Yokogawa MY600 Specifications

MY600
Digital Insulation Tester
Improve your inspection and regular maintenance efciency with MY600!
MY600 Digital Insulation Tester has enhanced operation compared to the conventional model by using a shortened measurement time and color indicating judging function. This is a new concept in insulation testers with a communication function to enhance the afnity with a PC or tablet.
Major Features
Two colors for judging measurement results
Set a desired reference value with the comparator function, and it will judge PASS (Green) or FAIL (Red) of a measurement result.
Measurement
PASS FAIL
Judge
Approximately 0.5 s high-speed measurement*
Measurement time of insulation resistance is approx. 0.5 s, which contributes to reducing the operation time.
* Under the conditions specied by Yokogawa, it may take time to measure due
to the inuence of capacitive component of a measuring target.
MY40
MY600
approx. 0.5 s
Time comparison of measured value display
Reduced to approx. 1/6.
approx. 3 s
USB communication and memory function
PC communication is possible with the dedicated USB communication adaptor (91030). Users can save as many as 1000 measurements to the internal memory from which data required for report generation, such as measurement data/time, measured value and range can be transmitted to a PC via communication.
USB Communication adaptor
MY600
Image gure
Magnetic ow meter
Insulation deterioration diagnosis (PI and DAR measurement*)
The increase and decrease of resistance value can be measured by continuously measuring the insulation resistance for a prescribed time. The insulation deterioration of the unit under test can be diagnosed by this increase/ decrease. This parameter is useful for preventive maintenance of industrial automation equipment such as Magnetic Flow Meters or electrical equipment.
*PI: Polarization Index (Resistance after 1 minute/Resistance after 10 minutes) DAR: Dielectric Absorption Rate (Resistance after 15 seconds/Resistance after
1 minute)
Auto lighting backlight and LED light
MY600 has a backlight that automatically lights up in a dark place, as well as an LED light to illuminate objects.
Line probe with switch is provided as a standard accessory
Users can turn measurement on/ off with the hand switch on the line probe, allowing them work more efciently.
Bulletin MY600-01EN
Main Specications Accuracy (tolerance): Within 1 year of shipment
NOTICE
Rated measuring voltage 50 V 100 V* 125 V* 250 V 500 V 1000 V
Maximum effective reading 100 MΩ 200 MΩ 250 MΩ 500 MΩ 2000 MΩ 4000 MΩ
First effective measurement range 0.100 to 10.00 MΩ 0.100 to 20.00 MΩ 0.100 to 25.00 MΩ 0.100 to 50.0 MΩ 0.100 to 500 MΩ 0.100 to 1000 MΩ
Accuracy ±2% reading ±2 digit
Second effective measurement range 10.01 to 100.0 MΩ 20.01 to 200.0 MΩ 25.01 to 250.0 MΩ 50.1 to 500 MΩ 501 to 2000 MΩ 1001 to 4000 MΩ
Accuracy ±5% reading
0.050 to 0.099 MΩ: ±2% reading ±4 digit
Other ranges accuracy 0.000 to 0.049 MΩ: ±2% reading ±6 digit
*Switching method
Major functions Accuracy (tolerance): Within 1 year of shipment
Voltage Measurement
Low resistance Measurement
Display Bar graph, 4000 digital count display
Functions Automatic discharge, Live-line alarm, Pass/Fail
Measurement categories CAT III 600 V
Protection grade IP40
Standard JIS C 1302: 2018 compliant (Planned)
AC 2.0 to 600 Vrms (45 to 65 Hz)
DC ±(2.0 to 600) V
Accuracy ±1% reading ±4 digit
AC/DC auto detection (2 V or more)
Range 40.00/400.0/4000 Ω (Auto range)
Accuracy
±2.5% reading ±8 digit (0.20 to 4000 Ω) ±8 digit (0.00 to 0.19 Ω)
judgement by comparator, Buzzer warning, USB communication, Battery check, Measured values
strage, Elapsed time display, PI/DAR display, Serial No. display, Data hold, Auto LED light
EN61557-1, 2, 4, 10 EN61326-1 ClassB, EN61326-2-2 EN61010-1, EN61010-031, EN61010-2-30, IEC61010-2-034
General Specications
Test condition 23±5°C, 80% RH or less (no condensation)
Operating temperature/ humidity range
Storage temperature/ humidity range
Auto-power off The tester is automatically turned off when no key
Battery Life Approx. 1300 tries (500 V/0.5 MΩ)
Power source Four size AA batteries
Dimensions Approx. 156 (W) × 46 (H) × 97 (D) mm
Weight Approx. 490 g (with battery)
Standard accessories (attached)
Accessories (sold separately)
This is a Class B instrument based on Emission standards EN61326-1 and EN55011, and is designed for an industrial environment. Operation of this equipment in a residential area may cause radio interference, in which case users will be responsible for any interference which they cause.
−10 to +50°C, 80% RH or less (no condensation)
−20 to +60°C, 75% RH or less (no condensation)
operations are performed for 10 minutes.
Instruction manual, Four size AA batteries, 93045: Soft case, 98008: Line probe, 98009: Earth probe set, 99018: Shoulder strap
91030: USB Communication Adaptor, 99012: Probe tip (extended type), 99013: Probe tip (hook type)
91030 USB Communication Adaptor Specication
Communication cable
Cable length 1.9 m
Interface USB ver. 1.1
Supported model MY600
Included accessories (attached)
Model code and sufx
Model code Notes
MY600 Digital Insulation Tester
Accessories
Model code Model name Notes Attached
91030
93045 Soft case
98008
98009
99012
99013
99018 Shoulder strap
Due to the nature of this product, it is possible to touch its metal parts. Therefore, there
USB communication adaptor
Line probe with remote switch
Earth probe set
Probe tip (hook type)
Probe tip (extended type)
is a risk of electric shock, so the product must be used with caution.
Outline drawing
Before operating the product, read the user’s manual thoroughly for proper and safe operation.
Infrared communication adaptor and Communications cable (USB) 1 set
CD Packing contents: Communication driver, User’s manual, Install manual
USB communication dedicated cable between PC and the main unit
Main baby and accessory­housing
Length: 1.4 m, MY600 only Yes
Length: 2.0 m, Earth probe and alligator clip adapters
Size: 61.9 × 26 mm No
Length: 115.4 mm No
For hanging the main body during measurement
156
97
46
No
Yes
Yes
Yes
Unit: mm
http://tmi.yokogawa.com/
YOKOGAWA TEST & MEASUREMENT CORPORATION
Global Sales Dept. /Phone: +81-422-52-6237 E-mail: tm@cs.jp.yokogawa.com
Copyright © 2018, Yokogawa Test & Measurement Corporation
Subject to Change without notice.
Facsimile: +81-422-52-6462
YOKOGAWA CORPORATION OF AMERICA E-mail: tmi@us.yokogawa.com YOKOGAWA EUROPE B.V. Phone: +31-88-4641000 E-mail: tmi@nl.yokogawa.com YOKOGAWA SHANGHAI TRADING CO., LTD. Phone: +86-21-6239-6363 E-mail: tech@ysh.com.cn Facsimile: +86-21-6880-4987 YOKOGAWA ELECTRIC KOREA CO., LTD. Phone: +82-2-2628-3810 E-mail: TMI@kr.yokogawa.com Facsimile: +82-2-2628-3899 YOKOGAWA ENGINEERING ASIA PTE. LTD. Phone: +65-6241-9933 E-mail: TMI@sg.yokogawa.com Facsimile: +65-6241-9919 YOKOGAWA INDIA LTD. Phone: +91-80-4158-6396 E-mail: tmi@in.yokogawa.com Facsimile: +91-80-2852-1442 YOKOGAWA ELECTRIC CIS LTD. Phone: +7-495-737-78-68 E-mail: info@ru.yokogawa.com Facsimile: +7-495-737-78-69 YOKOGAWA AMERICA DO SUL LTDA. Phone: +55-11-5681-2400 YOKOGAWA MIDDLE EAST & AFRICA B.S.C(c) Phone: +973-17-358100 E-mail: help.ymatmi@bh.yokogawa.com Facsimile: +973-17-336100
YMI-KS-MI-SE05
Printed in Japan, 807(KP)
[Ed: 01/b]