3
Absolute Maximum Ratings Thermal Information
DC Supply Voltage (VCC). . . . . . . . . . . . . . . . . . . . . . . -0.5V to 6.0V
DC Input Diode Current, IIK (for VI< -0.5V) . . . . . . . . . . . . . . -20mA
DC Output Diode Current, IOK (for VO < -0.5V) . . . . . . . . . . . -50mA
DC Output Sink Current per Output Pin, IO . . . . . . . . . . . . . . .70mA
DC Output Source Current per Output Pin, IO. . . . . . . . . . . . -30mA
DC VCC Current (ICC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140mA
DC Ground Current (I
GND
). . . . . . . . . . . . . . . . . . . . . . . . . . .528mA
Operating Conditions
Operating Temperature Range (TA) . . . . . . . . . . . . . -55oC to 125oC
Supply Voltage Range, V
CC
CD74 Series, TA = 0oC to 70oC . . . . . . . . . . . . . . .4.75V to 5.25V
CD54 Series,TA = -55oC to 125oC . . . . . . . . . . . . . . .4.5V to 5.5V
DC Input Voltage, VI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to V
CC
DC Output Voltage, VO. . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to ≤ V
CC
Input Rise and Fall Slew Rate, dt/dv. . . . . . . . . . . . . . . . 0 to 10ns/V
Thermal Resistance (Typical, Note 3) θJA (oC/W)
PDIP Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
SOIC Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Maximum Junction Temperature. . . . . . . . . . . . . . . . . . . . . . . 150oC
Maximum Storage Temperature Range . . . . . . . . . .-65oC to 150oC
Maximum Lead Temperature (Soldering 10s). . . . . . . . . . . . . 300oC
(SOIC Lead Tips Only)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” maycause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
3. θJA is calculated in accordance with JESD 51.
Electrical Specifications 74FCT Commercial Temperature Range 0
o
C to 70oC, VCC Max = 5.25V, VCC Min = 4.75V
54FCT Extended Industrial Temperature Range -55oC to 125oC; VCC Max = 5.5V, VCC Min = 4.5V
PARAMETER SYMBOL
TEST
CONDITIONS
VCC (V)
AMBIENT TEMPERATURE (TA)
UNITS
25oC0
o
C TO 70oC -55oC TO 125oC
V
I
IO (mA) MIN MAX MIN MAX MIN MAX
High Level Input Voltage V
IH
4.5 to 5.5 2 - 2 - 2 - V
Low Level Input Voltage V
IL
4.5 to 5.5 - 0.8 - 0.8 - 0.8 V
High Level Output Voltage V
OH
VIH or -15 Min 2.4 - 2.4 - - - V
V
IL
-12 Min 2.4 - - - 2.4 - V
Low Level Output Voltage V
OL
VIH or 64 Min - 0.55 - 0.55 - - V
V
IL
48 Min - 0.55 - - - 0.55 V
High Level Input Current I
IH
V
CC
Max - 0.1 - 1 - 1 µA
Low Level Input Current I
IL
GND Max - -0.1 - -1 - -1 µA
Three-State Leakage
Current
I
OZH
V
CC
Max - 0.5 - 10 - 10 µA
I
OZL
GND Max - -0.5 - -10 - -10 µA
Short Circuit Output Current
(Note 4)
I
OS
VCC or
GND
VO = 0
Max -60 - -60 - -60 - mA
Input Clamp Voltage V
IK
VCC or
GND
-18 Min - -1.2 - -1.2 - -1.2 V
Quiescent Supply Current,
MSI
I
CC
VCC or
GND
0 Max - 8 - 80 - 500 µA
AdditionalQuiescent Supply
Current perInput Pin TTLInputs High, 1 Unit Load
∆I
CC
3.4V
(Note 5)
Max - 1.6 - 1.6 - 2 mA
NOTES:
4. Not more than one output should be shorted at one time. Test duration should not exceed 100ms.
5. Inputs that are not measured are at VCC or GND.
6. FCT Input Loading: All inputs are 1 unit load. Unit load is ∆ICC limit specified in Static Characteristics Chart, e.g., 1.6mA Max at 70oC.
CD54FCT245, CD74FCT245