VEGA MIP60 User Manual

Ope
rating Instructions
Electronics module
VEGAMI VEGAMIP series 60 - receiving unit
P series 60 - emitting unit
Document ID:
37349
adar

Contents

Conten
1 About this document
2 For your safety
3 Product description
4 Mounting
5 Setup
6 Maintain
7 Dismounting
ts
1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
1.3 Symbolism used . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Environmental instructions. . . . . . . . . . . . . . . . . . . . .
3.1 Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Packaging, transport and storage . . . . . . . . . . . . . . .
4.1 Instructions for installation . . . . . . . . . . . . . . . . . . . . .
4.2 Mounting preparations . . . . . . . . . . . . . . . . . . . . . ..
4.3 Mounting steps. . . . . . . . . . . . . . . . . . . . . . . . . . . ..
5.1 Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 How to proceed in case of repair. . . . . . . . . . . . . . . .
7.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 3 3
4 4 4
5 5 5
7 7 7
10
11
12 12
8 Supplement
8.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety instructions for Ex areas
Ple
ase note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.
2 E
13
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
out this document
1 Ab
1 Abou
t this document

1.1 Function

This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.

1.2 Target group

This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Inform
ation, tip, note
This symbol indicates helpful additional information.
Cauti
on: If this warning is ignored, faults or malfunctions can
result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
applications
Ex
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
Th
is arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
Battery
This symbol indicates special information about the disposal of batteries and accumulators.
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit 3
disposal
2 For
your safety
or your safety
2 F

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.
During work on and with the device the required personal protective equipment must always be worn.

2.2 Appropriate use

The components such as electronics module, accumulator insert, emitting electronics, housing or process components described in this manual are replacement components for existing sensors.

2.3 Environmental instructions

Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection.
The environment management system is certied according to DIN EN ISO 14001.
Please help us full this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage" l Chapter "Disposal"
4 E
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
3 Produc
t description
Sco
pe of delivery
Application area
Packaging
Transport
3 Produc
t description
3.1 Conguration
The scope of delivery encompasses:
l Electronics module for emitting unit VEGAMIP series 60
(MP60EE.T**) or electronics module for receiving unit VEGAMIP series 60 (MP60EE.R**)
l Documentation
- this operating instructions manual

3.2 Principle of operation

The electronics module MP60 is suitable as a replacement for the electronics of microwave barrier VEGAMIP series 60.

3.3 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environment­friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device.
Transport inspection
Storage
Stora
ge and transport
temp
erature
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit 5
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside.
Unless otherwise indicated, the packages must be stored only under the following conditions:
l Not in the open l Dry and dust free l Not exposed to corrosive media l Protected against solar radiation l Avoiding mechanical shock and vibration
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
Loading...