Handling Precautions of the FX .................................................................................................................................4
Checking the Contents of the Package .....................................................................................................................5
Protection of Environment .........................................................................................................................................7
Conventions Used in This Manual .............................................................................................................................7
Introduction to Functions .............................................................................................................................................8
Data Storage Function ...............................................................................................................................................8
Display Function ........................................................................................................................................................8
Other Functions .........................................................................................................................................................8
DAQSTANDARD for FX1000 .....................................................................................................................................8
FX System Conguration ...........................................................................................................................................9
Names of Parts ............................................................................................................................................................10
Display on the Status Display Section .....................................................................................................................13
Run Modes ..............................................................................................................................................................14
Entering Values and Characters ..............................................................................................................................15
Inserting/Removing a CF Card/SD Card .................................................................................................................16
Setting the Functions and Operations ......................................................................................................................18
Setting the Date/Time ..............................................................................................................................................18
Setting the Input Range ...........................................................................................................................................19
Setting the Temperature Measurement Channel, the Input Range, and the Tag ...............................................19
Setting the Flow Rate Measurement Channel, the Input Range, the Alarm, and Tag .............................................22
Assigning Channels to Groups ................................................................................................................................23
Setting the Time Scale .............................................................................................................................................24
Saving the Setup Data .............................................................................................................................................25
Switching the Trend Display, Digital Display, and Bar Graph Display ......................................................................27
Writing the Message “START” .................................................................................................................................28
Monitoring the FX on a PC Browser (Ethernet) (/C7 Option) ...................................................................................30
Displaying the Measured Data on DAQSTANDARD .................................................................................................33
Chapter 1 Overview of Functions
Chapter 2 Common Operations
Chapter 3 Measurement Channels and Alarms
Chapter 4 Switching Operation Screens
Chapter 5 Operations for Changing the Displayed Contents
Chapter 6 Saving and Loading Data
Chapter 7 Customizing the Action Using the Event Action and Remote Control Functions (/R1 and /PM1 Options)
Chapter 8 Using the Security Function
Chapter 9 Computation and Report Functions (/M1, /PM1, /PWR1, and /PWR5 Options)
Chapter 10 Troubleshooting
Chapter 11 Calibration
Chapter 12 Installing and Wiring
Chapter 13 Specications
Chapter 14 Setup Items
FX1000 Communication Interface User’s Manual (Electronic Manual: IM04L21B01-17EN)
Chapter 1 Using the Ethernet Interface (/C7 Option)
Chapter 2 Using the Serial Interface (/C2 and /C3 Options)
Chapter 3 Commands
Chapter 4 Responses
Chapter 5 Status Reports
Chapter 6 Specications
2
IM 04L21B01-02EN
“Handle with care.” To avoid injury and damage to
Direct current
Introduction
Thank you for purchasing the FX1002, FX1004, FX1006, FX1008,
FX1010, or FX1012 Paperless Recorder (hereafter referred to
as “FX” or “FX1000”).This manual describes the basic operating
procedures of the FX. To ensure correct use, please read this
manual and the manuals below thoroughly before beginning
operation.
Paper Manual
Manual TitleManual No.
Model FX1002/FX1004/FX1006/FX1008/
FX1010/FX1012
FX1000 Paperless Recorder Safety
Precautions and Installation Guide
Installing the FXA120 DAQSTANDARD
FX1000 Mode Transition Diagram
Setting Mode / Basic Setting Mode Maps
Electronic Manuals
You can download these manuals from the following web page. You
will need Adobe Reader 7 or later (latest version recommended) by
Adobe Systems.
FX1000 Paperless Recorder
Communication Interface
(/C2, /C3, and /C7)
FXA120 DAQSTANDARD for FX1000
Data Viewer
FXA120 DAQSTANDARD for FX1000
Hardware Configurator
IM 04L21B01-03EN
IM 04L21B01-01EN
IM 04L21B01-02EN
IM 04L21B01-03EN
IM 04L21B01-17EN
IM 04L21B01-63EN
IM 04L21B01-64EN
*
*
Notes
• The contents of this manual are subject to change without prior
notice as a result of continuing improvements to the instrument’s
performance and functions.
• Every effort has been made in the preparation of this manual to
ensure the accuracy of its contents. However, should you have
any questions or find any errors, please contact your nearest
YOKOGAWA dealer.
• Copying or reproducing all or any part of the contents of this
manual without YOKOGAWA’s permission is strictly prohibited.
• The TCP/IP software of this product and the document
concerning the TCP/IP software have been developed/created
by YOKOGAWA based on the BSD Networking Software,
Release 1 that has been licensed from the Regents of the
University of California.
QR Code
The product has a QR Code pasted for efficient plant maintenance
work and asset information management.
It enables confirming the specifications of purchased products and
user’s manuals.
For more details, please refer to the following URL.
Microsoft and Windows are registered trademarks or trademarks of
Microsoft Corporation in the United States and/or other countries.
• Adobe and Acrobat are registered trademarks or trademarks of
Adobe Systems Incorporated.
• Company and product names that appear in this manual are
registered trademarks or trademarks of their respective holders.
• The company and product names used in this manual are not accompanied
by the registered trademark or trademark symbols (® and ™).
Safety Precautions
• This instrument conforms to IEC safety class I (provided with terminal
for protective grounding), Overvoltage Category II or I
Degree 2, and Measurement Category II (CAT II)
*1 II: Applied to standard power supply(100-240 VAC), I: Applied
to /P1 option (24 VDC/AC)
*2 Measurement Category II (CAT II) applies to measuring
circuits connected to low voltage installation, and electrical
instruments supplied with power from fixed equipment such
as electric switchboards.
• This instrument is an EN61326-1 (EMC standard) class A
instrument (for use in commercial, industrial, or business
environments). The influence rate (judgment condition A) in the
immunity test environment is within ±15 % of the range or ±10 mV.
• The general safety precautions described here must be
observed during all phases of operation. If the FX is used in a
manner not described in this manual, the FX safety features may
be impaired. Yokogawa Electric Corporation assumes no liability
for the customer’s failure to comply with these requirements.
• The FX is designed for indoor use.
• About User’s Manuals
• Please pass user’s manuals to the end user. We also ask you to
store user’s manuals in a safe place.
• Read user’s manuals thoroughly and have a clear understanding
of the product before operation.
• User’s manuals explains the functions of the product. They do not
guarantee that the product will suit a particular purpose of the user.
• Precautions Related to the Protection, Safety, and Alteration of
the Product
The following safety symbols are used on the product and in this
manual.
the instrument, the operator must refer to the
explanation in the manual.
Protective ground terminal
Alternating current
• For the protection and safe use of the product and the system in
3
which this product is incorporated, be sure to follow the instructions
and precautions on safety that are stated in this manual whenever
you handle the product. Take special note that if you handle the
product in a manner that violates these instructions, the protection
functionality of the product may be damaged or impaired. In such
cases, YOKOGAWA does not guarantee the quality, performance,
function, and safety of product.
• When installing protection and/or safety circuits such as lightning
protection devices and equipment for the product and control
system or designing or installing separate protection and/or
safety circuits for fool-proof design and fail-safe design of the
processes and lines that use the product and the control system,
the user should implement these using additional devices and
equipment.
• If you are replacing parts or consumable items of the product,
make sure to use parts specified by YOKOGAWA.
• This product is not designed or manufactured to be used in
critical applications that directly affect or threaten human lives.
Such applications include nuclear power equipment, devices
using radioactivity, railway facilities, aviation equipment, air
navigation facilities, aviation facilities, and medical equipment.
If so used, it is the user’s responsibility to include in the system
additional equipment and devices that ensure personnel safety.
• Do not modify this product.
WARNING
• Use the Correct Power Supply
Ensure that the source voltage matches the voltage of the power
supply before turning ON the power.
• Connect the Protective Grounding Terminal
Make sure to connect the protective grounding to prevent
electric shock before turning ON the power.
• Do Not Impair the Protective Grounding
Never cut off the internal or external protective grounding wire or
disconnect the wiring of the protective grounding terminal. Doing
so invalidates the protective functions of the instrument and
poses a potential shock hazard.
• Do Not Operate with Defective Protective Grounding
Do not operate the instrument if the protective grounding might
be defective. Also, make sure to check them before operation.
• Do Not Operate in an Explosive Atmosphere
Do not operate the instrument in the presence of flammable liquids or
vapors. Operation in such an environment constitutes a safety hazard.
Prolonged use in a highly dense corrosive gas (H2S, SOx, etc.)
will cause a malfunction.
• Do Not Remove Covers
The cover should be removed by YOKOGAWA’s qualified
personnel only. Opening the cover is dangerous, because some
areas inside the instrument have high voltages.
• Ground the Instrument before Making External Connections
Connect the protective grounding before connecting to the item
under measurement or control unit.
• Damage to the Protection
Operating the instrument in a manner not described in this
manual may damage the instrument’s protection.
CAUTION
This instrument is a Class A product. Operation of this instrument
in a residential area may cause radio interference, in which case
the user is required to take appropriate measures to correct the
interference.
CAUTION
• Normal Operating Conditions
Ambient temperature: 0 to 50°C
Ambient humidity: 20 to 80%RH (However, less than moisture content of
°C
80% RH at 40°C or more), No condensation
40
Warm-up time: At least 30 minutes after power on
Installation location: Indoors
Operating altitude: 2000 m or less
Overvoltage Category: II or I
TEMPORARY OVERVOLTAGES: It may occur on the MAINS supply;
Short-term temporary overvoltage: 1460V
Long-term temporary overvoltage: 490V
Pollution degree: 2
WARNING
• Precaution on Relay Wiring
Since the insulation provided to each relay output terminal is Functional
insulation, provide Reinforced insulation to the external of the device as
necessary. (Refer to the drawing below.)
This product
Functional
insulation
voltage circuit
voltage circuit
A safety
A safety
This product
Functional
insulation
This product
Functional
insulation
A safety
voltage circuit
Reinforced insulation
A hazardous
voltage circuit
Reinforced insulation
A hazardous
voltage circuit
Reinforced insulation
A hazardous
voltage circuit
Reinforced insulation
A safety
voltage circuit
A hazardous
voltage circuit
A hazardous
voltage circuit
A hazardous
voltage circuit
• Exemption from Responsibility
• YOKOGAWA makes no warranties regarding the product except
those stated in the WARRANTY that is provided separately.
• YOKOGAWA assumes no liability to any party for any loss
or damage, direct or indirect, caused by the user or any
unpredictable defect of the product.
• Handling Precautions of the Software
• YOKOGAWA makes no warranties regarding the software
accompanying this product except those stated in the
WARRANTY that is provided separately.
• Use the software on a single PC.
• You must purchase another copy of the software, if you are to
use the software on another PC.
• Copying the software for any purposes other than backup is
strictly prohibited.
• Please store the original media containing the software in a safe
place.
• Reverse engineering, such as decompiling of the software, is
strictly prohibited.
• No portion of the software supplied by YOKOGAWA may be
transferred, exchanged, or sublet or leased for use by any third
party without prior permission by YOKOGAWA.
Handling Precautions of the FX
• Use care when cleaning this instrument, especially its plastic
parts. Use a soft dry cloth. Do not use organic solvents, such
as benzene or thinner, or other cleansers. They may cause
discoloring and deformation.
• Keep electrically charged objects away from the signal terminals.
If you do, the FX may malfunction.
• Do not apply volatile chemicals to the display, panel keys, etc.
Do not allow rubber and vinyl products to remain in contact
with the FX for long periods of time. If you do, the FX may
4
IM 04L21B01-02EN
malfunction.
name plate
• When not in use, make sure to turn OFF the power switch.
• If there are any symptoms of trouble such as strange odors or
smoke coming from the FX, immediately turn OFF the power
switch and the power supply source. Then, contact your nearest
YOKOGAWA dealer.
CF Card Handling Precautions
• Use caution in the handling of the external storage medium as it
is a delicate product.
• Write operation to storage media may fail under hightemperature or low-temperature environments. If you are using
the FX in a low-temperature environment (around 10 °C or
less), use the FX after the warm-up time (at least 30 minutes)
has elapsed. If you are using the FX under a high-temperature
environment (around 40 °C or more), it is recommended that the
external storage medium be inserted into the drive when saving
the data and be removed after the data storage operation is
finished.
• Remove the storage medium from the drive when turning the FX
ON/OFF.
• Touching the compact flash section when static electricity is built
up on the human body can lead to erroneous operation.
• For the general handling precautions of the external storage
medium, see the instruction manual that came with the external
storage medium.
• Yokogawa provides no warranty for damage to, or loss of data
recorded on the SD card, regardless of the cause of such
damage or loss. Please always make backup copies of your
data.
• Do not store or use the SD card in places with static electricity,
near electrically charged objects, or where electrical noise is
present. Doing so can result in shock or damage.
• Do not disassemble or modify the SD card. Doing so can result
in damage.
• Only use Yokogawa SD cards. Operation cannot be guaranteed
with other brands of card.
• Never touch the SD card with wet hands. Doing so can lead to
shock or malfunction.
• Never use the SD card if it is dusty or dirty. Doing so can lead to
shock or malfunction.
SD Card Handling Precautions
• SD cards are delicate and should be handled with caution.
• Yokogawa provides no warranty for damage to, or loss of data
recorded on the SD card, regardless of the cause of such
damage or loss. Please always make backup copies of your
data.
• Do not store or use the SD card in places with static electricity,
near electrically charged objects, or where electrical noise is
present. Doing so can result in shock or damage.
• Do not disassemble or modify the SD card. Doing so can result
in damage.
• Do not physically shock, bend, or pinch the SD card. Doing so
can lead to malfunction.
• During reading/writing of data, do not turn OFF the power,
apply vibration or shock, or pull out the card. Data can become
corrupt or permanently lost.
• Only use Yokogawa SD cards. Operation cannot be guaranteed
with other brands of card.
• When inserting the SD card into the instrument, make sure you
orient the card correctly (face up or down) and that you insert it
securely. If not inserted correctly, the card will not be recognized
by the instrument.
• Never touch the SD card with wet hands. Doing so can lead to
shock or malfunction.
• Never use the SD card if it is dusty or dirty. Doing so can lead to
shock or malfunction.
• The SD card comes formatted.
SD cards must be formatted according to the standard
established by the SD Association (https://www.sdcard.org/
home). Use the SD card formatter software available from the
above SD Association to format SD cards on a PC. You cannot
format SD cards on the FX.
• You can use SD/SDHC cards (up to 32 GB) on the FX.
• The write protected SD card cannot be used on this product.
• SD-Card is intended for transfer of data between FX1000 and a
target system (and not for transferring data between third party
systems)
SD Card Specications
Electrical specificationsOperating voltage: 2.7 V to 3.6 V
(memory operation)
–25 to 85°C/20 to 85%RH
(no condensation)
–40 to 85°C/5 to 85%RH
(no condensation)
Unit: mm
24±0.1
Writable
WP
SD
32±0.1
Write-protected
CAUTION
• Do not access the storage medium in a place with vibrations or
shock. The storage medium or drive may malfunction.
Checking the Contents of the Package
Unpack the box and check the contents before operating the
instrument. If some of the contents are not correct or missing or
if there is physical damage, contact the dealer from which you
purchased them.
FX
A name plate is located on the top panel of the FX. Check that the
model name and suffix code given on the name plate match those
on your order.
NO. (Instrument Number)
When contacting the dealer from which you purchased the
instrument, please give them the instrument number.
IM 04L21B01-02EN
5
Model and Sux Codes
Model
code
FX1002
FX1004
FX10066ch, Shortest measurement interval:1s
FX10088ch, Shortest measurement interval:1s
FX1010
FX1012
External
storage
medium
slot
Language-2
Withstanding
voltage between
measuring input
terminals
Options/A1Alarm output 2 points (C-contact)
Suffix code
-0Without CF card slot/SD card slot and
-4With CF card slot and medium
-7With SD card slot and medium
Optional
code
-H1000 VAC(50/60 Hz), 1 min
-L400 VAC(50/60 Hz), 1 min
/A2Alarm output 4 points (C-contact)
/A3Alarm output 6 points (C-contact)
/A4AAlarm output 12 points (A-contact)
/C2RS-232 interface
/C3RS-422A/485 interface
/C7Ethernet interface
/F1FAIL/Status output
/M1
/N23 leg isolated RTD
/N3FExtended input type (without Pt1000)
/P124 VDC/AC power supply
/R1Remote control 8 points
/TPS224VDC transmitter power supply (2
/TPS424VDC transmitter power suply (4
/USB1USB interface (1 port)
/PM1Pulse input 3 points, Remote control
/CC1Calibration correction function
/LG1Log scale
/PWR1Power monitor (1 A input, including
/PWR5Power monitor (5 A input, including
/S#Customized product; details in IM
Description
2ch, Shortest measurement interval:125ms
4ch, Shortest measurement interval:125ms
10ch, Shortest measurement interval:1s
12ch, Shortest measurement interval:1s
(Note)
medium
English/German/French/Italian/ Spanish/
Portuguese/ Russian/ Korean
deg F and DST
Note: To load data, the FX must be equipped with a communication
interface (/C2, /C3 or /C7 option) or the USB interface (/USB1 option.)
*1 Any combination of /A1, /A2, /A3, and /A4A cannot be specified
together.
*2 /C2 and /C3 cannot be specified together.
*3 /A3 or /A4A cannot be specified together with /F1.
*4 /N2 cannot be specified for FX1002 or FX1004.
*5 If /R1 is specified, /A4A, /TPS2, /TPS4, /PM1, /PWR1, or /PWR5
cannot be specified.
*6 If /TPS2 is specified, /TPS4, /A2, /A3, /A4A, /F1, /R1, or /PM1
cannot be specified.
*7 If /TPS4 is specified, /TPS2, /A1, /A2, /A3, /A4A, /F1, /R1, or /
PM1 cannot be specified.
*8 If /PM1 is specified, /A4A, /M1, /R1, /TPS2, /TPS4, /PWR1, or /
PWR5 cannot be specified.
*9 If /PWR1 is specified, /A3, /A4A, /F1, /R1, /PM1, /M1, or /PWR5
cannot be specified.
*10 /TPS2, /PWR1, and /A1 cannot be specified together. /TPS2, /
PWR5, and /A1 cannot be specified together.
*11 If /PWR5 is specified, /A3, /A4A, /F1, /R1, /PM1, /M1, or /PWR1
cannot be specified.
*12 Contact your supplier in case your instrument has option /S#
(where ‘#’ is a number), and you are not in the possession of IM
FX1K-S#E.
Standard Accessories
The standard accessories below are supplied with the instrument.
Check that all contents are present and undamaged.
12
3
No. NameModelQty. Notes
1Mounting bracketsB8730BU2For panel
2Rubber packing
for dust and water
protection
3Model FX1002/
FX1004/FX1006/
FX1008/FX1010/
FX1012
FX1000 Paperless
Recorder Safety
Precautions and
Installation Guide
*1 On FXs that have a CF card slot (suffix code -4.)
CF card capacity is subject to change.
*2 On FXs that have a SD card slot (suffix code -7.)
SD card capacity is subject to change.
*1
*2
4
-1For single-unit
IM 04L21B01-03EN
7720931512 MB
77300111 GB
5
mounting
mounting
1A3 size
Softoware (FXA120 DAQSTANDARD for FX1000), Label
Please download the software and the label data from the following
web page.
http://www.yokogawa.com/ns/fx1000/soft/
ItemDescription
SoftwareFXA120 DAQSTANDARD for FX1000
LabelLabels to Attach to the FX1000 Operation Cover
Consists of the Data Viewer and the Hardware Configurator.
Download the label data (Excel file). Print the label that you
want to use.
Label size: 19 ± 0.3 mm tall and 90 ± 0.3 mm wide
File name: IM04L21B01-81Z1.xls
6
IM 04L21B01-02EN
Release number
Optional Accessories (Sold Separately)
The following optional accessories are available for purchase
separately. If you make an order, make sure that all contents
are present and undamaged. For information about ordering
accessories, contact the dealer from which you purchased the FX.
No. NameModelQ’ty Notes
1CF card7720931512 MB
2Shunt resistor
3Mounting
brackets
4Terminal screws B8730CZ–M3 (spares for I/O
5SD card773001–1 GB
Style number, release number, and firmware
77209411 GB
77209512 GB
X010-250-3
X010-100-3
X010-010-3
B8730BU2–
B8730CY–M4 (spares for power
1250 Ω ± 0.1%
1100 Ω ± 0.1%
110 Ω ± 0.1%
terminals)
terminals)
version number of the FX
Style number: This is the FX hardware number that is indicated
on the name plate.
Release number: This is the FX firmware number that is indicated
on the name plate. The number corresponds to
the integer part of the firmware version number.
Example: If the firmware version number is 2.01, the release
number is 2.
Firmware version number: This number is displayed on the FX
system information screen. For the procedure,
see section 2.5, “Viewing the FX Information” in
the FX1000 User’s Manual, IM 04L21B01-01EN.
Style number
Conventions Used in This Manual
• This manual covers information regarding FX1000 that have a
suffix code for language “-2” (English).
• For details on how to set the language, see section 2.6,
“Changing the Displayed Language” in the FX1000 User’s Manual, IM 04L21B01-01EN.
Unit
K: Denotes 1024. Example: 768 KB (file size)
k: Denotes 1000.
The following markings are used in this manual.
Improper handling or use can lead to injury to the user or damage
to the instrument. This symbol appears on the instrument to
indicate that the user must refer to the user’s manual for special
instructions. The same symbol appears in the corresponding place
in the user’s manual to identify those instructions. In the manual,
the symbol is used in conjunction with the word “WARNING” or
“CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious or
fatal injury to the user, and precautions that can be taken to prevent
such occurrences.
CAUTION
Calls attentions to actions or conditions that could cause light
injury to the user or damage to the instrument or user’s data, and
precautions that can be taken to prevent such occurrences.
Note
Calls attention to information that is important for proper operation
of the instrument.
Indicates after this mark reference to related procedure or
explanation.
Bold characters
Indicates character strings that appear on the screen and the
operation keys.
Protection of Environment
Control of Pollution Caused by the Product
For details, see the FX1000 Safety Precautions and Installation
Guide, IM04L21B01-03EN.
How to Dispose the Batteries
This is an explanation about the new EU Battery Directive
(DIRECTIVE 2006/66/EC). This directive is only valid in the EU.
Batteries are included in this product. Batteries incorporated into
this product cannot be removed by yourself. Dispose them together
with this product. When you dispose this product in the EU, contact
your local Yokogawa Europe B.V.office. Do not dispose them as
domestic household waste.
Battery type: Lithium battery
Notice: The symbol (see above) means they shall be sorted out
and collected as ordained in ANNEX II in DIRECTIVE 2006/66/EC.
IM 04L21B01-02EN
7
Introduction to Functions
Trend display
Numeric (digital) display
Overview display Bar graph display
Measured Items
You can connect DC voltage, thermocouple, RTD, and ON/OFF input and measure
various values such as temperature and flow rate. The FX samples the input signals at
the scan interval to obtain the measured values. The fastest scan interval is 125 ms on
the FX1002 and FX1004, and 125 ms on the FX1006, FX1008, FX1010, and FX1012.
Up to four alarm conditions can be set for each measurement channel.
Data Storage Function
There are two methods of recording measured data. One is to record the measured data
continuously, and the other is to record only when certain events occur such as alarms.
The measured data is recorded to the internal memory at a specified interval. The data in
the internal memory can be stored to a CF card/SD card
FX
*1
automatically or manually.
Display Function
Other Functions
Internal memory
Measurement input
*1 On FXs that have a CF card slot or an SD card slot
CF card/SD card
*1
Measured data can be displayed as trends, numeric values, and bar graphs for each
group. In addition, the overview display can be used to display and monitor all channels
on a single screen.
Mathematical Function
(/M1, /PM1, /PWR1, and /PWR5
options)
FAIL/status output function
(/F1 option)
Remote control function
(/R1 option)
Security functionEnables only registered users can operate the
Communication function
(/C2, /C3, and /C7 options)
Various types of computation can be performed by
assigning equations to computation channels (Math
channels.)
Outputs an alarm when the FX fails. The function
also monitors the FX status such as the remaining
amount of internal memory and outputs alarms.
A specified action is executed when a remote input
signal is applied to the terminal on the rear panel.
FX. The function can also be used to prohibit key
operation.
The Ethernet interface can be used to monitor the FX
using a Web browser and transmit e-mail when an
event occurs such as an alarm. In addition, data of
devices on the network can be loaded and displayed
using the Modbus protocol.
8
DAQSTANDARD for FX1000
The accompanying software program, DAQSTANDARD for FX1000, can be used to
display the measured data, convert the measured data format, and create FX setup data.
IM 04L21B01-02EN
FX System Configuration
Transmitter power supply
**: On FXs that have a CF card slot or an SD card slot
The FX can be used to configure a system as shown below.
Referenced sections are of the FX1000 User’s Manual (IM 04L21B01-01EN.)
Introduction to Functions
Communication Interface User’s Manual
(IM 04L21B01-17EN)
Ethernet
controller
Signal input
Sec. 3.3
Pulse input
Sec. 3.10
AC voltage and current
Sec. 3.12
Logarithmic DC voltage
Sec. 3.13
Alarm output
Sec. 3.5 to 3.8
FAIL/status output
*
*
*
*
*
*
Sec. 2.9
PC
RecorderTemperature
Serial
communication*
RS-232, RS-422A/485
CF card/SD card
FX
USB port*
Keys
Remote input
Sec. 7.1
PC
PLC
**
USB flash memory
Sec. 2.11
Keyboard
Sec. 2.10
*
Terminology
IM 04L21B01-02EN
*: Option
• Memory sample
The operation of recording measured data.
• Memory start
The operation of starting memory sampling.
• Memory stop
The operation of stopping memory sampling.
• Display data
The waveform data shown on the FX display. The data recorded at the sampling
interval for the displayed data.
• Event data
Measured data recorded at a sampling interval separate from that of the display data.
• Manual sample
The operation of recording measured data (instantaneous value) manually.