DVMEMF – MICROWAVE LEAKAGE DETECTOR
1. Introduction
To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer. Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
According to a survey 56% of the microwave ovens older than 2 years present a leakage radiation level 10% higher than the safety standard of 5mW/cm². Independent studies have revealed that exposure to levels higher than this standard can cause skin cancer, headaches, dizziness, cataracts, increased stress, temporary sterility in men … Since microwave radiation is odourless and invisible and therefore hard to detect, this detector can help you to determine the radiation level leakage at home. If the meter does detect a dangerous leak, you should not use the microwave oven until it is properly repaired.
2. Use
Press to switch on the detector. Press and hold ZERO to adjust the zero point. Approach the detector to take the measurement. Press MAX to display the maximum value, press to activate the backlight. Switch off the detector by pressing .
3. Technical Specifications
Range 0 ~ 9.99mW/cm² Warning Value 5.0mW/cm² Accuracy ± 1dB Power Supply 1 x 9V alkaline E-block (order code 6LR61, incl.) Working Temperature 0°C ~ 40° C Relative Ambient Humidity 0% ~ 85% Dimensions 160 x 60 x 42mm Weight 150g Contents detector, manual, battery, carrying case
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice.