ase note the Ex-specific safety information for installation and
operation in Ex areas. These safety instructions are part of the
operating instructions manual and come with the Ex-approved
instruments.
2E
13
37349-EN-121205
lectronics module • VEGAMIP series 60 - receiving unit
Page 3
out this document
1 Ab
1 Abou
t this document
1.1 Function
This operating instructions manual provides all the information you
need for mounting, connection and setup as well as important
instructions for maintenance and fault rectification. Please read this
information before putting the instrument into operation and keep this
manual accessible in the immediate vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained qualified
personnel. The contents of this manual should be made available to
these personnel and put into practice by them.
1.3 Symbolism used
Inform
ation, tip, note
This symbol indicates helpful additional information.
Cauti
on: If this warning is ignored, faults or malfunctions can
result.
Warning: If this warning is ignored, injury to persons and/or serious
damage to the instrument can result.
Danger: If this warning is ignored, serious injury to persons and/or
destruction of the instrument can result.
applications
Ex
This symbol indicates special instructions for Ex applications.
lList
The dot set in front indicates a list with no implied sequence.
àAction
Th
is arrow indicates a single action.
1Sequence
Numbers set in front indicate successive steps in a procedure.
Battery
This symbol indicates special information about the disposal of
batteries and accumulators.
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit3
disposal
Page 4
2 For
your safety
or your safety
2 F
2.1 Authorised personnel
All operations described in this operating instructions manual must be
carried out only by trained specialist personnel authorised by the plant
operator.
During work on and with the device the required personal protective
equipment must always be worn.
2.2 Appropriate use
The components such as electronics module, accumulator insert,
emitting electronics, housing or process components described in this
manual are replacement components for existing sensors.
2.3 Environmental instructions
Protection of the environment is one of our most important duties. That
is why we have introduced an environment management system with
the goal of continuously improving company environmental protection.
The environment management system is certified according to
DIN EN ISO 14001.
Please help us fulfil this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage"
l Chapter "Disposal"
4E
37349-EN-121205
lectronics module • VEGAMIP series 60 - receiving unit
Page 5
3 Produc
t description
Sco
pe of delivery
Application area
Packaging
Transport
3 Produc
t description
3.1 Configuration
The scope of delivery encompasses:
l Electronics module for emitting unit VEGAMIP series 60
(MP60EE.T**) or electronics module for receiving unit VEGAMIP
series 60 (MP60EE.R**)
l Documentation
- this operating instructions manual
3.2 Principle of operation
The electronics module MP60 is suitable as a replacement for the
electronics of microwave barrier VEGAMIP series 60.
3.3 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
according to DIN EN 24180.
The packaging of standard instruments consists of environmentfriendly, recyclable cardboard. For special versions, PE foam or PE foil
is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out under consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
Transport inspection
Storage
Stora
ge and transport
temp
erature
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit5
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or
concealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
l Not in the open
l Dry and dust free
l Not exposed to corrosive media
l Protected against solar radiation
l Avoiding mechanical shock and vibration
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
Page 6
3 Produc
t description
l Rela
tive humidity 20 … 85 %
6E
37349-EN-121205
lectronics module • VEGAMIP series 60 - receiving unit
Page 7
2
1
4 M
ounting
Electro
emittin
T**
nics module -
g unit MP60EE.
4 Moun
ting
4.1 Instructions for installation
If the electronics module is defective, it can be replaced by the user.
In Ex
applications only one instrument and one electronics module with
respective Ex approval may be used.
4.2 Mounting preparations
Keep in mind that the emitting and receiving unit require special
electronics modules.
l Emitting unit - electronics module MP60EE.T**
l Receiving unit - electronics module MP60EE.R**
4.3 Mounting steps
To exchange the electronics module, proceed as follows:
1 Switch off power supply
2 Unscrew the housing cover
3 Lift the terminal block with a small screwdriver and pull it out.
4 Loosen the two screws with a screw driver (Torx size T10 or slot 4)
Fig. 1: Loosening
1Electronics module
2Screws (2 pcs.)
5 Pull out the old electronics module
6 Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old
electronics module. This applies particularly to instruments used in
hazardous areas.
7 Insert the electronics module carefully. Make sure that the plug is
in the correct position.
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit7
the holding screws
Page 8
2
1
4 M
ounting
tion:
Informa
Make sure that the housing is not rotated during the electronics
exchange. Otherwise the plug may be in a different position later.
8 Screw in the two holding screws and tighten them
9 Insert the terminal block again. You must hear it snap in.
10 Screw the housing cover back on
The electronics exchange is now finished.
As
a rule, an exchange of electronics must be documented internally
when Ex applications are involved.
nics module - re-
Electro
ceiving
unit MP60EE.R**
To exchange the electronics module, proceed as follows:
1 Switch off power supply
2 Unscrew the housing cover
3 Lift the terminal blocks with a small screwdriver and pull them out.
4 Loosen the two screws with a screw driver (Torx size T10 or slot 4)
Fig. 2: Loosening
1Electronics module
2Screws (2 pcs.)
the holding screws
5 Pull out the old electronics module
6 Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old
electronics module. This applies particularly to instruments used in
hazardous areas.
7 Insert the electronics module carefully. Make sure that the plug is
in the correct position.
Informa
tion:
Make sure that the housing is not rotated during the electronics
exchange. Otherwise the plug may be in a different position later.
8 Screw in the two holding screws and tighten them
9 Insert the terminal blocks again. You must hear them snap in.
8E
lectronics module • VEGAMIP series 60 - receiving unit
37349-EN-121205
Page 9
4 M
ounting
10 Carry
11 Screw the housing cover back on
The electronics exchange is now finished.
As a rule, an exchange of electronics must be documented internally
when Ex applications are involved.
out the adjustment according to the operating instructions of
the sensor
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit9
Page 10
5 Setup
5 Setup
5.1 Setup
Set
up
having exchanged the electronics module, the complete setup
After
must be carried out.
The adjustment should be carried out according to the description in
the operating instructions manual.
10E
37349-EN-121205
lectronics module • VEGAMIP series 60 - receiving unit
Page 11
6 Mainta
in
6 Maint
ain
6.1 How to proceed in case of repair
You can find a repair form as well as detailed information on how to
proceed under
cates".
By doing this you help us carry out the repair quickly and without
having to call back for needed information.
If a repair is necessary, please proceed as follows:
l Print and fill out one form per instrument
l Clean the instrument and pack it damage-proof
l Attach the completed form and, if need be, also a safety data
sheet outside on the packaging
l Please contact for the return shipment the agency serving you.
You can find the agency on our home page www.vega.com.
www.vega.com/downloads and "Forms and certifi-
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit11
Page 12
7 Dismoun
ting
7 Dismou
nting
7.1 Dismounting steps
Warning:
Before dismounting, be aware of dangerous process conditions such
as e.g. pressure in the vessel, high temperatures, corrosive or toxic
products etc.
Take note of chapters "Mounting" and "Connecting to power supply"
and carry out the listed steps in reverse order.
7.2 Disposal
The instrument consists of materials which can be recycled by
specialised recycling companies. We use recyclable materials and
have designed the parts to be easily separable.
Correct disposal avoids negative effects on humans and the environment and ensures recycling of useful raw materials.
Materials: see chapter "Technical data"
If you have no way to dispose of the old instrument properly, please
contact us concerning return and disposal.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive 2002/96/EG and
the respective national laws. Pass the instrument directly on to a
specialised recycling company and do not use the municipal collecting
points. These may be used only for privately used products according
to the WEEE directive.
12E
37349-EN-121205
lectronics module • VEGAMIP series 60 - receiving unit
Page 13
8 Sup
plement
8 Supp
lement
8.1 Technical data
Technical data
are stated in the operating instructions manual of the respective sensor.
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit13
Page 14
8 Suppl
ement
14E
37349-EN-121205
lectronics module • VEGAMIP series 60 - receiving unit
Page 15
8 Sup
plement
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit15