VEGA MIPT61 User Manual

Operating Instructions
VEGAMIP T61
Emitting unit
Document ID:
36998
Radar

Contents

Contents
1 About this document
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Symbolism used. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 For your safety
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . .
2.4 General safety instructions . . . . . . . . . . . . . . . . . . . .
2.5 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.6 Radio license for Europe. . . . . . . . . . . . . . . . . . . . . .
2.7 Radio license for USA/Canada . . . . . . . . . . . . . . . . .
2.8 Environmental instructions. . . . . . . . . . . . . . . . . . . . .
3 Product description
3.1 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Packaging, transport and storage . . . . . . . . . . . . . . .
3.4 Accessories and replacement parts . . . . . . . . . . . . . .
4 Mounting
4.1 General instructions . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Instructions for installation . . . . . . . . . . . . . . . . . . . . .
4 4 4
5 5 5 5 6 6 6 7
8
8 10 11
13 13
5 Connecting to power supply
5.1 Preparing the connection . . . . . . . . . . . . . . . . . . . . .
5.2 Connection procedure. . . . . . . . . . . . . . . . . . . . . . . .
5.3 Wiring plan, single chamber housing . . . . . . . . . . . . .
6 Setup
6.1 Adjustment elements . . . . . . . . . . . . . . . . . . . . . . . .
7 Maintenance and fault rectication
7.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Remove interferences. . . . . . . . . . . . . . . . . . . . . . . .
7.3 Exchange of the electronics . . . . . . . . . . . . . . . . . . .
7.4 How to proceed in case of repair. . . . . . . . . . . . . . . .
8 Dismounting
8.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 Supplement
9.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 VEGAMIP T61 Emitting unit
14 14 16
17
18 18 18 18
19 19
20 23
36998-EN-120228
Contents
Safety instructions for Ex areas
Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.
Editing status: 2012-02-14
36998-EN-120228
VEGAMIP T61 Emitting unit 3

1 About this document

1 About this document

1.1 Function

This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.

1.2 Target group

This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
This arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
4 VEGAMIP T61 Emitting unit
36998-EN-120228

2 For your safety

2 For your safety

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.
During work on and with the device the required personal protective equipment must always be worn.

2.2 Appropriate use

The VEGAMIP 61 is a sensor for level detection.
You can nd detailed information on the application range in chapter
"Product description".
Operational reliability is ensured only if the instrument is properly used according to the specications in the operating instructions manual as well as possible supplementary instructions.

2.3 Warning about misuse

Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overll or damage to system components through incorrect mounting or adjustment.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing regulations and guidelines. The instrument must only be operated in a technically awless and reliable condition. The operator is responsible for the trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the compliance of the necessary occupational safety measures with the current valid rules and regulations and also take note of new regulations.
The safety instructions in this operating instructions manual, the national installation standards as well as the valid safety regulations and accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modications are explicitly forbidden.
The safety approval markings and safety tips on the device must also be observed.
36998-EN-120228
VEGAMIP T61 Emitting unit 5
2 For your safety
The emitting frequencies of the sensors depend on the model, but are
all in the K band range. The low transmitting power lies far below the internationally permitted limit value. When the instrument is used correctly, it presents no danger to human health. It may be operated without restriction outside of closed vessels.
2.5 CE conformity
The device fullls the legal requirements of the applicable EC guidelines. By axing the CE marking, VEGA conrms successful testing of the product.
Only with class A instruments:
The device is a class A instrument designed for use in an industrial environment. When used in a dierent environment, e.g., in a living area, the electromagnetic compatibility must be ensured by the user. If necessary, suitable screening measures against conducted and emitted disturbances must be taken.
You can nd the conformity certicate in the download section under www.vega.com.

2.6 Radio license for Europe

The instrument is approved according to EN 300440-1 V1.5.1 (2009-
03) and EN 300440-2 V1.531 (2009-03) and can be used without radio
limitations.

2.7 Radio license for USA/Canada

Operation is only permitted if the following two conditions are fullled:
l The instrument must not emit interference radiation l The instrument must operate without being aected by incoming
interference radiation, including such that may trigger unwanted operating conditions.
The instrument is in conformity with the following regulations:
FCC: Part 15 of the FCC regulations
IC: RSS-210 Issue 7, RSS-GEN Issue 2 and RSS-102 Issue 4 of the IC
regulations.
Conversions or modications of the instrument not expressly approved by the manufacturer will lead to loss of the approval.
Before use, make sure that the respective approval numbers are stated on the type label (see chapter "Conguration").
6 VEGAMIP T61 Emitting unit
36998-EN-120228
2 For your safety

2.8 Environmental instructions

Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection.
The environment management system is certied according to DIN EN ISO 14001.
Please help us full this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage" l Chapter "Disposal"
36998-EN-120228
VEGAMIP T61 Emitting unit 7

3 Product description

3 Product description

3.1 Structure

Type label
Serial number
Scope of delivery
The type label contains the most important data for identication and use of the instrument:
l Article number l Serial number l Technical data l Article numbers, documentation
With the serial number, you can access the delivery data of the instrument via
www.vega.com, "VEGA Tools" and "serial number search". In addition to the type label outside, you can also nd the serial number on the inside of the instrument.
With the serial number of the instrument on the type label you have access to the following data on our homepage:
l Article number of the instrument (HTML) l Delivery date (HTML) l Order-specic instrument features (HTML) l Operating instructions at the time of shipment (PDF) l Order-specic sensor data for an electronics exchange (XML) l Test certicate "Measuring Accuracy" (PDF)
www.vega.com, "Service" "VEGA Tools" and "serial number
Go to
search".
The scope of delivery typically includes the following parts.
l Point level sensor VEGAMIP T61 (emitting unit) l Documentation
- this operating instructions manual
- Supplementary instructions manual "Plug connector for level
sensors" (optional)
- Ex-specic "Safety instructions" (with Ex versions)
- if necessary, further certicates
l The corresponding receiving unit VEGAMIP R61 is described in a
separate operating instructions manual.

3.2 Principle of operation

Application area
8 VEGAMIP T61 • Emitting unit
VEGAMIP 61 is a microwave barrier for level detection.
It is designed for industrial use in all areas of process technology and
can be used in bulk solids and liquids.
36998-EN-120228
33
5
4
5
21
3 Product description
Typical applications are overll and dry run protection. With an
operating distance of 100 m, VEGAMIP 61 can be used, for example, in bulk solids silos with large diameters. Thanks to its simple and rugged measuring system, VEGAMIP 61 is virtually unaected by the process and the chemical and physical properties of the medium.
VEGAMIP 61 can also be used for detection of vehicles and ships or for material recognition on conveyor belts.
It works even under extremely dicult conditions: dierent grain sizes, contamination, extreme lling noise, high temperatures, strong dust generation and abrasive products are all no problem for the instrument.
The VEGAMIP 61 consists of the following components.
Fig. 1: VEGAMIP 61 with plastic housing
1 Emitting unit VEGAMIP T61 2 Receiving unit VEGAMIP R61 with control electronics 3 Housing cover 4 Housing with control electronics 5 Process tting
36998-EN-120228
VEGAMIP T61 Emitting unit 9
1 2
3 5
4
3 Product description
Several antenna versions are available for dierent applications.
Fig. 2: Antenna versions
1 Threaded version - internal horn antenna with PTFE cover 2 Plastic encapsulated antenna with PP cover 3 Horn antenna/316L 4 VEGAMIP 61 with angled antenna extension 5 Encapsulated horn antenna with PTFE cover
Functional principle
The emitting unit transmits a focused microwave signal via horn antenna to the receiving unit on the opposite side. If there is medium between emitting and receiving unit, the signal is damped. This change is detected by the built-in electronics module and converted into a switching command.

3.3 Packaging, transport and storage

Packaging
Transport
Transport inspection
10 VEGAMIP T61 • Emitting unit
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environment­friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device.
The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with.
36998-EN-120228
3 Product description
Storage
Storage and transport
temperature
Protective cover
Flanges
Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside.
Unless otherwise indicated, the packages must be stored only under the following conditions:
l Not in the open l Dry and dust free l Not exposed to corrosive media l Protected against solar radiation l Avoiding mechanical shock and vibration
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
l Relative humidity 20 85 %

3.4 Accessories and replacement parts

The protective cover protects the sensor housing against soiling and intense heat from solar radiation.
You will nd additional information in the supplementary instructions manual "Protective cover" (Document-ID 34296).
Flanges are available in dierent versions according to the following standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-1984,
GOST 12821-80.
You can nd additional information in the supplementary instructions manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID
31088).
Electronics module
The electronics module VEGAMIP T61 is a replacement part for microwave barriers of VEGAMIP series 60.
You will nd additional information in the following operating instructions manual:
l "Electronics module VEGAMIP T61 (emitting unit)" (Document-ID
36429)
36998-EN-120228
VEGAMIP T61 Emitting unit 11
3 Product description
Mounting adapter
With high process temperatures exceeding 80 °C, you have to use a mounting adapter for the emitting and the receiving unit. The mounting adapter can only be used with the threaded version (internal horn antenna with PTFE cover).
Fig. 3: VEGAMIP 61 with high temperature mounting adapter
12 VEGAMIP T61 Emitting unit
36998-EN-120228

4 Mounting

4.1 General instructions

4 Mounting
Screwing in
Suitability for the pro-
cess conditions
Moisture
Installation
With instruments with threaded process tting, suitable tools must be applied for tightening the hexagon.
Warning:
The housing must not be used to screw the instrument in! Applying tightening force can damage internal parts of the housing.
Make sure that all parts of the instrument exposed to the process, in particular the active measuring component, process seal and process tting, are suitable for the existing process conditions. These include above all the process pressure, process temperature as well as the chemical properties of the medium.
You can nd the specications in chapter "Technical data" and on the type label.
Use the recommended cables (see chapter "Connecting to power supply") and tighten the cable gland.
You can give your instrument additional protection against moisture penetration by leading the connection cable downward in front of the cable entry. Rain and condensation water can thus drain off. This applies mainly to outdoor mounting as well as installation in areas where high humidity is expected (e.g. through cleaning processes) or on cooled or heated vessels.

4.2 Instructions for installation

You can nd the mounting instructions for VEGAMIP 61 in the operating instructions of the receiving unit.
36998-EN-120228
VEGAMIP T61 Emitting unit 13

5 Connecting to power supply

5 Connecting to power supply

5.1 Preparing the connection

Safety instructions
Voltage supply
Connection cable
Connection technology
Always keep in mind the following safety instructions:
l Connect only in the complete absence of line voltage l If voltage surges are expected, install overvoltage arresters
Connect the operating voltage according to the connection diagrams. The electronics module is designed in protection class I. To maintain
this protection class, it is absolutely necessary that the earth conductor be connected to the inner earth conductor terminal. Keep the general installation regulations in mind. Take note of the corresponding installation regulations for hazardous areas with Ex applications.
The data for power supply are specied in chapter "Technical data".
The instrument is connected with standard three-wire cable without
screen. If electromagnetic interference is expected which is above the test values of EN 61326 for industrial areas, screened cable should be used.
Use cable with round cross-section. A cable outer diameter of 5 … 9 mm (0.2 0.35 in) ensures the seal eect of the cable gland. If you are
using cable with a dierent diameter or cross-section, exchange the seal or use a suitable cable gland.
Cover all housing openings conforming to standard according to EN 60079-1.

5.2 Connection procedure

The voltage supply and signal output are connected via the spring­loaded terminals in the housing.
Connection procedure
14 VEGAMIP T61 • Emitting unit
Proceed as follows:
1 Unscrew the housing cover 2 Loosen compression nut of the cable entry 3 Remove approx. 10 cm (4 in) of the cable mantle, strip approx.
1 cm (0.4 in) of insulation from the ends of the individual wires
36998-EN-120228
5 Connecting to power supply
4 Insert the cable into the sensor through the cable entry
Fig. 4: Connection steps 4 and 5
5 Insert the wire ends into the terminals according to the wiring plan
Information:
Solid cores as well as exible cores with cable end sleeves are inserted directly into the terminal openings. In case of exible cores without end sleeves, press the terminal with a small screwdriver; the terminal opening is freed. When the screwdriver is released, the terminal closes again.
6 Check the hold of the wires in the terminals by lightly pulling on
them
7 Connect the screen to the internal ground terminal, connect the
outer ground terminal to potential equalisation
8 Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable
9 Screw the housing cover back on
The electrical connection is nished.
Information:
The terminal block is pluggable and can be removed from the electronics. To do this, lift the terminal block with a small screwdriver and pull it out. When inserting the terminal block again, you should hear it snap in.
36998-EN-120228
VEGAMIP T61 Emitting unit 15
1
5 Connecting to power supply

5.3 Wiring plan, single chamber housing

Wiring plan
We recommend connecting VEGAMIP 61 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe condition).
Fig. 5: Wiring plan emitting unit - VEGAMIP 61 (transmitter)
1 Voltage supply
16 VEGAMIP T61 Emitting unit
36998-EN-120228

6 Setup

6.1 Adjustment elements

You can nd the adjustment of VEGAMIP 61 in the operating instructions of the VEGAMIP R61 (receiving unit).
6 Setup
36998-EN-120228
VEGAMIP T61 Emitting unit 17
7 Maintenance and fault rectication
7 Maintenance and fault rectication

7.1 Maintenance

If the device is used correctly, no maintenance is required in normal operation.

7.2 Remove interferences

Reaction when malfunc-
tions occur
Fault rectication
The operator of the system is responsible for taking suitable measures to rectify faults.
You can nd information on fault rectication in the operating instructions manual of the receiving unit.

7.3 Exchange of the electronics

If the electronics module is defective, it can be replaced by the user.
In Ex applications only an electronics module with respective Ex
approval may be used.
You nd all information to the electronics exchange in the operating instructions of the new electronics module.

7.4 How to proceed in case of repair

If a repair is necessary, please proceed as follows:
You can download a return form (23 KB) from our homepage at
vega.com under: "Downloads - Forms and certicates - Repair form".
By doing this you help us carry out the repair quickly and without having to call back for needed information.
l Print and ll out one form per instrument l Clean the instrument and pack it damage-proof l Attach the completed form and, if need be, also a safety data
sheet outside on the packaging
l Please ask the agency serving you for the address of your return
shipment. You can nd the competent agency on our website www.vega.com.
www.
18 VEGAMIP T61 Emitting unit
36998-EN-120228

8 Dismounting

8 Dismounting

8.1 Dismounting steps

Warning:
Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vessel, high temperatures, corrosive or toxic products etc.
Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order.

8.2 Disposal

The instrument consists of materials which can be recycled by specialised recycling companies. We use recyclable materials and have designed the electronics to be easily separable.
Correct disposal avoids negative eects on humans and the environ­ment and ensures recycling of useful raw materials.
Materials: see chapter "Technical data"
If you have no way to dispose of the old instrument properly, please
contact us concerning return and disposal.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive 2002/96/EG and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. These may be used only for privately used products according to the WEEE directive.
36998-EN-120228
VEGAMIP T61 Emitting unit 19

9 Supplement

9 Supplement

9.1 Technical data

General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
- Process tting - thread 316L
- Process tting - ange 316L
Antenna Instrument seal Cover or wetted
Threaded version - internal horn antenna with PTFE cover
Plastic encapsulated antenna with PP cover - PP
Horn antenna/316L FKM (SHS FDM 70C3 GLT)
Encapsulated horn antenna with PTFE cover - PTFE
Mounting adapter (option) Graphite Ceramic Al
FKM (A+P 70.16.-06) Process seal: Klingersil C-4400
FFKM (Kalrez 6375) Process seal: Klingersil C-4400
materials
PTFE 316L
PTFE
316L
2O3
316L
Materials, non-wetted parts
- Plastic housing plastic PBT (Polyester)
- Aluminium die-casting housing Aluminium die-casting AlSi10Mg, powder-coated -
basis: Polyester
- Stainless steel housing - precision cast-
316L
ing
- Stainless steel housing, electropolished 316L
- Seal between housing and housing
cover
NBR (stainless steel housing, precision casting), silicone (aluminium/plastic housing; stainless steel housng, electropolished)
- Ground terminal 316L
- Mounting adapter (option) 316L
Sensor length See chapter "Dimensions"
Instrument weight (depending on process
0.8 … 4 kg (0.18 … 8.82 lbs)
tting)
Process fittings
- Pipe thread, cylindrical (ISO 228 T1) G1½ A
- American pipe thread, tapered 1½ NPT
- Flanges DIN from DN 50, ANSI from 2"
- Mounting adapter G2 A or 2 NPT
36998-EN-120228
20 VEGAMIP T61 Emitting unit
9 Supplement
Frequency range K band, 24.085 GHz (ISM band) Measuring range 0.1 … 100 m (0.33 328 ft)
Beam angle
- Threaded version - internal horn antenna
1)
20°
(PTFE cover)
- Plastic encapsulated antenna with PP
10°
cover
- Horn antenna (316L) - ø 40 mm (1.575 in) 22°
- Horn antenna (316L) - ø 48 mm (1.89 in) 18°
- Encapsulated antenna with PTFE cover -
18°
Flange DN 50, ANSI 2"
- Encapsulated antenna with PTFE cover -
10°
Flange DN 80 DN 150, ANSI 3" 6"
Ambient conditions
Ambient, storage and transport temperature -40 +80 °C (-40 +176 °F)
Process conditions
Measured variable Limit level of bulk solids and liquids
Process pressure
- VEGAMIP 61, threaded version - internal
2)
-1 4 bar/-100 400 kPa (-14.5 58 psig)
horn antenna with PTFE cover
- VEGAMIP 61, plastic encapsulated an-
-1 2 bar/-100 200 kPa (-14.5 29 psig)
tenna with PP cover
- VEGAMIP 61, horn antenna/316L -1 40 bar/-100 4000 kPa (-14.5 580 psig)
- VEGAMIP 61, encapsulated horn anten-
-1 16 bar/-100 1600 kPa (-14.5 232 psig)
na with PTFE cover
- VEGAMIP 61 with mounting adapter unpressurized (IP 67)
Process temperature (thread or ange tem-
perature)
- VEGAMIP 61, threaded version - internal
-40 +80 °C (-40 +176 °F)
horn antenna with PTFE cover
- VEGAMIP 61, plastic encapsulated an-
-40 +80 °C (-40 +176 °F)
tenna with PP cover
- VEGAMIP 61, horn antenna/316L - seal:
-40 +130 °C (-40 +266 °F)
FKM (SHS FDM 70C3 GLT)
- VEGAMIP 61, horn antenna/316L - seal:
-20 +130 °C (-4 +266 °F)
FFKM (Kalrez 6375)
1)
Outside the specied beam angle, the energy of the radar signal has a level of -3 dB (50 %)
2)
Note max. pressure of the process tting
36998-EN-120228
VEGAMIP T61 Emitting unit 21
9 Supplement
- VEGAMIP 61, encapsulated horn anten-
-40 +200 °C (-40 +392 °F)
na with PTFE cover
- VEGAMIP 61 with mounting adapter
-40 … +250 °C (-40 … +482 °F)
150 mm (optional)
- VEGAMIP 61 with mounting adapter
-40 … +450 °C (-40 … +842 °F)
300 mm (optional)
Performance data
Emitted power < 3 mW Max. power density in a distance of 1 m < 1 µW/cm²
Electromechanical data
Cable entry/plug (dependent on the version)
- Single chamber housing l 1 x cable entry M20 x 1.5 (cable: ø 5 9 mm), 1 x blind stopper M20 x 1.5; attached 1 x cable
entry M20 x 1.5
or:
l 1 x cable entry ½ NPT, 1 x blind stopper ½ NPT,
1 x cable entry ½ NPT
or:
l 1 x plug M12 x 1; 1 x blind stopper M20 x 1.5
Spring-loaded terminals for wire cross-section up to 1.5 mm² (AWG 16)
Voltage supply
Operating voltage 20 … 253 V AC, 50/60 Hz, 20 72 V DC (at
U >60 V DC, the ambient temperature can be max. 50 °C/122 °F)
Power consumption 2 VA (AC), approx. 0.8 W (DC)
Electrical protective measures
Protection rating IP 66/IP 67
Overvoltage category III
Protection class I
Approvals
Instruments with approvals can have dierent technical data depending on the version.
That's why the associated approval documents have to be noted with these instruments. They are
part of the delivery or can be downloaded under
www.vega.com via "VEGA Tools" and "serial
number search" as well as via "Downloads" and "Approvals".
22 VEGAMIP T61 Emitting unit
36998-EN-120228

9.2 Dimensions

~ 69 mm (2 23/32")
ø 77 mm
(3
1
/32")
112 mm (4
13
/
32
")
M20x1,5/ ½ NPT
~ 69 mm (2 23/32")
ø 77 mm
(3
1
/32")
117 mm (4
39
/
64
")
M20x1,5/ ½ NPT
~ 116 mm (4 9/16")
ø 84 mm (3
5
/16")
116 mm (4
9
/
16
")
M20x1,5M20x1,5/
½ NPT
~ 59 mm (2 21/64")
ø 80 mm
(3
5
/32")
112 mm (4
13
/
32
")
M20x1,5/ ½ NPT
1 3 4
2
22mm
(0.87")
83mm (3.27")
SW 46 mm
(1.42")
SW 46 mm
(1.42")
SW 60 mm
(1.42")
G1½ A
1½ NPT
83mm (3.27")
1 2
VEGAMIP 61 - housing versions
Fig. 6: Housing versions
1 Plastic housing 2 Stainless steel housing, electropolished 3 Stainless steel housing - precision casting 4 Aluminium housing
VEGAMIP 61
9 Supplement
Fig. 7: VEGAMIP 61 - threaded version
1 Threaded version - internal horn antenna with PTFE cover - G1½ A 2 Threaded version - internal horn antenna with PTFE cover - 1½ NPT
36998-EN-120228
VEGAMIP T61 Emitting unit 23
2
1
4
3
15 mm
(0.59")
98 mm
(3.86")
170 mm / 300 mm
(6.69") / (11.81")
19 mm
(0.75")
ø 75 mm
(2.95")
ø 115 mm
(4.53")
99,5 mm (3.92")
ø 44 mm
(1.73")
9 Supplement
VEGAMIP 61
Fig. 8: VEGAMIP 61, encapsulated antennas
1 Encapsulated horn antenna with PTFE cover - ange version 2 Plastic encapsulated antenna with PP cover 3 Mounting strap 4 Adapter ange
24 VEGAMIP T61 Emitting unit
36998-EN-120228
VEGAMIP 61
mm
inch
38 mm (1.50")
22 mm (0.87")
SW 46 mm
(1.81")
8.50"
16.93"
3.94" ø1.58" ø1.89" ø2.95" ø3.74"
4.72"
xy
100 ø40
120 ø48
216 ø75
430 ø95
1½"
2"
3"
4"
xy
1½"
2"
3"
4"
x
y
G1½A / 1½ NPT
1
24mm (0.95")
x
61 mm
(2.4")
G2 A
Fig. 9: VEGAMIP 61, horn antenna/316L
VEGAMIP 61 - Mounting adapter (-40 +450 °C)
9 Supplement
Fig. 10: Mounting adapter with ceramic cover for VEGAMIP 61 - threaded version G2 A with PTFE cover (also with 2 NPT thread)
x 150 mm (5.9 in) or 300 mm (11.8 in)
36998-EN-120228
VEGAMIP T61 Emitting unit 25
9 Supplement

9.3 Industrial property rights

VEGA product lines are global protected by industrial property rights. Further information see http://www.vega.com.
Only in U.S.A.: Further information see patent label at the sensor housing.
VEGA Produktfamilien sind weltweit geschützt durch gewerbliche Schutzrechte.
Nähere Informationen unter http://www.vega.com.
Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellectuelle. Pour plus d'informations, on pourra se référer au site http://www.vega.com.
VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad industrial. Para mayor información revise la pagina web http://www.vega.com.
Линии продукции фирмы ВЕГА защищаются по всему миру правами на интеллектуальную собственность. Дальнейшую информацию смотрите на сайте http://www.vega.com.
VEGA 站<http://www.vega.com>

9.4 Trademark

All the brands as well as trade and company names used are property of their lawful proprietor/originator.
26 VEGAMIP T61 Emitting unit
36998-EN-120228
INDEX
Index
A
Accessory
- Flanges 11
- Protective cover 11
Application area 8
C
Cable 14 Cable screening 14
E
Electronics module 11, 18 Emitting unit 9, 16 Encapsulated antennas 24
F
Fault rectication 18 Functional principle 10
H
Horn antenna 25
M
Moisture 13 Mounting adapter 12, 25
O
Operation 17
W
Wiring plan 16
P
Packaging 10 Potential equalisation 14
R
Receiving unit 9 Repair 18
S
Scope of delivery 8 Shielding 14 Storage 11
T
Threaded version 23 Type label 8
36998-EN-120228
VEGAMIP T61 Emitting unit 27
VEGA Grieshaber KG
ISO 9001
Am Hohenstein 113 77761 Schiltach
Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com
www.vega.com
Printing date:
All statements concerning scope of delivery, application,
practical use and operating conditions of the sensors and
processing systems correspond to the information avail-
able at the time of printing.
© VEGA Grieshaber KG, Schiltach/Germany 2012
Subject to change without prior notice 36998-EN-120228
Loading...