Universal Enterprise DL259 User Manual

T
HE
M
OST
V
ERSATILE
& C
OMPLETE
LAMP-ON
O
N
T
HE
M
ARKET
!
DL259
Digital Clamp-On Meter
Work Light / Back Light
• Illuminate your work space to increase visibility & safety
True RMS
• Measure w/ professional level accuracy
Features Include:
• Auto / manual range
• Min/Max record w/ time stamp
• Data Hold
• TRMS AC Amps / AC Volts
• DC Volts
• Ohms / Continuity
• Frequency / Duty Cycle
• Temperature (˚F or ˚C)
• Capacitance
• DC µA (micro amps)
The DL259 Digital Clamp-on is the most versatile and complete test tool on the market. Designed specifically for HVAC/R service and industrial maintenance, this meter has been upgraded with True RMS for increased measuring accuracy. Technicians can increase safety by illuminating dark work areas with a bright LCD Work Light, which also provides a back light display. The DL259 is perfect for measuring flame safeguard current, motor inrush current, run/start capacitors, recording time­stamped temperature highs and lows, and performing general electrical troubleshooting. It's convenient size, teardrop jaw design, upgraded features, and ergonomic controls add speed, comfort, flexibility and safety to your measurement tasks. Three year limited warranty.
Copyright © 2007 UEi Specifications are subject to change without notice. L622 1/07
DL259 • Digital Clamp-On Meter
Standard Accessories:
Test Leads w/ Alligator Clips . . . . . . . . . . . . . . . . . . . . . . . .ATL55
Temperature Probe Adapter . . . . . . . . . . . . . . . . . . . . . . . . .ATT70
Fuse, .5 amp, 500mA/660V . . . . . . . . . . . . . . . . . . . . . . . . . . .AF155
Thermocouple (K-Type) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ATT29
Battery, 9V . . . . . . . . . . . . . . . . . . . . . . . . . . . NEDA 1604 or 6LR61
Holster w/ belt loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NA
Optional Accessories:
Flame Safeguard Test Kit . . . . . . . . . . . . . . . . . . . . . . . . . .ATLFSG
Microwave Diode Booster Test Lead . . . . . . . . . . . . . . . . .ATL60
Line Splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ALS1
K type Thermocouple Probes . . . . . . . . . . . . . . . . . .See Catalog
AC Amps Measurement (45Hz-400Hz) Crest Factor < 3 : 1
DC Low Amps Measurement
DC Volts Measurement
AC Volts Measurement (45Hz-2kHz) Crest Factor < 3 : 1
Ohms Measurement
Capacitance Measurement
Temperature Measurement
Frequency Measurement
Continuity Measurement
Range
40A 400A
Resolution
0.01A
0.1A
Accuracy
±3.0%+20dgts ±2.0%+5dgts
Overload Protection
400A Continuous
Range
40µA 400µA
Resolution
0.01µA
0.1µA
Accuracy
±1.0%+5dgts ±1.5%+2dgts
Overload Protection
400µA/600V
Range
4V 40V 400V 1000V
Resolution
1mV 10mV 100mV 1V
Accuracy
±0.9%+2dgts
Overload Protection
600V RMS
Range
400 4k 40k 400k 4M 40M
Resolution
100m 1 10 100 1k 10k
Accuracy
±0.9%+3dgts
±1.2%+3dgts ±1.5%+5dgts
Overload Protection
600V
Range
4V 40V 400V 1000V
Resolution
1mV 10mV 100mV 1V
Accuracy
±1.9%+3dgts
Overload Protection
600V RMS
Range
1µF 10µF 100µF 1000µF 10000µF
Resolution
0.001µF
0.01µF
0.1µF 1µF 1µF
Accuracy
±1.7%+5dgts
±2.5%+15dgts ±15%+100dgts
Overload Protection
600V
Range
-40˚ to 68˚ (-40 to 20 ˚ ) 68˚ to 400 ( 20˚ to 400˚) 400˚ to 2,498˚
(400˚ to 1, 3 70 ˚ )
Resolution
0.1˚ (0.1˚)
0.1˚ (0.1˚) 1˚ (1˚)
Accuracy
± ( 5 . 4 ˚ ) ± ( 3 . 0 ˚ ) ± 1. 0 % + 3 . 6 ˚ ( ± 1. 0 % + 2 . 0 ˚ ) ±3% of reading (±3% of reading)
Overload Protection
600V
Range
999.9Hz
9.999Hz
99.99Hz
Resolution
0.1Hz 1Hz 10Hz
Accuracy
±0.05%+2d
Overload Protection
600V
Open circuit voltage <2.7V Threshold Approx: <50
Overload Protection 600V
1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • Email: info@ueitest.com
IN CANADA
Vancouver: Phone: 1-877-475-0648 • (604) 278-4511 • Fax: (604) 278-8299 Toronto: Phone: 1-877-475-0648 • Fax: (905) 238-5117
IN EUROPE
Phone: +44 1707 375550 • Fax: +44 1707 393277
Distributed By:
Specifications
PLEASE
RECYCLE
Loading...