Supermicro X11SSV-M4F operation manual

Page 1
X11SSV-M4F
USER’S MANUAL
Revision 1.0
Page 2
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note:
For the most up-to-date version of this manual, please see our website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/ or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL Super Micro Computer, Inc. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”.
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical
systems whose failure to perform be reasonably expected to result in signicant injury or loss of life or catastrophic
property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Manual Revision 1.0
Release Date: November 23, 2016
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this
document. Information in this document is subject to change without notice. Other products and companies referred
to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2016 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Page 3
Preface
Preface
About This Manual
This manual is written for system integrators, IT technicians and knowledgeable end users. It provides information for the installation and use of the X11SSV-M4F motherboard.
About This Motherboard
Built upon the functionality and capability of Intel's C236 chipset and onboard Intel Xeon E3­1500 v5 series BGA processor, the X11SSV-M4F motherboard provides superior graphics capability and system performance while keeping a small form-factor and power consumption to a minimum. Based on the 14nm micro-architecture process, the motherboard offers up to 32GB of fast DDR4 SO-DIMM in 2 slots, 12V DC input, IPMI, USB3.0, M.2, mini PCI-E, PCI-E 3.0 x16, and SATA 3.0 (6Gbps). The processor also provides GT4e Iris Pro graphics for advanced media hardware acceleration (VHD) and the inclusion of eDRAM for increased
system efciency. Please note that this motherboard is intended to be installed and serviced
by professional technicians only. For processor/memory updates, please refer to our website at http://www.supermicro.com/products/.
Conventions Used in the Manual
Special attention should be given to the following symbols for proper installation and to prevent
damage done to the components or injury to yourself:
Warning! Indicates important information given to prevent equipment/property damage
or personal injury.
Warning! Indicates high voltage may be encountered when performing a procedure.
Important: Important information given to ensure proper system installation or to
relay safety precautions.
Note: Additional Information given to differentiate various models or provides infor­mation for correct system setup.
3
Page 4
X11SSV-M4F User's Manual
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Website: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Website: www.supermicro.nl
Asia-Pacic
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Website: www.supermicro.com.tw
4
Page 5
Preface
Table of Contents
Chapter 1 Introduction
1.1 Checklist ...............................................................................................................................8
Quick Reference ...............................................................................................................11
Quick Reference Table ......................................................................................................12
Motherboard Features .......................................................................................................14
1.2 Processor and Chipset Overview .......................................................................................18
1.3 Special Features ................................................................................................................18
Recovery from AC Power Loss .........................................................................................18
1.4 System Health Monitoring ..................................................................................................19
Onboard Voltage Monitors ................................................................................................19
Fan Status Monitor with Firmware Control .......................................................................19
Environmental Temperature Control .................................................................................19
System Resource Alert......................................................................................................19
1.5 ACPI Features ....................................................................................................................20
1.6 Power Supply .....................................................................................................................20
1.7 Super I/O ............................................................................................................................20
1.8 Advanced Power Management ..........................................................................................21
Intel® Intelligent Power Node Manager (IPNM).................................................................21
Management Engine (ME) ................................................................................................21
Chapter 2 Installation
2.1 Static-Sensitive Devices .....................................................................................................22
Precautions .......................................................................................................................22
Unpacking .........................................................................................................................22
2.2 Motherboard Installation .....................................................................................................23
Tools Needed ....................................................................................................................23
Location of Mounting Holes ..............................................................................................23
Installing the Motherboard.................................................................................................24
2.3 Memory Support and Installation .......................................................................................25
Memory Support ................................................................................................................25
SO-DIMM Module Population Sequence ..........................................................................25
SO-DIMM Installation ........................................................................................................26
5
Page 6
X11SSV-M4F User's Manual
SO-DIMM Removal ...........................................................................................................26
2.4 Rear I/O Ports ....................................................................................................................27
2.5 Front Control Panel ............................................................................................................31
2.6 Connectors .........................................................................................................................35
Power Connections ...........................................................................................................35
Headers .............................................................................................................................37
2.7 Jumper Settings .................................................................................................................45
How Jumpers Work ...........................................................................................................45
2.8 LED Indicators ....................................................................................................................50
Chapter 3 Troubleshooting
3.1 Troubleshooting Procedures ..............................................................................................52
Before Power On ..............................................................................................................52
No Power ..........................................................................................................................52
No Video ...........................................................................................................................53
System Boot Failure .......................................................................................................53
Memory Errors ..................................................................................................................53
Losing the System's Setup Conguration .........................................................................54
When the System Becomes Unstable ..............................................................................54
3.2 Technical Support Procedures ...........................................................................................56
3.3 Frequently Asked Questions ..............................................................................................57
3.4 Battery Removal and Installation .......................................................................................58
Battery Removal ................................................................................................................58
Proper Battery Disposal ....................................................................................................58
Battery Installation .............................................................................................................58
3.5 Returning Merchandise for Service ....................................................................................59
Chapter 4 BIOS
4.1 Introduction .........................................................................................................................60
Starting the Setup Utility ...................................................................................................60
4.2 Main Setup .........................................................................................................................61
4.3 Advanced Setup Congurations .........................................................................................63
4.4 Event Logs .........................................................................................................................85
4.5 IPMI ....................................................................................................................................87
4.6 Security ...............................................................................................................................90
6
Page 7
Preface
4.7 Boot ....................................................................................................................................93
4.8 Save & Exit .........................................................................................................................95
Appendix A BIOS Codes
Appendix B Software Installation
B.1 Installing Software Programs .............................................................................................99
B.2 SuperDoctor® 5 .................................................................................................................100
Appendix C Standardized Warning Statements
Battery Handling ..............................................................................................................101
Product Disposal .............................................................................................................103
Appendix D UEFI BIOS Recovery
7
Page 8
X11SSV-M4F User's Manual
Chapter 1
Introduction
Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and performance.
Please check that the following items have all been included with your motherboard. If anything listed here is damaged or missing, contact your retailer. The following items are included in the retail box:
1.1 Checklist
Main Parts List (Included in Retail Box)
Description Part Number Quantity
Supermicro Motherboard X11SSV-M4F 1
SATA Cables CB-0044L 4
I/O Shield MCP-260-00056-1N 1
Important Links
For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server.
Supermicro product manuals: http://www.supermicro.com/support/manuals/
Product drivers and utilities: ftp://ftp.supermicro.com
Product safety info: http://www.supermicro.com/about/policies/safety_information.cfm
If you have any questions, please contact our support team at: support@supermicro.com
This manual may be periodically updated without notice. Please check the Supermicro website
for possible updates to the manual revision level.
8
Page 9
Figure 1-1. X11SSV-M4F Motherboard Image
Chapter 1: Introduction
Note: All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual. The motherboard you received may or may not look exactly the same as the graphics shown in this manual.
9
Page 10
X11SSV-M4F User's Manual
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPAC1
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
AUDIO
1
JPCIE1 x16
SRW2
Figure 1-2. X11SSV-M4F Motherboard Layout
(not drawn to scale)
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
JVRM1
SRW1
SRW3
JVRM2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
DVI-A
BT1
LAN3/4
A
C
LED1
Intel
JI2C2:
Aspeed
I350-AM2
AST2400
m-PCIE
DIMMB1
COM1
USB1/2
JP1
USB9
JPW2
JPW1
JPI2C1
JD1
JPME1
JBR1
JPUSB1
JL1
JGPIO1
FAN3
J17
1
J16
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
NIC3
1
M.2
I-SATA2
I-SATA3
I-SGPIO1
SRW4
I-SATA4
JTPM1
JBT1
Intel CM236
USB7/8
USB5/6
LED2
A
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR LED
CPU
FAN1
FAN2
PWR
OH
HDD LED
PWR
NIC
NIC
RST
FF
FAIL
2
ON
1
Note: Components not documented are for internal testing only.
10
Page 11
Quick Reference
Chapter 1: Introduction
JPAC1
SRW1
JI2C1
JI2C1
JSMB1
SRW2
JPG1
SRW3
JWD1
JBT1
SRW4
JD1
JPCIE1 x16
JPME1
JBR1
M.2 JPUSB1 I-SATA2 I-SATA1
JSD1 JSD2
JGPIO1
FAN3
JL1
Notes:
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
JVRM1
AUDIO
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
JPAC1
JPCIE1 x16
JSD1 JSD2
JGPIO1
FAN3
J17
1
JL1
J16
J17
I-SGPIO1
JVRM2
AUDIO
1
SRW1
SRW2
SRW3
I-SATA1
SATA DOM
+POWER
I-SATA3
NIC3
1
I-SGPIO1
J16
I-SATA3
I-SATA4
JVRM1
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
M.2
I-SATA2
JVRM2
JI2C2:
DVI-A
DVI-A
Aspeed AST2400
SRW4
I-SATA4
JTPM1
JTPM1
LED1
BT1
BT1
JBT1
Intel CM236
USB7/8
USB5/6
LED2
A
LED2
USB5/6
LAN3/4
LAN3/4
A
C
LED1
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL 2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
JF1
JF1
USB7/8
m-PCIE
LAN1/2
Intel I350-AM2
m-PCIE
DIMMB1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
RECOVERY
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
PWR
HDD
NIC
NIC
LED
LED
2
1
DIMMB1
LAN1/2
OH
PWR
FF
FAIL
JIPMB1
JIPMB1
DIMMA1
PWR
RST
ON
DIMMA1
KB/MS
USB3/4
USB3/4
COM1
USB1/2
COM1
USB1/2
CPU
USB9
USB9
JPW2
JPI2C1
JPW1
JP1
JPW2
JPW1
JPI2C1
JP1
FAN1
FAN1
CPU
FAN2
FAN2
See Chapter 2 for detailed information on jumpers, I/O ports, and JF1 front panel con-
nections.
" " indicates the location of Pin 1.
Jumpers/LED indicators not indicated are used for testing only.
Use only the correct type of onboard CMOS battery as specied by the manufacturer. Do
not install the onboard battery upside down to avoid possible explosion.
11
Page 12
X11SSV-M4F User's Manual
Quick Reference Table
Jumper Description Default Setting
JBR1 BIOS Recovery Pins 1-2 (Normal)
JBT1 CMOS Clear Open (Normal)
JI2C1/JI2C2 SMB to PCI-E Slots Enable/Disable Pins 2-3 (Disabled)
JPAC1 Audio Enable Pins 1-2 (Enabled)
JPG1 VGA Enable/Disable Pins 1-2 (Enabled)
JPME1 ME Recovery Pins 1-2 (Normal)
JPUSB1 USB Wake Up Pins 2-3 (Disabled)
JVRM1 VRM SMB Clock (to BMC or PCH) Pins 1-2 (Normal)
JVRM2 VRM SMB Data (to BMC or PCH) Pins 1-2 (Normal)
JWD1 Watch Dog Pins 1-2 (Reset)
LED Description Status
LED1 BMC Heartbeat Blinking Green: BMC Normal
LED2 Power LED Solid Green: Power On
Connector Description
AUDIO Front Panel Audio Header
BT1 Onboard Battery
COM1 COM Port (in RJ45)
DVI-A Digital Video Interface (Analog Output Only)
FAN1 ~ FAN3 System/CPU Fan Headers (FAN1: CPU Fan)
I-SATA1 ~ I-SATA4 Intel® PCH SATA 3.0 Ports
I-SGPIO1 Serial Link General Purpose I/O Header
J16 NIC3 Activity LED Header
J17 NIC4 Activity LED Header
JD1 Speaker Header
JF1 Front Control Panel Header
JGPIO1 General Purpose I/O Header
JIPMB1 4-pin External I2C Header (for an IPMI card)
JL1 Chassis Intrusion Header
JP1 4-pin Power Connector for HDD
JPCIE1 x16 CPU PCI-E 3.0 X16 Slot
JPI2C1 Power Supply SMBus I2C Header
JPW1 24-pin ATX Power Connector
JPW2
JSD1/JSD2 SATA DOM Power Connectors
JSMB1 System Management Bus Header
12V 8-pin CPU Power Connector (To provide alternative power for special enclosure
when the 24-pin ATX power is not in use.)
12
Page 13
Connector Description
JTPM1 Trusted Platform Module/Port 80 Connector
LAN1 ~ LAN4 LAN (RJ45) Ports
M.2 M.2 Slot
m-PCIE Mini-PCIE Slot
SRW1/SRW3
SRW2/SRW4
USB1/2, USB3/4 Back panel USB 3.0 Ports
USB5/6 Front Access USB 2.0 Header
USB7/8 Front Access USB 2.0 Header
USB9 USB Type A Header
M.2 Holding Screws
Mini-PCIE Holding Screws
Chapter 1: Introduction
13
Page 14
X11SSV-M4F User's Manual
Motherboard Features
Motherboard Features
CPU
Onboard Intel Xeon E3-1500 v5 series processor in BGA socket
Memory
Supports up to 32GB of ECC SO-DIMM, DDR4-2133MHz, in two slots. (DDR4-2400 modules can be used but will operate
at 2133MHz)
DIMM Size
4GB, 8GB, 16GB
Chipset
Intel® PCH C236
Expansion Slots
One (1) PCI Express 3.0 X16 slot
Network
Intel I219LM Gigabit Ethernet PHY (LAN1)
Intel I210-AT Gigabit Ethernet Controller (LAN2): IPMI Shared LAN Port
Intel I350-AM2 Dual Gigabit Ethernet Controller (LAN3/4)
Graphics
Graphics controller via ASpeed 2400 BMC (DVI-A - Analog Output Only)
Intel Iris Pro P580 for VHD
I/O Devices
COM Port (in RJ45 port) One (1) COM port in the rear I/O panel (in RJ45 port)
SATA Ports • Four (4) SATA 3.0 ports supported by Intel PCH (I-SATA1-4)
M.2 Port
m-PCIE Port One (1) Mini-PCIE port, supports mSATA and PCIE devices
Peripheral Devices
Four (4) USB 3.0 ports on the rear I/O panel (USB1/2, USB3/4)
Four (4) USB 2.0 ports in two (2) internal headers (USB5/6, USB7/8)
One (1) Type-A USB 2.0 connector (USB9)
One (1) M.2 PCIE 3.0 x4 port, supports SATA, AHCI, and NVMe M.2 storage
devices in 2242 or 2282 form factor
Note: The table above is continued on the next page.
14
Page 15
Chapter 1: Introduction
Motherboard Features
BIOS
128Mb SPI AMI BIOS
ACPI 3.0 or later, SMBIOS 2.7 or later, Plug-and-Play (PnP), RTC (Real Time Clock) wakeup
Power Management
ACPI power management
Power button override mechanism
Power-on mode for AC power recovery
Wake-On-Ring
Wake-On-LAN
System Health Monitoring
Onboard voltage monitoring for +3.3V, 3.3V standby, +5V, +5V standby, +12V, VBAT, HT, Memory, PCH Temp., System
Temp., Memory Temp.
CPU switching phase voltage regulator
CPU Thermal Trip support
CPU Thermal Design Power (TDP) support of up to 65W (See Note 1 on next page.)
®
SM Flash UEFI BIOS
Fan Control
Fan status monitoring via IPMI connections
Single cooling zone
Low-noise fan speed control
Pulse Width Modulation (PWM) fan control
System Management
Trusted Platform Module (TPM) support
PECI (Platform Environment Control Interface) 2.0 support
System resource alert via SuperDoctor® 5
SuperDoctor® 5, Watch Dog, NMI
Chassis intrusion header and detection
LED Indicators
Power
BMC Heartbeat
Dimensions
6.7" (L) x 6.7" (W) (170.18 mm x 170.18 mm)
Note: The table above is continued on the next page.
15
Page 16
X11SSV-M4F User's Manual
Note 1: The CPU maximum thermal design power (TDP) is subject to chassis and
heatsink cooling restrictions. For proper thermal management, please check the chas-
sis and heatsink specications for proper CPU TDP sizing.
Note 2: For IPMI conguration instructions, please refer to the Embedded IPMI Con­guration User's Guide available at http://www.supermicro.com/support/manuals/.
Note 3: It is strongly recommended that you change BMC log-in information upon initial system power-on. The manufacture default username is ADMIN and the password is
ADMIN. For proper BMC conguration, please refer to http://www.supermicro.com/ products/info/les/IPMI/Best_Practices_BMC_Security.pdf
16
Page 17
PCIe x16 SLOT
PCIe3.0_x16
8.0GT/s
Figure 1-3.
System Block Diagram
INTEL BGA 1440
DDI 3
DDI E
DDI 2
DDI 1
x4 DMI 5GT/s
SVID
DDR4 (CHA)
2133MHz
DDR4 (CHB)
2133MHz
Chapter 1: Introduction
IMVP8
PVCC_CPU ,VCCSA
IMVP8
PVCC_GT ,PVCC_GTX
DIMMA1
SODIMM,Vertical type
DIMMB1
M.2 2280 SSD or SATA
8.5mm
4 X SATA-III
Note: I-SATA1/2=SuperDOM Connector
4 X USB 3.0 Rear
4 X USB 2.0 FRONT
1 X USB A-type
audio header
Realtek ALC888S-VD2
REAR LAYOUT X11SSV-M4F
COM
PCIe3.0_x4
8GT/s
SATA-III
6Gb/s
SATA-III
6Gb/s
SGPIO
USB3.0 5Gbps
USB2.0 480Mbps
USB2.0 480Mbps
AZALIA
DVI-A
PCIE[12:9]
SATA[0]/PCIE9
SATA[2/3/4/5]
USB[1/2/3/4]
USB[7/8/11/12]
USB[9]
SPI
FLASH SPI 128Mb
Intel
PCH-H C236
GPIO Expander
PCIE[7]
USB[10]
SATA[1]/PCIE14
PCIE[5]
PCIE[6]
PCIE[1-4]
PCIE[8]
LPC
PCIe3.0_x1
8GT/s
SATA-III
6Gb/s
PCIe3.0_x1
2.5GT/s PCIe3.0_x1
8GT/s
PCIe3.0_x4
8GT/s
PCIe3.0_x1
2.5GT/s
LPC
Mini PCI-E SLOT Shared with mSATA
9.0mm
GLAN1
I219LM
GLAN2
I210-AT
GLAN3/4
I350-AM2
AST2400A1
BMC VGA
TPM1.2 Header
RJ45
RJ45
RJ45
RJ45
DVI-A CNT
COM1 TO RJ45
NCSI
NCSI
Note: This is a general block diagram and may not exactly represent the features on
your motherboard. See the previous pages for the actual specications of your moth­erboard.
17
Page 18
X11SSV-M4F User's Manual
1.2 Processor and Chipset Overview
Built upon the functionality and capability of the Intel Xeon E3-1500 v5 series processor (BGA Socket) and the Intel C236, the X11SSV-M4F motherboard offers maximum I/O expandability,
energy efciency, and data reliability in a 14-nm process architecture, and is optimized for
VHD, webhosting, media streaming, or cloud-computing platforms.
With support of the new Intel microarchitecture 14 nm process technology, the X11SSV-M4F drastically increases system performance for a multitude of server applications.
The Intel Xeon E3-1500 v5 and PCH C236 platform supports the following features:
ACPI Power Management Revision 4.0a
Intel® Turbo Boost Technology 2.0 Power Monitoring/Power Control, Turbo Time Parameter
(TAU), and Platform Power Control
Intel SpeedStep Technology
Adaptive Thermal Management/Monitoring
PCI-E 3.0, SATA 3.0 w/transfer rates of up to 6 Gb/s, xHCI USB w/SuperSpeed 3.0
System Management Bus (SMBus) Specication, Version 2.0
Integrated Sensor Hub (ISH)
Intel Trusted Execution Technology (Intel TXT)
Intel Rapid Storage Technology
Intel Virtualization Technology for Directed I/O (Intel VT-d)
1.3 Special Features
This section describes the health monitoring features of the X11SSV-M4F motherboard. The motherboard has an onboard System Hardware Monitor chip that supports system health monitoring.
Recovery from AC Power Loss
The Basic I/O System (BIOS) provides a setting that determines how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off (in which case you must press the power switch to turn it back on), or for it to automatically return to the power-on state. See the Advanced BIOS Setup section for this setting. The default setting is Last State.
18
Page 19
Chapter 1: Introduction
1.4 System Health Monitoring
This section describes the health monitoring features of the X11SSV-M4F motherboard. The motherboard has an onboard Baseboard Management Controller (BMC) chip that supports system health monitoring. Once a voltage becomes unstable, a warning is given or an error
message is sent to the screen. The user can adjust the voltage thresholds to dene the
sensitivity of the voltage monitor.
Onboard Voltage Monitors
The onboard voltage monitor will continuously scan crucial voltage levels. Once a voltage becomes unstable, it will give a warning or send an error message to the screen. Users can
adjust the voltage thresholds to dene the sensitivity of the voltage monitor. Real time readings
of these voltage levels are all displayed in BIOS.
Fan Status Monitor with Firmware Control
The system health monitor embedded in the BMC chip can check the RPM status of the cooling fans. The CPU and chassis fans are controlled via lPMI.
Environmental Temperature Control
System Health sensors in the BMC monitor the temperatures and voltage settings of onboard processors and the system in real time via the IPMI interface. Whenever the temperature of
the CPU or the system exceeds a user-dened threshold, system/CPU cooling fans will be
turned on to prevent the CPU or the system from overheating.
Note: To avoid possible system overheating, please be sure to provide adequate air-
ow to your system.
System Resource Alert
This feature is available when used with SuperDoctor 5®. SuperDoctor 5 is used to notify the
user of certain system events. For example, you can congure SuperDoctor 5 to provide you
with warnings when the system temperature, CPU temperatures, voltages and fan speeds
go beyond a predened range.
19
Page 20
X11SSV-M4F User's Manual
1.5 ACPI Features
ACPI stands for Advanced Conguration and Power Interface. The ACPI specication denes a exible and abstract hardware interface that provides a standard way to integrate power
management features throughout a computer system including its hardware, operating system and application software. This enables the system to automatically turn on and off peripherals such as network cards, hard disk drives and printers.
In addition to enabling operating system-directed power management, ACPI also provides a generic system event mechanism for Plug and Play and an operating system-independent
interface for conguration control. ACPI leverages the Plug and Play BIOS data structures
while providing a processor architecture-independent implementation that is compatible with Windows 8 and Windows 2012/R2 operating systems.
1.6 Power Supply
As with all computer products, a stable power source is necessary for proper and reliable operation. It is even more important for processors that have high CPU clock rates. In areas
where noisy power transmission is present, you may choose to install a line lter to shield
the computer from noise. It is recommended that you also install a power surge protector to help avoid problems caused by power surges.
1.7 Super I/O
The Super I/O (ASpeed AST2400 chip) includes a data separator, write pre-compensation circuitry, decode logic, data rate selection, a clock generator, drive interface control logic and interrupt and DMA logic. The wide range of functions integrated onto the Super I/O greatly
reduces the number of components required for interfacing with oppy disk drives.
The Super I/O provides one high-speed, 16550 compatible serial communication ports (UARTs). Each UART includes a 16-byte send/receive FIFO, a programmable baud rate generator, complete modem control capability and a processor interrupt system. It provides legacy speed with baud rate of up to 115.2 Kbps as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which support higher speed modems.
The Super I/O provides functions that comply with ACPI (Advanced Conguration and Power
Interface), which includes support of legacy and ACPI power management through a SMI or SCI function pin. It also features auto power management to reduce power consumption.
The IRQs, DMAs and I/O space resources of the Super I/O can be exibly adjusted to meet
ISA PnP requirements, which support ACPI and APM (Advanced Power Management).
20
Page 21
Chapter 1: Introduction
1.8 Advanced Power Management
The following new advanced power management features are supported by the motherboard.
Intel® Intelligent Power Node Manager (IPNM)
Available when the Supermicro Power Manager (SPM) is installed, Intel's Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power
management for maximum energy efciency. Although IPNM Specication Version 2.0/3.0
is supported by the BMC (Baseboard Management Controller), your system must also have
IPNM-compatible Management Engine (ME) rmware installed to use this feature.
Note: Support for IPNM 2.0/3.0 support is dependent on the power supply used in the system.
Management Engine (ME)
The Management Engine, which is an ARC controller embedded in the IOH (I/O Hub), provides Server Platform Services (SPS) to your system. The services provided by SPS are different from those provided by the ME on client platforms.
21
Page 22
X11SSV-M4F User's Manual
Chapter 2
Installation
2.1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent damage to your motherboard, it is important to handle it very carefully. The following measures are generally
sufcient to protect your equipment from ESD.
Precautions
Use a grounded wrist strap designed to prevent static discharge.
Touch a grounded metal object before removing the board from the antistatic bag.
Handle the board by its edges only; do not touch its components, peripheral chips, memory
modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the motherboard and peripherals back into their antistatic bags when not in use.
For grounding purposes, make sure that your chassis provides excellent conductivity be-
tween the power supply, the case, the mounting fasteners and the motherboard.
Use only the correct type of CMOS onboard battery as specied by the manufacturer. Do
not install the CMOS battery upside down, which may result in a possible explosion.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static damage. When unpacking the motherboard, make sure that the person handling it is static protected.
22
Page 23
Chapter 2: Installation
2.2 Motherboard Installation
All motherboards have standard mounting holes to t different types of chassis. Make sure
that the locations of all the mounting holes for both the motherboard and the chassis match. Although a chassis may have both plastic and metal mounting fasteners, metal ones are highly recommended because they ground the motherboard to the chassis. Make sure that the metal standoffs click in or are screwed in tightly.
Philips Screwdriver (1)
Tools Needed
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
JPAC1
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
JGPIO1
FAN3
JL1
J17
1
J16
AUDIO
1
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
NIC3
1
JVRM1
SRW1
SRW3
I-SATA3
I-SGPIO1
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1:
WATCH DOG 1-2:RST 2-3:NMI
M.2
I-SATA2
JVRM2
JI2C2:
DVI-A
I-SATA4
JTPM1
Aspeed AST2400
SRW4
Philips Screws (4)
BT1
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
Intel CM236
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP
LED2
A
1-2:ENABLE 2-3:DISABLE
JF1
PWR LED
USB7/8
USB5/6
HDD LED
DIMMB1
NIC
1
Standoffs (4) Only if Needed
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
PWR
OH
PWR
NIC
RST
FF
FAIL
2
ON
COM1
USB1/2
USB9
JP1
JPW2
JPW1
JPI2C1
CPU
FAN1
FAN2
Location of Mounting Holes
Note: 1) To avoid damaging the motherboard and its components, please do not use
a force greater than 8 lb/inch on each mounting screw during motherboard installation.
2) Some components are very close to the mounting holes. Please take precautionary measures to avoid damaging these components when installing the motherboard to the chassis.
23
Page 24
X11SSV-M4F User's Manual
Installing the Motherboard
1. Install the I/O shield into the back of the chassis.
2. Locate the mounting holes on the motherboard. See the previous page for the location.
3. Locate the matching mounting holes on the chassis. Align the mounting holes on the motherboard against the mounting holes on the chassis.
4. Install standoffs in the chassis as needed.
5. Install the motherboard into the chassis carefully to avoid damaging other motherboard components.
6. Using the Phillips screwdriver, insert a Phillips head #6 screw into a mounting hole on the motherboard and its matching mounting hole on the chassis.
7. Repeat Step 5 to insert #6 screws into all mounting holes.
8. Make sure that the motherboard is securely placed in the chassis.
Note: Images displayed are for illustration only. Your chassis or components might look different from those shown in this manual.
24
Page 25
Chapter 2: Installation
2.3 Memory Support and Installation
Note: Check the Supermicro website for recommended memory modules.
Important: Exercise extreme care when installing or removing DIMM modules to pre-
vent any possible damage.
Memory Support
The X11SSV-M4F supports up to 32GB of DDR4 ECC SO-DIMM 2133 MT/s. Populating these DIMM slots with a pair of memory modules of the same type and size will result in interleaved memory, which will improve memory performance.
SO-DIMM Module Population Sequence
When installing memory modules, the DIMM slots must be populated in the following order: DIMMA1 and then DIMMB1.
Towards the CPU
DIMMA1
DIMMB1
Towards the edge of the motherboard
Note: Be sure to use memory modules of the same type and speed. Mixing of memory modules of different types and speeds is not allowed.
25
Page 26
X11SSV-M4F User's Manual
SO-DIMM Installation
1. Insert SO-DIMM modules in the following order: DIMMA1 and then DIMMB1. For the system to work properly, please use memory modules of the same type and speed.
2. Position the SO-DIMM module's bottom key
so it aligns with the receptive point on the slot. Take note of the module's side notches and the locking clips on the socket.
JPAC1
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
JL1
Align
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
BT1
AUDIO
1
JVRM1
JPCIE1 x16
SRW1
SRW2
SRW3
M.2
JSD1JSD2
JGPIO1
I-SATA1
I-SATA2
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
J16
1
I-SGPIO1
A
JVRM2
C
LED1
JI2C1/
JI2C2:
Aspeed
1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1
AST2400
JWD1: WATCH DOG 1-2:RST 2-3:NMI
SRW4
JBT1
Intel CM236
USB7/8
USB5/6
I-SATA4
LED2
A
JTPM1
LAN3/4
Intel I350-AM2
DESIGNED IN USA
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL 2-3:ME JBR1 1-2:NORMAL 2-3:BIOS JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
KB/MS
USB3/4
LAN1/2
m-PCIE
DIMMB1
REV:1.00
X11SSV-M4F
RECOVERY
RECOVERY
OH
PWR
PWR
HDD
NIC
NIC
FF
FAIL
LED
LED
2
1
COM1 USB1/2
JIPMB1
DIMMA1
PWR
RST
ON
JP1
USB9
JPW2
JPW1
JPI2C1
CPU
FAN1
FAN2
3. Insert the SO-DIMM module straight down.
4. Press down until the module locks into place. The side clips will automatically secure the SO-DIMM module, locking it into place
SO-DIMM Removal
1. Gently push the side clips near both ends away from the module. Pull the SO-DIMM module up to remove it from the slot.
26
Page 27
Chapter 2: Installation
2.4 Rear I/O Ports
See Figure 2-2 below for the locations and descriptions of the various I/O ports on the rear of the motherboard.
JPAC1:AUDIO 1-2:ENABLE
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1:
WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
1
J16
1
+POWER
JVRM1
SRW1
SRW3
M.2
I-SATA2
I-SATA3
NIC3
I-SGPIO1
JPAC1
JD1
JL1
DIMMB1
NIC
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
2
ON
COM1 USB1/2
USB9
JP1
JPW2
JPW1
JPI2C1
CPU
FAN1
FAN2
Figure 2-1. I/O Port Locations and Denitions
1
6
4
2
5
7
3
8
9
10
Rear I/O Ports
# Description # Description
1. COM Port 6. LAN2
2. USB2 7. LAN1
3 USB1 8 LAN4
4 USB4 9 LAN3
5. USB3 10 DVI-A Port
27
Page 28
X11SSV-M4F User's Manual
DVI-A Port
One DVI-A port (Analog Output Only) is located next to the LAN ports on the I/O back panel. This port provides analog display from the BMC graphics.
COM Port
There is one COM port (COM1) in an RJ45 sokcet on the I/O back panel.
COM Port
Pin Denitions
Pin 1
COM Port 1
Pin# Denition Pin# Denition
1 RTS 5 GND
2 DTR 6 RXD
3 TXD 7 DSR
4 GND 8 CTS
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
1
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
BT1
LAN3/4
A
C
LED1
Intel
USB7/8
USB5/6
LED2
A
I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
JI2C2:
Aspeed AST2400
SRW4
Intel CM236
I-SATA4
JTPM1
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
1
J16
1
+POWER
NIC3
JVRM1
SRW1
SRW3
M.2
I-SATA2
I-SATA3
I-SGPIO1
JPAC1
JD1
JL1
DIMMB1
NIC
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
2
ON
COM1 USB1/2
2
1. DVI-A Port
2. COM1
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
28
Page 29
Chapter 2: Installation
LAN Ports
There are four 1GbE LAN ports (LAN1~4) on the I/O back panel. These ports accepts RJ45
type cables. Refer to the table below for pin denitions.
LAN Port
Pin Denitions
Pin# Denition Pin# Denition
1 TX_D1+ 5 BI_D3-
2 TX_D1- 6 RX_D2-
3 RX_D2+ 7 BI_D4+
4 BI_D3+ 8 BI_D4-
IPMI Port
LAN2 is also a shared IPMI LAN port, providing IPMI access along with network connectivity.
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
1. LAN1
LAN2 (shared with IPMI LAN port)
2. LAN3/4
12
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
JVRM1
SRW1
SRW3
M.2
I-SATA2
I-SATA3
NIC3
I-SGPIO1
JPAC1
JD1
JL1
DIMMB1
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
NIC
RST
FF
FAIL
2
ON
COM1
USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
29
Page 30
X11SSV-M4F User's Manual
X11SSV-M4F
REV:1.00
DESIGNED IN USA
JBT1
USB7/8
JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JD1: 4-7:SPEAKER
1-2:NORMAL
JPME1:
1-3:PWR LED
JBR1 1-2:NORMAL
RECOVERY
2-3:ME
RECOVERY
2-3:BIOS
m-PCIE
DIMMA1
DIMMB1
SRW4
Aspeed AST2400
Intel I350-AM2
Intel CM236
Universal Serial Bus (USB) Ports
There are four USB 3.0 ports (USB1/2 and USB3/4) on the I/O back panel. The motherboard also provides four USB2.0 connections via USB headers (USB5/6 and USB7/8). The USB9 header is USB Type A. The onboard headers can be used to provide front side USB access with a cable (not included).
10
Front Panel USB 2.0
9
1
Pin# Denition Pin# Denition
1 +5V 2 +5V
3 USB_PN2 4 USB_PN3
5 USB_PP2 6 USB_PP3
2
7 Ground 8 Ground
9 Key 10 Ground
Header Pin Denitions
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
AUDIO
1
JPAC1
JPCIE1 x16
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
SRW2
JD1
JSD1 JSD2
JGPIO1
I-SATA1
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
JL1
J16
1
I-SGPIO1
SRW1
JVRM1
SRW3
I-SATA2
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
2
1
DVI-A
BT1
LAN3/4
A
C
LED1
Intel
USB7/8
USB5/6
LED2
A
I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP
4
1-2:ENABLE 2-3:DISABLE
3
JF1
PWR
HDD
LED
LED
JI2C2:
Aspeed AST2400
SRW4
Intel CM236
I-SATA4
JTPM1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
DIMMB1
OH
PWR
PWR
NIC
NIC
RST
FF
FAIL
2
ON
1
COM1 USB1/2
CPU
30
USB9
5
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. USB1/2
2. USB3/4
3. USB5/6
4. USB7/8
5. USB9
Page 31
Chapter 2: Installation
Re
D
2.5 Front Control Panel
JF1 contains header pins for various buttons and indicators that are normally located on a
control panel at the front of the chassis. These connectors are designed specically for use with Supermicro chassis. See the gure below for the descriptions of the front control panel
buttons and LED indicators.
JPAC1:AUDIO 1-2:ENABLE
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
2-3:DISABLE
DVI-A
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
JBT1
C
LED1
A
JF1
LAN3/4
Intel I350-AM2
m-PCIE
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
PWR
HDD
LED
LED
NIC
AUDIO
1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
NIC3
SRW1
SRW3
I-SATA3
I-SGPIO1
JVRM1
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1
JWD1: WATCH DOG 1-2:RST 2-3:NMI
M.2
I-SATA2
JPAC1
JD1
JGPIO1
JL1
DIMMB1
NIC
2
1
OH FF
LAN1/2
PWR FAIL
RST
JIPMB1
DIMMA1
PWR ON
KB/MS
USB3/4
COM1
USB1/2
USB9
JP1
JPW2
JPW1
JPI2C1
CPU
FAN1
FAN2
Figure 2-2. JF1 Header Pins
1
PWR
set
Power Button
Reset Button
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
15 16
31
2
Ground
Ground
PWR Fail LED
OH/Fan Fail LED
NIC2 Activity LE
NIC1 Activity LED
HDD LED
Power LED
Page 32
X11SSV-M4F User's Manual
Re
D
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table below
for pin denitions.
Power LED
Pin Denitions (JF1)
Pin# Denition
15 +3.3 Stby
16 PWR LED
HDD LED
The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable here to indicate the status of HDD-related activities, including SATA activities. See the table below for pin
denitions.
HDD LED
Pin Denitions (JF1)
Pin# Denition
13 +3.3 Stby
14 HD LED
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on Pins 9 and 10. NIC1 LED and NIC2 LED are 2-pin NIC LED headers. Attach NIC LED cables to NIC1 and NIC2 LED
indicators to display network activities. Refer to the table below for pin denitions.
LAN1/LAN2 LED
Pin Denitions (JF1)
Pin# Denition
9/11 +3.3 Stby
10/12 NIC Activity LED
1. PWR LED
2. HDD LED
3. NIC1 Activity LED
PWR
set
Power Button
Reset Button
2
1
Ground
Ground
4. NIC2 Activity LED
3.3V Stby
3.3V Stby
3.3V Stby
PWR Fail LED
OH/Fan Fail LED
NIC2 Activity LE
4
3.3V Stby
3.3V Stby
3.3V Stby
15 16
NIC1 Activity LED
HDD LED
Power LED
2
1
32
3
Page 33
Chapter 2: Installation
D
Re
D
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset
switch on the computer case to reset the system. Refer to the table below for pin denitions.
Reset Button
Pin Denitions (JF1)
Pin# Denition
3 Reset
4 Ground
Power Button
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both
pins will power on/off the system. This button can also be congured to function as a suspend
button (with a setting in the BIOS - see Chapter 4). To turn off the power in the suspend
mode, press the button for at least 4 seconds. Refer to the table below for pin denitions.
Power Button
Pin Denitions (JF1)
Pin# Denition
1 Signal
2 Ground
2
1
PWR
1
2
set
Power Button
Reset Button
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
15 16
Ground
Ground
PWR Fail LED
OH/Fan Fail LED
NIC2 Activity LE
NIC1 Activity LE
HDD LED
Power LED
1. Power Button
2. Reset Button
33
Page 34
X11SSV-M4F User's Manual
Re
PW
D
Power Fail LED
Connect an LED cable to Power Fail connections on pins 5 and 6 of JF1 to provide warnings
for a power failure. Refer to the table below for pin denitions.
OH/Fan Fail Indicator
Status
Pin # Denition
5 +3.3V Stby
6 PWR Fail LED
Overheat (OH)/Fan Fail
Connect an LED cable to OH/Fan Fail connections on pins 7 and 8 of JF1 to provide warnings
for chassis overheat/fan failure. Refer to the table below for pin denitions.
OH/Fan Fail Indicator
Status
State Denition
Off Normal
On Overheat
Flashing Fan Fail
R
Power Button
Reset Button
set
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
OH/Fan Fail LED
Status
State Denition
7 3.3 Stby
8 OH/Fan Faill
2
1
Ground
Ground
PWR Fail LED
OH/Fan Fail LED
NIC2 Activity LE
NIC1 Activity LED
HDD LED
Power LED
1
2
1. Power Fail LED
2. OH/Fan Fail LED
15 16
34
Page 35
Chapter 2: Installation
2.6 Connectors
Power Connections
Main ATX Power Supply Connector
The primary power supply connector (JPW1) meets the ATX SSI EPS 24-pin specication.
ATX Power 24-pin Connector
Pin Denitions
Pin# Denition Pin# Denition
13 +3.3V 1 +3.3V
14 -12V 2 +3.3V
15 COM 3 COM
16 PS_ON 4 +5V
17 COM 5 COM
18 COM 6 +5V
19 COM 7 COM
20 Res (NC) 8 PWR_OK
21 +5V 9 5VSB
22 +5V 10 +12V
23 +5V 11 +12V
24 COM 12 +3.3V
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JVRM1
JPAC1
JPCIE1 x16
SRW1
SRW2
SRW3
JSD1 JSD2
JGPIO1
I-SATA1
I-SATA2
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
JL1
J16
1
I-SGPIO1
DIMMB1
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
NIC
RST
FF
FAIL
2
ON
COM1
USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. 24-Pin ATX Main PWR
1
35
Page 36
X11SSV-M4F User's Manual
JP1
12V 8-pin CPU Power Connector
JPW2 is a 8-pin 12V DC power input for alternative power source when the 24-pin ATX power
is not in use. Refer to the table below for pin denitions.
+12V 8-pin Power
Pin Denitions
Pin# Denition
5
1
1 - 4 Ground
5 - 8 +12V
8
4
4-pin HDD Power Connector
The 4-pin HDD power connector JP1 provides power to onboard HDD devices. See the table
below for pin denitions.
4-pin HDD Power
Pin Denitions
Pin# Denition
1 12V
2-3 Ground
4 5V
1
4
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JVRM1
JPAC1
JPCIE1 x16
SRW1
SRW2
SRW3
M.2
JSD1 JSD2
JGPIO1
I-SATA1
I-SATA2
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
JL1
J16
1
I-SGPIO1
NIC
1
DIMMB1
OH
NIC
FF
2
LAN1/2
PWR FAIL
RST
JIPMB1
DIMMA1
PWR ON
KB/MS
USB3/4
COM1
USB1/2
USB9
1
CPU
JP1
JPW2
JPW1
JPI2C1
FAN2
2
FAN1
1. 8-Pin Secondary Power
2. 4-pin HDD Power
36
Page 37
Chapter 2: Installation
Headers
Fan Headers
There are three fan headers on the motherboard. These are 4-pin fan headers; pins 1-3 are backward compatible with traditional 3-pin fans. The onboard fan speeds are controlled by Thermal Management (via Hardware Monitoring) in the BIOS. When using Thermal Management setting, please use all 3-pin fans or all 4-pin fans.
Fan Header
Pin Denitions
Pin# Denition
1 Ground (Black)
2 +12V (Red)
3 Tachometer
4 PWM Control
Speaker
On the JD1 header, pins 1-4 are for the internal speaker.
Speaker Connector
Pin Denitions
Pin Setting Denition
Pins 1-4 Internal Speaker
Pins 1-3 Power LED
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JVRM1
JPAC1
JPCIE1 x16
JGPIO1
FAN3
J17
SRW1
SRW2
SRW3
JSD1 JSD2
I-SATA1
I-SATA2
SATA DOM
+POWER
I-SATA3
1
NIC3
J16
1
I-SGPIO1
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
4
JPME1
JBR1
JPUSB1
3
JL1
DIMMB1
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
NIC
RST
FF
FAIL
2
ON
COM1
USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN2
FAN1
1. FAN1
2. FAN2
3. FAN3
4. Speaker
1
2
37
Page 38
X11SSV-M4F User's Manual
BT1
JVRM1
A
AUDIO
DVI-A
LAN3/4
LAN1/2
KB/MS
USB3/4
USB1/2
COM1
Disk-On-Module Power Connector
The Disk-On-Module (DOM) power connectors at JSD1 and JSD2 provide 5V power to a solid-state DOM storage device connected to one of the SATA ports. See the table below for
pin denitions.
DOM Power
Pin Denitions
Pin# Denition
1 5V
2 Ground
3 Ground
Front Accessible Audio Header
A 10-pin audio header located on the motherboard allows you to use the onboard sound for audio playback. Connect an audio cable to the this header to use this feature. See the table
below for pin denitions.
Audio Header
Pin Denitions
Pin# Denition Pin# Denition
1 Microphone_Left 2 Audio_Ground
3 Microphone_Right 4 Audio_Detect
5 Line_2_Right 6 Ground
7 Jack_Detect 8 Key
9 Line_2_Left 10 Ground
1
1
9
2
10
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
JL1
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JVRM2
JI2C1/
JI2C2: 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
3
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
NIC3
SRW1
SRW3
1
2
I-SATA3
I-SGPIO1
JVRM1
M.2
I-SATA2
JPAC1
DIMMB1
NIC
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
2
ON
COM1 USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. JSD1
2. JSD2
3. Audio Header
38
Page 39
JSD1 JSD2
X11SSV-M4F
REV:1.00
DESIGNED IN USA
BT1
I-SATA2
I-SATA1
JPCIE1 x16
JPAC1
JVRM1
JVRM2
JGPIO1
1
SRW1
SRW3
C
LED1
A
SRW2
JBT1
JIPMB1
AUDIO
DVI-A
JI2C1/
1-2:ENABLE
JWD1:
JSMB1:SMBus1
2-3:DISABLE
1-2:RST
WATCH DOG
2-3:NMI
M.2
JI2C2:
USB7/8
JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JD1: 4-7:SPEAKER
1-2:NORMAL
JPME1:
1-3:PWR LED
JBR1 1-2:NORMAL
RECOVERY
2-3:ME
RECOVERY
2-3:BIOS
LAN3/4
LAN1/2
m-PCIE
DIMMA1
DIMMB1
KB/MS
USB3/4
SRW4
Aspeed AST2400
Intel I350-AM2
Intel CM236
Chapter 2: Installation
SGPIO Header
The I-SGPIO1 (Serial General Purpose Input/Output) header is used to communicate with the enclosure management chip on the backplane.
General Purpose I/O Header
JGPIO1 is a 10-pin general purpose I/O header located near the PCI-E x16 slot. Each pin can
be congured to be an input pin or output pin. The GPIO is controlled via the PCA9554 8-bit
GPIO expansion from PCH SMBus. The base address is 0xF040(D31:F4).
SGPIO Header
Pin Denitions
Pin# Denition Pin# Denition
1 NC 2 NC
3 Ground 4 DATA Out
5 Load 6 Ground
7 Clock 8 NC
Pin# Denition Pin# Denition
1 +5V 2 GND
3 GP0 4 GP1
5 GP2 6 GP3
7 GP5 8 GP5
9 GP6 10 GP7
NC = No Connection
SGPIO Header
Pin Denitions
1
9
1
2 8
2
10
7
JPUSB1
2
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JL1
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
AUDIO
1
JPAC1
JPCIE1 x16
SRW2
JSD1 JSD2
JGPIO1
I-SATA1
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
J16
1
I-SGPIO1
SRW1
JVRM1
SRW3
I-SATA2
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
1. I-SGPIO1
LAN1/2
JIPMB1
DIMMA1
DIMMB1
OH
PWR
PWR
NIC
NIC
RST
FF
FAIL
2
ON
1
KB/MS
USB3/4
39
COM1 USB1/2
2. JGPIO
JPW2
JPI2C1
JP1
JPW1
FAN1
FAN2
USB9
CPU
DVI-A
BT1
LAN3/4
A
C
LED1
Intel
USB7/8
USB5/6
LED2
A
I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
JI2C2:
Aspeed AST2400
SRW4
Intel CM236
I-SATA4
JTPM1
1
Page 40
JF1
X11SSV-M4F
REV:1.00
DESIGNED IN USA
I-SATA4
I-SATA2
JVRM1
JVRM2
SRW1
SRW3
A
LED2
C
LED1
A
JBT1
JIPMB1
CPU
JI2C1/ 1-2:ENABLE
JWD1:
JSMB1:SMBus1
2-3:DISABLE
1-2:RST
WATCH DOG
2-3:NMI
M.2
JI2C2:
USB7/8
USB5/6
JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JD1: 4-7:SPEAKER
1-2:NORMAL
JPME1:
1-3:PWR LED
JBR1 1-2:NORMAL
RECOVERY
2-3:ME
RECOVERY
2-3:BIOS
LAN3/4
LAN1/2
m-PCIE
DIMMA1
DIMMB1
USB1/2
COM1
SRW4
Aspeed AST2400
Intel I350-AM2
Intel CM236
X11SSV-M4F User's Manual
TPM Header
The JTPM1 header is used to connect a Trusted Platform Module (TPM), which is available from a third-party vendor. A TPM is a security device that supports encryption and authentication in hard drives. It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Please go to the following link for more information on TPM:
http://www.supermicro.com/manuals/other/TPM.pdf. See the table below for pin denitions.
Trusted Platform Module Header
Pin Denitions
Pin# Denition Pin# Denition
1 LCLK 2 GND
3 LFRAME# 4 No Pin
5 LRESET# 6 +5V (X)
7 LAD3 8 LAD2
9 3.3V 10 LAD1
11 LAD0 12 GND
13 SMB_CLK4 (X) 14 SMB_DAT4 (X)
15 P3V3_STBY 16 SERIRQ
17 GND 18 GND
19 P3V3_STBY 20 LDRQ# (X)
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
JPAC1
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
JGPIO1
FAN3
JL1
JPCIE1 x16
JSD1 JSD2
J17
1
J16
1
SRW2
I-SATA1
SATA DOM
1
DVI-A
AUDIO
JVRM1
JVRM2
SRW1
JI2C1/
JI2C2:
Aspeed
1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1
AST2400
JWD1:
WATCH DOG 1-2:RST 2-3:NMI
SRW3
SRW4
M.2
I-SATA2
+POWER
I-SATA3
I-SATA4
NIC3
JTPM1
I-SGPIO1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
DIMMB1
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
NIC
NIC
LED
LED
2
1
1
KB/MS
USB3/4
COM1
USB1/2
USB9
JPW2
CPU
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
ON
JPI2C1
JPW1
19
JP1
1
220
1. TPM Header
FAN1
FAN2
40
Page 41
Chapter 2: Installation
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable from the chassis to the header to inform you when the chassis is opened.
Chassis Intrusion
Pin Denitions
Pins Denition
1 Intrusion Input
2 Ground
System Management Bus Header
A System Management Bus header for additional slave devices or sensors is located at
JSMB1. See the table below for pin denitions.
External I2C Header
Pin Denitions
Pin# Denition
1 Data
2 Ground
3 Clock
4 NC
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME
JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
JVRM1
SRW1
SRW3
I-SATA2
I-SATA3
NIC3
I-SGPIO1
JPAC1
JI2C1
JI2C2
JSMB1
2
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
1
JL1
NIC
1
DIMMB1
OH
NIC
FF
2
LAN1/2
PWR FAIL
RST
JIPMB1
PWR ON
DIMMA1
KB/MS
USB3/4
COM1
USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. Chassis Intrusion
2. SMBus Header
41
Page 42
X11SSV-M4F User's Manual
SATA Ports
The X11SSV-M4F has four SATA 3.0 ports (I-SATA1 ~ I-SATA4) that are supported by the Intel C236 chipset.
SATA 3.0 Port
Pin Denitions
Pin# Denition
1 Ground
2 SATA_TXP
3 SATA_TXN
4 Ground
5 SATA_RXN
6 SATA_RXP
7 Ground
M.2 Slot
M.2 is formerly known as Next Generation Form Factor (NGFF). The M.2 slot is designed for internal mounting devices. The X11SSV-M4F motherboard deploys an M key only dedicated for SSD devices with the ulitmate performance capability for native PCI-E SSD support. It can also support SATA and NVMe M.2 storage devices.
JPAC1:AUDIO 1-2:ENABLE
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1:
WATCH DOG 1-2:RST 2-3:NMI
JVRM2
BT1
LAN3/4
A
C
LED1
Intel
5
USB7/8
USB5/6
LED2
A
I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
JI2C2:
Aspeed AST2400
SRW4
Intel CM236
2
I-SATA4
JTPM1
43
AUDIO
1
JPCIE1 x16
SRW2
JSD1 JSD2
JVRM1
SRW1
SRW3
M.2
JPAC1
JD1
1
JGPIO1
I-SATA1
I-SATA2
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
JL1
J16
1
I-SGPIO1
DIMMB1
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
NIC
RST
FF
FAIL
2
ON
COM1
USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. I-SATA1
2. I-SATA2
3. I-SATA3
4. I-SATA4
5. M.2 Slot
42
Page 43
Chapter 2: Installation
Power SMB (I2C) Header
The Power System Management Bus (I2C) connector at JPI2C1 monitors the power supply,
fan, and system temperatures. See the table below for pin denitions.
Power SMB Header
Pin Denitions
Pin# Denition
1 Clock
2 Data
3 PMBUS_Alert
4 Ground
5 +3.3V
4-pin BMC External I2C Header
A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect a cable here to use the IPMB I2C connection on your system. See the table below for pin denitions.
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
JBR1
JPUSB1
External I2C Header
Pin Denitions
Pin# Denition
1 Data
2 GND
3 Clock
4 NC
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1
M.2
JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JVRM1
JPAC1
JPCIE1 x16
SRW1
SRW2
SRW3
JSD1 JSD2
JGPIO1
I-SATA1
I-SATA2
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
JL1
J16
1
I-SGPIO1
DIMMB1
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
2
DIMMA1
OH
PWR
PWR
NIC
RST
FF
FAIL
2
ON
COM1
USB1/2
USB9
JP1
JPW2
JPW1
JPI2C1
1
CPU
FAN1
FAN2
1. Power SMB Header
2. BMC External Header
43
Page 44
X11SSV-M4F User's Manual
Mini PCI-E Slot (Mini PCIE)
The Mini PCI-E slot is used to install a compatible Mini PCI-E device. Refer to the table below
for pin denitions.
The mSATA feature leverages the speed and reliability of the SATA interface to provide a high performance, cost-effective storage solution for smaller devices like notebooks and netbooks.
The specication maps SATA signals onto an existing small form factor connector, enabling
more compact integration in a wide variety of applications for both hard disk (HDD) and solid state drives (SSDs). The mSATA connector allows companies to increase the storage offerings of their products without compromising valuable space.
Mini PCI-E
Pin Denitions
Pin# Denition Pin# Denition
52 +3.3Vaux 51 NC
50 GND 49 NC
48 +1.5V 47 NC
46 NC 45 NC
44 NC 43 NC
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
1. Mini-PCIe
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1:
WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
JVRM1
SRW1
SRW3
M.2
I-SATA2
I-SATA3
NIC3
I-SGPIO1
JPAC1
JD1
JL1
DIMMB1
1
NIC
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
2
ON
COM1
USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN2
42 NC 41 +3.3Vaux
40 GND 39 +3.3Vaux
38 USB_D+ 37 GND
36 USB_D- 35 GND
34 GND 33 PETp0
32 SMB_DATA 31 PETn0
30 SMB_CLK 29 GND
28 +1.5V 27 GND
26 GND 25 PERp0
24 +3.3Vaux 23 PERn0
22 PERST# 21 DET_CARD_
20 W_DISABLE# 19 NC
18 GND 17 NC
16 NC 15 GND
FAN1
14 NC 13 REFCLK+
12 NC 11 REFCLK-
10 NC 9 GND
8 NC 7 CLKREQ#
6 1.5V 5 NC
4 GND 3 NC
2 3.3Vaux 1 WAKE#
PLUG
44
Page 45
Chapter 2: Installation
2.7 Jumper Settings
How Jumpers Work
To modify the operation of the motherboard, jumpers can be used to choose between optional
settings. Jumpers create shorts between two pins to change the function of the connector.
Pin 1 is identied with a square solder pad on the printed circuit board. See the diagram at right for an example of jumping pins 1 and 2. Refer to the motherboard layout page for jumper locations.
Note: On two-pin jumpers, "Closed" means the jumper is on and "Open" means the jumper is off the pins.
Connector
Pins
Jumper
Setting
3 2 1
3 2 1
CMOS Clear
JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper
consists of contact pads to prevent accidentally clearing the contents of CMOS.
To Clear CMOS
1. First power down the system and unplug the power cord(s).
2. Remove the cover of the chassis to access the motherboard.
3. Remove the onboard battery from the motherboard.
4. Short the CMOS pads with a metal object such as a small screwdriver for at least four seconds.
5. Remove the screwdriver (or shorting device).
6. Replace the cover, reconnect the power cord(s), and power on the system.
Note: Clearing CMOS will also clear all passwords.
Do not use the PW_ON connector to clear CMOS.
JBT1 contact pads
45
Page 46
X11SSV-M4F User's Manual
SMBus to PCI-E Slots
Jumpers JI2C1 and JI2C2 allow you to connect the System Management Bus (I2C) to the PCI-E slots. The default setting is set to pins 2-3 (Disabled). Both jumpers must be set to the same setting (JI2C1 controls the clock and JI2C2 controls the data).
SMBus to PCI Slots
Jumper Settings
JI2C1 Setting JI2C2 Setting Denition
JI2C1: Pins 1-2 JI2C2: Pins 1-2 Enabled
JI2C1: Pins 2-3 JI2C2: Pins 2-3 Disabled
ME Recovery
Use jumper JPME1 to select ME Firmware Recovery mode, which will limit resource
allocation for essential system operation only in order to maintain normal power operation and management. In the single operation, online upgrade will be available via Recovery mode.
See the table below for jumper settings.
ME Recovery
Jumper Settings
Jumper Setting Denition
Pins 1-2 Normal (Default)
Pins 2-3 ME Recovery
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1:
WATCH DOG 1-2:RST 2-3:NMI
JVRM2
BT1
LAN3/4
A
C
LED1
Intel
USB7/8
USB5/6
LED2
A
I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
JI2C2:
Aspeed AST2400
SRW4
Intel CM236
I-SATA4
JTPM1
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
JVRM1
SRW1
SRW3
I-SATA2
I-SATA3
NIC3
I-SGPIO1
JPAC1
JI2C1
1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
2
JBR1
JPUSB1
JL1
DIMMB1
NIC
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
2
ON
COM1 USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. SMBus to PCI-E Slots
2. ME Recovery
46
Page 47
Chapter 2: Installation
Watch Dog
JWD1 controls the Watch Dog function. Watch Dog is a monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause Watch Dog to reset the system if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that hangs. Watch Dog must also be enabled in BIOS. The default setting is Reset.
Note: When Watch Dog is enabled, the user needs to write their own application software to disable it.
Watch Dog
Jumper Settings
Jumper Setting Denition
Pins 1-2 Reset (Default)
Pins 2-3 NMI
Open Disabled
Onboard Audio Enable
JPAC1 allows you to enable or disable the onboard audio support. The default position is on
pins 1 and 2 to enable onboard audio connections. See the table below for jumper settings.
Audio Enable/Disable
Jumper Settings
Jumper Setting Denition
Pins 1-2 Enabled (Default)
Pins 2-3 Disabled
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1:
WATCH DOG 1-2:RST 2-3:NMI
JVRM2
BT1
LAN3/4
A
C
LED1
Intel
USB7/8
USB5/6
LED2
A
I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
JI2C2:
Aspeed AST2400
SRW4
Intel CM236
I-SATA4
JTPM1
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
JVRM1
SRW1
SRW3
I-SATA2
I-SATA3
NIC3
I-SGPIO1
JPAC1
2
JI2C1
JI2C2
JSMB1
JPG1
JWD1
1
JD1
JPME1
JBR1
JPUSB1
JL1
DIMMB1
NIC
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
2
ON
COM1 USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. Watch Dog
2. Audio Enable
47
Page 48
X11SSV-M4F User's Manual
USB Wake-Up
Use the JPUSB1 jumper to enable system "wake-up" via a USB device. This jumper allows
you to "wake-up" the system by pressing a key on the USB keyboard or by clicking the USB
mouse of your system. The JPUSB1 jumper is used together with the USB Wake-Up function in the BIOS. Enable both the jumper and the BIOS setting to activate this function. See the table on the right for jumper settings and jumper connections.
Note: The default jumper setting is "Disabled". When the "USB Wake-Up" function is
enabled, it will be active on all USB ports.
USB Wake-Up
Jumper Settings
Jumper Setting Denition
Pins 1-2 Enabled
Pins 2-3 Disabled (Default)
BIOS Recovery
Use jumper JBR1 to recover the BIOS settings. The default setting is Normal. See the table below for jumper settings.
ME Recovery
Jumper Settings
Jumper Setting Denition
Pins 1-2 Normal (Default)
Pins 2-3 ME Recovery
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
M.2
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1:
WATCH DOG 1-2:RST 2-3:NMI
JVRM2
BT1
LAN3/4
A
C
LED1
Intel
USB7/8
USB5/6
LED2
A
I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
JI2C2:
Aspeed AST2400
SRW4
Intel CM236
I-SATA4
JTPM1
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
+POWER
1
J16
1
JVRM1
SRW1
SRW3
I-SATA2
I-SATA3
NIC3
I-SGPIO1
JPAC1
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JD1
JPME1
2
JBR1
JPUSB1
1
JL1
DIMMB1
NIC
NIC
1
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
OH
PWR
PWR
RST
FF
FAIL
2
ON
COM1 USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. USB Wake-Up
2. BIOS Recovery
48
Page 49
Chapter 2: Installation
VGA Enable/Disable
Jumper JPG1 allows the user to enable the onbaord VGA connector. The default settting is
pins 1-2 to enable the connection. See the table below for jumper settings.
VGA Enable
Jumper Settings
Jumper Setting Denition
Pins 1-2 Enabled (Default)
Pins 2-3 Disabled
I2C Bus for VRM
Set jumpers JVRM1 and JVRM2 for the BMC or the PCH to access CPU and memory VRM controllers. See the table below for jumper settings.
VRM
Jumper Settings
Jumper Setting Denition
Pins 1-2 BMC (Default)
Pins 2-3 PCH
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
2
3
Aspeed AST2400
SRW4
I-SATA4
JTPM1
BT1
Intel CM236
USB7/8
USB5/6
LED2
A
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
PWR
HDD
LED
LED
AUDIO
1
JGPIO1
FAN3
J17
JPCIE1 x16
SRW2
JSD1 JSD2
I-SATA1
SATA DOM
1
J16
1
+POWER
NIC3
JVRM1
SRW1
SRW3
M.2
I-SATA2
I-SATA3
I-SGPIO1
JPAC1
JI2C1
JI2C2
JSMB1
JPG1
1
JWD1
JD1
JPME1
JBR1
JPUSB1
JL1
NIC
1
DIMMB1
NIC
2
LAN1/2
OH
PWR
FF
FAIL
RST
JIPMB1
DIMMA1
PWR ON
KB/MS
USB3/4
COM1
USB1/2
USB9
CPU
JP1
JPW2
JPW1
JPI2C1
FAN1
FAN2
1. VGA Enable
2. JVRM1
3. JVRM2
49
Page 50
X11SSV-M4F User's Manual
2.8 LED Indicators
LAN Port LEDs
The Ethernet ports located beside the DVI-A port have two LEDs. Each port has two LED indicators. The Activity LED is yellow and indicates connection and activity. The Link LED may be green, amber, or off to indicate the speed of the connection. Refer to the tables below for more information.
Activity Indicator
Color Status Denition
Off No Connection
Yellow Flashing Active
LED Color Denition
Off No Connection or 10 Mb/s
Green 100 Mb/s
Link LED
Amber 1 Gb/s
Link LED
Activity LED
Onboard Power LED
LED2 is an Onboard Power LED. When this LED is lit, it means power is present on the motherboard. Turn off the system and unplug the power cord before removing or installing components.
Onboard Power LED Indicator
LED Color Denition
System Off
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JPUSB1
Off
Green System On
2
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
AUDIO
1
JPAC1
JPCIE1 x16
SRW2
JD1
JBR1
JSD1 JSD2
JGPIO1
I-SATA1
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
JL1
J16
1
I-SGPIO1
BT1
JVRM1
JVRM2
SRW1
JI2C1/
JI2C2:
Aspeed
1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1
AST2400
JWD1: WATCH DOG 1-2:RST 2-3:NMI
SRW3
SRW4
M.2
I-SATA2
I-SATA4
JTPM1
Intel CM236
USB7/8
USB5/6
LAN3/4
A
C
LED1
Intel I350-AM2
m-PCIE
JBT1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
LED2
A
JF1
1
PWR LED
KB/MS
USB3/4
LAN1/2
JIPMB1
DIMMA1
DIMMB1
OH
PWR
HDD
PWR
NIC
NIC
RST
FF
FAIL
LED
2
ON
1
COM1
USB1/2
(power cable not
connected)
USB9
JPW2
JPI2C1
CPU
1. Onboard Power LED
2. LAN Port LED
JP1
JPW1
FAN1
FAN2
50
Page 51
Chapter 2: Installation
BMC Heartbeat LED
LED1 is the BMC heartbeat LED. When the LED is blinking green, BMC is functioning normally. Refer to the table below for the LED status.
Onboard Power LED Indicator
LED Color Denition
Green:
Blinking
BMC Normal
JI2C1
JI2C2
JSMB1
JPG1
JWD1
JPME1
JBR1
JPUSB1
JPAC1:AUDIO 1-2:ENABLE 2-3:DISABLE
DVI-A
JI2C1/ 1-2:ENABLE 2-3:DISABLE JSMB1:SMBus1 JWD1: WATCH DOG 1-2:RST 2-3:NMI
JVRM2
JI2C2:
BT1
1
Aspeed AST2400
LAN3/4
A
C
LED1
Intel I350-AM2
AUDIO
1
JPCIE1 x16
JVRM1
SRW1
JPAC1
LAN1/2
JIPMB1
KB/MS
USB3/4
COM1
USB1/2
USB9
JP1
JPW2
1. BMC Heartbeat
JPW1
SRW2
SRW3
SRW4
Intel CM236
JBT1
JD1
M.2
JSD1 JSD2
I-SATA4
JTPM1
USB7/8
USB5/6
LED2
A
JGPIO1
I-SATA1
I-SATA2
FAN3
SATA DOM
+POWER
I-SATA3
J17
1
NIC3
JL1
J16
1
I-SGPIO1
REV:1.00
DESIGNED IN USA
X11SSV-M4F
JD1: 4-7:SPEAKER 1-3:PWR LED
JPME1: 1-2:NORMAL
RECOVERY
2-3:ME
JBR1 1-2:NORMAL 2-3:BIOS
RECOVERY JPUSB1: USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
JF1
m-PCIE
PWR LED
DIMMB1
DIMMA1
JPI2C1
CPU
FAN1
FAN2
OH
PWR
HDD
PWR
NIC
NIC
RST
FF
FAIL
LED
2
ON
1
51
Page 52
X11SSV-M4F User's Manual
Chapter 3
Troubleshooting
3.1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/ or ‘Returning Merchandise for Service’ section(s) in this chapter. Always disconnect the AC power cord before adding, changing or installing any non hot-swap hardware components.
Before Power On
1. Check that the power LED on the motherboard is on.
2. Make sure that the power connector is connected to your power supply.
3. Make sure that no short circuits exist between the motherboard and chassis.
4. Disconnect all cables from the motherboard, including those for the keyboard and mouse.
5. Remove all add-on cards.
6. Install a CPU, a heatsink*, and connect the internal speaker and the power LED to the
motherboard. Check all jumper settings as well. (Make sure that the heatsink is fully
seated.)
7. Use the correct type of onboard CMOS battery (CR2032) as recommended by the manufacturer. To avoid possible explosion, do not install the CMOS battery upside down.
No Power
1. Make sure that no short circuits exist between the motherboard and the chassis.
2. Verify that all jumpers are set to their default positions.
3. Check that the 115V/230V switch on the power supply is properly set.
4. Turn the power switch on and off to test the system.
5. The battery on your motherboard may be old. Check to verify that it still supplies ~3VDC. If it does not, replace it with a new one.
52
Page 53
Chapter 3: Troubleshooting
No Video
1. This board only provides an analog video output from the DVI-A port. Please ensure your monitor supports analog signal.
2. Use the speaker to determine if any beep codes exist. Refer to Appendix A for details on beep codes.
Note: If you are a system integrator, VAR or OEM, a POST diagnostics card is recom­mended. For I/O port 80h codes, refer to Appendix B.
System Boot Failure
If the system does not display POST (Power-On-Self-Test) or does not respond after the power is turned on, check the following:
1. Check for any error beep from the motherboard speaker.
If there is no error beep, try to turn on the system without DIMM modules installed. If there
is still no error beep, replace the motherboard.
If there are error beeps, clear the CMOS settings by unplugging the power cord and
contacting both pads on the CMOS Clear Jumper (JBT1). Refer to chapter 2.
2. Remove all components from the motherboard, especially the DIMM modules. Make sure that system power is on and that memory error beeps are activated.
3. Turn on the system with only one DIMM module installed. If the system boots, check for bad DIMM modules or slots by following the Memory Errors Troubleshooting procedure in this Chapter.
Memory Errors
1. Make sure that the DIMM modules are properly and fully installed.
2. Conrm that you are using the correct memory. Also, it is recommended that you use the same memory type and speed for all DIMMs in the system. See Section 2.4 for memory details.
3. Check for bad DIMM modules or slots by swapping modules between slots and noting the results.
4. Check the power supply voltage 115V/230V switch.
53
Page 54
X11SSV-M4F User's Manual
Losing the System's Setup Conguration
1. Make sure that you are using a high quality power supply. A poor quality power supply may cause the system to lose the CMOS setup information. Refer to Section 1.5 for details on recommended power supplies.
2. The battery on your motherboard may be old. Check to verify that it still supplies ~3VDC. If it does not, replace it with a new one.
3. If the above steps do not x the setup conguration problem, contact your vendor for repairs.
When the System Becomes Unstable
A. If the system becomes unstable during or after OS installation, check the following:
1. CPU/BIOS support: Make sure that your CPU is supported and that you have the latest BIOS installed in your system.
2. Memory support: Make sure that the memory modules are supported by testing the modules using memtest86 or a similar utility.
Note: Refer to the product page on our website at http:\\www.supermicro.com for memory and CPU support and updates.
3. HDD support: Make sure that all hard disk drives (HDDs) work properly. Replace the bad HDDs with good ones.
4. System cooling: Check the system cooling to make sure that all heatsink fans and CPU/ system fans, etc., work properly. Check the hardware monitoring settings in the IPMI to make sure that the CPU and system temperatures are within the normal range. Also check the front panel Overheat LED and make sure that it is not on.
5. Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connected. Please refer to our website for more information on the minimum power requirements.
6. Proper software support: Make sure that the correct drivers are used.
B. If the system becomes unstable before or during OS installation, check the following:
1. Source of installation: Make sure that the devices used for installation are working properly, including boot devices such as CD/DVD and CD/DVD-ROM.
2. Cable connection: Check to make sure that all cables are connected and working properly.
54
Page 55
Chapter 3: Troubleshooting
3. Using the minimum conguration for troubleshooting: Remove all unnecessary components (starting with add-on cards rst), and use the minimum conguration (but
with a CPU and a memory module installed) to identify the trouble areas. Refer to the steps listed in Section A above for proper troubleshooting procedures.
4. Identifying bad components by isolating them: If necessary, remove a component in question from the chassis, and test it in isolation to make sure that it works properly. Replace a bad component with a good one.
5. Check and change one component at a time instead of changing several items at the same time. This will help isolate and identify the problem.
6. To nd out if a component is good, swap this component with a new one to see if the system will work properly. If so, then the old component is bad. You can also install the component in question in another system. If the new system works, the component is good and the old system has problems.
55
Page 56
X11SSV-M4F User's Manual
3.2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, note that as a
motherboard manufacturer, we do not sell directly to end-users, so it is best to rst check with
your distributor or reseller for troubleshooting services. They should know of any possible
problem(s) with the specic system conguration that was sold to you.
1. Please review the ‘Troubleshooting Procedures’ and 'Frequently Asked Questions' (FAQs) sections in this chapter or see the FAQs on our website before contacting Technical Support.
2. BIOS upgrades can be downloaded from our website. Note: Not all BIOS can be
ashed depending on the modications to the boot block code.
3. If you still cannot resolve the problem, include the following information when contacting us for technical support:
Motherboard model and PCB revision number
BIOS release date/version (this can be seen on the initial display when your system rst
boots up)
System conguration
An example of a Technical Support form is posted on our website.
Distributors: For immediate assistance, please have your account number ready when contacting our technical support department by e-mail.
56
Page 57
Chapter 3: Troubleshooting
3.3 Frequently Asked Questions
Question: What type of memory does my motherboard support?
Answer: The X11SSV-M4F motherboard supports up to 32GB of DDR4 ECC SO-DIMM 2133
MT/s. See Section 2.3 for details on installing memory.
Question: How do I update my BIOS?
Answer: It is recommended that you do not upgrade your BIOS if you are not experiencing
any problems with your system. Updated BIOS les are located on our website at http://www.
supermicro.com. Please check our BIOS warning message and the information on how to
update your BIOS on our website. Select your motherboard model and download the BIOS
le to your computer. Also, check the current BIOS revision to make sure that it is newer than your BIOS before downloading. Please unzip the BIOS le onto a bootable USB device. Run the batch le using the format FLASH.BAT lename.rom from your bootable USB device to ash the BIOS. Then, your system will automatically reboot.
Question: Why can't I turn off the power using the momentary power on/off switch?
Answer: The instant power off function is controlled in BIOS by the Power Button Mode
setting. When the On/Off feature is enabled, the motherboard will have instant off capabilities as long as the BIOS has control of the system. When the Standby or Suspend feature is
enabled or when the BIOS is not in control such as during memory count (the rst screen
that appears when the system is turned on), the momentary on/off switch must be held for more than four seconds to shut down the system. This feature is required to implement the ACPI features on the motherboard.
57
Page 58
X11SSV-M4F User's Manual
3.4 Battery Removal and Installation
Battery Removal
To remove the onboard battery, follow the steps below:
1. Power off your system and unplug your power cable.
2. Locate the onboard battery as shown below.
3. Using a tool such as a pen or a small screwdriver, push the battery lock outwards to unlock it. Once unlocked, the battery will pop out from the holder.
4. Remove the battery.
Proper Battery Disposal
Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery
in the garbage or a public landll. Please comply with the regulations set up by your local
hazardous waste management agency to dispose of your used battery properly.
Battery Installation
1. To install an onboard battery, follow the steps 1 & 2 above and continue below:
2. Identify the battery's polarity. The positive (+) side should be facing up.
3. Insert the battery into the battery holder and push it down until you hear a click to ensure that the battery is securely locked.
Important: When replacing a battery, be sure to only replace it with the same type.
OR
58
Page 59
Chapter 3: Troubleshooting
3.5 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. When returning to the manufacturer, the RMA number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand-carried. Shipping and handling charges will be applied for all orders that must be mailed when service is complete.
For faster service, RMA authorizations may be requested online (http://www.supermicro.com/
support/rma/).
This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alteration, misuse, abuse or improper maintenance of products.
During the warranty period, contact your distributor rst for any product problems.
59
Page 60
X11SSV-M4F User's Manual
Chapter 4
BIOS
4.1 Introduction
This chapter describes the AMIBIOS™ Setup utility for the X11SSV-M4F motherboard. The
BIOS is stored on a chip and can be easily upgraded using a ash program.
Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual
Download area of our website for any changes to BIOS that may not be reected in
this manual.
Starting the Setup Utility
To enter the BIOS Setup Utility, hit the <Delete> key while the system is booting-up. (In most cases, the <Delete> key is used to invoke the BIOS setup screen. There are a few cases when other keys are used, such as <F1>, <F2>, etc.) Each main BIOS menu option is described in this manual.
The Main BIOS screen has two main frames. The left frame displays all the options that can
be congured. “Grayed-out” options cannot be congured. The right frame displays the key
legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note that BIOS has default text messages built in. We retain the option to include, omit, or change any of these text messages.) Settings printed in Bold are the default values.
A " " indicates a submenu. Highlighting such an item and pressing the <Enter> key will open the list of settings within that submenu.
The BIOS setup utility uses a key-based navigation system called hot keys. Most of these hot keys (<F1>, <F2>, <F3>, <Enter>, <ESC>, <Arrow> keys, etc.) can be used at any time during the setup navigation process.
60
Page 61
Chapter 4: BIOS
4.2 Main Setup
When you rst enter the AMI BIOS setup utility, you will enter the Main setup screen. You can
always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS setup screen is shown below.The following Main menu items will be displayed:
System Date/System Time
Use this option to change the system date and time. Highlight System Date or System Time using the arrow keys. Enter new values using the keyboard. Press the <Tab> key or the arrow
keys to move between elds. The date must be entered in MM/DD/YYYY format. The time
is entered in HH:MM:SS format.
Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is 01/01/2015 after RTC reset.
Supermicro X11SSV-M4F
BIOS Version
This item displays the version of the BIOS ROM used in the system.
Build Date
This item displays the date when the version of the BIOS ROM used in the system was built.
61
Page 62
X11SSV-M4F User's Manual
Memory Information
Total Memory
This item displays the total size of memory available in the system.
Memory Speed
This item displays the memory speed.
62
Page 63
Chapter 4: BIOS
4.3 Advanced Setup Congurations
Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items.
Warning: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable. When this occurs, revert to the default to the manufacture default settings.
Boot Feature
Quiet Boot
Use this feature to select the screen display between the POST messages and the OEM logo upon bootup. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The options are Enabled and Disabled.
AddOn ROM Display Mode
Use this feature to set the display mode for the Option ROM. Select Keep Current to display the current AddOn ROM setting. Select Force BIOS to use the Option ROM display set by the system BIOS. The options are Force BIOS and Keep Current.
Bootup NumLock State
Use this feature to set the Power on state for the <Numlock> key. The options are Off and On.
63
Page 64
X11SSV-M4F User's Manual
Wait For 'F1' If Error
Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs. The options are Disabled and Enabled.
INT19 (Interrupt 19) Trap Response
Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Immediate, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup immediately and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Postponed, the ROM BIOS of the host adaptors will not capture Interrupt 19 immediately and allow the drives attached to these adaptors to function as bootable devices at bootup. The options are Immediate and Postponed.
Re-try Boot
If this item is enabled, the BIOS will automatically reboot the system from a specied boot
device after its initial boot failure. The options are Disabled, Legacy Boot, and EFI Boot.
Install Windows 7 USB Support
Enable this feature to use the USB keyboard and mouse during the Windows 7 installation, since the native XHCI driver support is unavailable. Use a SATA optical drive as a USB drive, and USB CD/DVD drives are not supported. Disable this feature after the XHCI driver has been installed in Windows. The options are Disabled and Enabled.
Power Conguration
Watch Dog Function
If enabled, the Watch Dog Timer will allow the system to reset or generate NMI based on jumper settings when it is expired for more than 5 minutes. The options are Disabled and Enabled.
Power Button Function
This feature controls how the system shuts down when the power button is pressed. Select 4 Seconds Override for the user to power off the system after pressing and holding the power button for 4 seconds or longer. Select Instant Off to instantly power off the system as soon as the user presses the power button. The options are Instant Off and 4 Seconds Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Stay Off for the system power to remain off after a power loss. Select Power On for the system power to be turned on after a power loss. Select Last State to allow the system to resume its last power state before a power loss. The options are Stay Off, Power On, and Last State.
64
Page 65
CPU Conguration
The following CPU information will display:
Displays the CPU type
CPU Signature
Microcode Patch
Max CPU Speed
Min CPU Speed
CPU Speed
Processor Cores
Chapter 4: BIOS
Hyper Threading Technology
Intel VT-x Technology
Intel SMX Technology
64-bit
EIST Technology
CPU C3 State
CPU C6 State
CPU C7 State
CPU C8 State
CPU C9 State
CPU C10 State
L1 Data Cache
L1 Code Cache
L2 Cache
L3 Cache
L4 Cache
65
Page 66
X11SSV-M4F User's Manual
Hyper-threading (Available when supported by the CPU)
Select Enabled to support Intel Hyper-threading Technology to enhance CPU performance. The options are Enabled and Disabled.
Active Processor Cores
This feature determines how many CPU cores will be activated for each CPU. When all is selected, all cores in the CPU will be activated. (Please refer to Intel's website for more information.) The options are All and 1, 2, and 3.
Execute Disable Bit (Available if supported by the OS & the CPU)
Select Enabled to enable the Execute-Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot,
thus preventing a worm or a virus from ooding illegal codes to overwhelm the processor or
damage the system during an attack. The default is Enabled. (Refer to Intel and Microsoft Web sites for more information.)
Intel® Virtualization Technology
Select Enable to use Intel Virtualization Technology so that I/O device assignments will be reported directly to the VMM (Virtual Memory Management) through the DMAR ACPI Tables. This feature offers fully-protected I/O resource-sharing across the Intel platforms, providing the user with greater reliability, security and availability in networking and data-sharing. The options are Disabled and Enabled.
Hardware Prefetcher (Available when supported by the CPU)
If set to Enabled, the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance. The options are Disabled and Enabled.
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU prefetches the cache line for 64 bytes if this feature is set to Disabled. The CPU prefetches both cache lines for 128 bytes as comprised if this feature is set to Enabled.
CPU AES
Select Enabled to enable Intel CPU Advanced Encryption Standard (AES) Instructions for CPU to enhance data integrity. The options are Disabled and Enabled.
Boot Performance Mode
This feature allows the user to select the performance state that the BIOS will set before the operating system handoff. The options are Power Saving, Max Non-Turbo Performance, and Turbo Performance.
66
Page 67
Chapter 4: BIOS
HardWare P-States (HWP)
Use this feature to enable or disable hardware P-States support. The options are Disabled and Enabled.
Intel® SpeedStep™
Intel SpeedStep Technology allows the system to automatically adjust processor voltage and
core frequency to reduce power consumption and heat dissipation. The options are Disabled and Enabled.
Turbo Mode
Select Enabled for processor cores to run faster than the frequency specied by the
manufacturer. The options are Disabled and Enabled.
Package Power Limit MSR Lock
Select Enabled to lock the package power limit for the model specic registers. The options
are Disabled and Enabled.
Power Limit 1 Override
Select Enabled to support average power limit (PL1) override. The default setting is Disabled.
Power Limit 2 Override
Select Enabled to support rapid power limit (PL2) override. The default setting is Enabled.
Power Limit 2
Use this item to congure the value for Power Limit 2. The value is in milli watts and the step
size is 125mW. Use the number keys on your keyboard to enter the value. Enter 0 to use the manufacture default setting. If the value is 0, the BIOS will set PL2 as 1.25* TDP.
1-Core Ratio Limit Override
This increases (multiplies) 1 clock speed in the CPU core in relation to the bus speed when one CPU core is active. Press "+" or "-" on your keyboard to change the value. Enter 0 to use the manufacture default setting.
2-Core Ratio Limit Override
This increases (multiplies) 2 clock speeds in the CPU core in relation to the bus speed when two CPU cores are active. Press "+" or "-" on your keyboard to change the value. Enter 0 to use the manufacture default setting.
3-Core Ratio Limit Override
This increases (multiplies) 3 clock speeds in the CPU core in relation to the bus speed when three CPU cores are active. Press "+" or "-" on your keyboard to change the value. Enter 0 to use the manufacture default setting.
67
Page 68
X11SSV-M4F User's Manual
4-Core Ratio Limit Override
This increases (multiplies) 4 clock speeds in the CPU core in relation to the bus speed when three CPU cores are active. Press "+" or "-" on your keyboard to change the value. Enter 0 to use the manufacture default setting.
CPU C-States
Use this feature to enable the C-State of the CPU. The options are Disabled and Enabled.
Enhanced C-States
Use this feature to enable the enhanced C-State of the CPU. The options are Disabled and
Enabled.
C-State Auto Demotion
Use this feature to prevent unnecessary excursions into the C-states to improve latency. The options are Disabled, C1, C3, and C1 and C3.
C-State Un-Demotion
This feature allows the user to enable or disable the un-demotion of C-State. The options are Disabled, C1, C3, and C1 and C3
Package C-State Demotion
Use this feature to enable or disable the Package C-State demotion. The options are Disabled and Enabled.
Package C-State Un-Demotion
Use this feature to enable or disable the Package C-State un-demotion. The options are
Disabled and Enabled.
C-State Pre-Wake
This feature allows the user to enable or disable the C-State Pre-Wake. The options are Disabled and Enabled.
Package C-State Limit
Use this feature to set the Package C-State limit. The options are C0/C1, C2, C3, C6, C7, C7s, C8, and Auto.
CPU Thermal Conguration
CPU DTS
Select Enabled for the ACPI thermal management to use the DTS SMM mechanism to obtain CPU temperature values. Select Disabled for EC to report the CPU temperature values. The options are Disabled and Enabled.
68
Page 69
Chapter 4: BIOS
ACPI 3.0 T-States
Select Enabled to support CPU throttling by the operating system to reduce power consumption. The options are Disabled and Enabled.
Chipset Conguration
Warning: Setting the wrong values in the following features may cause the system to malfunc­tion.
System Agent (SA) Conguration
The following System Agent information will display:
System Agent Bridge Name
SA PCIe Code Version
VT-d
VT-d
Select Enabled to enable Intel Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to VMM through the DMAR ACPI Tables. This feature offers fully-protected I/O resource-sharing across the Intel platforms, providing the user with greater reliability, security and availability in networking and data-sharing. The options are
Enabled and Disabled.
SW Guard Extensions (SGX)
Use this feature to enable or disable the Intel Software Guard Extensions (SGX). SGX is a set of CPU instructions that increases software security. The options are Disabled, Enabled, and Software Controlled.
Select Owner EPOCH Input Type
Use this feature to select an Intel Software Guard Extensions (SGX) EPOCH mode. Each mode has different values, which can be entered manually. The options are No Change
in Owner EPOCHs, Change to New Random Owner EPOCHs, and Manual User Dened
Owner EPOCHs.
PRMRR Size
The BIOS must reserve a contiguous region of Processor Reserved Memory (PRM) in the Processor Reserved Memory Range Register (PRMRR). This feature appears if SW Guard Extensions is set to Enabled. The options are Auto, 32MB, 64MB, and 128MB.
69
Page 70
X11SSV-M4F User's Manual
eDRAM Mode
Use this feature to select the eDRAM mode. The options are SW Mode eDRAM Off, SW Mode eDRAM On, and eDRAM HW Mode.
Graphics Conguration
Primary Display
Use this feature to select the graphics device to be used as the primary display. The options are PEG and PCIE.
Internal Graphics
Select Auto to keep an internal graphics device installed on an expansion slot supported by the CPU to be automatically enabled. The options are Auto, Disabled, and Enabled.
GTT Size
Use this feature to set the memory size to be used by the graphics translation table (GTT). The options are 2MB, 4MB, and 8MB.
Aperture Size
Use this feature to set the Aperture size, which is the size of system memory reserved by the BIOS for graphics device use. The options are 128MB, 256MB, 512 MB, 1024MB, 2048MB, and 4096MB.
DVMT Pre-Allocated
Dynamic Video Memory Technology (DVMT) allows dynamic allocation of system memory to be used for video devices to ensure best use of available system memory based on the DVMT 5.0 platform. The options are 32M, 64M, 4M, 8M, 12M, 16M, 20M, 24M, 28M, 32M/ F7, 36M, 40M, 44M, 48M, 52M, 56M, and 60M.
DVMT Total IGFX Memory
Use this feature to set the total memory size to be used by internal graphics devices based on the DVMT 5.0 platform. The options are 128MB, 256MB, and MAX.
IGFX (Graphics) Low Power Mode
Select Enabled to use the low power mode for internal graphics devices installed in a small form factor (SFF) computer. The options are Enabled and Disabled.
PM Support
Use this item to enable the IGFX Power Management function. The options are Enabled and Disabled.
PAVP Enable
Use this feature to enable or disable the protected audio video path (PAVP). The options are Disabled or Enabled.
70
Page 71
Chapter 4: BIOS
DMI/OPI Conguration
The following DMI information will display:
DMI
DMI VC1 Control
Use this feature to enable or disable DMI Virtual Channel 1. The options are Enabled and
Disabled.
DMI VCm Control
Use this feature to enable or disable the DMI Virtual Channel map. The options are Enabled and Disabled.
CPU DMI Link ASPM Control
Use this feature to set the ASPM (Active State Power Management) state on the SA (System Agent) side of the DMI Link. The options are Disabled and L1.
DMI Extended Sync Control
Use this feature to enable or disable the DMI extended synchronization. The options are Enabled and Disabled.
DMI De-Emphasis Control
Use this feature to congure the De-emphasis control on DMI. The options are -6 dB and
-3.5 dB.
PEG Port Conguration
SLOT1 Link Width
Use this item to congure the link width of a PCI-E port specied by the user. The options
are x16 and x8x8.
PEG0 Enable Root Port
Use this feature to enable or disable the PCI Express Graphics (PEG) device in the port
specied by the user. The options are Disabled, Enabled, and Auto.
PEG0 Max Link Speed
Use this item to congure the link speed of a PCI-E port specied by the user. The options
are Auto, Gen1, Gen2, and Gen3.
PEG0 Max Payload Size
Select Auto for the system BIOS to automatically set the maximum payload value for a PCI-E device to enhance system performance. The options are Auto, 128 TLP, and 256 TLP.
71
Page 72
X11SSV-M4F User's Manual
PEGO ASPM
Use this feature to control ASPM support for the PEG 0. The options are Disabled, Auto, ASPM L0s, ASPM L1, and ASPM L0s & L1.
PEG0 Slot Power Limit Value
Use this feature to set the upper limit on the power supplied by the PCIE slot. Press "+" or "-" on your keyboard to change this value. The default setting is 75.
PEG0 Slot Power Limit Scale
Use this feature to select the scale used for the slot power limit value. The options are
1.0x, 0.1x, 0.01x, and 0.001x.
Program PCIe ASPM After OPROM
PCIe ASPM, the Active State Power Management for PCI Express slots, is a power management protocol used to manage power consumption of serial-link devices installed on PCI-Exp slots during a prolonged off-peak time. If this item is set to Enabled, PCI-E ASMP will be programmed after OPROM. If this item is set to Disabled, the PCI-E ASPM will be programmed before OPROM. The options are Disabled and Enabled.
Memory Conguration
The following memory information will display:
Memory RC Version
Memory Frequency
Total Memory
VDD
DIMMA1
DIMMA2
DIMMB1
DIMMB2
Memory Timings (tCL-tRCD-tRP-tRAS)
Maximum Memory Frequency
Use this feature to set the maximum memory frequency for onboard memory modules. The options are Auto, 1067, 1200, 1333, 1400, 1600, 1800, 1867, 2000, 2133, 2200, 2400, 2600, 2667, 2800, 2933, 3000, and 3200.
72
Page 73
Chapter 4: BIOS
Max TOLUD
This feature sets the maximum TOLUD value, which species the "Top of Low Usable
DRAM" memory space to be used by internal graphics devices, GTT Stolen Memory, and TSEG, respectively, if these devices are enabled. The options are Dynamic, 1 GB, 1.25 GB, 1.5 GB, 1.75 GB, 2 GB, 2.25 GB, 2.5 GB, 2.75 GB, 3 GB, 3.25 GB, and 3.5 GB.
Energy Performance Gain
Use this feature to enable or disable the energy performance gain. The options are Disabled and Enabled.
Memory Scrambler
Select Enabled to enable memory scrambler support. The options are Disabled and
Enabled.
Fast Boot
Use this feature to enable or disable fast path through the memory reference code. The options are Enabled and Disabled.
REFRESH_2X_MODE
Use this feature to select the refresh mode. The options are Disabled, 1-Enabled for WARM or HOT, and 2-Enabled HOT only.
Closed Loop Thermal Management
Use this feature to monitor the power consumption and temperature of the system to predict a thermal trend. The options are Disabled and Enabled.
PCH-IO Conguration
The following PCH-IO information will display:
Intel PCH RC Version
Intel PCH SKU Name
Intel PCH Rev ID
Port 61h Bit-4 Emulation
Select Enabled to enable the emulation of Port 61h bit-4 toggling in SMM (System Management Mode). The options are Disabled and Enabled.
PCIe PLL SSC
Enable this feature to reduce EMI interference by down spreading clock 0.5%. Disable this feature to centralize the clock without spreading. The options are Disabled and Enabled.
73
Page 74
X11SSV-M4F User's Manual
SATA Conguration
When this submenu is selected, the AMI BIOS automatically detects the presence of the SATA devices that are supported by the Intel PCH chip and displays the following items:
SATA Controller(s)
This item enables or disables the onboard SATA controller supported by the Intel PCH chip. The options are Enabled and Disabled.
SATA Mode Selection
Use this item to select the mode for the installed SATA drives. The options are AHCI and RAID.
*If the item above "SATA Mode Selection" is set to RAID, the following items will display:
SATA RAID Option ROM/UEFI Driver
Select UEFI to load the EFI drvier for system boot. Select Legacy to load a legacy driver for system boot. The options are Legacy ROM and UEFI Driver.
SATA Frozen
Use this item to enable the HDD Security Frozen Mode. The options are Enabled and
Disabled.
Aggressive LPM Support
Use this item to allow the SATA controller to enter a low-power state during HDD inactivity. The options are Disabled and Enabled.
Serial ATA Port 0 ~ Port 5
This item displays the information detected on the installed SATA drive on the particular SATA port.
Model number of drive and capacity
Software Preserve Support
Port 0 ~ Port 5 Hot Plug
This feature designates the SATA port specied for hot plugging. Set this item to Enabled
for hot-plugging support, which will allow the user to replace a SATA disk drive without shutting down the system. The options are Disabled and Enabled.
Port 0 ~ Port 5 Spin Up Device
On an edge detect from 0 to 1, set this item to allow the PCH to initialize the device. The options are Enabled and Disabled.
74
Page 75
Chapter 4: BIOS
Port 0 ~ Port 5 SATA Device Type
Use this item to specify if the SATA port specied by the user should be connected to a Solid
State drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State Drive.
PCIe/PCI/PnP Conguration
The following information will display:
PCI Bus Driver Version
PCI Devices Common Settings:
PCI PERR/SERR Support
Select Enabled to allow a PCI device to generate a PERR/SERR number for a PCI Bus Signal Error Event. The options are Disabled and Enabled.
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address. The options are Disabled and Enabled.
SR-IOV Support
Use this feature to enable or disable Single Root IO Virtualization Support. The options are
Disabled and Enabled.
CPU PCI-E 3.0 X16 OPROM
Use this feature to select which rmware type to be loaded for the add-on card in this slot.
The options are Disabled, Legacy, and EFI.
PCH mPCI-E 3.0 X1 OPROM
Use this feature to select which rmware type to be loaded for the add-on card in this slot.
The options are Disabled, Legacy, and EFI.
PCH m.2 SLOT OPROM
Use this feature to select which rmware type to be loaded for the add-on card in this slot.
The options are Disabled, Legacy, and EFI.
Onboard LAN Option ROM Type
Use this item to select the onboard LAN Option ROM type. The options are Legacy and EFI.
Onboard LAN1 Option ROM
Use this item to select the Option ROM type for onboard LAN1. The options are Disabled and PXE.
75
Page 76
X11SSV-M4F User's Manual
Onboard LAN2 Option ROM
Use this item to select the Option ROM type for onboard LAN2. The options are Disabled and PXE.
Onboard LAN3 Option ROM
Use this item to select the Option ROM type for onboard LAN3. The options are Disabled and PXE.
Onboard LAN4 Option ROM
Use this item to select the Option ROM type for onboard LAN4. The options are Disabled and PXE.
Onboard Video Option ROM
Use this item to select the onboard Video Option ROM type. The options are Disabled,
Legacy, and EFI.
Network Stack
Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unied Extensible
Firmware Interface) for network stack support. The options are Disabled and Enabled.
IPv4 PXE Support
Select Enabled to enable IPv4 PXE boot support. The options are Disabled and Enabled.
IPv6 PXE Support
Select Enabled to enable IPv6 PXE boot support. The options are Disabled and Enabled.
PXE boot wait time
Use this option to specify the wait time to press the ESC key to abort the PXE boot. Press "+" or "-" on your keyboard to change the value. The default setting is 0.
Media detect count
Use this option to specify the number of times media will be checked. Press "+" or "-" on your keyboard to change the value. The default setting is 1.
76
Page 77
Chapter 4: BIOS
Super IO Conguration
The following Super IO information will display:
Super IO Chip AST2400
Serial Port 1
Select Enabled to enable the selected onboard serial port. The options are Disabled and
Enabled.
Logical Device Settings
This item displays the status of a serial part specied by the user.
Serial Port 1 Change Settings
This feature species the base I/O port address and the Interrupt Request address of a serial port specied by the user. Select Auto to allow the BIOS to automatically assign the base
I/O and IRQ address. The options are Auto, (IO=3F8h; IRQ=4;); (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;); (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;); (IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;); and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;).
Serial Port 2 (SOL)
Serial Port 2
Select Enabled to enable the selected onboard serial port. The options are Disabled and
Enabled.
Logical Device Settings
This item displays the status of a serial part specied by the user.
Serial Port 2 (SOL) Change Settings
This feature species the base I/O port address and the Interrupt Request address of a serial port specied by the user. Select Auto to allow the BIOS to automatically assign the base
I/O and IRQ address. The options are Auto, (IO=2F8h; IRQ=3;), (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;), (IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;), and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;).
Intel Server Platform Services
The following Intel Server Platform Services information will display:
ME BIOS Interface Version
SPS Version
77
Page 78
X11SSV-M4F User's Manual
ME FW Status Value
ME FW State
ME FW Operation State
ME FW Error Code
ME NM FW Status Value
BIOS Booting Mode
Cores Disabled
ME FW SKU Information
End-of-POST Status
Serial Port Console Redirection
COM1 Console Redirection
Select Enabled to enable console redirection support for a serial port specied by the user.
The options are Enabled and Disabled.
*If the item above set to Enabled, the following items will become available for user's
conguration:
COM1 Console Redirection Settings
This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
COM1 Terminal Type
This feature allows the user to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI.
COM1 Bits per second
Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
78
Page 79
Chapter 4: BIOS
COM1 Data Bits
Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits.
COM1 Parity
A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark, and Space.
COM1 Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.
COM1 Flow Control
Use this feature to set the ow control for Console Redirection to prevent data loss caused by buffer overow. Send a "Stop" signal to stop sending data when the receiving buffer is full.
Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.
COM1 VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled.
COM1 Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled.
COM1 Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and
Enabled.
COM1 Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25.
COM1 Putty KeyPad
This feature selects the settings for Function Keys and KeyPad used for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SC0, ESCN, and VT400.
79
Page 80
X11SSV-M4F User's Manual
COM1 Redirection After BIOS POST
Use this feature to enable or disable legacy console redirection after BIOS POST. When set to Bootloader, legacy console redirection is disabled before booting the OS. When set to Always Enable, legacy console redirection remains enabled when booting the OS. The options are
Always Enable and Bootloader.
SOL
SOL Console Redirection
Select Enabled to use the SOL port for Console Redirection. The options are Disabled and Enabled.
*If the item above set to Enabled, the following items will become available for user's
conguration:
SOL Console Redirection Settings
Use this feature to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
SOL Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.
SOL Bits Per second
Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
SOL Data Bits
Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits.
SOL Parity
A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark and Space.
80
Page 81
Chapter 4: BIOS
SOL Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.
SOL Flow Control
Use this feature to set the ow control for Console Redirection to prevent data loss caused by buffer overow. Send a "Stop" signal to stop sending data when the receiving buffer is full.
Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.
SOL VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled.
SOL Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled.
SOL Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and
Enabled.
SOL Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25.
SOL Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400.
SOL Redirection After BIOS POST
Use this feature to enable or disable legacy Console Redirection after BIOS POST. When set to Bootloader, legacy Console Redirection is disabled before booting the OS. When set to Always Enable, legacy Console Redirection remains enabled when booting the OS. The options are Always Enable and Bootloader.
EMS (Emergency Management Services) Console Redirection
Select Enabled to use a COM port selected by the user for EMS Console Redirection. The options are Enabled and Disabled.
*If the item above set to Enabled, the following items will become available for user's
conguration:
81
Page 82
X11SSV-M4F User's Manual
EMS Console Redirection Settings
This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
Out-of-Band Mgmt Port
The feature selects a serial port in a client server to be used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote host server. The options are COM1 and SOL/COM2.
Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII character set. Select VT100+ to add color and function key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-
UTF8, and ANSI.
Bits Per Second
This item sets the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 57600, and 115200 (bits per second).
Flow Control
Use this item to set the ow control for Console Redirection to prevent data loss caused by buffer overow. Send a "Stop" signal to stop sending data when the receiving buffer is full.
Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None, Hardware RTS/CTS, and Software Xon/Xoff.
Data Bits
Parity
Stop Bits
ACPI Settings
High Precision Event Timer
Select Enabled to activate the High Performance Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Disabled and Enabled.
82
Page 83
Chapter 4: BIOS
WHEA Support
Select Enabled to support the Windows Hardware Error Architecture (WHEA) platform and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring. The options are Disabled and Enabled.
Trusted Computing
Security Device Support
If this feature and the TPM jumper on the motherboard are both set to Enabled, onbaord
security devices will be enabled for TPM (Trusted Platform Module) support to enhance data integrity and network security. Please reboot the system for a change on this setting to take effect. The options are Disable and Enable.
*If the item above set to Enable, the following items will become available for user's
conguration:
TPM State
This feature changes the TPM State. The options are Disabled and Enabled. Note: The system will restart to change the TPM State.
Pending TPM operation
Use this item to schedule a TPM-related operation to be performed by a security device for system data integrity. Your system will reboot to carry out a pending TPM operation. The options are None and TPM Clear.
Device Select
Use this feature to select the TPM version. TPM 1.2 will restrict support to TPM 1.2 devices. TPM 2.0 will restrict support for TPM 2.0 devices. Select Auto to enable support for both versions. The default setting is Auto.
The following are informational status messages that indicate the current TPM State:
TPM Enabled Status
TPM Active Status
TPM Owner Status
TXT Support
Intel TXT (Trusted Execution Technology) helps protect against software-based attacks and
ensures protection, condentiality and integrity of data stored or created on the system. Use
this feature to enable or disable TXT Support. The options are Disabled and Enabled.
83
Page 84
X11SSV-M4F User's Manual
iSCSi Conguration
iSCSI Initiator Name
This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format.
Once the name of the iSCSI Initiator is entered into the system, congure the proper settings
for the following items.
Add an Attempt
Delete Attempts
Change Attempt order
84
Page 85
4.4 Event Logs
Use this feature to congure Event Log settings.
Chapter 4: BIOS
Change SMBIOS Event Log Settings
Enabling/Disabling Options
SMBIOS Event Log
Change this item to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Enabled and Disabled.
Erasing Settings
Erase Event Log
If No is selected, data stored in the event log will not be erased. Select Yes, Next Reset, data in the event log will be erased upon next system reboot. Select Yes, Every Reset, data in the event log will be erased upon every system reboot. The options are No, Yes, Next reset, and Yes, Every reset.
When Log is Full
Select Erase Immediately for all messages to be automatically erased from the event log when the event log memory is full. The options are Do Nothing and Erase Immediately.
85
Page 86
X11SSV-M4F User's Manual
SMBIOS Event Long Standard Settings
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of occurences that a duplicate event must happen before the MECI counter is incremented. This is a numeric value. The default value is 1.
METW
The Multiple Event Time Window (METW) denes number of minutes must pass between
duplicate log events before MECI is incremented. This is in minutes, from 0 to 99. The default value is 60.
Note: After making changes on a setting, be sure to reboot the system for the changes to take effect.
View SMBIOS Event Log
This section displays the contents of the SMBIOS Event Log.
86
Page 87
Chapter 4: BIOS
4.5 IPMI
Use this feature to congure Intelligent Platform Management Interface (IPMI) settings.
BMC Firmware Revision
This item indicates the IPMI rmware revision used in your system.
IPMI Status
This item indicates the status of the IPMI rmware installed in your system.
System Event Log
Enabling/Disabling Options
SEL Components
Select Enabled for all system event logging at bootup. The options are Enabled and Disabled.
Erasing Settings
Erase SEL
Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset.
87
Page 88
X11SSV-M4F User's Manual
When SEL is Full
This feature allows the user to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately.
Note: After making changes on a setting, be sure to reboot the system for the changes to take effect.
BMC Network Conguration
BMC Network Conguration
IPMI LAN Selection
This item displays the IPMI LAN setting. The default setting is Failover.
IPMI Network Link Status
This item displays the IPMI Network Link status. The default setting is Dedicated LAN.
Update IPMI LAN Conguration
Select Yes for the BIOS to implement all IP/MAC address changes at the next system boot. The options are No and Yes.
*If the item above set to Yes, the following item will become available for user's
conguration:
Conguration Address Source
This feature allows the user to select the source of the IP address for this computer. If Static is selected, you will need to know the IP address of this computer and enter it to the system
manually in the eld. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Conguration Protocol) server in the network that is attached to and request the next available
IP address for this computer. The options are DHCP and Static.
Conguration Address Source
This item displays the current conguration address for this computer.
Station IP Address
This item displays the Station IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
Subnet Mask
This item displays the sub-network that this computer belongs to. The value of each three­digit number separated by dots should not exceed 255.
88
Page 89
Chapter 4: BIOS
Station MAC Address
This item displays the Station MAC address for this computer. Mac addresses are 6 two-digit hexadecimal numbers.
Gateway IP Address
This item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 172.31.0.1).
VLAN
This item displays the VLAN information for this computer.
89
Page 90
X11SSV-M4F User's Manual
4.6 Security
This menu allows the user to congure the following security settings for the system.
Password Check
Select Setup for the system to check for a password at Setup. Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility. The options are
Setup and Always.
Administrator Password
Press Enter to create a new, or change an existing Administrator password.
Secure Boot Menu
This section displays the contents of the following secure boot features:
System Mode
Secure Boot
Vendor Keys
Secure Boot
Use this item to enable secure boot. The options are Disabled and Enabled.
90
Page 91
Chapter 4: BIOS
Secure Boot Mode
Use this item to select the secure boot mode. The options are Standard and Custom.
CSM Support
Select Enabled to support the EFI Compatibility Support Module (CSM), which provides compatibility support for traditional legacy BIOS for system boot. The options are Disabled and Enabled.
Key Management
This submenu allows the user to congure the following Key Management settings.
Provision Factory Default Keys
Select Enabled to install the default Secure-Boot keys set by the manufacturer. The options are Disabled and Enabled.
Enroll All Factory Default Keys
Select Yes to install all default secure keys set by the manufacturer. The options are Yes and No.
Save All Secure Boot Variables
This feature allows the user to decide if all secure boot variables should be saved.
Platform Key (PK)
This feature allows the user to congure the settings of the platform keys.
Set New Key
Select Yes to load the new platform keys (PK) from the manufacturer's defaults. Select No to load the platform keys from a le. The options are Yes and No.
Key Exchange Key
Set New Key
Select Yes to load the KEK from the manufacturer's defaults. Select No to load the KEK from
a le. The options are Yes and No.
Append Key
Select Yes to add the KEK from the manufacturer's defaults list to the existing KEK. Select
No to load the KEK from a le. The options are Yes and No.
Authorized Signatures
Set New Key
Select Yes to load the database from the manufacturer's defaults. Select No to load the DB
from a le. The options are Yes and No.
91
Page 92
X11SSV-M4F User's Manual
Append Key
Select Yes to add the database from the manufacturer's defaults to the existing DB. Select
No to load the DB from a le. The options are Yes and No.
Forbiden Signatures
Set New Key
Select Yes to load the DBX from the manufacturer's defaults. Select No to load the DBX from
a le. The options are Yes and No.
Append Key
Select Yes to add the DBX from the manufacturer's defaults to the existing DBX. Select No
to load the DBX from a le. The options are Yes and No.
Authorized TimeStamps
Set New Key
Select Yes to load the DBT from the manufacturer's defaults. Select No to load the DBT from
a le. The options are Yes and No.
Append Key
Select Yes to add the DBT from the manufacturer's defaults list to the existing DBT. Select
No to load the DBT from a le. The options are Yes and No.
OsRecovery Signature
This item uploads and installs an OSRecovery Signature. You may insert a factory default
key or load from a le. The le formats accepted are:
1) Public Key Certicate
a. EFI Signature List
b. EFI CERT X509 (DER Encoded)
c. EFI CERT RSA2048 (bin)
d. EFI SERT SHA256 (bin)
2) EFI Time Based Authenticated Variable
When prompted, select "Yes" to load Factory Defaults or "No' to load from a le.
Delete OSRecovery Signatures
This item deletes a previously installed OS Recovery Signature.
Append OsRecovery Signature
This item uploads and adds an OSRecovery Signature into the Key Management. You may
insert a factory default key or load from a le. When prompted, select "Yes" to load Factory Defaults or "No' to load from a le.
92
Page 93
4.7 Boot
Use this feature to congure Boot Settings:
Chapter 4: BIOS
Boot Mode Select
Use this item to select the type of device that the system is going to boot from. The options are Legacy, UEFI, and Dual. The default setting is Dual.
Fixed Boot Order Priorities
This option prioritizes the order of bootable devices that the system to boot from. Press <Enter> on each entry from top to bottom to select devices.
*If the item above set to Legacy, UEFI, or Dual the following items will be displayed:
Dual Boot Order #1
Dual Boot Order #2
Dual Boot Order #3
Dual Boot Order #4
Dual Boot Order #5
Dual Boot Order #6
Dual Boot Order #7
93
Page 94
X11SSV-M4F User's Manual
Dual Boot Order #8
Dual Boot Order #9
Dual Boot Order #10
Dual Boot Order #11
Dual Boot Order #12
Dual Boot Order #13
Dual Boot Order #14
Dual Boot Order #15
Delete Boot Option
Use this feature to remove a pre-dened boot device from which the system will boot during
startup.
The settings are [any pre-dened boot device].
NETWORK Drive BBS Priorities
This feature allows the user to specify which UEFI network drive devices are boot devices.
Legacy Boot Order #1
UEFI Application Boot Priorities
This feature allows the user to specify which UEFI devices are boot devices.
UEFI Boot Order #1
94
Page 95
Chapter 4: BIOS
4.8 Save & Exit
Select the Exit tab from the BIOS setup utility screen to enter the Exit BIOS Setup screen.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes to the
system conguration and reboot the computer. Select Discard Changes and Exit from the
Exit menu and press <Enter>.
Save Changes and Reset
When you have completed the system conguration changes, select this option to leave the BIOS setup utility and reboot the computer, so the new system conguration parameters can
take effect. Select Save Changes and Exit from the Exit menu and press <Enter>.
Save Changes
After completing the system conguration changes, select this option to save the changes
you have made. This will not reset (reboot) the system.
Discard Changes
Select this option and press <Enter> to discard all the changes and return to the AMI BIOS utility Program.
95
Page 96
X11SSV-M4F User's Manual
Default Options
Restore Optimized Defaults
To set this feature, select Restore Optimized Defaults from the Save & Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance.
Save As User Defaults
To set this feature, select Save as User Defaults from the Exit menu and press <Enter>. This enables the user to save any changes to the BIOS setup for future use.
Restore User Defaults
To set this feature, select Restore User Defaults from the Exit menu and press <Enter>. Use
this feature to retrieve user-dened settings that were saved previously.
Boot Override
Listed on this section are other boot options for the system (i.e., Built-in EFI shell). Select an option and press <Enter>. Your system will boot to the selected boot option.
96
Page 97
Appendix A: BIOS Codes
Appendix A
BIOS Codes
A.1 BIOS Error POST (Beep) Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The numbers on the fatal error list (on the following page) correspond to the number of beeps for the corresponding error. All errors listed, with the exception of Beep Code 8, are fatal errors.
BIOS Beep (POST) Codes
Beep Code Error Message Description
1 beep Refresh Circuits have been reset (Ready to power up)
5 short, 1 long Memory error No memory detected in system
5 long, 2 short Display memory read/write error Video adapter missing or with faulty memory
1 long continuous System OH System overheat condition
97
Page 98
X11SSV-M4F User's Manual
A.2 Additional BIOS POST Codes
The AMI BIOS supplies additional checkpoint codes, which are documented online at http://
www.supermicro.com/support/manuals/ ("AMI BIOS POST Codes User's Guide").
When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20).
For information on AMI updates, please refer to http://www.ami.com/products/.
98
Page 99
Appendix B: Software Installation
Appendix B
Software Installation
B.1 Installing Software Programs
The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp.supermicro.
com. Some of these must be installed, such as the chipset driver.
After accessing the FTP site, go into the CDR_Images directory and locate the ISO le for your motherboard. Download this le to create a CD/DVD of the drivers and utilities it contains. (You may also use a utility to extract the ISO le if preferred.)
After creating a CD/DVD with the ISO les, insert the disk into the CD/DVD drive on your
system and the display shown in Figure B-1 should appear.
Another option is to go to the Supermicro website at http://www.supermicro.com/products/. Find the product page for your motherboard here, where you may download individual drivers
and utilities to your hard drive or a USB ash drive and install from there.
Note: To install the Windows OS, please refer to the instructions posted on our website at http://www.supermicro.com/support/manuals/.
Figure B-1. Driver/Tool Installation Display Screen
99
Page 100
X11SSV-M4F User's Manual
Click the icons showing a hand writing on the paper to view the readme les for each item.
Click a computer icon to the right of an item to install an item (from top to the bottom) one at a time. After installing each item, you must reboot the system before proceeding with the next item on the list. The bottom icon with a CD on it allows you to view the entire contents of the CD.
When making a storage driver diskette by booting into a driver CD, please set the SATA
Conguration to "Compatible Mode" and congure SATA as IDE in the BIOS Setup. After
making the driver diskette, be sure to change the SATA settings back to your original settings.
B.2 SuperDoctor® 5
The Supermicro SuperDoctor 5 is a hardware monitoring program that functions in a command-line or web-based interface in Windows and Linux operating systems. The program monitors system health information such as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs. With SuperDoctor 5 Management Server (SSM Server), you can remotely control power on/off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI. SD5 Management Server monitors HTTP, FTP, and
SMTP services to optimize the efciency of your operation.
Note: The default Username and Password for SuperDoctor 5 is admin / admin.
Figure B-2. SuperDoctor 5 Interface Display Screen (Health Information)
Note: The SuperDoctor 5 program and user’s manual can be downloaded from the
Supermicro website at http://www.supermicro.com/products/nfo/sms_sd5.cfm.
100
Loading...