VEGA MIP60 User Manual

Page 1
Ope
rating Instructions
Electronics module
VEGAMI VEGAMIP series 60 - receiving unit
P series 60 - emitting unit
Document ID:
37349
adar
Page 2

Contents

Conten
1 About this document
2 For your safety
3 Product description
4 Mounting
5 Setup
6 Maintain
7 Dismounting
ts
1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
1.3 Symbolism used . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Environmental instructions. . . . . . . . . . . . . . . . . . . . .
3.1 Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Packaging, transport and storage . . . . . . . . . . . . . . .
4.1 Instructions for installation . . . . . . . . . . . . . . . . . . . . .
4.2 Mounting preparations . . . . . . . . . . . . . . . . . . . . . ..
4.3 Mounting steps. . . . . . . . . . . . . . . . . . . . . . . . . . . ..
5.1 Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 How to proceed in case of repair. . . . . . . . . . . . . . . .
7.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 3 3
4 4 4
5 5 5
7 7 7
10
11
12 12
8 Supplement
8.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety instructions for Ex areas
Ple
ase note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.
2 E
13
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
Page 3
out this document
1 Ab
1 Abou
t this document

1.1 Function

This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.

1.2 Target group

This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Inform
ation, tip, note
This symbol indicates helpful additional information.
Cauti
on: If this warning is ignored, faults or malfunctions can
result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
applications
Ex
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
Th
is arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
Battery
This symbol indicates special information about the disposal of batteries and accumulators.
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit 3
disposal
Page 4
2 For
your safety
or your safety
2 F

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.
During work on and with the device the required personal protective equipment must always be worn.

2.2 Appropriate use

The components such as electronics module, accumulator insert, emitting electronics, housing or process components described in this manual are replacement components for existing sensors.

2.3 Environmental instructions

Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection.
The environment management system is certied according to DIN EN ISO 14001.
Please help us full this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage" l Chapter "Disposal"
4 E
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
Page 5
3 Produc
t description
Sco
pe of delivery
Application area
Packaging
Transport
3 Produc
t description
3.1 Conguration
The scope of delivery encompasses:
l Electronics module for emitting unit VEGAMIP series 60
(MP60EE.T**) or electronics module for receiving unit VEGAMIP series 60 (MP60EE.R**)
l Documentation
- this operating instructions manual

3.2 Principle of operation

The electronics module MP60 is suitable as a replacement for the electronics of microwave barrier VEGAMIP series 60.

3.3 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environment­friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device.
Transport inspection
Storage
Stora
ge and transport
temp
erature
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit 5
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside.
Unless otherwise indicated, the packages must be stored only under the following conditions:
l Not in the open l Dry and dust free l Not exposed to corrosive media l Protected against solar radiation l Avoiding mechanical shock and vibration
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
Page 6
3 Produc
t description
l Rela
tive humidity 20 85 %
6 E
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
Page 7
2
1
4 M
ounting
Electro emittin
T**
nics module -
g unit MP60EE.
4 Moun
ting

4.1 Instructions for installation

If the electronics module is defective, it can be replaced by the user.
In Ex
applications only one instrument and one electronics module with
respective Ex approval may be used.

4.2 Mounting preparations

Keep in mind that the emitting and receiving unit require special electronics modules.
l Emitting unit - electronics module MP60EE.T** l Receiving unit - electronics module MP60EE.R**

4.3 Mounting steps

To exchange the electronics module, proceed as follows:
1 Switch opower supply
2 Unscrew the housing cover
3 Lift the terminal block with a small screwdriver and pull it out.
4 Loosen the two screws with a screw driver (Torx size T10 or slot 4)
Fig. 1: Loosening
1 Electronics module 2 Screws (2 pcs.)
5 Pull out the old electronics module
6 Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old electronics module. This applies particularly to instruments used in hazardous areas.
7 Insert the electronics module carefully. Make sure that the plug is
in the correct position.
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit 7
the holding screws
Page 8
2
1
4 M
ounting
tion:
Informa
Make sure that the housing is not rotated during the electronics exchange. Otherwise the plug may be in a dierent position later.
8 Screw in the two holding screws and tighten them
9 Insert the terminal block again. You must hear it snap in.
10 Screw the housing cover back on
The electronics exchange is now nished.
As
a rule, an exchange of electronics must be documented internally when Ex applications are involved.
nics module - re-
Electro ceiving
unit MP60EE.R**
To exchange the electronics module, proceed as follows:
1 Switch opower supply
2 Unscrew the housing cover
3 Lift the terminal blocks with a small screwdriver and pull them out.
4 Loosen the two screws with a screw driver (Torx size T10 or slot 4)
Fig. 2: Loosening
1 Electronics module 2 Screws (2 pcs.)
the holding screws
5 Pull out the old electronics module
6 Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old electronics module. This applies particularly to instruments used in hazardous areas.
7 Insert the electronics module carefully. Make sure that the plug is
in the correct position.
Informa
tion:
Make sure that the housing is not rotated during the electronics exchange. Otherwise the plug may be in a dierent position later.
8 Screw in the two holding screws and tighten them
9 Insert the terminal blocks again. You must hear them snap in.
8 E
lectronics module VEGAMIP series 60 - receiving unit
37349-EN-121205
Page 9
4 M
ounting
10 Carry
11 Screw the housing cover back on
The electronics exchange is now nished.
As a rule, an exchange of electronics must be documented internally
when Ex applications are involved.
out the adjustment according to the operating instructions of
the sensor
37349-EN-121205
Ele
ctronics module VEGAMIP series 60 - receiving unit 9
Page 10

5 Setup

5 Setup

5.1 Setup

Set
up
having exchanged the electronics module, the complete setup
After must be carried out.
The adjustment should be carried out according to the description in the operating instructions manual.
10 E
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
Page 11
6 Mainta
in
6 Maint
ain

6.1 How to proceed in case of repair

You can nd a repair form as well as detailed information on how to proceed under
cates".
By doing this you help us carry out the repair quickly and without having to call back for needed information.
If a repair is necessary, please proceed as follows:
l Print and ll out one form per instrument l Clean the instrument and pack it damage-proof l Attach the completed form and, if need be, also a safety data
sheet outside on the packaging
l Please contact for the return shipment the agency serving you.
You can nd the agency on our home page www.vega.com.
www.vega.com/downloads and "Forms and certifi-
37349-EN-121205
Ele
ctronics module VEGAMIP series 60 - receiving unit 11
Page 12
7 Dismoun
ting
7 Dismou
nting

7.1 Dismounting steps

Warning:
Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vessel, high temperatures, corrosive or toxic products etc.
Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order.

7.2 Disposal

The instrument consists of materials which can be recycled by specialised recycling companies. We use recyclable materials and have designed the parts to be easily separable.
Correct disposal avoids negative eects on humans and the environ­ment and ensures recycling of useful raw materials.
Materials: see chapter "Technical data"
If you have no way to dispose of the old instrument properly, please
contact us concerning return and disposal.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive 2002/96/EG and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. These may be used only for privately used products according to the WEEE directive.
12 E
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
Page 13
8 Sup
plement
8 Supp
lement

8.1 Technical data

Technical data
are stated in the operating instructions manual of the respective sensor.
37349-EN-121205
Ele
ctronics module VEGAMIP series 60 - receiving unit 13
Page 14
8 Suppl
ement
14 E
37349-EN-121205
lectronics module VEGAMIP series 60 - receiving unit
Page 15
8 Sup
plement
37349-EN-121205
Ele
ctronics module • VEGAMIP series 60 - receiving unit 15
Page 16
VEGA Grieshaber KG
ISO 9001
Am Hohenstein 113 77761 Schiltach
Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com
www.vega.com
Printing date:
statements concerning scope of delivery, application,
All
practical use and operating conditions of the sensors and
processing systems correspond to the information avail-
able at the time of printing.
© VEGA Grieshaber KG, Schiltach/Germany 2012
Subject to change without prior notice 37349-EN-121205
Loading...