Sylvania LC370SL8 Schematic

SUPPLEMENT
SERVICE MANUAL
This service manual shows only the differences between the model LC370SL8 and the original model LC370SS8. All other information is described in the service manual of the model LC370SS8.
37 COLOR LCD TELEVISION
LC370SL8
TABLE OF CONTENTS
Schematic Diagrams / CBA’s and Test Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Different parts from the original model (LC370SS8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

BLOCK DIAGRAMS

Power Supply Block Diagram
AMP+13V
P-ON+9V
+9V REG
Q637
Q801
Q644
TO SYSTEM
CONTROL
BLOCK
DIAGRAM
P-ON-H
AL+3.3V
CN301
+5V/+12V-LCD 2,3
AL+3.3V 4
P-ON+5V 6,7
TO DIGITAL
MAIN CBA UNIT
(CN3010)
14-16
10-12
+4V
+2.5V
P-ON+9V 8
TO DIGITAL
MAIN CBA UNIT
(CN3025)
CN1
+2.5V 4,5
D+1.0V-VDDC 1,2
+15V 18
+35V 20
+2.5V-UNDER 3
DIGITAL SUB CBA
Q1,Q2,Q3
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
NOTE:
The voltage for parts in hot circuit is measured using
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
hot GND as a common terminal.
SW +13V
Q639,Q640
4A/125V
16
15
T601
4
CN601
HOT-GND 3
ACL 1
3
1
CN501
Q635
SW +5V
Q636
REG
SHUNT
Q631
Q633
COLD
23
REG
+3.3V
IC637
JS632
13
12
11
6
7
Q632
JS612
Q643
IC603
14
3 2
Q638
Q641
Q650
10
9
14
2
HOT
SWITCHING
Q601
BRIDGE
RECTIFIER
D502 - D505
L502
LINE
LINE
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F501) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
L503
F501
4A/125V
HOT CIRCUIT. BE CAREFUL.
AC501
AC CORD
HOT
FILTER
FILTER
ACL
HOT-GND
TO INVERTER
4A 125V
INVERTER CBA
BLOCK DIAGRAM
1-1
CONTROL
Q602
SWITCHING
POWER SUPPLY CBA
A71G1BLP

SCHEMATIC DIAGRAMS / CBA’S AND TEST POINTS

Standard Notes
WARNING
Many electrical and mechanical parts in this chassis have special characteristics. These characteristics often pass unnoticed and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts that have these special safety characteristics are identified in this manual and its supplements; electrical components having such features are identified by the mark “#” in the schematic diagram and the parts list. Before replacing any of these components, read the parts list in this manual carefully. The use of substitute replacement parts that do not have the same safety characteristics as specified in the parts list may create shock, fire, or other hazards.
Notes:
1. Do not use the part number shown on these drawings for ordering. The correct part number is shown in the parts list, and may be slightly different or amended since these drawings were prepared.
2. All resistance values are indicated in ohms (K = 10
3. Resistor wattages are 1/4W or 1/6W unless otherwise specified.
4. All capacitance values are indicated in µF (P = 10
5. All voltages are DC voltages unless otherwise specified.
3
, M = 106).
-6
µF).
2-1 LC4N_SC
Loading...
+ 7 hidden pages