3-IN-1 THERMOMETER / IR – THERMISTOR PROBE – CLAMP
3-IN-1 THERMOMETER / IR – THERMISTORSONDE – KLEM
THERMOMÈTRE 3 EN 1 / IR – SONDE À THERMISTANCE – PINCE
TERMÓMETRO 3 EN 1 / IR – SONDA TERMISTOR – PINZA
USER MANUAL 3
GEBRUIKERSHANDLEIDING 8
NOTICE D’EMPLOI 13
MANUAL DEL USUARIO 18
BEDIENUNGSANLEITUNG 23
To all residents of the European Union
Important environmental information about this product
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before
bringing this device into service. If the device was damaged in transit, don't
install or use it and contact your dealer.
2. Safety Instructions
3. General Guidelines
Refer to the Velleman® Service and Quality Warranty on the last pages
of this manual.
• Protect this device from shocks and abuse. Avoid brute force when
• Protect the device against extreme heat and dust.
• Familiarise yourself with the functions of the dev ice befor e actually
• All modifications of the device are forbidden for safety reasons. Damage
• Only use the device for its intended purpose. Using the device in an
This symbol on the device or the package indicates that disposal of
the device after its lifecycle could harm the environment. Do not
dispose of the unit (or batteries) as unsorted municipal waste; it
should be taken to a specialized company for recycling. This device
should be returned to your distributor or to a local recycling
service. Respect the local environmental rules.
Keep this device away from children and unauthorized users.
Keep this device away from rain, moisture, splashing and
dripping liquids.
Do not hold the IR-thermometer too long to objects that
continuously generate high heat (e.g. hot plate) t o avoid damag e
to the housing.
operating the device.
using it.
caused by user modifications to the device is not covered by the
warranty.
unauthorised way will void the warranty.
• Damage caused by disregard of certain guidelines in this manual is not
covered by the warranty and the dealer will not accept responsibility for
any ensuing defects or problems.
• Keep this manual for future reference.
4. Features
• temperature readout in °C or °F
• data hold
• lock feature for continuous scanning
• over range indication
• automatic p ow er off
• adjustab le em issivity
• resolution 0.1°C (0.1°F )
5. Overview
Refer to the illustrations on page 2 of this manual.
IR LCD
B2 probe/clamp LCD G clamp trigger
ON/OFF butt on
6. Operation
• The thermometer can measure temperat ur e in 3 ways, using IR, probe
or clamp. The desired way will determine how to switch on the
thermometer:
o to use the IR sensor [A], press the IRT button [D].
o to use the clamp [H], press the ON/OFF button [F].
o to use the probe [I], first unfold the probe [I], and then press the
ON/OFF butt on [F].
• In hold mode, the thermometer will automatically s witch of afte r ± 15 s,
in continuous mode after ±20min.
IR-mode
• All data is shown on the IR LCD [B1].
• Aim the IR sensor [A] towards the target and press and hold the IRT
button [D] to measure the temperature. When releasing the IRT button
[D] the last measured value will remain on the display.
Note: The distance-to-target ratio is 1:1; the thermometer should be
measurement). Press the hold button [E] to exit LOCK-mode.
to °F mode and vice versa.
(see §7).
• Use the mode button [C] to scroll through the available functions. The
current function is flashing (except ε).
MIN The MIN function is not supported.
MAX The MAX function is not supported.
LOCK Press the IRT button [D] to enable LOCK-mode (continuous
°C/°F When °C indication is flashing, press the IRT button [D] to switch
εPress the up [E] and down [D] buttons to set the emissivity
•To switch off the thermometer press the ON/OFF button [F] two times.
Clamp mode
• All data is shown on the probe/clamp LCD [B2].
• Push the clamp trigger [G] to open the clamp [H]. Place the clamp over
the target (e.g. a hot pipe) and read the temperature.
• Press the mode button [C] to switch between °C and °F display.
• Press the hold button [E] to hold the current value on the display. Press
the hold button [E] again to continue measuring.
•To switch off the thermometer press the ON/OFF button [F].
Probe mode
• All data is shown on the probe/clamp LCD [B2].
• Insert the probe [I] into the target and read the temperature.
• Press the mode button [C] to switch between °C and °F display.
• Press the hold button [E] to hold the current value on the display. Press
the hold button [E] again to continue measuring.
•To switch off the thermometer press the ON/OFF button [F].
7. Useful information
Emissivity
Emissivity describes the energy-emitting charact er istics of materials. Most
organic or oxidized surfaces have an emissivity of ±0.95 (default setting).
Measuring shiny or polished surfaces will be inaccurate. Use some masking
tape or paint to compensate, allow sufficient time for the tape or paint to
reach the surface temperature.
Refer to the table for an indication of some emissivity values.
Use this device with original accessories only. Velleman nv cannot
be held responsible in the event of damage or injury resulting from
(incorrect) use of this device.
For more info concerning this product and the latest version of this
manual, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior
notice.
No part of this manual or may be copied, reproduced, translated or reduced
to any electronic medium or otherwise without the prior written consent of
the copyright holder.
Gebruikershandleiding
1. Inleiding
Aan alle ingezetenen van de Europese Unie
Belangrijke milieu-informatie betreffende dit product
brengen. Respecteer de plaatselijke milieuwetgeving.
Hebt u vragen, contacteer dan de plaatselijke autoriteiten
betreffend de verwijdering.
Dank u voor uw aankoop! Lees deze handleiding grondig voor u het toestel
in gebruik neemt. Werd het toestel beschadigd tijdens het tr ansport ,
installeer het dan niet en raadpleeg uw dealer.
2. Veiligheidsinstructies
Dit symbool op het toestel of de verpakking geeft aan dat, als het
na zijn levenscyclus wordt weggeworpen, dit toestel schade kan
toebrengen aan het milieu. Gooi dit toestel (en eventuele
batterijen) niet bij het gewone huishoudelijke afval; het moet bij
een gespecialiseerd bedrijf ter echt komen voor r ecyclage. U moet
dit toestel naar uw verdeler of naar een lokaal recyclagepunt
Houd buiten het bereik van kinderen en onbevoegden.
Bescherm tegen regen, vochtigheid en opspattend e vloeistoff en.
Houd de thermometer nooit te lang en te dicht bij een
warmtebron (bv. kookplaat) om beschadiging te ver mijden.
Raadpleeg de Velleman® service- en kwaliteitsgarantie achteraan deze
handleiding.
• Bescherm de thermometer tegen schokken. Vermijd brut e kr acht
tijdens de bediening.
• Bescherm tegen extreme temperaturen en stof.
• Leer eerst de functies van het toestel kennen voor u het gaat
gebruiken.
• Om veiligheidsredenen mag u geen wijzigingen aanbreng en. Schade
door wijzigingen die de gebruiker heeft aangebracht valt niet onder de
garantie.
• Gebruik het toestel enkel waarvoor het gemaakt is. Bij onoordeelkundig
gebruik vervalt de garantie.
• De garantie geldt niet voor schade door het negeren van bepaalde
richtlijnen in deze handleiding en uw dealer zal de verantwoordelijkheid
afwijzen voor defecten of problemen die hier rechtstreeks ver b and mee
houden.
• Bewaar deze handleiding voor verdere raadp leging.
4. Eigenschappen
• temperatuurweergave in °C of °F
• data hold
• vergrendelfunctie voor continue meting
• aanduiding voor meting buiten bereik
• automatische uitschakeling
• instelbare emissivit eit
• resolutie van 0,1°C (0,1°F)
5. Omschrijving
Raadpleeg de figuur op pagina 2 van deze handleiding.
Druk op de IRT-knop [D] om de thermometer te vergrendelen
functie op te heffen.
°C/°F
Druk, indien de °C-aanduiding knippert, op de IRT-knop [D] om
ε
Stel de emiss iviteit in met [E] en [D] (zie §7 ).
6. Gebruik
• De thermometer heef t 3 meetfunct ies: via IR, de sonde of de bek. De
inschakeling bepaalt de gebr uikte meetfunct ie:
o Druk op IRT [D] om te meten via de IR-sensor [A].
o Druk op ON/OFF [F] om te meten via de bek [H].
o Klap eerst de sonde [I] open en druk op ON/OFF [F] om te meten
via de sonde.
• In hold-functie zal de thermometer na 15 seconden automatisch
uitschakelen, in continue meetfunctie gebeur t dit na ± 20 minuten.
Meting via de IR-sensor
• Alle data verschijnt op de lcd [B1].
• Richt de sensor [A] naar het meetpunt en houd de IRT-knop [D]
ingedrukt. Bij het loslaten van de IRT-knop [D] verschijnt de laatste
meting op de display.
Opmerking: De verhouding afstand-meetpunt bedraagt 1:1. Houd de
thermometer dus zo dicht mogelijk tegen het meetpunt.
• Scroll door de verschillende functies met d e MOD E-knop [C]. De
geselecteerde functie knippert (uitgenomen ε).
(continue meting). Houd de HOLD-knop [E] ingedrukt om de
naar de °F-weer gave te schakelen en omgekeerd.
•Schakel de thermometer uit door tweemaal op ON/OFF [F] te drukken.
Meting via de bek
• Alle data verschijnt op de lcd [B2].
• Druk op de trekker [G] om de bek te openen [H]. Plaats de bek rond
het te meten object (bv. buis) en lees de waarde van de display af.
• Schakel tussen de °C- en °F-weer g ave met de MODE-knop [C].
• Houd de HOLD-knop [E] ingedrukt om de huidige waarde op d e display
vast te houden. Houd de knop opnieuw ingedrukt om verder te gaan.
• Schakel de thermometer uit door de ON/OFF-knop [F] in te drukken.