To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
To avoid electrical shock, do not open the
cabinet. Refer servicing to qualified
personnel only.
For the customers in Europe
This product with the CE marking complies with both the
EMC Directive (89/336/EEC) and the Low Voltage Directive
(73/23/EEC) issued by the Commission of the European
Community.
Compliance with these directives implies conformity to the
following European standards:
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors) and E4 (controlled EMC environment, ex.
TV studio)
Owner’ s Recor d
The model and serial numbers are located at the bottom.
Record these numbers in the spaces provided below.
Refer to these numbers whenever you call upon your Sony
dealer regarding this product.
Model No. Serial No.
For the customers in the U.S.A.
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct
the interference at his own expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.
The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with the
limits for digital device pursuant to Subpart B of Part 15 of
FCC Rules.
2 (GB)
Overview
Table of Contents
The CMA-D3/D3CE camera adaptor is designed to operate
the Sony DXC-390/390P 3CCD color video camera on an
AC or DC power supply.
As the camera adaptor can be connected to the video camera
using the CCMC-3MZ camera cable and a CCZ-A series
camera cable extendable up to 100 m, the video camera can
be installed a considerable distance from a control room.
About this manual
This manual applies to both the CMA-D3 and CMA-D3CE.
The CMA-D3 is designed for the NTSC color system and
can be connected to a DXC-390 video camera. The CMAD3CE is for the PAL color system and can be connected to a
DXC-390P video camera. The operating instructions for
both camera adaptors are the same.
• The unit is designed for operation on a power supply
meeting the requirements indicated in the “Specifications”
on page 13 (GB).
• Do not drop or place heavy objects on the power cord. If
the power cord is damaged, turn off the power
immediately. It is dangerous to use the unit with a
damaged power cord.
• Disconnect the power cord from the AC outlet by grasping
the plug, not by pulling the cord.
• Do not touch the AC power plug with a wet hand.
Keep foreign objects out of the cabinet
Dropping flammable or metal objects into the cabinet, or
spilling liquids nearby can lead to accidents.
In case of malfunctions
If you notice any unusual sound or smell, or smoke, turn off
the power immediately, disconnect the power supply and
contact your Sony dealer.
Handling Precautions
Location
Do not store or use the unit under any of the following
conditions.
• In excessive heat or cold
• In direct sunlight or near a heater
• In damp or dusty locations
• In locations subject to vibrations
• Near strong magnetic fields
• Near a television or radio station generating strong radio
frequency energy
Protect from impact
Do not drop the unit or subject it to severe shocks.
Do not place the unit on an unstable base.
Use of the DC power supply
• Use a DC power supply capable of supplying constant
voltage of 30 W or more.
• As the power switch of this unit does not operate on DC,
install the power switch and fuse on the DC power source
for safety.
4 (GB)
• When connecting the DC power cable to the DC 15 V IN
connector, take special care with the following:
– use a DC power cable of a sufficient current capacity.
– align the polarities correctly.
– make sure that there is no loose connection or short-
circuit on the conductors.
Ventilation
To prevent internal heat buildup, do not block air circulation
around the unit.
Transportation
When transporting the unit, repack it as originally packed at
the factory or in materials equal in quality.
Cleaning
Clean the cabinet and panels by wiping with a soft, dry
cloth. For severe stains, moisten the cloth with a small
amount of neutral solvent, and finish by wiping with a dry
cloth. Do not use alcohol, benzine, thinner or volatile
liquids, as these may discolor or damage the cabinet surface.
5 (GB)
Location and Functions of Parts
Front Panel
1 Power indicator
2 POWER switch
3 CABLE COMP selector
4 REMOTE connector
POWER
ON
OFF
75
50
25
0
CABLE COMP
1 Power indicator
For AC operation, the indicator lights when you set the
POWER switch 2 to ON.
For DC operation, it lights when you supply power to the
DC 15V IN connector on the rear panel.
2 POWER switch
For AC operation, set the switch to ON to turn on the power
of the unit.
6 (GB)
100m
Note
CAMERA ADAPTOR CMA-D3
REMOTE
This illustration shows
the CMA-D3 model.
The POWER switch does not operate when the DC/AC
SELECT switch is set to DC.
3 CABLE COMP (cable compensation) selector
Set the selector to the appropriate position according to the
connected cable length.
4 REMOTE (remote control) connector (mini DIN, 8-
pin)
Connect to the RM-C950 remote control unit (not supplied).