Whirlpool GGN2000H, GGQ9858J, LGQ8858H, LGN1000H, LGC8858E User Manual

...
0 (0)
Whirlpool GGN2000H, GGQ9858J, LGQ8858H, LGN1000H, LGC8858E User Manual

®

Gas Dryer

PRODUCT MODEL NUMBERS

GGN2000H LGQ8858H LGR5600H LGR7646J GGQ9858J LGQ8858J LGR5600J LGR8857E LGC8858E LGR3624E LGR5636E LGR8858E LGN1000H LGR3624J LGR5636J LGT7646E LGQ8800J LGR3634E LGR5644E LGW8858H LGQ8857H LGR3634J LGR5644J

LGQ8857J LGR4634E LGR5848E

Gas supply: Dryer is equipped for use with NATURAL gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2 inch IPS. When acceptable to the gas supplier and local codes, 3/8-inch approved tubing may be used for lengths under 20 feet. For lengths over 20 feet, larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, be used for connecting the appliance to the rigid gas supply line. (The gas pipe which extends through the lower rear of the appliance has 3/8-inch male pipe thread.) An individual manual shutoff valve must be installed within 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.

OVERALL DIMENSIONS

14-1/2"

42-3/8"* 6"*

9-1/4"

2-1/8"

28" max.**

dryer exhaust vent

gas burner inlet pipe connection at rear of dryer

29"

*from floor with dryer feet extended 1 inch

**Most installations will require at least 5-inch clearance behind the dryer for the dryer vent.

Electrical: 120-volt, 60-Hz, AC-only, 15or 20-amp. electrical supply. Use copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended.

Exhaust venting: Exhaust your dryer to the outside. four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.

RECESSED AREA AND CLOSET INSTALLATION

 

 

 

 

Recessed

 

 

 

 

 

 

Closet confined area

 

 

 

 

 

If a closet door is installed: The minimum unobstructed

 

 

 

 

 

 

 

area

 

air openings are required. Louvered doors with equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

air openings are acceptable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

front view

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

front view

 

 

 

 

 

 

 

 

 

 

 

side view

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48 sq. in.*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

closet

 

 

 

 

 

 

 

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

door

 

 

 

 

 

 

 

 

 

 

 

 

18"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4" **

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 sq. in.*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0"***

 

 

 

 

 

 

 

 

 

 

 

 

0"***

 

 

 

3"

 

 

 

1"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

***Wall, door and floor molding

 

* Minimum top and bottom air openings for closet door.

may require additional spacing.

 

**External exhaust elbow requires additional space.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOOR CLEARANCE

DIMENSIONS

3-7/8"

22-3/4"

19-1/8"

22-3/4"

Super-large side-swing door (reversible)

7"

22-3/4"

17-3/4"

22-3/4"

Large side-swing door (reversible)

15-1/4" 8-1/4"

15-1/4"

15-1/4"

Small side-swing door

25-5/8" 8-3/4"

13-3/4"

13-3/4"

Extra-large hamper door

EXHAUST VENTING

Preferred

 

4"

 

 

4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When you have a 4" hood

 

 

 

 

 

 

 

 

 

 

Maximum length of 4"

 

 

diameter metal vent

Number of

 

Rigid

 

Flexible

90° elbows

 

 

 

 

(fully extended)

0

 

64 ft.

 

36 ft.

1

 

54 ft.

 

31 ft.

2

 

44 ft.

 

27 ft.

3

 

35 ft.

 

25 ft.

4

 

27 ft.

 

23 ft.

 

 

 

 

 

 

 

 

Acceptable

2-1/2"

When you have a 2-1/2" hood

 

Maximum length of 4"

 

diameter metal vent

 

 

 

Number of

Rigid

Flexible

90° elbows

 

(fully extended)

0

58 ft.

28 ft.

1

48 ft.

23 ft.

2

38 ft.

19 ft.

3

29 ft.

17 ft.

4

21 ft.

15 ft.

Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Avoid making 90° turns.

When using elbows or making turns, allow as much room as possible. Bend flexible metal vent gradually to avoid kinking.

Determine vent length

1.See the exhaust vent length chart that matches your type hood for the maximum vent lengths you can use.

Do not use vent runs longer than specified in exhaust vent length charts.

2.Determine the number of elbows you will need.

3.In the column listing the type of metal vent you are using (rigid or flexible), find the maximum length of metal vent on the same line as the number of elbows.

The maximum length using a 2" x 6" rectangular vent with 2 elbows and a 2-1/2" exhaust hood is 8 ft.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 3405338 Rev. D

Instructions packed with product. Specifications subject to change without notice.

01-09-03

Loading...