Thank you for purchasing the TOPCON Imaging Station IS series.
For the best performance of the instruments, please carefully read these instruc-
tions and keep them in a convenient location for future reference.
1
General Handling Precautions
Before starting work or operation, be sure to check that the instrument is functioning
correctly with normal performance.
Do not aim the instrument directly into the sun
Aiming the instrument directly into the sun can result in serious damage to the eyes. Damage to
the instrument could also result from exposing the instrument’s objective lens to direct sunlight.
The use of a solar filter is suggested to alleviate this problem.
Setting the instrument on a tripod
When mounting the instrument on a tripod, use a wooden tripod when possible.
The vibrations that may occur when using a metallic tripod can effect the measuring precision.
Installing the tribrach
If the tribrach is installed incorrectly, the measuring precision could be effected. Occasionally
check the adjusting screws on the tribrach. Make sure the base fixing lever is locked and the base
fixing screws are tightened.
Guarding the instrument against shocks
When transporting the instrument, provide some protection to minimize risk of shocks. Heavy
shocks may cause the measurement to be faulty.
Carrying the instrument
Always carry the instrument by its handgrip.
Exposing the instrument to extreme heat.
Do not leave the instrument in extreme heat for longer than necessary. It could adversely affect its
performance.
Sudden changes of temperature
Any sudden change of temperature to the instrument or prism may result in a reduction of
measuring distance range, i.e when taking the instrument out from a heated vehicle.
Let instrument acclimate itself to ambient temperature.
Battery level check
Confirm battery level remaining before operating.
Memory back up
The back-up battery built in the instrument needs to be charged approximately 24hrs. before using
it for the first time after purchase. Connect the fully charged battery to the instrument in order to
charge the back-up battery.
Taking the battery out
Leaving the instrument without the battery for more than an hour will cause the memorized data to
be lost, due to low voltage of the back-up battery. Connect the battery as soon as possible or
execute RAM back-up.
No responsibility
TOPCON Corporation has no responsibility for loss of data stored in the memory in case
unexpected accidents.
Battery cover
Completely close the battery cover before using the IS. If the battery cover is not completely
closed, the IS will not operate normally, regardless of whether the battery or the external power
source is used.
If the battery cover is opened while the IS is in operation, operation will automatically be
suspended.
Power OFF
When turning off the power, be sure to turn off the IS’s power switch.
Do not turn off the power by removing the battery.
Before removing the battery, press the power switch and confirm that the power is off. Then
remove the battery.
While using the external power source, do not turn off the IS with the switch on the external power
source.
If the above-mentioned operating procedure is not followed, then, the next time that power is
turned on, it will be necessary to reboot the IS.
Maintenance for driving parts
Every 4,000~5,000 hours operation in total, change grease of driving parts.
Contact your dealer or TOPCON Head Office for the maintenance.
External power source
Use only recommended batteries or external power source. Use of batteries or an external power
source not recommended by us may result in equipment failure.
(For further information see Chapter 14 “BATTERY SYSTEM” .)
2
Display for Safe Use
WARNING
In order to encourage the safe use of products and prevent any danger to the operator and others or damage
to properties, important warnings are put on the products and inserted in the instruction manuals.
We suggest that everyone understand the meaning of the following displays and icons before reading the
“Safety Cautions” and text.
DisplayMeaning
Ignoring or disregard of this display may lead to the danger of death or
serious injury.
CAUTION
•Injury refers to hurt, burn, electric shock, etc.
•Physical damage refers to extensive damage to buildings or equipment and furniture.
Ignoring or disregard of this display may lead to personal injury or physical damage.
Safety Cautions
WARNING
•There is a risk of fire, electric shock or physical harm if you attempt to disassemble or
repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer, only!
•Cause eye injury or blindness.
Do not look at the sun through a telescope.
•Laser beams can be dangerous, and can cause eye injury's if used incorrectly.
Never attempt to repair the instrument yourself.
•Cause eye injury or blindness.
Do not stare into beam.
•High temperature may cause fire.
Do not cover the charger while it is charging.
•Risk of fire or electric shock.
Do not use damaged power cable, plug and socket.
•Risk of fire or electric shock.
Do not use a wet battery or charger.
•May ignite explosively.
Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine.
•Battery can cause explosion or injury.
Do not dispose in fire or heat.
•Risk of fire or electric shock.
Do not use any power voltage except the one given on manufacturers instructions.
•To reduce the risk of hazards, use only CSA/UL certified power supply cord set, cord is
Type SPT-2 or heavier, minimum No.18 AWG copper, one end is provided with a mouldedon male attachment plug cap (with a specified NEMA configuration), and the other end is
provided with a moulded-on female connector body (with a specified IEC non-industrial
type configuration).
•Battery can cause outbreak of fire.
Do not use any other type of charger other than the one specified.
•Risk of fire.
Do not use any other power cable other than the one specified.
•The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
3
•Risk of medical equipment malfunction.
Do not use the instrument in hospitals
•Risk of accident due to malfunction caused by radio waves affecting automatic control operations.
Do not use the instrument near automatic control equipment, such as automatic doors.
•Risk of airplane instrument malfunction.
Do not use the instrument on airplanes.
•Risk of implantable cardiac pacemaker malfunction caused by radio waves.
Ensure that the instrument is 22cm or farther away from implantable cardiac pacemakers.
4
CAUTION
•Do not connect or disconnect equipment with wet hands, you are at risk of electric
shocks if you do!
•Use of controls or adjustment or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
•Let the laser beam reach the aimed object or the target without anybody else in the laser
beam path. In case you operate laser beam open, avoid radiating laser beam to the height
of man's head. It is quite possible for the beam to enter into one's eyes, and it is possible
to lose visual sight temporarily, and lose one's caution and awareness of other dangers
- avoid glaring beam.
•Risk of injury by overturn the carrying case.
Do not stand or sit on the carrying cases.
•Please note that the tips of tripod can be hazardous, be aware of this when setting up or
carrying the tripod.
•Risk of injury by falling down the instrument or case.
Do not use a carrying case with a damaged which belts, grips or latches .
•Do not allow skin or clothing to come into contact with acid from the batteries, if this does
occur then wash off with copious amounts of water and seek medical advice.
•A plumb bob can cause an injury to a person if used incorrectly.
•It could be dangerous if the instrument falls over, please ensure you attach a handle to
the instrument securely.
•Ensure that you mount the tribrach correctly, failing to do so may result in injury if the
tribrach were to fall over.
•It could be dangerous if the instrument falls over, please check that you fix the instrument to the tripod correctly.
•Risk of injury by falling down a tripod and an instrument.
Always check that the screws of tripod are tightened.
•Risk of injury from rotation of the telescope.
Do not look into the telescope while wireless communication is in progress.
5
User
1)This product is for professional use only!
The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to
understand the user and safety instructions, before operating, inspecting or adjusting.
2)Wear the required protectors (safety shoes, helmet, etc.) when operating.
Exceptions from Responsibility
1)The user of this product is expected to follow all operating instructions and make periodic checks of the
product’s performance.
2)The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional
usage or misuse including any direct, indirect, consequential damage, and loss of profits.
3)The manufacturer, or its representatives, assumes no responsibility for consequential damage, and
loss of profits by any disaster, (an earthquake, storms, floods etc.).
A fire, accident, or an act of a third party and/or a usage any other usual conditions.
4)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits
due to a change of data, loss of data, an interruption of business etc., caused by using the product or
an unusable product.
5)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits
caused by usage except for explained in the user manual.
6)The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong
movement, or action due to connecting with other products.
6
Laser Safety
IS series uses the invisible laser beam to measure the distance.
IS series uses the visible laser beam for auto tracking, optical communication.
The IS series products are manufactured and sold in accordance with “Radiation Safety of Laser
Products, Equipment Classification, Requirements and User‘s Guide” (IEC Publication 60825-1) or
“Performance Standards for Light-Emitting Products” (FDA/BRH 21 CFR 1040) provided on the safety
standards for laser beam.
As per the said standards, IS series is classified as “Class 2 (CLASS II) Laser Products”.
The laser beam belongs not very dangerous type but we request you to keep and understand “Safety
standard for users” as mentioned in the manual instruction.
In case of any failure, do not disassemble the instrument. Contact TOPCON or your TOPCON dealer.
Laser class of each mode is as follows.
ModeLaser class
Distance measurementClass 1 (CLASS I)
AutotrackingClass 2 (CLASS II)
Optical communicationClass 2 (CLASS II)
Laser pointerClass 2 (CLASS II)
Labels
Find the labels which describes the caution and safety about the laser beam as follows in IS series.
We request you to replace it one anytime the caution labels are damaged or lost and paste a new one at the
same place. You can get the labels from Topcon or your dealer.
Beam aperture
AVO ID EXPOSURE
LASER LIGHT IS EMITTED
FROM THIS APERTURE
Warning Label
Aperture Label
CAUTION
LASER RADIATION
Explanatory Label
Each label is differed by the market.
7
Symbol Mark while the Laser is Emitting.
These symbol marks will come on while the laser is working
Battery Level Indicator
Refer to see Chapter 2.4 “Battery Power
Remaining Display” . for further
information.
Rotation Indicator
Refer to Section 1.14 “Rotating Method”
for further information.
EDM workingNPMNon-Prism constant correction value
NPNon-prism mode
LNPNon-prism long mode
Laser emitting markSetting Non-prism long range
15
1 NOMENCLATURE AND FUNCTIONS
•
The symbol marks for Auto-tracking and Auto-collimating
Auto-collimating
Laser is emitting
(
)
The instrument is in auto-collimating
status.
Waiting (
Laser is emitting
The instrument is in waiting status.
Failure in auto-collimating.
(Laser is off)
The instrument could not find the
target prism during auto-collimating.
1.2.4 Display keys
KeysName of KeyFunction
Auto-tracking
(
Laser is emitting
)
The instrument is in auto-tracking
status.
)
Searching (
The instrument is searching a
Laser is emitting)
prism.
Auto-collimating
ANG
measuring key
measuring key
measuring key
RECREC key Result of measurement is transferred.
1.2.5 Shortcut Keys
Software Reset[Shift]+[Func]+[ESC]
Windows Start Menu[Ctrl]+[ESC]
Shortcut Commands
Windows CE
Task Manager
key
Angle
Distance
Coordinate
Tu rn the collimating ON/OFF.
To be angle measuring mode.
To be distance measuring mode.
To be coordinate measuring mode.
Continue tapping on an item
or
[Alt]+Tap on an item
[Alt]+[TAB]
to switch to another active program or to END Task on running program(s).
16
1 NOMENCLATURE AND FUNCTIONS
1.3 Backlight, Key Light Adjustment
1.3.1 How to Adjust Reducing Time of Backlight
To conserve battery power, this instrument would automatically turn the backlight off or reduce the
backlight brightness by itself when it’s not in use.
In addition, the instrument can control the backlight brightness automatically by an equipped
illuminometer.
You can adjust the settings of this function to conserve more battery power or set your liking.
1
Press the icon [Start]-[Settings]-[Control Panel]-[Power].
You can see the "Power Properties" screen on Display.
2
Press the tab [Backlight].
You can see the "Backlight" screen on Display.
17
1 NOMENCLATURE AND FUNCTIONS
3
Press the time-menu down arrow to select the reducing time.
Factory setting is ‘3 minutes' as default.
4
Press the [OK] key on title bar. After that "Power Properties" screen will close automatically.
18
1.3.2 Adjust the Backlight Brightness by Manual
1
On the "Backlight" screen, please check it 'OFF' "An illuminometer is used.”.
(Factory setting is 'ON' as default)
The "Brightness adjusting slide bar” will be appeared on Display.
2
Adjust the brightness by pressing [Dark-Bright] button.
1 NOMENCLATURE AND FUNCTIONS
3
Press the [OK] key on title bar. After that "Power Properties" screen will close automatically.
19
1 NOMENCLATURE AND FUNCTIONS
1.3.3 Selecting the Automatic Lighting Option
1
On the "Backlight" screen, select a Radio button from “Automatic lighting” column.
(Factory setting is “The light is switched on with an illuminometer.” as default)
2
Press the [OK] key on title bar. After that "Power Properties" screen will close automatically.
20
•The “Time until it switches off a backlight.” time-menu is not activate if “The light is
switched on with an illuminometer.” option is selected.
1 NOMENCLATURE AND FUNCTIONS
1.3.4 Selecting the Key Light Option
The Key Light option:
[Key light is always off, Key light is always on, Key light synchronizes with backlight]
1
Press the tab [Key Light].
You can see the "Key Light" screen on Display.
2
Select a Radio button.
(Factory setting is “Key light synchronizes with backlight.” as default)
3
Press the [OK] key on title bar. After that "Power Properties" screen will close automatically
21
1 NOMENCLATURE AND FUNCTIONS
1.4 RAM Data Backup
If your device had not recharged during several days, the battery will be running down, and you would
lose all of data on the device other than that in the "Internal Disk (internal micro SD card)".
In addition, you might perform hardwarereset by the hardware problem or software problem. In this
case, you would lose all data same as the above.
You can use Backup function of the instrument in order to evade such kind of uneasiness. Your data will
be restored to latest condition 1) automatically when rebooting by using the Backup function.
The Backup function saves all data files of RAM (except for OS files), registry file and additionally
installed programs into named "Backup" folder in the "Internal Disk".
1) The conditions that you executed the backup function last.
* Restoring former backup data may be incomplete if you upgrade OS version.
1.4.1 Execute the Backup Function
Make sure the mode is Windows CE mode.
1
Press the icon [Start]-[Settings]-[Control Panel]-[Backup].
22
You can see the "RAM Backup" screen on Display.
2
Press the [RAM data backup] key.
You can see the "Confirmation screen" on display.
3
Press the [YES] key.
Backup function will start.
1 NOMENCLATURE AND FUNCTIONS
Return to "RAM Backup" screen automatically, when the data back up has been completed.
4
Press the [OK] key on title bar. After that "RAM Backup" screen will close automatically.
•Backing up data may be incomplete if remaining capacity of "Internal Disk" is not enough.
Please make sure the remaining capacity of "Internal Disk" before proceeding to the data
back up.
•Restoration will be impossible if you delete the "Backup" folder in the "Internal Disk".
23
1 NOMENCLATURE AND FUNCTIONS
1.4.2 Set the Automatic Backup for Every Suspension
1
On the "RAM Backup" Screen, please check it 'ON' the "RAM data will be backed up before
suspension.".
(Factory setting is 'ON' as default)
2
Press the [OK] key on title bar. After that, "RAM Backup" screen will close automatically.
1.4.3 Set the Restoration after Hardware Reset
1
On the "RAM Backup" Screen, check it 'ON' the "Data restoration after hard reset.".
(Factory setting is 'ON' as default)
24
2
Press the [OK] key on title bar. After that, "RAM Backup" screen will close automatically.
1 NOMENCLATURE AND FUNCTIONS
1.5 Hardware Reset
If your instrument not responding or an application hangs, please try to perform a software reset first.
Still, when useless, please perform hardware reset.
You will lose all of data on the device other than that in the "Internal Disk" after hardware reset
and will need to reinstall the applications and the data you install on your instrument.
Card cover lever
1
2
Stylus pen
Hardware reset switch
3
1.6 Cover Sensor
Completely close the battery cover before using the instrument.
Pull the card cover lever to open the card cover.
Insert the stylus into the unit of hardware reset
switch.
Press the switch for two seconds.
The instrument will reboot.
Battery cover
Battery
Cover sensor
•If the battery cover is not completely closed, the instrument will not operate normally,
regardless of whether the battery or the external power source is used.
•If the battery cover is opened while the instrument is in operation, operation will
automatically be suspended.
25
1 NOMENCLATURE AND FUNCTIONS
1.7 Touch Panel Calibration
If your instrument is not responding properly to your taps, you may need to calibrate the touch panel.
•How to calibrate the touch panel
1
Press the icon [Start]-[Settings]-[Control Panel][Stylus].
You can see the "Stylus Properties" screen on
Display.
2
Press the tab “Calibration”.
26
3
Press the [Recalibrate] key.
1 NOMENCLATURE AND FUNCTIONS
4
Using the stylus pen, press the center of the
targets on the screen.
5
After pressing all targets (5 points), press the
[ENT] key, or tap the display.
6
Press the [OK] key.
The display returns to previous menu.
27
1 NOMENCLATURE AND FUNCTIONS
1.8 Operating Panel Key
To operate the keys on the screen, touch them lightly with either the accessor y stylus pen or your finger.
Use either the stylus pen or your finger.
Do not use a ballpoint pen or a pencil.
1.8.1 Operating Key
Light sensor
adjust backlight
KeysName of KeyFunction
0-9
A -/
Esc
ENT
Tab
B.S.
Shift
Ctrl
Alt
Func
Numeric key
Alpha keyEntering Alphabets.
Escape keyReturning to the previous mode or display.
Star keyStar key mode is used for each presetting or displaying.
Enter keyPress at the end of inputting values.
Tab keyMoves the cursor to the right or downwards.
Back space keyWhen inputting numbers or characters, return the cursor to the left.
Shift keyUsed with other keys. Refer to "1.2.5 Shortcut Keys".
Control keyUsed with other keys. Refer to "1.2.5 Shortcut Keys".
Alt keyUsed with other keys. Refer to "1.2.5 Shortcut Keys".
Function keyUsed with other keys. Refer to "1.2.5 Shortcut Keys".
Alphabet keySwitches the keys to alphabet input mode.
Microphone
The stylus pen is stored beside the display.
Entering numerals.
Switching between wide-angle and telescopic images. (Keys [1] and [2])
Switching the cross-hairs. ON(black)/ON(white)/OFF (Key [9])
28
S.P.
Cursor
Space keyInputs a space.
Input panel keyDisplays the software input panel.
Moves the selected item or the cursor laterally and vertically.
Changes the image's magnification. ("Left" and "Right" keys)
Changes the image's brightness. ("Up" and "Down" keys)