VEGA MIPT61 User Manual

Operating Instructions
VEGAMIP T61
Emitting unit
Document ID:
36998
Radar

Contents

Contents
1 About this document
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Symbolism used. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 For your safety
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . .
2.4 General safety instructions . . . . . . . . . . . . . . . . . . . .
2.5 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.6 Radio license for Europe. . . . . . . . . . . . . . . . . . . . . .
2.7 Radio license for USA/Canada . . . . . . . . . . . . . . . . .
2.8 Environmental instructions. . . . . . . . . . . . . . . . . . . . .
3 Product description
3.1 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Packaging, transport and storage . . . . . . . . . . . . . . .
3.4 Accessories and replacement parts . . . . . . . . . . . . . .
4 Mounting
4.1 General instructions . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Instructions for installation . . . . . . . . . . . . . . . . . . . . .
4 4 4
5 5 5 5 6 6 6 7
8
8 10 11
13 13
5 Connecting to power supply
5.1 Preparing the connection . . . . . . . . . . . . . . . . . . . . .
5.2 Connection procedure. . . . . . . . . . . . . . . . . . . . . . . .
5.3 Wiring plan, single chamber housing . . . . . . . . . . . . .
6 Setup
6.1 Adjustment elements . . . . . . . . . . . . . . . . . . . . . . . .
7 Maintenance and fault rectication
7.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Remove interferences. . . . . . . . . . . . . . . . . . . . . . . .
7.3 Exchange of the electronics . . . . . . . . . . . . . . . . . . .
7.4 How to proceed in case of repair. . . . . . . . . . . . . . . .
8 Dismounting
8.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 Supplement
9.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 VEGAMIP T61 Emitting unit
14 14 16
17
18 18 18 18
19 19
20 23
36998-EN-120228
Contents
Safety instructions for Ex areas
Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.
Editing status: 2012-02-14
36998-EN-120228
VEGAMIP T61 Emitting unit 3

1 About this document

1 About this document

1.1 Function

This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.

1.2 Target group

This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
This arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
4 VEGAMIP T61 Emitting unit
36998-EN-120228

2 For your safety

2 For your safety

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.
During work on and with the device the required personal protective equipment must always be worn.

2.2 Appropriate use

The VEGAMIP 61 is a sensor for level detection.
You can nd detailed information on the application range in chapter
"Product description".
Operational reliability is ensured only if the instrument is properly used according to the specications in the operating instructions manual as well as possible supplementary instructions.

2.3 Warning about misuse

Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overll or damage to system components through incorrect mounting or adjustment.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing regulations and guidelines. The instrument must only be operated in a technically awless and reliable condition. The operator is responsible for the trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the compliance of the necessary occupational safety measures with the current valid rules and regulations and also take note of new regulations.
The safety instructions in this operating instructions manual, the national installation standards as well as the valid safety regulations and accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modications are explicitly forbidden.
The safety approval markings and safety tips on the device must also be observed.
36998-EN-120228
VEGAMIP T61 Emitting unit 5
2 For your safety
The emitting frequencies of the sensors depend on the model, but are
all in the K band range. The low transmitting power lies far below the internationally permitted limit value. When the instrument is used correctly, it presents no danger to human health. It may be operated without restriction outside of closed vessels.
2.5 CE conformity
The device fullls the legal requirements of the applicable EC guidelines. By axing the CE marking, VEGA conrms successful testing of the product.
Only with class A instruments:
The device is a class A instrument designed for use in an industrial environment. When used in a dierent environment, e.g., in a living area, the electromagnetic compatibility must be ensured by the user. If necessary, suitable screening measures against conducted and emitted disturbances must be taken.
You can nd the conformity certicate in the download section under www.vega.com.

2.6 Radio license for Europe

The instrument is approved according to EN 300440-1 V1.5.1 (2009-
03) and EN 300440-2 V1.531 (2009-03) and can be used without radio
limitations.

2.7 Radio license for USA/Canada

Operation is only permitted if the following two conditions are fullled:
l The instrument must not emit interference radiation l The instrument must operate without being aected by incoming
interference radiation, including such that may trigger unwanted operating conditions.
The instrument is in conformity with the following regulations:
FCC: Part 15 of the FCC regulations
IC: RSS-210 Issue 7, RSS-GEN Issue 2 and RSS-102 Issue 4 of the IC
regulations.
Conversions or modications of the instrument not expressly approved by the manufacturer will lead to loss of the approval.
Before use, make sure that the respective approval numbers are stated on the type label (see chapter "Conguration").
6 VEGAMIP T61 Emitting unit
36998-EN-120228
2 For your safety

2.8 Environmental instructions

Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection.
The environment management system is certied according to DIN EN ISO 14001.
Please help us full this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage" l Chapter "Disposal"
36998-EN-120228
VEGAMIP T61 Emitting unit 7

3 Product description

3 Product description

3.1 Structure

Type label
Serial number
Scope of delivery
The type label contains the most important data for identication and use of the instrument:
l Article number l Serial number l Technical data l Article numbers, documentation
With the serial number, you can access the delivery data of the instrument via
www.vega.com, "VEGA Tools" and "serial number search". In addition to the type label outside, you can also nd the serial number on the inside of the instrument.
With the serial number of the instrument on the type label you have access to the following data on our homepage:
l Article number of the instrument (HTML) l Delivery date (HTML) l Order-specic instrument features (HTML) l Operating instructions at the time of shipment (PDF) l Order-specic sensor data for an electronics exchange (XML) l Test certicate "Measuring Accuracy" (PDF)
www.vega.com, "Service" "VEGA Tools" and "serial number
Go to
search".
The scope of delivery typically includes the following parts.
l Point level sensor VEGAMIP T61 (emitting unit) l Documentation
- this operating instructions manual
- Supplementary instructions manual "Plug connector for level
sensors" (optional)
- Ex-specic "Safety instructions" (with Ex versions)
- if necessary, further certicates
l The corresponding receiving unit VEGAMIP R61 is described in a
separate operating instructions manual.

3.2 Principle of operation

Application area
8 VEGAMIP T61 • Emitting unit
VEGAMIP 61 is a microwave barrier for level detection.
It is designed for industrial use in all areas of process technology and
can be used in bulk solids and liquids.
36998-EN-120228
33
5
4
5
21
3 Product description
Typical applications are overll and dry run protection. With an
operating distance of 100 m, VEGAMIP 61 can be used, for example, in bulk solids silos with large diameters. Thanks to its simple and rugged measuring system, VEGAMIP 61 is virtually unaected by the process and the chemical and physical properties of the medium.
VEGAMIP 61 can also be used for detection of vehicles and ships or for material recognition on conveyor belts.
It works even under extremely dicult conditions: dierent grain sizes, contamination, extreme lling noise, high temperatures, strong dust generation and abrasive products are all no problem for the instrument.
The VEGAMIP 61 consists of the following components.
Fig. 1: VEGAMIP 61 with plastic housing
1 Emitting unit VEGAMIP T61 2 Receiving unit VEGAMIP R61 with control electronics 3 Housing cover 4 Housing with control electronics 5 Process tting
36998-EN-120228
VEGAMIP T61 Emitting unit 9