Whirlpool GGQ8811P, GGQ8821P, LGQ8611P, LGQ8621P Dimension Guide

0 (0)
Whirlpool GGQ8811P, GGQ8821P, LGQ8611P, LGQ8621P Dimension Guide

®

Gas Dryer

PRODUCT MODEL NUMBERS

GGQ8811P LGQ8611P

GGQ8821P LGQ8621P

Gas supply: This dryer is equipped for use with natural gas. It is design-certified by CSA International for L.P. (propane or butane) gases with appropriate conversion. When rigid pipe is used it should be 1/2 inch IPS. When acceptable to the gas supplier and local codes, 3/8-inch approved tubing may be used for lengths under 20 feet. For lengths over 20 feet, larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, be used for connecting the appliance to the rigid gas supply line. (The gas pipe which extends through the lower rear of the appliance has 3/8-inch male pipe thread.)

A shutoff valve must be installed within 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. It is recommended that an individual manual shutoff valve be installed within 6 feet of the dryer. The location should be easy to reach for opening and closing.

Electrical: 120-volt, 60 Hz, AC-only, 15 or

20 amp electrical supply is required. (Time-delay fuse of circuit breaker is recommended.) It is recommended that a separate circuit serving only this dryer be provided.

Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.

OVERALL DIMENSIONS

43 ¹⁄ "

(110.5 cm)

 

14 ³⁄ "

*29 ¹⁄ "

(36 cm)

 

(74.3 cm)

 

* Most installations require a minimum

27"

5-1/2” (14 cm) clearance behind the

(68.6 cm)

dryer for the exhaust vent with elbow. See Installations Instructions, “Venting Requirements.”

RECESSED AREA AND CLOSET INSTALLATION

For closet installation

 

with a door, minimum

 

ventilation openings in

 

the top and bottom of

18"

the door are required.

(45.7 cm)

Louvered doors with equivalent air openings are acceptable.

 

 

3"

14" max.

 

(7.6 cm)

(35.6cm)

48 in. 2

 

 

(310 cm2 )

 

 

24 in.2

3"

 

(155 cm2 )

(7.6 cm)

1"

 

27"

1"

 

 

1"

29¹⁄ "

5¹⁄ "

 

 

 

 

 

(2.5 cm) (68.6 cm)

(2.5 cm) (2.5

cm)(74.3 cm)(14 cm)

 

 

A

 

 

 

 

B

 

 

C

A.Recessed area

B.Side view - closet or confined area

C.Closet door with vents

EXHAUST VENTING

4" (10.2 cm)

Box hood style

 

 

 

 

4"

 

 

 

Louvered style

 

 

(10.2 cm)

 

2.5"

 

 

 

 

 

 

 

(6.4 cm)

 

 

 

4"

 

 

Angled style

 

 

 

(10.2 cm)

 

 

 

 

 

 

 

 

Vent Length Chart

 

 

 

 

 

 

 

 

 

 

 

Number of

 

Type of

Box or

Angled

 

90° turns

 

vent

Louvered

hoods

 

or elbows

 

 

hoods

 

 

 

 

 

 

 

 

 

0

 

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

 

 

Flexible metal

36 ft (11 m)

28 ft (8.5 m)

 

 

 

 

 

 

 

1

 

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

 

 

Flexible metal

31 ft (9.4 m)

23 ft (7 m)

 

 

 

 

 

 

 

2

 

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

 

 

Flexible metal

27 ft (8.2 m)

19 ft (5.8 m)

 

 

 

 

 

 

 

3

 

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

 

 

Flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

 

 

 

 

 

 

 

4

 

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

 

 

Flexible metal

23 ft (7 m)

15 ft (4.6 m)

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns.

2.Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.

3. Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.

In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 8562583

Instructions packed with product. Specifications subject to change without notice.