Whirlpool GEQ8811PW0, GEQ8811PL0, LEQ8611PW0, LEQ8611PG0, GEQ8811PG0 Installation Instructions Manual

0 (0)
27IN.(69CM)ELECTRICDRYERINSTAILATION
INSTRUCTIONS
INSTRUCCIONESDEINSTALACIONPARALASECADORA
p
ELECTRICADE27PULG.(69CM)
TableofContents/Indice
DRYER SAFETY ............................................... 1
INSTALLATION INSTRUCTIONS .................... 2
Lecatien Requirements ................................ 2
Electrical Requirements ................................ 3
Electrical Cennectien .................................... 4
Plan Vent System .......................................... 8
Install Vent System ...................................... 10
Install Leveling Legs .................................... t0
Level Dryer ................................................... 11
Connect Vent ............................................... 11
Complete Installation ................................... 11
SEGURIDAD DE LA SECADORA .................. 12
INSTRUCCIONES DE INSTALACI(_N ........... 12
Herramientas y piezas ................................. t 2
Requisites de Iocalizaeion .......................... t 2
Requisites el6ctrioos .................................... t3
Requisites de ventilaeion ............................. t 9
Planificaci6n del sistema de ventilaci6n......20
Instalacion del sistema de ventilaci6n ......... 22
Instalaci6n de las patas niveladoras ............ 22
Nivelacion de la secadora ............................ 23
Conexi6n del ducto de escape .................... 23
Complete la instalaci6n ............................... 23
DRYERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
8535833
INSTAILATIONINSTRUCTIONS
Check that you have everything necessary for correct installation. Proper installation is your responsibility.
Flat-blade screwdriver Level Adjustable wrench that
opens to 1 in. or hex- head socket wrench (for
adjusting dryer feet) #2 Phillips screwdriver Tin snips (new vent
installations)
Safety glasses
Caulking gun and compound (for installing new exhaust vent)
Gloves
Wire stripper (direct wire installations)
Parts supplied:
Remove parts package from dryer drum. Check that all parts were included.
4 levelinglegs
Parts needed:
Check local codes. Check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements" before purchasing parts.
Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased
your dryer. For further information, please reference the
"Assistance or Service" section of your "Dryer User Instructions."
A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of 200 Ibs (90.7 kg).
A level floor with a maximum slope of 1 in. (2.5 cm) under entire dryer. (If slope is greater than 1 in. [2.5 cm], install Extended Dryer Feet Kit, Part No. 279810.) Clothes may not
tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended. Install the dryer where it is protected from water and/or weather. Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
Explosion Hazard
Keep flammabme materiams and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (48 cm) above the floor
for a garage installation.
Failure to do so can resumt in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. See "Venting Requirements."
A separate 30 amp circuit.
* Most installations require a minimum 51/2in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
Minimum installation spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are acceptable.
Companionappliancespacingshouldalsobeconsidered.
14" max
4cmo'oPH
1" _ _- 27" -_ _--1" -_1" < _61,4,,_l_',"_-
(25cra) (686cm) (25cn (25cm) (743cm) (14cm}
m
(310 cra)- "
24"2
{76 crn)
]
-3"
(76 cm)
7
1. Recessed area
2. Side view - closet or confined area
3. Closet door with vents
Mobile Home-Additional Installation Requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware which is available for purchase from your dealer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer exhaust opening.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances. A copy of the above code standards can be obtained from:
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240-volt, 60-Hz., AC-only electrical supply (or 3 or 4 wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions provided for it here.
If local codes do not permit the connection of a cabinet ground connector to the neutral wire, see "Optional 3-wire connection" section.
This dryer is manufactured with a 3-wire, cabinet-ground conductor connected to the NEUTRAL (white or center wire) of the wiring harness at the terminal block.
Use a 4-wire conductor cord when the dryer is installed in a mobile home or an area where local codes do not permit
grounding through the neutral.
If using a power supply cord: Use a UL approved power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL approved 30 amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must
end in ring terminals or spade terminals with upturned ends.
A UL approved strain relief.
If your outlet looks like this:
4-wire receptacle (14-30t:?)
Then choose a 4-wire power supply cord with ring or spade terminals and UL approved strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have 4, 10 gauge solid
copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
If your outlet looks like this:
@
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade terminals and UL approved strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have 3, No.-10 copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armored or non-metallic sheathed copper cable (with ground wire). All current-carrying wires must be insulated.
10 gauge solid copper wire (do not use aluminum).
At least 4 ft (1.22 m) long.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer: This dryer must be grounded, in the event of malfunction or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and ground- ed in accordance with all local codes and ordinances.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be
run with the circuit conductors and connected to the equip- ment-grounding terminal or Headon the dryer.
WARN(NG: improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is proper- ly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a
qua)ified electr(cian.
SAVE THESE INSTRUCTIONS
PowerSupplyCord DirectWire
Fire Hazard Use a new UL approved 30 amp power supply cord, Use a UL approved strain relief.
Disconnect power before making emectrical connections. Connect neutram wire (white or center wire} to center
terminal (silver),
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 suppmy wires to remaining 2 terminals (goBd).
Securemy tighten aH electrical connections, FaiBure to do so can resumt in death, fire, or
emectrical shock,
1.
2.
Disconnect power. Remove the hold-down screw and terminal block cover.
1 2 3 4
Fire Hazard
Use 10 gauge soJid copper wire, Use a UL approved strain relief.
Disconnect power before making emectrica_ connections.
Connect neutral wire (white or center wire) to center terminal (simver).
Ground wire (green or bare wire} must be connected to green ground connector,
Connect remaining 2 suppmy wires to remaining 2 terminals (gold).
Securely tighten aH emectrical connections.
Failure to do so can result in death, fire, or
emectrical shock.
Assemble a 3/4in. (1.9 cm) UL approved strain relief (UL marking on strain relief) into the hole below the terminal block
opening. Tighten strain relief screws just enough to hold the two clamp sections together. Put power supply cord through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position.
1. Terminal block cover
2. External ground connector
3. Center, silver-colored terminal block screw
4. Hold-down screw
5. Neutral grounding wire (green/yellow)
6. Hole below terminal block opening
5
6
Now complete installation following instructions for your type of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has: And you will be Go to Section
connecting to:
4-wire receptacle A UL listed, 120/ 4-wire connection: (NEMA Type 14-30R) 240 volt Power Supply
minimum, 30 Cord amp., dryer power supply
cord*
4-wire direct A fused 4-wire connection:
disconnect or Direct Wire circuit breaker
box*
3-wire receptacle A UL listed, 120/ 3-wire connection: (NEMA type 10-30R) 240 volt Power Supply
minimum, 30 Cord
amp., dryer
power supply cord*
3-wire direct A fused 3-wire connection:
disconnect or Direct Wire circuit breaker
box*
*If local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to "Optional 3-wire connection" section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
2 6
5 7
1,4-wire receptacle (NEMA type !4-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned ends
6. _ in. (1.9 cm) UL approved strain relief
7. Ring terminals
1. Remove center terminal block screw.
2. Remove appliance ground wire (green with yellow stripes) from external ground connector screw. Fasten it under center,
silver-colored terminal block screw.
.................................
1. External ground connector - Dotted line shows position of NEUTRAL ground wire before being moved to center terminal block screw
2. Center silver-colored terminal block screw
3. Green/yellow wire of harness
3. Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
4. Connect neutral wire (white or center wire) of power supply cord under center screw of the terminal block.
2 5
3
1. External ground connector
2. Green wire of power supply cord or bare copper wire
3. _ in. (1,9 cm) UL-listed strain relief
4. Center silver-colored terminal block screw
5. Neutral wire (white or center wire)
6. Neutral grounding wire (green/yellow)
5. Connect the other wires to outer terminal block screws. Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3 wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5 in. (12.7 cm). Cut 11/2in. (3.8 cm) from 3 remaining wires. Strip insulation back 1 in. (2.5 cm). Shape ends
of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw.
1. Remove center terminal block screw.
2. Remove appliance ground wire (green with yellow stripes) from external ground connector screw. Fasten it under center,
silver-colored terminal block screw.
.................................3
1. External ground connector - Dotted line shows position of NEUTRAL ground wire before being moved to center terminal block screw
2. Center silver-colored terminal block screw
3. Green/yellow wire of harness
3. Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw.
Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together. Tighten screw.
!. External ground connector
2. Green wire of power supply cord or bare copper wire
3. ¾ in. (1.9 cm) UL-listed strain relief
4. Center silver-colored terminal block screw
5. Neutral wire (white or center wire)
6. Neutral grounding wire (green/yellow)
Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!! !!
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
7 6
1.3-wire receptacle (NEMA type 10-30R)
2. 3-wire plug
3. Neutral prong
4. Spade terminals with up turned ends
5. ¾ in. (1.9 cm) UL approved strain relief
6. Ring terminals
7. Neutral wire (white or center wire)
1=
2.
Loosen or remove center terminal block screw. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
2
4
Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together. Tighten screw.
4
5
5
1. External ground connector
2. Neutral grounding wire (green/yellow)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5. _ in. (1.9 cm) UL-ilsted strain relief
3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten strain relid screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 31/2in. (8.9 cm) of outer covering from end of cable. Strip insulation back 1 in. (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example below.
1. Loosen or remove center terminal block screw.
1.External ground connector
2. Neutral grounding wire (green/yellow)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5. ¾ in. (1.9 cm) UL-Iisted strain relief
Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral
wire.
1. Remove center terminal block screw.
2. Remove appliance ground wire (green with yellow stripes) from external ground connector screw. Connect appliance
ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.
3. Connect the other wires to outer terminal block screws. Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
6. Connectaseparatecoppergroundwirefromtheexternal groundconnectorscrewtoanadequateground.
1. External ground connector
2. Neutral grounding wire (green/yellow)
3. Neutral wire (white or center wire)
4. Grounding path determined by a qualified electrician
Fire Hazard
Use a heavy metaB vent, Do not use a pmaetic vent,
Do not use a metam foil vent. Failure to follow these instructions can result in death
or fire.
WARNING; To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
4 in. (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE TM venting products are recommended.
DURASAFE TM vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the "Assistance or Service" section of your "Dryer User Instructions."
Do not exhaust the dryer into any gas vent, chimney, wall, ceiling, or a concealed space of a building.
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or floors.
Do not use screws or other fastening devices that extend into the interior of the vent to secure vent.
IMPORTANT: Observe all governing codes and ordinances.
_mproper venting can cause moisture and mintto collect indoors, which may resumt in:
[] Moisture damage to woodwork, furniture, paint, waif
paper, carpets, etc.
[] Housecleaning problems and health problems.
Use a heavy metal vent. Do not use plastic or metal foil vent. Rigid metal vent is recommended to prevent crushing and kinking.
Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.
An exhaust hood should cap the vent to prevent rodents and insects from entering the home.
Exhaust hood must be at least 12in. (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers,
rocks or bushes, etc.). If using an existing vent system, clean lint from the entire length of
the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible
metal vent. Use clamps to seal all joints. Do not use duct tape, screws or
other fastening devices that extend into the interior of the vent to secure vent.
Typical exhaust installations Typical installations vent the dryer from the rear of the dryer. Other
installations are possible.
1
2
4
............8
1. Dryer
2. Elbow
3. Wall
4. Exhaust hood
5. Clamps
6. Rigid metal or flexible metal vent
7. Vent length necessary to connect elbows
8. Exhaust outlet
Loading...
+ 16 hidden pages