Teac HS-8 Firmware V1.40

HS-8
New functions in firmware V1.40
The following functions have been added in firmware V1.40
0 Support for loading files that have been recorded by other devices 0 T/C Frame Sync REC function added 0 REC STOP Position function added 0 Added display of take end timecode on take list sccreen 0 Sound Report file output function added 0 ONLINE fader setting value display added 0 Metering Point switching function added 0 Warnings added when working with files/folders using an FTP client
application
0 Pressing the Esc key on a connected keyboard now has the same function
as using the EXIT/CANCEL [PEAK CLEAR] key on the front of the unit
0 Connected keyboard shortcut key functions added 0 New pop-up messages added
Support for loading files that have been recorded by other devices
The unit can now handle files that were recorded by other devices when they are loaded in the current folder without rebuilding the folder
T/C Frame Sync REC function added
A T/C Frame SYNC REC function has been added to the REC MODE page of the REC SETUP screen. This function starts recording precisely at the next timecode generator frame division.
REC STOP Position function added
A REC STOP Position function has been added to the REC MODE page of the REC SETUP screen. This function allows you to set the position after recording stops to either the start or the end of the take.
REC STOP POSITION
Take Start (default): After recording, the unit stops at the start of the take that was recorded. Use this setting when you want to play a take immediately after recording, for example.
Take End: After recording, the unit stops at the end of the take that was recorded. Use this setting when you want to check the take length or take end timecode using the time counter, for example.
Added display of take end timecode on take selection screen
An “END T/C” time display column, which shows the timecode of the take end, has been added to the take list screen.
T/C Frame Sync REC
OFF (default): Recording starts when the operation to start recording occurs regardless of the timecode generator value.
ON: Recording starts precisely at the next timecode generator frame division.
Example
Frame division
T/C Frame Sync Rec:OFF
T/C Frame Sync Rec:ON
NOTE
This unit notes recording start timestamps with sample precision. For this reason, in editing environments that round audio file positions to frame preci­sion (e.g. AVID Media Composer, OMF files, etc.), the positions of files recorded by this unit will be off when synchronized with video. By turning this function on, recording will be started precisely at the next timecode generator frame division, so the original positions of files recorded by this unit can be preserved when synchronized with video in such editing environments.
Recording start operation
Timecode time
02 03 04 05
Sound Report file output function added
A Sound Report function has been added that exports current take list infor­mation as a CSV file.
1. Open the current take list.
2. Press the MENU button to open the pull-up menu, and touch the CREATE
Report button.
NOTE
The CREATE Report button will only appear for the current take list.
D01162820C
TAS CAM H S-8 1
HS-8
3. When the confirmation message appears, touch the OK button.
Current take list information is output to a file in the current folder of the current project. The file is named with this format: “<current project name>_<current folder name>_Report.csv”.
NOTE
If a file with the same name already exists, a message confirming that you want to overwrite it will appear. Touch the OK button to overwrite that file.
ONLINE fader setting value display added
ONLINE fader setting value display has been added to the CHANNEL SETUP screens.
Metering Point switching function added
A function that allows you to set the meter display to before or after the ONLINE fader has been added to the METER SETUP and CHANNEL SETUP screens.
METER SETUP screen
p
Metering Point
Pre Fader (default): The meters show the levels before the ONLINE fader. Post Fader: The meters show the levels after the ONLINE fader.
CHANNEL SETUP screens
p
CH1 SETUP screen
CH1 SETUP screen
L/R SETUP screen
NOTE
i Since the system uses only one ONLINE fader setting, the same setting value is
linked on all channel pages and the L/R page.
i The ONLINE fader can be operated when a TASCAM RC-HS20PD (sold sepa-
rately) is connected. It cannot be used with just the main unit. If no RC-HS20PD is connected, the ONLINE fader setting value will be 0dB.
L/R SETUP screen
METER button
You can switch whether the meters show the levels before or after the ONLINE fader. Touch the left button to have the meters show the levels before the ONLINE fader. Touch the right button to have the meters show the levels after the ONLINE fader.
NOTE
i Before this function was added, the Metering Point was fixed to the Post Fader
setting. Be aware that with the addition of this function, the default Metering Point setting is now Pre Fader.
i Since the system uses only one Metering Point setting, the same setting value is
linked on all channel pages and the L/R page.
i The ONLINE fader can be operated when a TASCAM RC-HS20PD (sold sepa-
rately) is connected. It cannot be used with just the main unit.
2 TAS CAM H S-8
HS-8
Warnings added when working with files/folders using an FTP client application
When an FTP client application is used to conduct one of the following opera­tions, a message recommending that the folder be rebuilt now appears and a X icon appears above the relevant button.
0 A file present in the take list is deleted from the current folder 0 A folder is deleted
NOTE
Always rebuild if a message recommending that the folder be rebuilt and the X icon appears. If you do not rebuild, discrepancies between the management and audio files will occur, resulting in the following symptoms.
i Deleted folders and files will be shown
Connected keyboard shortcut key functions added
The following shortcut key functions for connected keyboards have been added.
Home key: Open Home Screen End key: Open MENU screen Page Down key: Open PROJECT screen Ctrl+T key: Open PROJECT take selection screen Ctrl+R key: Open current take name editing screen Ctrl+N key: Open NEXT TAKE NAME screen Tab key: Set a mark point
New pop-up messages added
Message Details and responses Remarks
Directory contents changed via FTP. REBUILD required. REBUILD Now?
Rebuild changed Directory? The changed directory will be rebuilt.
Rebuild current project and changed Directory? Rebuild current folder and changed Directory? Rebuild selected project and changed Directory? Rebuild selected folder and changed Directory? Create Sound Report File for Current Take List?
"ffffffff" "ffffffff" already exists. Overwrite this report? Cannot create report. Not enough space on CFn Sound Report creation failed. The Sound Report file could not be created.
--- Circle Take --­Did not Edit n Take
that is/are read-only.
Cannot Edit Next Take Name Prefix when in Folder Name mode Please select User Word mode.
The directory contents were changed by FTP, so rebuilding is required.
After using a file on this unit by FTP, this message will appear when you touch a REBUILD button showing an B icon.
The current project and changed directory will be rebuilt.
The current folder and changed directory will be rebuilt.
The selected project and changed directory will be rebuilt.
The selected folder and changed directory will be rebuilt.
A Sound Report file will be created for the current take list. "ffffffff" = Sound Report file name
A file with the same name already exists. Do you want to overwrite the existing report?
The currently selected CF card does not have enough open space to create the report.
For takes set as read-only, "@" marks cannot be added to or removed from the beginnings of file names.
If the setting on the Home screen, NEXT TAKE NAME tab is set to "Folder Name", the Ctrl + N shortcut from the exter­nal keyboard to edit the Take name prefix is not available. Please select User Word mode.
After using a file on this unit by FTP, this message will appear when you touch a REBUILD button showing an B icon. After using a file on this unit by FTP, this message will appear when you touch a REBUILD button showing an B icon. After using a file on this unit by FTP, this message will appear when you touch a REBUILD button showing an B icon. After using a file on this unit by FTP, this message will appear when you touch a REBUILD button showing an B icon.
"ffffffff" = Sound Report file name
n = 1 or 2
n = number of takes
TAS CAM H S-8 3
HS-8
New functions in firmware V1.30
The following functions have been added in firmware V1.30
0 Network functions (FTP, Telnet and VNC)
REMOTE/KEYBOARD
0 0 Take Rename function 0 Rec Fn Stop Monitor function 0 Monitor muting function 0 Slate tone function 0 USER BITS Source setting function 0 Addition of take end time code display 0 Ability to receive digital input signals that are in consumer format 0 Clear function can be executed using the SHIFT and BACKSPACE keys on
an external keyboard
0 Cursor can be moved using the up and down arrow (2/x), HOME and END
keys of an external keyboard
0 Title display changes on the 0 PROJECT key now moves up a level when the PROJECT screen is open.
Network functions (FTP, Telnet and VNC) added
ETHERNET page added to the REMOTE SETUP screen
Use this to make settings related to Ethernet communication.
EXTERNAL Control
and
PROJECT
screen
Lock/Unlock settings
IP Address/Subnet Mask/Default Gateway editing screen
Touch the corresponding area of the page to open its value setting screen.
0 Each field can contain up to 3 digits. (You do not need to input “0” before
values of 1–2 digits.)
0 The first field is selected when a screen opens. 0 After a field is selected, touching a number button will enter that digit.
When touched, further digits will be added to the end of the same field.
0 Touch the period (point) button to move to the next field.
Example
Screen opened 192. 168. 1. 1 “1234” input 234. 168. 1. 1 (First “1” is discarded)
“.” input 234 168. 1. 1
REMOTE SETUP
screen
ETHERNET
STATUS
This shows the unit's MAC Address and current IP Address.
IP MODE
Use these buttons to enable or disable Ethernet functions. Setting buttons:
IP SETUP
Use to switch between DHCP and STATIC. When set to
Address, Subnet Mask
automatically acquired. When set to STATIC, you must set the
Default Gateway
and
Setting buttons:
LINK SPEED
Use these buttons to set the link speed.
Setting buttons: ing to connection),
Password
Set the password. (See "CHANGE PASSWORD screen” below.)
IP Address/Subnet Mask/Default Gateway
These show the current values of these settings. When
STATIC
to Mask/Default Gateway editing screen” below.)
Default values: 0. 0. 0. 0
Depending on the shown below.
Disable
DHCP
AUTO
, use these field to set the values. (See “IP Address/Subnet
(default value),
, and there is a DHCP server on the LAN, the
DHCP, STATIC
100M
IP SETUP
Default Gateway
and
items manually.
(default value automatically adjusts speed accord-
(operates with fixed speed of 100 Mbps.)
setting, this area appears differently as
Enable
IP Address, Subnet Mask
(default value)
IP
items should be
IP SETUP
is set
CHANGE PASSWORD screen
Touch the
SETUP
where you can set the password. Up to 9 characters can be used.
Change
screen
button in the
ETHERNET
page to open the
Password
section of the
CHANGE PASSWORD
REMOTE
screen
DHCP STATIC Field selected
4 TAS CAM H S-8
HS-8
Network function (FTP, Telnet and VNC) details
FTP (file transfer protocol)
By using an FTP client application, you can transfer files between this unit and a computer.
Connect to this unit and login in the same way as with other FTP servers. After connecting and logging in, “A:” and “B:” will appear in the root directory. These correspond to the unit's CF1 and CF2 slots. If the corresponding slot does not contain a card, the “A:” or “B:” will appear empty.
NOTE
i To display Japanese, use an FTP application that supports Unicode. i Always set the maximum number of simultaneous transfers of the FTP client
application to “1”. If not set to “1” files cannot be transferred properly.
i For information about FTP client applications that have been confirmed to
work properly with this unit, please contact TASCAM customer support.
Required settings for connecting by FTP
The following settings are necessary for connecting to this unit by FTP.
IP address: This unit's IP address is shown in the
field of the
REMOTE SETUP
Port: 21 User name: HS-8 (cannot be changed, case sensitive) Password: HS-8 (default, case sensitive) This setting can be changed by using the
Change ERNET
page.
button on the
REMOTE SETUP
NOTE
i The number of simultaneous connections is “1”. Depending on the FTP client
application, two simultaneous connections with this unit might be possible, but files might not be transferred correctly, so we recommend that you do not use two or more simultaneous FTP connections with this unit.
i FTP connections cannot be made when EXTERNAL Control has been set to
LOCK on the
Lock Setup
screen. Likewise, setting this to LOCK will end
any active FTP connection.
i Changing any settings on the
REMOTE SETUP
screen of the
page will also end any active FTP connection.
Working with files using an FTP client application
CAUTION
When adding, overwriting or deleting files/folders from this unit using an FTP client application, always follow the procedures below to rebuild the entire CF card that was changed.
If you do not rebuild the card, inconsistencies between the syetem files and audio files will occur, leading to problems such as the following.
i Added files and folders will not appear i Deleted files and folders will continue to appear i Overwritten files will not play back properly
Procedures for rebuilding the entire CF card
1. Open the project selection screen.
2. While no project is selected, press the MENU button to open a pull-up menu.
3. Press the REBUILD button in the pull-up menu.
4. When a confirmation message appears in a pop-up window, press the OK button or the DATA dial.
Read files from the unit
p
You can read files from this unit at any time.
IP Address
ETHERNET
screen
page.
Password
ETH-
screen
ETHERNET
Delete a file on the unit
p
The current take can be deleted only when the unit is stopped. Files other than the current take can be deleted at any time.
Add a new folder to this unit
p
You can add a new folder to this unit at any time.
Delete a folder from this unit
p
You can only delete the current folder when stopped. You can delete any folder other than the current from this unit at any time.
Edit the names of files/folders on this unit
p
You cannot edit the names of files/folders on this unit.
CAUTION
i If overwriting causes the size, number of channels, bit-rate or sampling
frequency of an audio file to be different from the previous file, inconsistencies could occur between the system files and audio files. If such an inconsistency occurs, the following error message will appear when you start playback.
i Do not overwrite an existing audio file with a file that uses a different sampling
frequency. The inconformity that results could become unresolvable.
Remote control by Telnet
Remote control of this unit is possible over Ethernet via port 23 using Telnet.
Necessary setting for connections by Telnet
The following settings are necessary for connecting to this unit by Telnet.
IP address: This unit’s IP address is shown in the
field of the
REMOTE SETUP
IP Address
ETHERNET
screen
page. Port: 23 Password: HS-8 (default, case sensitive) This setting can be changed by using the
Change ERNET
page.
button on the
REMOTE SETUP
Password
ETH-
screen
Connecting to the unit by Telnet
1. After connecting with this unit by Telnet using the above IP address and
port number, press the computer Enter key.
2. When
3. When login succeeds,
NOTE
Enter Password
appears on the Telnet console, input the
above password and press the Enter key.
Login Successful
appears on the Telnet
console. Input “exit”and press the Enter key to end the Telnet connection.
i 2 simultaneous Telnet connections are possible. i Telnet connections cannot be made when
set to
LOCK
Lock Setup
on the
EXTERNAL Control
has been
screen. Likewise, setting this to LOCK will
end any active Telnet connections.
i Changing any settings on the
REMOTE SETUP
screen of the
ETHERNET
page will also end any active Telnet connection.
i The commands used for the telnet control are the same as for RS-232C control.
Please see the RS-232C documentation available on our website and contact TASCAM customer support if additional help is needed.
Add new files to the unit
p
You can add files to this unit at any time. When recording, if you add BWF files to the current session, they will be
shown in the list with existing files, recorded files and added files in that order.
Overwrite existing files on the unit
p
You can only overwrite the current take when the unit is stopped. You can overwrite other existing files at any time. However, if the
All Take
ting is
PLAY SETUP
, during playback you might not be able to overwrite
screen
GENERAL
Play Mode
page
the take following the current take depending on the timing.
set-
TAS CAM H S-8 5
HS-8
VNC (virtual network computing)
By using a VNC viewer application, you can view and operate the contents of this unit's LCD screen on a computer.
In the VNC viewer application, you can use a mouse to conduct the following operations.
i Mouse left click: Same as touching the unit's LCD. i Mouse wheel click: Same as pressing the unit's ENTER key. i Mouse wheel operation: Same as using the unit's D ATA dial. i Mouse wheel push and turn: Same as using the unit's DATA dial while
pushing it to make large setting changes (COARSE mode operation).
In addition, when the VNC viewer application is active, you can conduct the following operations by using the computer keyboard.
i F1 to F12 keys: These work the same as an external keyboard con-
nected to the unit. For details see the “List of keyboard operations” in “Operation using a computer keyboard” in “12 – Other functions” of this unit's manual.
i Home key: This works the same as this unit's HOME key and opens
the Home Screen.
Press the End key while pressing and holding the Home
key to open the
LOCK SETUP
screen.
i End key: This works the same as this unit's MENU key and opens
the MENU screen.
Press the End key while pressing and holding the Home
key to open the
LOCK SETUP
screen.
i Page Down: This works the same as this unit's PROJECT key and
opens the
PROJECT
screen.
i 2 key: This works the same as turning this unit's DATA dial
right.
i x key: This works the same as turning this unit's D ATA dial left. i Character input keys: Use to input characters when a keyboard screen
appears on the unit.
REMOTE/KEYBOARD and EXTERNAL Control Lock/Unlock settings added
REMOTE/KEYBOARD
have been added on the
REMOTE/KEYBOARD
0 When
keyboard connected to a remote connector is used, the following pop-up message appears when remote/keyboard control is locked.
EXTERNAL CONTROL
0 When
ducted using RS–232C, RS–422, PARALLEL or ETHERNET, the following pop-up message appears when external input is locked.
EXTERNAL Control
and
LOCK SETUP
is set to
is set to
screen.
LOCK
LOCK
Lock/Unlock settings
, if a remote control or
, if an operation is con-
Necessary setting for VNC connections
The following settings are necessary for connecting to this unit using a VNC viewer application.
IP address: This unit’s IP address is shown in the
field of the
REMOTE SETUP
IP Address
ETHERNET
screen
page. Password: HS-8 (default, case sensitive) This setting can be changed by using the
Change ERNET
page.
button on the
REMOTE SETUP
Password
screen
NOTE
i 2 or more simultaneous VNC connections are not possible.
EXTERNAL Control
i When
has been set to
LOCK
Lock Setup
on the screen, display is possible but operation is not when using a VNC viewer application.
i Changing any settings on the
REMOTE SETUP
screen of the
ETHERNET
page will also end any active VNC connection.
i For information about VNC viewer application that have been confirmed to
work properly with this unit, please contact TASCAM customer support.
i When files are being transferred by FTP or when the system sampling fre-
quency is 88.2 or 96 kHz, VNC viewer application display and operation will not be smooth.
ETH-
Take Rename function
A function has been added that allows you to change the names of takes. Follow the procedures below to do so.
1. On a take selection screen, select that take that you want to rename.
2. Touch the
menu (An been added to this pull-up menu).
3. Touch the
NAME
take name.)
MENU
button on the take selection screen to open a pull-up
EDIT NAME
EDIT NAME
screen. (On this
button, which is shown framed in red below, has
button in the pull-up menu to open the
TAKE NAME
screen, you can change the input
TAKE
6 TAS CAM H S-8
NOTE
When multiple takes are selected, you cannot use the
EDIT NAME
the pull-up menu.
4. Edit the take name.
5. Touch the
Enter
button on the dial to confirm the changed take name and return to the take selection screen.
TAKE NAME
screen or press the DATA
button in
HS-8
Rec Fn Stop Monitor function added
A Rec Fn Stop Monitor function has been added to the
SYSTEM SETUP
of the toring of channels that are armed for recording when the unit is stopped.
screen. This function allows you to disable input moni-
PREFERENCES
page
Monitor muting function added
A RecPause Monitor function that allows input monitoring during rec pause to be muted has been added to the
SETUP
screen
PREFERENCES
page of the
SYSTEM
Slate tone function added
A Slate Tone function has been added to the
SETUP
screen. This can be used to output a 1kHz sine wave at the reference
level on the channels that are armed for recording.
OUTPUT
page of the
MIXER
Receiving digital input signals that are in consumer format
The unit can now receive digital input signals that are in consumer format.
Clear function can now be executed using the SHIFT and BACKSPACE keys on an external keyboard
A function has been added when a character or number input screen is open that allows you to clear all the characters/numbers by pressing the BACK­SPACE key while pressing and holding the SHIFT key on an external keyboard. (Previously, on a number input screen, pressing the Esc key cleared input numbers, but this has been changed.)
Cursor can now be moved using the up and down arrow (2/x), HOME and END keys of an external keyboard
A function has been added that allows you to press the 2/x key on an exter­nal keyboard to move the cursor to the beginning/end of a line of characters when a character input screen is open.
Title display changes on the PROJECT screen
PROJECT
The
TAKE
screen title display now switches to
according to which list is displayed.
PROJECT, FOLDER
or
PROJECT key now moves up a level when the PROJECT screen is open
Now, if the PROJECT key is pressed while the the contents of the folder one level above the items shown currently will be displayed.
PROJECT
screen is open,
New pop-up message
Message Details and responses Remarks
Cannot Edit read­only file. Cannot set Mark point in read-only file.
--- Circle Take --­Did not Edit N
Take(s) that (is/are)
read-only.
This file has been set as read­only and cannot be edited. Marks cannot be added to a file that has been set as read-only
Editing a number (N) of takes that are set to read­only was not possible.
N = number of takes This appears when
“CIRCLE TAKE" is executed with a selec­tion that includes both read-only and read­writable takes.
NOTE
When the “LR 2mix” record function is on, the sine wave will be input on all channels along with the monitoring signals.
USER BITS Source setting function added
A USER BITS Source function that allows the type of timecode user bits recorded and output to be set has been added to the
I/O
page of the
SYNC T/C
screen.
Addition of take end time code display
End time code information (END T/C) has been added to the take information pop-up.
TAS CAM H S-8 7
HS-8
Addendum to the Owner’s Manual
Importing multiple mono files that have been recorded with another device as a single take
Follow the procedures below to import multiple mono files that have been recorded with another device to this unit as a single take.
NOTE
the unit to treat as a single take have the same sampling frequency, bit depth and audio length.
1. Name the mono files that you want to be recognized as a single take
using the following format.
[mono take name]_[2-digit track number].wav
Example:
Scene001-T001_01.wav Scene001-T001_02.wav Scene001-T001_03.wav Scene001-T001_04.wav Scene001-T001_05.wav Scene001-T001_06.wav Scene001-T001_07.wav Scene001-T001_08.wav
2. Copy the above files to the CF card by following the procedures in the
“Preparations before importing” section of “Importing files recorded by other devices” on page 4 of the HS-8 firmware v1.20 Instruction Manual.
3. Rebuild the folder by following the procedures in the “Preparing imported files
for use with this unit (rebuilding the folder)” section of “Importing files recorded by other devices” on page 4 of the HS-8 firmware v1.20 Instruction Manual.
8 TAS CAM H S-8
Printed in China
Loading...