VEGA EL 6 User Manual

Ope
rating Instructions
Conductive probe EL 6
Document ID:
32654
Cond
uctive

Contents

Conten
1 About this document
2 For your safety
3 Product description
4 Mounting
5 Connecting to power supply
6 Set up
1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Symbolism used . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . .
2.4 General safety instructions . . . . . . . . . . . . . . . . . . . .
2.5 Safety instructions for Ex areas . . . . . . . . . . . . . . . . .
2.6 Environmental instructions. . . . . . . . . . . . . . . . . . . . .
3.1 Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4 Storage and transport . . . . . . . . . . . . . . . . . . . . . . .
4.1 General instructions . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Mounting instructions . . . . . . . . . . . . . . . . . . . . . . . .
5.1 Preparing the connection . . . . . . . . . . . . . . . . . . . . .
5.2 Wiring plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 General information . . . . . . . . . . . . . . . . . . . . . . . . .
3 3 3
4 4 4 4 5 5
6 8 8 8
10 11
12 12
15
7 Maintenance and fault rectication
7.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Rectify malfunctions . . . . . . . . . . . . . . . . . . . . . . . . .
7.3 Shortening the probe . . . . . . . . . . . . . . . . . . . . . . . .
7.4 Instrument repair . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Dismounting
8.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2 Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 Supplement
9.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.3 Industrial property rights . . . . . . . . . . . . . . . . . . . . . .
9.4 Trademark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Cond
16 16 16 16
18 18
19 21 22 22
uctive probe EL 6
32654-EN-100208
out this document
1 Ab
1 Abou
t this document

1.1 Function

This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.

1.2 Target group

This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Inform
ation, tip, note
This symbol indicates helpful additional information.
Cauti
on: If this warning is ignored, faults or malfunctions can
result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
applications
Ex
This symbol indicates special instructions for Ex applications.
32654-EN-100208
Condu
l List
The dot set in front indicates a list with no implied sequence.
à Action
Th
is arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
ctive probe EL 6 3
2 For
your safety
or your safety
2 F

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.
During work on and with the device the required personal protective equipment must always be worn.

2.2 Appropriate use

The EL 6 is a sensor for level detection.
You can nd detailed information on the application range in chapter
"Product description".
Operational reliability is ensured only if the instrument is properly used according to the specications in the operating instructions manual as well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modications are explicitly forbidden.

2.3 Warning about misuse

Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overfill or damage to system components through incorrect mounting or adjustment.

2.4 General safety instructions

This is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The user must take note of the safety instructions in this operating instructions manual, the country­specic installation standards as well as all prevailing safety regulations and accident prevention rules.
The instrument must only be operated in a technically awless and reliable condition. The operator is responsible for trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the compliance of the required occupational safety measures with the current valid rules and regulations and also take note of new regulations.
4 Cond
32654-EN-100208
uctive probe EL 6
2 For
your safety
2.5 Safety
Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.
instructions for Ex areas

2.6 Environmental instructions

Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection.
The environment management system is certied according to DIN EN ISO 14001.
Please help us full this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage" l Chapter "Disposal"
32654-EN-100208
Condu
ctive probe EL 6 5
3 Produc
t description
Scope of delivery
Constituents
3 Produc
t description
3.1 Conguration
The scope of delivery encompasses:
l EL 6 point level sensor l Documentation
- this operating instructions manual
The EL 6 consist of the following components:
l Housing cover l Housing l Process tting with electrode
6 Cond
32654-EN-100208
uctive probe EL 6
1
2
3
3 Produc
t description
Type label
32654-EN-100208
Condu
Fig. 1: Conductive
1 Housing cover 2 Housing 3 Process tting
To create a measuring system you need one conductive probe and a VEGATOR 256C, 532 or 631 signal conditioning instrument.
The type label contains the most important data for identication and
use of the instrument:
l Article number l Serial number l Technical data l Article numbers, documentation
With the serial number, you can access the delivery data of the instrument via search". In addition to the type label outside, you can also nd the serial number on the inside of the instrument.
ctive probe EL 6 7
multiple cable electrode EL 6
www.vega.com, "VEG
A Tools" and "serial number
3 Produc
t description
Application area
Functional principle
Voltage supply
3.2 Princi
EL 6 is a point level sensor with partly insulated conductive electrode for level detection.
EL 6 is very rugged and can be used in all areas of industrial process technology.
The level switch can be used in conductive liquids such as e.g. water.
Typical applications are overll and dry run protection.
The conductive measuring principle places no special requirements on installation. Hence, many dierent applications can be equipped with EL 6.
Conductive probes detect the product resistance when their electro-
des are covered by the product.
The switching signal is determined by the length or mounting position of the respective electrode.
A low alternating current ows through the electodes, is measured for amplitude and phase position by the electronics of the signal conditioning instrument and converted into a switching command.
EL 6 is operated with an external processing unit. The connected signal conditioning instrument powers EL 6 and provides a switching signal. A connected device can be activated directly with this switching command (e.g. a warning sys tem, a PLC, a pump, etc.).
You can nd the exact range of the voltage supply in chapter "Technical data" in the operating instructions manual of the signal conditioning instrument.
ple of operation

3.3 Operation

The probe does not have its own electronics. The measurement is carried out via the connected signal conditioning instrument.

3.4 Storage and transport

Packaging
Transport
8 Cond
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environment­friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device.
32654-EN-100208