30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS |
|
PRODUCT DIMENSIONS |
GFG471LV WFG381LV
WFG371LV
Gas supply: This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. The model/serial rating plate located behind the storage drawer on the right-hand side oven door frame has information on the types of gas that can be
used. If the types of gas listed do not include the type of gas A available, check with the local gas supplier.
Provide a gas supply line of 3/4" (1.9 cm) rigid pipe to the range |
|
|
|
|
|
|
|
|
|
||||||||||||
location. A smaller size pipe on longer runs may result in insufficient |
|
|
|
|
|
|
|
|
|
||||||||||||
gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm) |
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
C |
|
|||||||||||||
minimum. Usually, LP gas suppliers determine the size and |
|
F |
|
|
|
|
|
|
|||||||||||||
|
|
|
B |
||||||||||||||||||
materials used in the system. |
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|||||||||||||
NOTE: Pipe-joint compounds that resist the action of LP gas must |
|
|
|
|
|
|
|
|
|
||||||||||||
be used. Do not use TEFLON® tape.* |
|
|
|
|
|
|
|
|
|
||||||||||||
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to |
|
|
|
|
|
|
|
|
|
||||||||||||
152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal |
|
|
|
|
|
|
|
|
|
||||||||||||
appliance connector may be used for connecting range to the gas |
|
|
|
|
|
|
|
|
|
||||||||||||
supply line. |
|
|
E |
||||||||||||||||||
A 1/2" (1.3 cm) male pipe thread is needed for connection to the |
|
|
|
|
|
|
|
|
|
||||||||||||
female pipe threads of the inlet to the appliance pressure regulator. |
|
|
|
|
|
|
|
|
|
||||||||||||
The supply line must be equipped with a manual shutoff valve. This |
|
|
|
D |
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|||||||||||||
valve should be located in the same room but external to the range. |
|
|
|
|
|
|
|
|
|
||||||||||||
It should be in a location that allows ease of opening and closing. |
|
|
A. 27¹ ⁄" (69.9 cm) max. depth with handle |
||||||||||||||||||
Electrical: 120-volt, 60-Hz, AC-only, 15-amp, fused electrical |
|
|
B. 36" (91.4 cm) cooktop height (max.) with leveling |
||||||||||||||||||
circuit is required. A separate circuit serving only this range is |
|
|
legs screwed all the way in* |
||||||||||||||||||
recommended. A time-delay fuse or circuit breaker is recommended. |
|
|
C. 46⁄" (119.1 cm) overall height (max.) with |
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
leveling legs screwed all the way in* |
||||||
*TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. |
|
|
D. 29⁄" (75.9 cm) width |
||||||||||||||||||
|
|
E. 25" (63.5 cm) |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F. Model/serial rating plate (located on the oven |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
frame behind the top left side of the oven door) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Range can be raised approximately 1" (2.5 cm) by adjusting the |
|||||||
CABINET OPENING DIMENSIONS |
|
leveling legs. |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cabinet opening dimensions shown are for 25" (64.0 cm) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
countertop depth, 24" (61.0 cm) base cabinet depth and |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
36" (91.4 cm) countertop height. |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If the cabinet depth is greater than 24" (61.0 cm), oven frame |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
must extend beyond cabinet fronts by ½" (13.0 mm) minimum. |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IMPORTANT: If installing a range hood or microwave hood |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
combination above the range, follow the range hood or |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
microwave hood combination installation instructions for |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
dimensional clearances above the cooktop surface. |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A. 18" (45.7 cm) upper side cabinet to countertop |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B. 13" (33 cm) max. upper cabinet depth |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
M |
|
|
C. 30" (76.2 cm) min. opening width |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D. For minimum clearance to top of cooktop, see NOTE*. |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
E. 30¹⁄ " (76.5 cm) min. opening width |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F. This shaded area recommended for installation of rigid gas pipe. |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G. 8" (20.3 cm) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H. Grounded outlet |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I. 17" (43.2 cm) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
J. 4¹⁄ " (11.4 cm) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K. 2" (5.1 cm) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L. 2" (5.1 cm) min. clearance from both sides of range to side wall |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
or other combustible material. |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
cabinet is covered by not less than ¹⁄" (0.64 cm) flame retardant |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
millboard covered with not less than No. 28 MSG sheet steel, |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.020" (0.5 mm) copper. |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30" (76.2 cm) minimum clearance between the top of the |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
cooking platform and the bottom of an uncovered wood or metal |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
cabinet. |
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation |
Ref. W10196160E |
Instructions packed with product. Specifications subject to change without notice. |
1/26/11 |