Functions
• 400A AC/DC with DC
auto zero
• 1000V DC / 750V AC
• Ohms to 40M
• 45Hz to 400Hz True RMS
• Frequency & Duty Cycle
• Diode Test
• Continuity
Features
• True RMS
• Data hold
• MIN / MAX
• Auto power off
• Test lead storage
1.800.547.5740 • WWW.UEITEST.COM
The DL49B is ideal for HVAC technicians, electricians and plant maintenance professionals with the ability to measure AC and DC inductive amps, making testing generators, compressor pump motors and power converters quick and easy. With its compact design and convenient zippered pouch the durable DL49B will always be ready for the job.
Specifications
DL49B • AC/DC DIGITAL CLAMP-ON MULTIMETER
Includes
• DL49B clamp-on meter
• 2 Test leads
• 2 AAA batteries
• Zippered case
• Instruction manual
AC Current Measurement
Range Resolution Accuracy Overload Protection
40A 0.01A
400A 0.1A
True RMS: 45Hz to 400Hz * Minimum Current for Clamp Measurement: 0.2A
± (2.9% + 15 digits)
± (1.9% + 8 digits)
600V RMS
DC Current Measurement
Range Resolution Accuracy Overload Protection
40A 0.01A
400A 0.1A
True RMS: 45Hz to 400Hz * Minimum Current for Clamp Measurement: 0.2A
± (2.5% + 15 digits)
± (1.5% + 8 digits)
600V RMS
Resistance: < 40MΩ
Range Resolution Accuracy Overload Protection
400Ω 0.1Ω
4kΩ
40kΩ 10Ω
400kΩ 100Ω
4MΩ 1kΩ
40MΩ 10kΩ ± (2.0% + 4 digits)
± (1.0% + 4 digits)
600V RMS
DC Voltage Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV
4V 1mV
40V 10mV
400V 100mV
1000V 1V ± (0.8% + 10 digits)
Overload Protection: 1000V
± (0.5% + 4 digits)
1000V
AC Voltage Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV
4V 1mV
40V 10mV
400V 100mV
750V 1V
True RMS: 45Hz to 400Hz
± (2.0% + 5 digits)
750V RMS
Continuity
Overload Protection Open Circuit Voltage
600V
RMS
Threshold Approx : < 40Ω
< 0.44V
Diode Test
Overload Protection Range Test Current Open Circuit Voltage
600V RMS 2.0V Appx. 0.25mA < 1.6V DC
Frequency
Range Resolution Accuracy Overload Protection
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
± (0.1% + 4 digits) 600V RMS
Duty Cycle
Range Accuracy Overload Protection
1.0 ˜ 99.0% ± (0.2% per kHz + 0.1% + 5 digits) 600V RMS
USA
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • Email: info@ueitest.com 8030 SW Nimbus Ave. Beaverton, OR 97008
Copyright © 2014 UEi. All Rights Reserved
CANADA
1-877-475-0648 • Fax: (604) 278-8299
www.ueitest.com • Email:infocanada@ueitest.com 150-13571 Verdun Place Richmond, B.C. V6V 1W5
EUROPE
+44 1707 375550 • Fax: +44 1707 393277
10/14
PLEASE
RECYCLE
Loading...