VEGA FLEX60 User Manual

Operating Instructions
Electronics module VEGAFLEX series 60

Contents

Contents
1 About this document
1.1 Function .............................
1.2 Target group ..........................
2 For your safety
2.1 Authorised personnel....................
2.2 Appropriate use........................
2.3 Safety information for Ex areas.............
2.4 Environmental instructions ................
3 Product description
3.1 Conguration..........................
3.2 Principle of operation ....................
3.3 Storage and transport ...................
4 Mounting
4.1 General instructions.....................
4.2 Mounting preparations VEGAFLEX 61, 62, 65,
66 .................................
4.3 Mounting preparations VEGAFLEX 67 .......
4.4 Mounting procedure.....................
4 4 4
5 5 5 5
6 6 6
7
7 8 9
5 Setup
5.1 Setup ...............................
6 Maintenance
7 Dismounting
7.1 Dismounting procedure ..................
7.2 Disposal .............................
8 Supplement
8.1 Technical data.........................
2 Electronics module - VEGAFLEX series 60
11
13
14 14
15
30207-EN-050607
About this document

1 About this document

1.1 Function

This operating instructions manual has all the information you need for quick mounting and setup of a replacement component. Please read this manual before you start setup.

1.2 Target group

This operating instructions manual is directed to trained personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Information, tip, note
This symbol indicates helpful additional information.
Caution, warning, danger
This symbol informs you of a dangerous situation that could occur. Ignoring this cautionary note can impair the person and/ or the instrument.
Ex applications
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
This arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
30207-EN-050607
Electronics module - VEGAFLEX series 60 3
For your safety

2 For your safety

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the operator. For safety and warranty reasons, any internal work on the instruments must be carried out only by personnel authorised by the manufacturer.

2.2 Appropriate use

Oscillator, emitting electronics, housing or process compo­nents are replacement components for existing sensors.
2.3 Safety information for Ex areas
Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex­approved instruments.

2.4 Environmental instructions

Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection. The environment ma­nagement system is certied acc. to DIN EN ISO 14001.
Please help us full this obligation by observing the environ­mental instructions in this manual:
l Chapter "Storage and transport" l Chapter "Disposal"
4 Electronics module - VEGAFLEX series 60
30207-EN-050607

3 Product description

3.1 Conguration
Product description
Scope of delivery
Area of application
Packaging
Storage and transport tempe-
rature
The scope of delivery encompasses:
l Electronics module VEGAFLEX series 60 l Documentation
- this operating instructions manual

3.2 Principle of operation

The electronics module VEGAFLEX series 60 is suitable for exchange with sensors acc. to the guided microwave principle VEGAFLEX series 60.

3.3 Storage and transport

Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test acc. to DIN EN 24180.
The packaging of standard instruments consists of environ-
ment-friendly, recyclable cardboard. For special versions PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
l Storage and transport temperature see "Supplement –
Technical data – Ambient conditions"
l Relative humidity 20 85 %
30207-EN-050607
Electronics module - VEGAFLEX series 60 5
Mounting

4 Mounting

4.1 General instructions

If the electronics module is defective, it can be replaced by the user.
In Ex applications, only one instrument and one oscillator with appropriate Ex approval must be used.
If there is no electronics module available on site, it can be ordered from the responsible VEGA agency.
Sensor serial number
Assignment
The order data and company data of the sensor must be loaded in the new oscillator. These are the options:
l at the factory by VEGA personnel l or on site by the user.
Information:
When loading on site, rst of all the order data must be downloaded from the Internet (see "Setup").
In both cases, the sensor serial number is necessary. The serial numbers are stated on the type label of the instrument, inside the housing or on the delivery note.
Caution:
The order data and company data contain important preset­tings for the sensor. A reliable operation and a correction of the measurement is not possible without these data.
Electronics modules are adapted to the respective sensor. They dier, e.g. in the signal output, the power supply or
approval.
First of all check by means of the overview in section Mounting preparations, if you are using the suitable electronics module.
Compare the new electronics module with the existing one. The specications on the type label must correspond. This
applies mainly to instruments with approvals.
4.2 Mounting preparations VEGAFLEX 61, 62, 65,
66
4 20 mA/HART
6 Electronics module - VEGAFLEX series 60
Electronics module FX-E.60H. suitable for VEGAFLEX 61, 62,
65, 66 – 4 … 20mA/HART:
30207-EN-050607
4 20 mA/HART four-wire
Probus PA
Foundation Fieldbus
Mounting
l FX-E.60HX (X = without approvals) l FX-E.60HA (A = approvals CA, DA acc. to VEGA product
list)
l FX-E.60HC (C = approvals XM, CX, CM, CK, CI, DX, DM,
DI, GX, UX, UF acc. to VEGA product list).
Electronics module FX-E.60V. suitable for VEGAPULS 61, 62, 63, 65, 66 4 20 mA/HART four-wire:
l FX-E.60VX (X = without approvals) l FX-E.60VA (A = approval DA 4 … 20 mA/HART-Vierleiter) l FX-E.60VC (C = approvals DX, EX , GX acc. to VEGA
product list).
Electronics module FX-E.60P. suitable for VEGAFLEX 61, 62, 63, 65, 66 – Probus PA:
l FX-E.60PX (X = without approvals) l FX-E.60PA (A = approvals CA, DA acc. to VEGA product
list)
l FX-E.60PC (C = approvals XM, CX, CM, CK, GX acc. to
VEGA product list).
Electronics module FX-E.60F. suitable for VEGAFLEX 61, 62, 63, 65, 66 – Foundation Fieldbus FF:
l FX-E.60FX (X = without approvals) l FX-E.60KFC (C = approvals CX CK, GX acc. to VEGA
product list).

4.3 Mounting preparations VEGAFLEX 67

4 20 mA/HART
Probus PA
Foundation Fieldbus
30207-EN-050607
Electronics module - VEGAFLEX series 60 7
Electronics module FX-E.67H. suitable for VEGAFLEX 67 – 4 20 mA/HART:
l FX-E.67HX (X = without approvals) l FX-E.67HC (C = approvals XM, CX, CM, CK, CI, DX, DM,
DI acc. to VEGA product list).
Electronics module FX-E.67P. suitable for VEGAFLEX 67 – Probus PA:
l FX-E.67PX (X = without approvals) l FX-E.67PC (C = approvals XM, CX, CM acc. to VEGA
product list).
Electronics module FX-E.67F. suitable for VEGAFLEX 67 – Foundation Fieldbus FF:
l FX-E.67FX X = without approvals) l FX-E.67CFC (C = approval CX acc. to VEGA product list).
Mounting

4.4 Mounting procedure

Mounting procedure
The electronics module is located in the electronics compart­ment. The below illustrations show the respective position of the electronics compartment in a single or double chamber housing.
1
Fig. 1: Single chamber housing 1 Position of the electronics module
1
Fig. 2: Double chamber housing 1 Position of the electronics module
Proceed as follows:
1 Switch opower supply
2 Unscrew housing cover of the electronics compartment
3 Disconnect the connection cables acc. to the operating
instructions manual of the respective sensor
4 Loosen the two screws with a Phillips screwdriver (size 1)
8 Electronics module - VEGAFLEX series 60
30207-EN-050607
Mounting
1
2
Fig. 3: Loosen the screws 1 Electronics module 2 Screws (2 pcs.)
5 Pull the previous electronics out by holding the opening
levers.
6 Insert the new oscillator carefully.
7 Screw in and tighten the two screws with a Phillips
screwdriver.
8 Connect the connection cables acc. to the operating
instructions manual of the respective sensor
9 Screw the housing cover back on
The electronics exchange is nished.
As a rule, the exchange of the electronics must be documented internally when used in Ex applications.
30207-EN-050607
Electronics module - VEGAFLEX series 60 9
Setup

5 Setup

5.1 Setup

With sensor serial number
Without sensor serial number
Load sensor data
If you have ordered the electronics module by stating the sensor serial number, it is ready for operation after
installation and connection to power supply.
If you have ordered the electronics module without stating the sensor serial number or you are using a suitable
electronics module from stock, you rst have to load the sensor data after installation.
Move via
www.vega.com to the item "serial number search". The order data of the sensor will be displayed after entering the serial number.
Fig. 4: Example for the order data of a sensor.
Below the order data you will nd as an XML le "Sensor data for Service-DTM". Load these data with "Save target as" to
your PC and nally export them via PACTwareand the Service DTM to the sensor.
10 Electronics module - VEGAFLEX series 60
30207-EN-050607
Setup
Adjustment
As a rule, settings already carried out on site with the previous electronics module such as min./max. adjustment, gating out of false echoes etc., however must be repeated.
Tip:
Simply use the copy function of the adjustment module PLICSCOM or the adjustment software PACTware™.
30207-EN-050607
Electronics module - VEGAFLEX series 60 11
Maintenance

6 Maintenance

6.1 Instrument repair

If it is necessary to repair the replacement component, please proceed as follows:
You can download a return form (23 KB) from our homepage www.vega.com under: "Services – Downloads – Forms and
Certicates – Repair form".
By doing this you help us carry out the repair quickly and without having to call back for needed information.
l Print and ll out one form per instrument l Clean the instrument and pack it damage-proof l Attach the completed form and possibly also a safety data
sheet to the instrument.
l Send the instrument to the respective address of your
agency. In Germany to the VEGA headquarters in Schiltach.
12 Electronics module - VEGAFLEX series 60
30207-EN-050607
Dismounting

7 Dismounting

7.1 Dismounting procedure

Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order.

7.2 Disposal

The replacement component consists of materials which can be recycled by specialised recycling companies. We have purposely designed the electronic modules to be easily separable. Mark the instrument as scrap and dispose of it according to government regulations (electronic scrap ordi­nance, ...)
Materials: see "Technical data"
If you cannot dispose of the instrument properly, please
contact us about disposal methods or return.
30207-EN-050607
Electronics module - VEGAFLEX series 60 13
Supplement

8 Supplement

8.1 Technical data

Technical data
are stated in the operating instructions manual of the appropriate sensor.
14 Electronics module - VEGAFLEX series 60
30207-EN-050607
30207-EN-050607
Electronics module - VEGAFLEX series 60 15
VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com
www.vega.com
ISO 9001
All statements concerning scope of delivery, application,
practical use and operating conditions of the sensors and
processing systems correspond to the information avail-
able at the time of printing.
Technical data subject to alterations 30207-EN-050607
Loading...