regulator must be adjusted by the installing service­man or gas company. This is a “one-time” adjustment.
FOR YOUR SAFETY, READ BEFORE OPERATING
If the limit switch “LS”, auxiliary limit switch “ALS” or the rollout switch “RS” open, the ignition sys­tem is de-energized and the gas valve closes. The combustion blower and the circulating fan are energized.
The combustion blower remains energized for the 30 second post­purge timing period if the limit switch “LS”, auxiliary limit switch “ALS” or the rollout switch “RS” contacts reset (the rollout “RS” and auxiliary limit switch “ALS” must be manually reset). The circulating fan remains energized for the selected heat delay off timing.
Normal operation of the system resumes.
WARNING
Should overheating occur, shut off the manual gas valve external to the appli­ance before shutting off the electrical supply.
WARNING
Incorrect installation of the flue vent hood could cause personal injury or property damage.
COOLING
When the thermostat calls for “COOL”, the thermostat signals the compressor and outdoor fan to run.
The circulating fan is immediately energized at cooling speed.
When the thermostat is satisfied, the compressor and outdoor fan is de-energized.
After a cool fan off delay timing of 30 seconds the circulating fan is de-energized.
CIRCULATING FAN
When the thermostat calls for “FAN”, the thermostat terminal sig­nals the circulating fan to run at the cool speed.
WARNING
If you do not follow these instructions exactly, a fire or explosion may result, causing property dam­age, personal injury or loss of life.
A. BEFORE OPERATING, smell all
around the appliance area for gas. Be sure to smell around the base of the unit because some gas is heavier than air and will settle in the area.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Unitary Products Group 3
291891-YUM-A-0207
Immediately call your gas sup­plier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
A. Use only your hand to push in or
turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service techni­cian. Force or attempted repair may result in a fire or explosion.
B. Do not use this appliance if any
part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
START-UP INSTRUCTIONS
- HEATING SYSTEM
NOTE: See General instructions for
Start-up and Shutdown of your gas heating system.
1. STOP! Read the safety informa-
tion.
2. Set the thermostat to the lowest
setting.
3. Make sure all electrical power to
the furnace is “OFF”.
4. This appliance has a device
which automatically lights the pilot and inturn, lights the burn­ers.
5. Remove burner access panel
by removing screws and lifting panel out.
6. Push the manual gas switch to
the “OFF” position.
7. Wait five (5) minutes to clear out
any gas. If you then smell gas, STOP! Follow step A in the safety information. If you don't smell gas, go to next step.
8. Push the manual gas switch to the ON position.
9. Replace the control access panel.
10.Turn on all electrical power to the appliance.
11.Set the thermostat to the desired setting.
12.If the appliance will not operate, follow the instruction “To Turn OFF Gas To Application” and call your service technician or gas supplier.
SHUTDOWN INSTRUCTION
- TO TURN OFF GAS TO
APPLIANCE
Should overheating occur, or the gas supply fail to shut off, shut off the man­ual gas valve to the fur­nace before shutting off the electrical supply .
1. Set the thermostat to the lowest
setting.
2. Turn off all electrical power to the
appliance if service is to be per­formed.
3. Remove burner access panel by
removing screws and lifting panel out.
4. Turn the manual gas switch to
the “OFF” position.
Manual Gas Switch
Manual Gas Switch
5. Replace the control access panel.
WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in dangerous opera­tion, serious injury, death or property damage.
Improper servicing could result in dangerous opera­tion, serious injury, death or property damage.
• Before servicing, discon­nect all electrical power to furnace.
• When servicing controls, label all wires prior to dis­connecting. Reconnect wires correctly.
• Verify proper operation after servicing.
SECURE OWNER’S APPROVAL
When the system is functioning properly, secure the owner’s approval. Show the owner the loca­tion of all disconnect switches and the thermostat. Teach owner how to start and stop the unit and how to adjust temperature settings within the limitations of the system. Advise owner that the flue exhaust hood surface and the immediate
4 Unitary Products Group
291891-YUM-A-0207
area will experience high tempera­tures during the heating cycle. All unauthorized personnel and debris must be kept away from this area.
MAINTENANCE
NORMAL MAINTENANCE
WARNING
PRIOR TO ANY OF THE FOLLOWING MAINTE­NANCE PROCEDURES, SHUT OFF ALL POWER TO THE U NI T, TO AVOID PERSONAL INJURY.
Periodic maintenance consists of changing or cleaning filters. Under some conditions, the main burners should be cleaned.
LUBRICATION
The indoor blower motor, outdoor fan motor and venter motor are permanently lubricated and require no maintenance.
GENERAL MAINTENANCE
The manufacturer recommends that the furnace system be inspected once a year by a quali­fied service person.
For proper and safe operation, the gas heating section needs air for combustion and ventilation. Do not block or obstruct air openings on the unit, nor the spacing around the unit. Keep the gas heating s ystem area clear and free of combustible materials, gasoline and other flam­mable vapors and liquids.
Snow or debris should not be allowed to accumulate in or around the unit. Do not permit overhanging structures or shrubs to obstruct condenser air discharge or vent outlet on your unit. These provide air for combustion and ventilation.
FILTER CARE
Single phase units are shipped with­out a filter and is the responsibility of
the installer to secure a filter in the
return air ductwork or install a Fil­ter/Frame Kit (1FF0110, 1FF0112 or
1FF0114). A filter rack and a high velocity fil-
ters are standard on three phase units.
Filters must always be used and must be kept clean. When filters become dirt laden, insufficient air will be delivered by the blower, decreas­ing your units efficiency and increas­ing operating costs and wear-and­tear on the unit and controls.
OUTDOOR COIL
Dirt should not be allowed to accu­mulate on the outdoor coil surface or other parts in the air circuit. Cleaning should be as often as necessary to keep the coil clean. Use a brush, vacuum cleaner attachment, or other suitable means. If water is used to clean the coil, be sure that the power to the unit is shut off prior to cleaning.
Exercise care when clean­ing the coil so that the coil fins are not damaged.
Do not permit the hot con­denser air discharge to be obstructed by overhang­ing structures or shrubs.
BURNER
At the beginning of each heating season, make a visual check of the main burner flame. If it is not possi­ble to adjust for the proper flame, the burner may need cleaning.
TO CLEAN BURNERS
Remove them from the furnace as explained in Burner Instructions. Clean burners with hot water applied along top of the burner.
COMBUSTION AIR DISCHARGE
Visually inspect discharge outlet periodically to insure soot and dirt buildup is not excessive. If neces­sary, clean to maintain adequate combustion air discharge.
The manufacturer recommends that the furnace system be inspected once a year by a quali­fied serviceperson.
CLEANING FLUE PASSAGES AND HEATING ELEMENTS
With proper combustion adjust­ment the heating element of a gas fired furnace will seldom need cleaning. If the element should become sooted, it can be cleaned as follows:
1. Remove the burner assembly as outlined in BURNER INSTRUC­TIONS.
2. Remove the screws securing the restrictor plate to the tube sheet.
3. Using a wire brush on a flexible wand, brush out the inside of each heat exchanger from the burner inlet and flue outlet ends.
4. Brush out the inside of the restrictor plate to the tube sheet.
5. If soot build-up is particularly bad, remove the vent motor and clean the wheel and housing.
6. After brushing is complete, blow all brushed areas with air or nitrogen. Vacuum as needed.
7. Replace parts in the order they were removed in steps 1 through
3.
REGISTERS
Supply air and return air registers must be open when the unit is in operation. Furniture must not block airflow in or out of the registers.
Unitary Products Group 5
291891-YUM-A-0207
TABLE 1: GAS RATE - CUBIC
FEET PER HOUR
SECONDS
FOR ONE
REV. 1/2 CU. FT. 1 CU. FT.
10 180 360 12 150 300 14 129 257 16 113 225 18 100 200 20 80 180 22 82 164 24 75 150 26 69 138 28 64 129 30 60 120 32 56 113 34 53 106 36 50 100 38 47 95 40 45 90 42 43 86 44 41 82 46 39 78 48 37 75 50 36 72 52 35 69 54 34 67 56 32 64 58 31 62 60 30 60
1.
EXAMPLE: By actual measurement, it takes 38 seconds for the hand on the 1­cubic foot dial to make a revolution with just a 100,000 BTUH furnace running. Using this information, locate 28 sec­onds in the first column of the table. Read across to the column headed “1 Cubic Foot,” where you will see that 95 cubic feet of gas per hour are consumed by the furnace at that rate. Multiply 95 x 1050 (the BTU rating of the gas obtained from the local gas company). The result is 99,750 BTUH which is close to the 100,000 BTUH rating of the furnace.
SIZE OF TEST DIAL
1
TROUBLESHOOTING
BEFORE CALLING A SERVICE­PERSON:
A. Check thermostat setting and
insure thermostat is calling for heat or cooling.
B. Check thermostat for lint, dust,
etc.
C. Check fuses or circuit break-
ers.
D. Check filters for excessive dust
accumulation and/or restric­tion.
REPLACEMENT PARTS
Contact your local York parts distri­bution center for authorized replace­ment parts.
SOME EFFICIENCY DO'S AND DON'TS
DON'T heat or cool unused areas. Reduce supply and return air flow to a minimum in areas which are not living spaces (storage rooms, garaged, basements, etc.).
DON'T be a “thermostat jiggler”. Moving your thermostat setting will not make your system heat or cool any faster. Adjust your thermostat to a comfortable setting and leave it there.
DON'T restrict air circulation. Plac­ing furniture, rugs, etc. in such a way that they interfere with air vents will make your system work harder to achieve a comfortable temperature level. This requires more energy, which means greater cost to you.
DON'T heat or cool when you are away. If you are going to be away for a day or more, re-adjust your thermostat accordingly. Your furni­ture is far less demanding than you are when it comes to comfort lev­els. However, don't expect the sys­tem to restore comfort conditions immediately upon returning home. It will take a little time.
DON'T locate lamps or other heat­producing appliances (radios, TV's, heaters, etc.) near your thermostat. The heat from these items will give your thermostat “false information” about the temperature in the room.
DO select a comfortable thermostat setting, but keep in mind that mod­eration in temperature selection will save energy.
DO turn on your kitchen exhaust fan when cooking and your bath­room exhaust fan when showering. Also, make sure your clothes dryer is properly vented. If these items are neglected, an excess heat and humidity condition may be created, causing your air conditioning sys­tem to run longer.
DO set your thermostat a few degrees lower than normal several hours before entertaining a large group of people in a relatively small area. People give off a consider­able amount of heat and moisture in a closed area.
DO keep drapes and Venetian blinds closed when practical. These items provide insulation against heat loss/gain.
DO contact a qualified serviceper­son to make repairs or adjustments to your system. They have been trained to perform this service.
6 Unitary Products Group
291891-YUM-A-0207
Unitary Products Group 7
ISO 9001
Certified Quality
Management System
Subject to change without notice. Printed in U.S.A. 291891-YUM-A-0207 Copyright © by Unitary Products Group 2007. All rights reserved. Supersedes: Nothing