Yaesu RF UTUNING KIT INSTALLATION MANUAL

RF μTUNING KIT INSTALLATION MANUAL
EAE97X710
Congratulations on your purchase of the RF μTUNING KIT. Before installing the kit, please read this manual carefully. After installation, please keep this manual in a safe place for future reference.
NOTICE
Do not modify or adapt the μ-TUNE-UNIT
Damage to precision mechanical or electronic components may occur.
Be careful in handling the small parts
PACKING LIST

Be careful while using tools and assembling the parts

to avoid pinched fingers and other injuries

Do not stretch, pinch, or otherwise damage the cables
 
Do not apply incorrect voltage to the μ-TUNE-UNIT

Severe damage may occur.
Screw A
(M3x6)
8 pcs
Leg
4 pcs
Top Case
1 pc
Screw B
(M3x8)
10 pcs
Model Plate
3 pcs
Screw C
(M4x6)
8 pcs
RX-TUNE-UNIT
1 pc
Side Case F
1 pc
Screw D (M4x16)
4 pcs
Jumper Plug
1 pc
Side Case B
1 pc
Screw E
(M3x
6 with washer
2 pcs
RF Cable (RCA - RCA)
Gray 1 pc Black 1 pc
Shield Cover S
)
1 pc
Spacer S
(
)
8 mm 4 pcs
CNTL Cable (DIN - DIN)
1 pc
Shield Cover L
1 pc
Spacer L
(
18 mm
2 pcs
)
Bottom Case
1 pc
REQUIRED TOOL
Phillips Screwdriver Pliers (used for installing the Spacers)
Main Frame
1 pc
μ-TUNE-UNIT
1 pc (Separate pack)
INSTALLATION
1. Attach the Spacer S to the back side of the Main Frame with four Screws (Screw A: M3x6). There are non-painted areas on the back side.
Spacer S
Main Frame
Screw A
2. Attach the four Legs to the back side of the Main Frame with four Screws (Screw D: M4x16).
Leg
4. Affix the Model Plate to the recessed area on the Top Case, and then connect the Top Case to the μ-TUNE-UNIT with four Screws (Screw B: M3x8).
Model Plate
Screw B
μ-TUNE-UNIT
5. Attach the μ-TUNE-UNIT (which was assembled in step 4) to the Main Frame (which was assembled in step 2) with two Screws (Screw B: M3X8).
Screw B
7. Place the Main Frame upside down. Attach the RX-TUNE­UNIT to the Main Frame with the two Long Spacers (Spacer L) and two Screws (Screw E: M3X6 Screw with washer).
Spacer L
Screw E
RX-TUNE-UNIT
Main Frame
8. Connect the TMP Connector (Orange) to J1006 on the RX­TUNE-UNIT and connect the TMP Connector (Green) to J1010 on the RX-TUNE-UNIT, then connect the Flat Cable to J1007 on the RX-TUNE-UNIT.
Flat Cable
TMP Connector (Orange)
J1006
9. Confirm the μ-TUNE-UNIT Model Number (for example: MTU-80/40), and then insert the Jumper Plug into the corre­sponding labeled Jumper connector on the RX-TUNE-UNIT.
J1003
for MTU-160
J1004
for MTU-80/40
J1005
for MTU-30/20
For example, if your μ-TUNE-UNIT is MTU-80/40, insert the Jumper Plug to the J1004 that is labeled MTU-80/40. Important Note: Please confirm Jumper connection again, because the wrong connection will cause malfunction of the unit. If you turned on the RF μTUNING KIT with wrong con­nections, turn the power off and connect the Jumper Plug cor­rectly.
Jumper Plug
Screw D
3. Attach the Side Case F and Side Case B to the Top Case with eight Screws (Screw C: M4x6).
Top Case
Side Case B
Screw C
Side Case F
Screw C
6. Attach the Bottom Case to the Main Frame with four Screws (Screw B: M3X8).
Screw B
Bottom Case
J1007
TMP Connector (Green)
J1010
J1006 Connect the TMP Connector (Orange)
J1007 Connect the Flat Cable
J1010 Connect the TMP Connector (Green)
J1007 J1007
Note: 1) insure that the Flat Cable is inserted into connec-
tor J1007 squarely. If the Flat Cable is inserted di­agonally, the contacts could short and cause damage.
2) Please be careful handling the Flat Cable. Sharp bends will break the conductors and cause open or intermittent connections.
J1004
MTU-80/40
10. Affix the Shield Cover L to the RX-TUNE-UNIT with two Screws (Screw A: M3X6). Next, attach the Shield Cover S with two Screws (Screw A: M3X6). Be very careful not to pinch any wires.
Screw A
Shield Cover S
Screw A
Shield Cover L
11. Installation is completed.
12. Double check all connections and the wiring, then connect the
RF μTUNING KIT to the FT-2000, as is described in the “In­terconnections” chapter in the RF μTUNING KIT Operating Manual.