Vega D4-F, D4-M, D4-S, D4-C, D4-H Installation Manual

Vega Light Control Systems Holland, Michigan 49424
D4 Post Top Retrofit Kit
INSTALLATION GUIDE
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
WARNING
!
RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE LUMINAIRE’S ELECTRICAL SYSTEM. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN.
RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN THE LUMINAIRES THAT HAS THE
CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWINGS AND WHERE THE INPUT RATING OF THE RETROFIT KIT DOES NOT EXCEED THE INPUT RATING OF THE LUMINAIRE.
RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND ELECTRICAL PARTS MAY BE DAMAGED
WHEN DRILLING FOR INSTALLATION OF LED RETROFIT KIT. CHAECK FOR ENCLOSED WIRING AND PARTS.
ONLY THOSE OPEN HOLES INDICATED IN THE PHOTOGRAPS AND/OR DRAWINGS MAY BE MADE OR
ALTERED AS A RESULT OF KIT INSTALLATION. DO NOT LEAVE ANY OTHER OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS.
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL
COMPONENTS DURING KIT INSTALLATION.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR
OTHER SHARP OBJECTS.
THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. L’INSTALLATION DE CE NÉCESSAIRE DE MODERNISATION
EXIGE UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET DES RISQUES ASSOCIÉS. TOUTE PERSONNE QUI N’EST PAS QUALIFIÉE NE DOIT FAIRE AUCUNE TENTATIVE D’INSTALLATION ET DOIT CONTACTER UNE PERSONNE QUALIFIÉE.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. N’INSTALLER CE NÉCESSAIRE QUE DANS LES
LUMINAIRES DONT LES CARACTÉRISTIQUES DE CONSTRUCTION ET LES DIMENSIONS SONT CONFORME À CELLES ILLUSTRÉES DANS LES PHOTOS ET/OU LES DESSINS ET DONT LA PUISSANCE D’ENTRÉE NOMINALE DU NÉCESSAIRE DE MODERNISATION NE DÉPASSE PAS CELLE DU LUMINAIRE.
IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OUVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE
COMPOSANTS ÉLECTRIQUES AU COURS DE L’INSTALLATION DU NÉCESSAIRE.
AFIN DE PRÉVENIR L’ENDOMMAGEMENT OU L’ABRASION DES CÂBLES, ÉVITER TOUT CONTACT ENTRE
CES DERNIERS ET LE BORD D’UN OBJET TRANCHANT TEL QU’UNE TÔLE.
LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D’UN LUMINAIRE LORSQUE
LA PERTINENCE DE LA COMBINAISON DOIT ËTRE DÉTERMINÉE PAR PAR LES AUTORITÉS COMPÉTENTES
The D4 Post Top Retrofit Kits from Vega Light Control Systems
Designed as an easy and reliable way to convert existing fixtures
Alternative to HID lamps, up to 300W MH and 200W HPS
Use for pole heights up to 30 feet
Eliminates mercury & lead
Reduce carbon footprint & light pollution.
Tested to the most demanding industry standards:
o LM-79, LM-80, In-Situ, TM-21, and DLC o surge testing to UL 1449 3rd edition o UL 1598C 1st Ed. and CSA TIL B-79A
INS-00690-01 20181028
AVERTISSEMENT
Vega Light Control Systems Holland, Michigan 49424
NOTICE
TO AVOID ELECTRIC SHOCK, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OR SERVICING.
TO PREVENT ELECTRIC SHOCK THIS PRODUCT MUST BE PROPERLY GROUNDED.
INSTALLATION MUST BE STRUCTURALLY SOUND TO PREVENT PERSONAL INJURY DUE TO FIXTURE COLLAPSE.
USE CAUTION WHEN HANDLING DURING OR AFTER OPERATION AS IT MAY BECOME HOT AND CAUSE BURNS.
FAILURE TO INSTALL THIS PRODUCT IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC), OR THE CANADIAN
ELECTRICAL CODE (CSA 22.1), ALL APPLICABLE FEDERAL, STATE AND LOCAL ELECTRIC CODES AS WELL AS THE SPECIFIC UNDERWRITERS LABORATORIES (UL) SAFETY STANDARDS FOR THE INSTALLATION, LOCATION AND APPLICATION MAY CAUSE UNSAFE SITUATIONS LEADING TO SERIOUS PERSONAL INJURY, DEATH, PROPERTY DAMAGE AND/OR PRODUCT MALFUNCTION.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
FAILURE OF FIXTURE TO PROVIDE SUFFICIENT WEATHER PROTECTION VOIDS WARRANTY.
TO PREVENT EARLY PRODUCT FAILURE, THIS PRODUCT SHOULD BE INSTALLED IN OPERATING ENVIRONMENTS WITH
MAXIMUM MEAN FIXTURE AMBIENT OPERATING TEMPERATURE FOR LED RETROFIT MODULE: 104°F (40C); MAXIMUM AMBIENT OPERATING TEMPERATURE CANNOT EXCEED 140°F (60°C).
INSTALLATION REQUIREMENTS MAY VARY DEPENDING ON THE LUMINAIRE RETROFITTED.
IF UNCERTAIN, CONTACT VEGA LIGHT CONTROL SYSTEMS CUSTOMER SERVICE TO EVALUATE APPLICABILITY TO
FIXTURE. SUPPORT@VEGALIGHTCONTROL.COM, PHONE: 616-259-0700
1. PRODUCT OVERVIEW
1.1. D4 Post Top Retrofit Specifications
LED Light Engine
30W, 40W, 60W, and 80W Versions
2200K, 3000K, 4000K and 5000K CCT Available
Type 3 and Type 5 Available
True photometric performance through silicone optics
Dimming Options:
0-10vdc dimming available
Timer based overnight schedules
Mechanical Details
4.73” & 5.91” Diameter Light Engines fit ALL globes
Telescoping center post for height adjustment, field settable
Universal Mounting plates available in 4 sizes; 6.25”, 6.5”, 7” or 8” diameter
Brand specific quick change mounting plates also available
Power supply housing and bracket designs to mount above, midway, or below globe/fixture base
Downlight light option for suspended LED engine in shoeboxes, pendants, and colonials.
Performance Details
5 Year replacement warranty, extended warranties available
18kA series surge suppression designed to UL1449 3rd edition
Drivers qualified to:
Life > 50,000 hours
power factor of ≥0.9
THD of ≤20%
LEDs qualified to:
DLC Premium models – L70 of 100,000 hours minimum, L90 of 36,000 hours min.
DLC Standard models – L70 better than 50,000 hours
Vega Light Control Systems Holland, Michigan 49424
1.2. Products Covered
P/N Format: D4 - (style)(watts) - (cct)K - T(type)M - (mounting) - (dimming)
Full Enclosure Kit Style Watts - CCT - Type - Mounting - Dimming Mounting Code Details
D4-F 30 - 22K - T5M - 625 - STD Universal 6.25" plate D4-F 40 - 30K - T3M - 6S - DIM Universal 6.5" plate D4-F 60 - 40K - 7S - PXYZ# Universal 7" plate
(80 NA) - 50K - 8N Universal 8" plate
- C### Other custom configurations
- H### "H" prefix is high output version
Typical Application: Generic shallow fitter where ballast was mounted under cover above fitter
Mid Mount Kit Style Watts - CCT - Type - Mounting - Dimming Mounting Code Details
D4-M 30 - 22K - T5M - CHBTL - STD Hadco B Twistlock D4-M 40 - 30K - T3M - CHBSP - DIM Hadco B Pin & Screw D4-M 60 - 40K - CSBSC - PXYZ# Sternburg Spring Clips D4-M 80 - 50K - CSBTL Sternburg Twistlock
- H### "H" prefix is high output version
- #XX Universal Plates above also applicable
Typical Application: Deeper fitters such as petal style where ballast was mounted into fitter by top plate/cover.
Granville Classic Kit Style Watts - CCT - Type - Mounting - Dimming Mounting Code Details
D4-H 30 - 22K - T5M - CGVC7 - STD Granville Classic 7" Fitter or 4" Fitter D4-H 40 - 30K (T3M - NA) - HGVC7 - DIM "H" prefix is high output version D4-H 60 - 40K - PXYZ#
(80 NA) - 50K
Typical Application: Specific configuration for mounting in Granville Classic 7" and 4" fitters with 19" glass globes.
One piece assembly
Granville Premier Kit Style Watts - CCT - Type - Mounting - Dimming Mounting Code Details
D4-H 30 - 22K - T5M - CGPCS - STD Granville Premier w/ Photo Control Socket D4-H 40 - 30K (T3M - NA) - CGPNS - DIM Granville Premier w/o Photo Control Socket D4-H 60 - 40K - H### - PXYZ# "H" prefix is high output version
(80 NA) - 50K
Typical Application: Specific configuration for mounting in Granville Premier fitters with 19" glass globes.
Two piece assembly.
Downlight Kit Style Watts - CCT - Type - Mounting - Dimming Mounting Code Details
D4-S 30 - 22K - T5M - DNLT - STD 120mm Light Engine flexible Downlight Kit D4-S 40 - 30K - T3M - DNLT2 - DIM 150mm Light Engine flexible Downlight Kit D4-S 60 - 40K - CADJ1 - PXYZ# 14" to 23" span, Larger fixture Downlight Kit D4-S 80 - 50K - C### Other custom configurations
- H### "H" prefix is high output version
Typical Application: Shoebox, Pendant, and Colonial fixtures. Light Engine mounts separately on adjustable arms.
OEM Components Kit Style Watts - CCT - Type - Mounting - Dimming Mounting Code Details
D4-C 30 - 22K - T5M - COEM1 - STD OEM Customer, configuration 1 D4-C 40 - 30K - T3M - CCC01 - DIM OEM Customer CC, configuration 1 D4-C 60 - 40K - CCC02 - PXYZ# OEM Customer CC, configuration 2 D4-C 80 - 50K - C### Other custom configurations
- H### "H" prefix is high output version
Typical Application: LED Light Engine and Power supply only. OEM provides light engine mount.
Loading...
+ 7 hidden pages