Welch Allyn Home Scale is a trademark of Welch Allyn.
Welch Allyn assumes no responsibility for any injury to anyone, or for any illegal or improper use of the
product, that may result from failure to use this product in accordance with the instructions, cautions,
warnings, or statement of intended use published in this manual.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any
use of such marks by Welch Allyn is under license.
The Welch Allyn Home
measure weight in a home environment.
This Directions for use contains important safety and care information and provides step
by step instructions for using the scale. Read the manual thoroughly before using the
scale.
Scale is intended for adults and children (10-17 years old) to
1
For information about any Welch Allyn product, contact Welch Allyn Home technical
support at www.welchallynhome.com/support.htm.
Indications for use
The Welch Allyn Home Scale is intended for adults and children (10–17 years old) to
measure weight in the home.
Contraindications
This device is contraindicated for any person who is connected to a wearable or
implantable electronic device or instrument, such as a pacemaker or defibrillator.
Symbols
Documentation symbols
Warning: The warning statements in this manual identify conditions or practices that could lead to
illness, injury, or death. Warning symbols will appear with a grey background in a black and white
document.
Caution: The caution statements in this manual identify conditions or practices that could result in
damage to the equipment or other property, or loss of data.
Mandatory - Consult Directions for Use
Page 6
2 Introductory informationWelch Allyn Home™ Scale
Power symbols
Direct current (DC)
Shipping, storing, and environment symbols
Humidity limitationSeparate collection of
Electrical and Electronic
Equipment. Do not
dispose as unsorted
municipal waste.
Temperature limitAtmospheric pressure
limitation
RecycleStacking limit by number
Connectivity symbols
Bluetooth® wireless technology enabled
Miscellaneous symbols
Serial number
Product identifier, product family catalogue numberNon-ionizing electromagnetic
Reorder number, Model numberGlobal Trade Item Number
IP22
The ingress protection: the device could protected against
solid foreign objects of 12.5mm and greater, and against
vertically falling water drops when ENCLOSURE tilted up
to 15°
Manufacturer
radiation
Type BF applied parts
Page 7
Directions for use Introductory information 3
About warnings and cautions
Caution statements can appear on the Welch Allyn Home Scale device, packaging,
shipping container, or in this Directions for use.
The Welch Allyn Home Scale is safe for users when used in accordance with the
instructions and caution statements presented in this Directions for use.
Before using the device, you must familiarize yourself with all cautions, with the steps to
power up the device, and with the sections of this Directions for use that pertain to your
use of the device. In addition to reviewing the general cautions presented in the next
section, you must also review the more specific cautions that appear throughout the
manual in conjunction with setup/startup, operation, and maintenance tasks.
•Failure to understand and observe any warning statement in this manual could lead
to injury or illness.
•Failure to understand and observe any caution statement in this manual could lead to
damage to the equipment or other property, or loss of data.
General warnings and cautions
Warning Injury risk. Do not use the scale on a slippery floor, such as tile.
Warning Injury risk. Do not jump onto the platform immediately after
bathing or with wet hands.
Warning Injury risk. Dispose of accessories, detachable parts, and the
device according to the local guidelines.
Warning Injury risk. No modification of this equipment is allowed.
Modifying the equipment could damage the device or cause injury.
Warning Injury risk. Do not touch output of the batteries and the user
simultaneously.
Warning Injury risk. Before use, make sure the device functions safely and
is in proper working condition. Failure to do so could damage the device or
cause injury.
Warning Possible injury risk. The device contains small parts. Keep the
device away from children and pets.
CAUTION Avoid storing the device where the device may be exposed to
extreme temperatures, humidity, moisture, direct sunlight, dust, or salt air.
CAUTION Avoid storing the device where there is risk of shock or
dropping.
CAUTION Avoid storing the device where you store chemicals.
CAUTION Avoid storing the device where there are corrosive gases.
CAUTION Avoid storing the device near infants or children.
Page 8
4 Introductory informationWelch Allyn Home™ Scale
CAUTION Do not attempt to repair the unit yourself in the event of
malfunctions. Only have repairs carried out by authorized service centers.
CAUTION Do not use rechargeable batteries.
CAUTION Use the scale in the environment described in this Directions
for use. Using the scale in other environments will compromise the
performance of the scale and reduce the lifetime of the scale.
Content list
The following items are in the device box:
•Home Scale
•(4) AAA alkaline batteries (1.5V each)
•(4) extension feet for use on carpet
•Directions for use
Controls and indicators
Scale top
The Welch Allyn Home scale is simple to use.
FeatureDescription
No.
1LCD displayDisplays measurement
Page 9
Directions for use Introductory information 5
No. FeatureDescription
2UNIT / Power buttonThe button enables you to select kg or lb unit measure. Press and
4Sensors (4)4 load cell sensors which conduct weight measurement
Screen elements
The liquid crystal display (LCD) display registers the measurement. The display also may
show other icons that provide information about the functionality of the scale.
IconDescriptionIconDescription
kg
Kilogram
Low battery chargeFull battery charge
Bluetooth wireless
technology is powered on
Data being transferred
using Bluetooth wireless
technology (dotted area
flashes)
lb
Pound
Bluetooth wireless technology
connected (dotted area is not
flashing)
Scale not paired with device
Page 10
6 Introductory informationWelch Allyn Home™ Scale
Page 11
Use the scale
Startup
The Welch Allyn Home scale uses SENSE ON™ technology to turn on the scale. Step on
the scale with bare feet to begin a measurement.
Insert or replace the batteries
7
CAUTION When the symbol appears, the device will power off
in four seconds. Replace the old batteries with a new set of four batteries.
Always replace all four batteries with new batteries. Do NOT mix old
batteries with new batteries.
CAUTION Remove the batteries if the device is not to be used for some
time.
CAUTION Dispose old batteries by following your local recycling
guidelines.
CAUTION Do not burn batteries. Batteries may leak or explode.
1. Open the battery door on the under side of the scale.
2. Insert the four AAA alkaline batteries (1.5V each) into the battery compartment
according to the polarity indications marked inside the battery compartment.
3. Close the battery door.
4. Wait until the digits “0.0lb”appear on the LCD screen.
Install the carpet feet
Install the carpet feet if you use the device on carpet to avoid the device slipping.
Peel off and removethe rubber stickers on the four corner posts.
1.
2. Remove the four carpet feet from the packaging.
3. Insert the carpet feet prongs into the posts.
Page 12
8 Use the scaleWelch Allyn Home™ Scale
Pair a smartphone, a tablet, or a communication hub with
the scale
Advanced Bluetooth 4.0 technology enables your smartphone, tablet, or a
communication hub to receive your personal health information from your device. You
have two alternatives to pair your device with these devices.
•If you are using the Welch Allyn Home application, follow the pairing instructions
presented in the application.
•Contact your Remote Monitoring Solution provider or use the instructions that office
provided to set up these communications devices.
With either alternative, you complete the same steps on the Home scale.
1. Confirm that both the smart device and the Home scale are powered on.
NoteBluetooth wireless connectivity is only available for devices
which support Bluetooth 4.0 technology.
2. Press and hold the Unit / Power button on the bottom of the scale for 3 seconds.
The Bluetooth pairing sequence is activated. The dotted line surrounding the
Bluetooth symbol flashes while discovering the weight scale.
If successful, a steady
LCD screen. If unsuccessful, the
symbol surrounded by a dotted line appears on the scale's
appears.
Select the measurement unit
The default measurement unit is pound (lb).
Press the Unit / Power button on the bottom of the scale to change from pound (lb)
to kilogram (kg).
Ensure accurate measurements
To ensure the accuracy of measurements, follow the recommendations below when you
start a measurement.
•
Place the scale on a flat, hard surface for at least 10 seconds. Obtaining the
measurement immediately after placing the scale on a flat, hard surface may affect
the accuracy of the measurement.
•If you place the scale on carpet, fit the extension feet before taking the
measurement. Placing the scale sensors directly on carpet may affect the accuracy
of the measurement.
•Always start a measurement at the same time on the same scale located on the
same flat surface.
Page 13
Directions for use
Obtain measurement
With the original SENSE ON patent technology, the scale automatically powers on when
you step on the platform in your bare feet.
1. Step on the platform in your bare feet.
The scale automatically powers on and begins the measurement.
2. Stand still and keep full contact with the scale until the LCD stops blinking and
displays the weight.
Stop a measurement
You can stop a measurement before it is complete.
Step off the platform.
The scale returns to a ready / zero state.
After approximately 2 seconds, the scale powers down automatically.
Use the scale 9
Maintain the scale
Warning Injury risk. Keep the device clean. Contact with a contaminated
device can spread infection. Clean the device after each use.
NoteThe Home scale does not require calibration.
To get the best performance from your Home scale, follow the maintenance steps
below.
•
Store the device in a dry place away from direct sunlight.
•Avoid shaking and dropping the device
•Avoid operating the device in dusty and unstable temperature environments.
CAUTION Use a soft cloth to clean the entire device. Do not use any
abrasive or volatile cleaners.
The following agents are compatible with the device:
•
70 percent isopropyl alcohol
•10 percent chlorine bleach/90 percent water solution
1. Clean the Home scale only when necessary with one of the compatible cleaning
agents listed above.
2. If necessary, wipe the device with a soft, damp cloth.
Troubleshooting
This section includes a list of error messages and frequently asked questions for
problems you may encounter with your Home scale. If the device is not operating as you
think it should, check here before arranging for servicing.
Page 14
10 Use the scaleWelch Allyn Home™ Scale
Error prompt
ErrorDescriptionSolution
Dotted linesOverload. The device will power offWeight exceeds scale maximum
Low Battery. The device will power off
in four seconds.
Error conditionAt any point, when a situation occurs
that prevents a successful test
acquisition, an error code will be
displayed in the LCD area. The
message will persist for several
seconds until the device times out and
powers down.
E02Movement while weighingRemain motionless while weighing
Weight fluctuatesPlacement on scale is improperPlace scale on hard ground, then weigh
Moved scalePlace scale on hard ground, then weigh
Cannot power on scaleBatteries inserted improperlyMove scale and insert batteries.
Scale haltedElectrostatic interferenceMove scale and insert batteries.
Replace all four batteries at the same
time. Purchase the authorized batteries
for replacement.
Check the following items:
•Bluetooth wireless technology is
on.
•The application is on.
•Both devices are within the
transmission distance of
Bluetooth devices.
again after returning scale to 0.0 kg.
again after returning scale to 0.0 kg.
Reboot the scale and weigh again.
Reboot the scale and weigh again.
When measuring
Problem
No display on the LCD screen or display
flickers with the scale powers on
The scale powers off automatically
"Bat" symbol appears for 3 seconds
then the scale powers off
Measurement fluctuates by several
pounds from last measurement
Root causeSolution
Batteries are not installed or not
installed properly
Worn batteriesReplace all four batteries at the same
Low Battery.
No batteriesReplace all four batteries at the same
Scale was not placed on a hard, flat
surface for at least 10 seconds before
obtaining measurement
Install the batteries. Go to "Insert or
replace the batteries"
time. Purchase the authorized batteries
for replacement.
Replace all four batteries at the same
time. Purchase the authorized batteries
for replacement.
time. Purchase the authorized batteries
for replacement.
Place the scale on a hard, flat surface
for at least 10 seconds before stepping
Page 15
Directions for use Use the scale 11
ProblemRoot causeSolution
onto the scale to begin the
measurement
When transmitting data
ProblemRoot causeSolution
Data transmission failedBluetooth wireless technology is offTurn on the Bluetooth wireless
technology via the Settings.
Application is off
Out of range of Bluetooth transmission. Place your mobile or portable device
Press the icon to run your application.
closer to the scale.
Page 16
12 Use the scaleWelch Allyn Home™ Scale
Page 17
Appendices
Specifications
13
Warning
: No modification of this equipment is allowed.
ItemSpecification
Power supply
Display modeBlue LCD with White Backlight V.A.: 74x53mm
Measurement unitKilogram / Pound
Measurement range
Resolution
Normal working conditionTemperature: 5℃ (41°F) to 40℃
Storage & transportation
condition
6V 4*AAA alkaline batteries
5kg to 200kg / 11lb to 441lb
The measurement resolution
shall be:
0–100kg: 0.1kg
100–200kg: 0.2kg
(104°F)
Atmospheric pressure: 86kPa to 106kPa
Temperature:-20℃ (-4°F) to 60℃
(140°F)
0–220 lb: 0.2lb
220–440lb: 0.5lb
Humidity: ≤ 85%RH
Relative Humidity: 10% RH–93% RH
Atmospheric Pressure: 50kPa to 106 kPa
Net WeightApproximately 2.75kg (6.1 lb.) ( Excluding the dry cells)
Dimensions360mm x 408mm x 32.5mm (14.2inches x16.1inches x 1.3inches) with carpet feet
Accessories
Mode of operationContinuous operation
•(4) AAA alkaline batteries
•(4) extension feet
•Directions for use
Page 18
14
AppendicesWelch Allyn Home™ Scale
ItemSpecification
Auto-ONSENSE ON technology
Auto-OFFAbout 15 seconds when showing 0.0
About 15 seconds after the weight data is locked
Degree of protectionType BF applied part
Protection against ingress of
water
Software VersionVersion 1.0
IP22
General radio compliance
ItemSpecification
Bluetooth Module No.AW51822
RF Frequency Range2402 MHz to 2480 MHz
Output Power4.0 dBm
Supply Voltage1.8-3.6 V
Antenna Gain0dBi
Transmitting Distance10 meters, (30 feet)
Federal Communication Commission (FCC) Interference Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions.
•This device may not cause harmful interference.
•This device must accept any interference received, including interference that may
cause undesired operation.
This equipment (FCC ID: OU9BS-1507) has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one of
the following measures.
1.Reorient or relocate the receiving antenna.
2.Increase the separation between the equipment and receiver.
Page 19
Directions for use Appendices 15
3.Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Industry Canada (IC) compliance
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Cet appareil est conforme aux normes RSS exemptes de licence de l'Industry Canada.
Son fonctionnement est soumis aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
This radio transmitter (IC: 12725A-BS1507) has been approved by Industry Canada to
operate with the antenna listed in the specification table.
Ce transmetteur de radio (C: 12725A-BS1507) a été approuvé par l'Industry Canada pour
fonctionner avec l'antenne répertoriée dans la table des spécifications.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Complied standards list
ItemStandard
Risk managementISO/EN 14971 Medical devices — Application of risk
LabelingISO/EN 15223-1 Medical devices. Symbols to be used with
User manualEN 1041 Medical equipment manufacturers to provide
General Requirements for Safety
management to medical devices
medical device labels, labeling and information to be
supplied. General requirements
Tested in accordance with ISO 10993 Biocompatibility
information
IEC 60601-1+A1 Medical electrical equipment - Part 1:
General requirements for basic safety and essential
performance
IEC 60601-1-11 Medical electrical equipment - Part 1-11:
General requirements for basic safety and essential
performance - Collateral standard: Requirements for
Page 20
16 AppendicesWelch Allyn Home™ Scale
ItemStandard
medical electrical equipment and medical electrical
systems used in the home healthcare environment
Electromagnetic compatibilityIEC/EN 60601-1-2 Medical electrical equipment - Part 1-2:
General requirements for basic safety and essential
performance - Collateral standard: Electromagnetic
compatibility - Requirements and tests
Software life-cycle processes
Usability
IEC/EN 62304+AC Medical device software - Software life
cycle processes
IEC 62366 Medical devices - Application of usability
engineering to medical devices (IEC 62366)
IEC 60601-1-6 Medical electrical equipment - Part 1 -6 :
General requirements for basic safety and essential
performance - collateral standard : Usability
Emissions and immunity information
The Welch Allyn Home Scale RPM-SCALE100 is intended for use in the electromagnetic
environment specified below. The customer or user of the Welch Allyn Home Scale
should assure that it is used in such an environment.
This equipment needs to be installed and put into service in accordance with the
information provided in the user manual.
CAUTION Wireless communications equipment, such as wireless home
network devices, mobile phones, cordless telephones and their base
stations, walkie-talkie can affect this equipment and should be kept at least
a distance d=3,3m away from the equipment.
NoteAs indicated in Table 6 of IEC 60601-1-2:2007 for ME Equipment, a typical
cell phone with a maximum output power of 2 W yields d=3,3m at an
IMMUNITY LEVEL of 3V/m).
Electromagnetic emissions
The Welch Allyn Home Scale is intended for use in the electromagnetic environment specified below. The customer or
user of the Welch Allyn Home Scale should assure that it is used in such an environment.
Group 1The Welch Allyn Home Scale uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are not likely to
cause any interference in nearby electronic equipment.
Class B
Not applicable
The Welch Allyn Home Scale is suitable for use in all establishments
other than domestic establishments and those directly connected to the
public low-voltage power supply network that supplies buildings used
for domestic purposes.
Page 21
Directions for use Appendices 17
Electromagnetic emissions
Voltage fluctuations/
Not applicable
flicker emissions
IEC 61000-3-3
Electromagnetic immunity
The Welch Allyn Home Scale is intended for use in the electromagnetic environment specified below. The customer or
the user of the Welch Allyn Home Scale should assure that it is used in such an environment.
Immunity testIEC 60601 test level Compliance levelElectromagnetic environment - guidance
Electrostatic discharge
(ESD)
IEC 61000-4-2
Electrical fast
transient/burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
±6 kV contact
± 8 kV air
±2 kV for power supply
lines
± 6 kV contact
± 8 kV air
±2 kV for power supply
lines
± 1 kV line(s) to line(s) ± 1 kV differential
mode
<5% U
T
(>95% dip in UT) for 0.5
cycle
40% U
T
(60% dip in UT) for 5
cycles
<5% U
T
(>95% dip in UT) for 0.5
cycle
40% U
T
(60% dip in UT)for 5
cycles
Floors should be wood, concrete or ceramic
tile. If floors are covered with synthetic
material, the relative humidity should be at
least 30%.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment. If the user
of the Welch Allyn Home Scale requires
continued operation during power mains
interruptions, it is recommended that the
Welch Allyn Home Scale be powered from an
uninterruptible power supply or a battery.
Power frequency
(50Hz) magnetic field
IEC 61000-4-8
70% U
T
(30% dip in UT) for 25
cycles
<5% U
T
(>95% dip in UT) for 5
seconds
3A/m3A/mPower frequency magnetic fields should be at
70% U
T
(30% dip in UT) for 25
cycles
<5% U
T
(>95% dip in UT) for 5
seconds
levels characteristic of a typical location in a
typical commercial or hospital environment.
Note: UT is the AC mains voltage prior to application of the test level.
Electromagnetic immunity
The Welch Allyn Home Scale is intended for use in the electromagnetic environment specified below. The customer or
the user of the Welch Allyn Home Scale should assure that it is used in such an environment.
Page 22
18 AppendicesWelch Allyn Home™ Scale
Electromagnetic immunity
Immunity testIEC 60601 test level Compliance levelElectromagnetic environment - guidance
Portable and mobile RF communications
equipment should be used no closer to any part
of the Welch Allyn Home Scale, including
cables, than the recommended separation
distance calculated from the equation
applicable to the frequency of the transmitter.
Recommended separation distance
Conducted RF
IEC 61000-4-6
Radiated RF
3 Vrms
3 Vrms
150 kHz to 80 MHz
3 V/m 80 MHz to 1 GHz 3 V/m
d= (1.167)
d= (1.167) 80 to 800 MHz
IEC 61000-4-3
d= (2.333) 800 MHz to 2,5 GHz
whereP is the maximum output power rating of
the transmitter in watts (W) andd is the
recommended separation distance in meters
(m). Field strengths from fixed RF transmitters,
as determined by an electromagnetic site
surveya, should be less than the compliance
level in each frequency rangeb. Interference
may occur in the vicinity of equipment marked
with the following symbol:
Note1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the Welch Allyn Home Scale is used exceeds the
applicable RF compliance level above, the Welch Allyn Home Scale should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Welch
Allyn Home Scale.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distances between portable and mobile RF communications
equipment and the Welch Allyn Home Scale
The Welch Allyn Home Scale is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or user of the Welch Allyn Home Scale can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the
Welch Allyn Home Scale as recommended below, according to the maximum output power of the communications
equipment.
Page 23
Directions for use
Appendices 19
Recommended separation distances between portable and mobile RF communications
equipment and the Welch Allyn Home Scale
Separation distance according to frequency of transmitter (m)
Warranty
Rated max. output
power of transmitter
(W)
0.010.1670.1670.233
0.10.3690.3690.738
11.1671.1672.333
103.6903.6907.338
10011.6711.6723.33
For transmitters rated at a maximum output power not listed above, the recommended separation distanced in meters
(m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output
power rating of the transmitter in watts (W) according to the transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
150 kHz to 80 MHz
d= (1.167)
80 MHz to 800 MHz
d= (1.167)
800 MHz to 2.5 GHz
d= (2.333)
Welch Allyn will warranty the Home Scale to be free of defects in material and
workmanship and to perform in accordance with manufacturer specifications for the
period of two years from the date of retail purchase.
The warranty period shall start on the date of purchase. The date of purchase is: 1) the
invoiced ship date if the device was purchased directly from Welch Allyn, 2) the date
specified during product registration, 3) the date of purchase of the product from a
Welch Allyn authorized distributor as documented from a receipt from said distributor.
This warranty does NOT cover damages caused by misuse or abuse, including but not
limited to:
•
Failure caused by unauthorized repairs or modifications
•Damage caused by shock or dropping during transportation
•Damage caused by improper use of the power supply
•Failure caused by improper operation not consistent with the instructions stated in
this Directions for use
Should this device require maintenance (or replacement at our option) under warranty,
please deliver the original package to Welch Allyn prepaid. Please return the store receipt
(with the retail purchase date) and a note with the reasons for the return.
Page 24
20 AppendicesWelch Allyn Home™ Scale
Approved accessories
ItemDescription
RPM-SCALEACC-01 Carpet Feet 40EA
Page 25
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.