SMA POWER CONTROL MODULE User Manual

Installation Manual
SMA POWER CONTROL MODULE
PWCBRD-10-IA-en-14 | Version 1.4 ENGLISH
Legal Provisions SMA Solar Technology AG
Legal Provisions
The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission.
SMA Warranty
You can download the current warranty conditions from the Internet at www.SMA-Solar.com.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. A lack of identification does not mean that a product or symbol is not trademarked.
The BLUETOOTH and any use of these marks by SMA Solar Technology AG is under license.
Modbus® is a registered trademark of Schneider Electric and is licensed by the Modbus Organization, Inc.
QR Code is a registered trademark of DENSO WAVE INCORPORATED.
®
Phillips
and Pozidriv® are registered trademarks of Phillips Screw Company.
®
Torx
is a registered trademark of Acument Global Technologies, Inc.
SMA Solar Technology AG
Sonnenallee 1 34266 Niestetal Germany
Tel. +49 561 9522-0 Fax +49 561 9522-100 www.SMA.de E-mail: info@SMA.de
© 2004 to 2014 SMA Solar Technology AG. All rights reserved.
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.
2 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG Table of Contents
Table of Contents
1 Information on this Document. . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Validity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Target Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Additional Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.4 Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5 Typography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.6 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Appropriate Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3 Supported Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3 Scope of Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.1 SMA Power Control Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Type Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.1 Mounting Position and Cable Route . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2 Installing the Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.3 Connecting the Ripple Control Receiver . . . . . . . . . . . . . . . . . . . . . . 15
5.4 Information on Module Configuration. . . . . . . . . . . . . . . . . . . . . . . . 19
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.1 Removing the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.2 Packing the Module for Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.3 Disposing of the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
9 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Installation Manual PWCBRD-10-IA-en-14 3
Table of Contents SMA Solar Technology AG
4 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 1 Information on this Document

1 Information on this Document

1.1 Validity

This document is valid for device type "PWCBRD-10" (SMA Power Control Module) from hardware version A1.

1.2 Target Group

The tasks described in this document must be performed by qualified persons only. Qualified persons must have the following skills:
• Training in how to deal with the dangers and risks involved in installing and operating electrical devices and plants
• Training in the installation and commissioning of electrical devices and plants
• Knowledge of all applicable standards and directives
• Knowledge of and adherence to this document and all safety precautions

1.3 Additional Information

Links to additional information can be found at www.SMA-Solar.com:
Document title Document type
Measured Values and Parameters Technical Description

1.4 Symbols

Symbol Explanation
Indicates a hazardous situation which, if not avoided, will result in death or serious injury
Indicates a hazardous situation which, if not avoided, can result in death or serious injury
Indicates a hazardous situation which, if not avoided, can result in minor or moderate injury
Indicates a situation which, if not avoided, can result in property damage
Information that is important for a specific topic or goal, but is not
safety-relevant ☐ Indicates a requirement for meeting a specific goal ☑ Desired result ✖ A problem that might occur
Installation Manual PWCBRD-10-IA-en-14 5
1 Information on this Document SMA Solar Technology AG

1.5 Typography

Typography Explanation Example bold • Display texts
• Elements of a user interface
•Terminals
• Elements to be selected
• Elements to be entered
> • Connects several elements to
be selected
[Button/Key] • B utt on o r ke y to be s ele cted or
pressed
• The value can be read from the Energy field.
• Select Settings.
•Enter the value 10 in the Minutes field.
• Select Settings > Date.
• Select [Next].

1.6 Nomenclature

Complete designation Designation in this document
®
SMA BLUETOOTH SMA Power Control Module Module Sunny Tripower, Windy Tripower Inverter
Wireless Technology BLUETOOTH
6 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 2 Safety

2 Safety

2.1 Appropriate Usage

The SMA Power Control Module is a multifunction interface which enab les grid man ageme nt serv ices to be implemented for one inverter.
The module is available as a retrofit kit or is pre-installed in the inverter. The inverter still complies with the standard after the product has been installed. The module may be used in parallel with the multifunction relay in the inverter. If you want to use the
module at the same time as the multifunction relay in the inverter, you must ensure that no more than 30 V DC or 25 V AC are connected to the multifunction relay.
The relays of the ripple control receiver may only be supplied by the 12 V output of the module. Do not supply the relays of the ripple control receiver with any other voltage sources.
Use this module only in accordance with the enclosed documentation and with the locally applicable standards and directives. Any other use can result in personal injury or property damage.
For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product.
The type label must be permanently attached to the product. The enclosed documentation is an integral part of this product.
• Read and observe the documentation.
• Keep the documentation in a convenient place for future reference.
Installation Manual PWCBRD-10-IA-en-14 7
2 Safety SMA Solar Technology AG

2.2 Safety Precautions

This section contains safety precautions that must be observed at all times when working on or with the product. To prevent personal injury or property damage and to ensure long-term operation of the product, read this section carefully and follow the safety precautions at all times.
Danger to life due to electric shock when opening the inverter
High voltages are present in the live components of the inverter. Touching live components results in death or serious injury.
• Prior to performing any work on the inverter, always disconnect the inverter from all voltage sources on the AC and DC sides (see inverter installation manual). Observe the waiting time to allow the capacitors to discharge.
Risk of burns due to hot enclosure parts
Some parts of the inverter enclosure can get hot during operation. Touching these enclosure parts can result in burn injuries.
• Do not touch any parts other than the lower enclosure lid of the inverter during operation.
Damage to the inverter due to electrostatic discharge
The internal components of the inverter can be irreparably damaged by electrostatic discharge.
• Earth yourself before touching any inverter component.
8 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 2 Safety

2.3 Supported Products

SMA Inverters
The module must only be installed in the following inverters with at least the given firmware version:
Sunny Tripower from firmware version
• STP 5000TL-20 2.51.05.R
• STP 6000TL-20
• STP 7000TL-20
• STP 8000TL-20
• STP 9000TL-20
• STP 10000TL-20
• STP 12000TL-20
Windy Tripower from firmware version
• WTP 5000TL-20 2.51.05.R
• WTP 6000TL-20
• WTP 7000TL-20
• WTP 8000TL-20
• WTP 9000TL-20
all
Additional SMA Products
The module can be configured with the following communication products:
• Sunny Explorer from software version 1.06
• Sunny WebBox with BLUETOOTH from firmware version 1.03
Installation Manual PWCBRD-10-IA-en-14 9
3 Scope of Delivery SMA Solar Technology AG

3 Scope of Delivery

Check the scope of delivery for completeness and any externally visible damage. Contact your specialist dealer if the delivery is incomplete or damaged.
If the module has already been installed in the inverter at the factory, only those parts necessary for electrical connection are included in the scope of delivery.
Figure1: Components included in the scope of delivery
Position Number Designation
A 1 SMA Power Control Module* B1Five-pole plug C1Twp-pole plug** D 1 M4x10 screw* E2Plastic spacer* F1Metal spacer* G 1 Cable support sleeve with two holes for M25 cable gland** H 1 Installation manual
* Only included in the scope of delivery of the retrofit kit
** Store the components for the connection to the S0 interface until the S0 interface is allocated.
10 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 4 Product Description

4 Product Description

4.1 SMA Power Control Module

The SMA Power Control Module is a multifunction interface which enab les grid man ageme nt serv ices to be implemented for one inverter.
For the implementation of grid management services, the module receives the specifications of the network operator via a ripple control receiver.
The module can convert the active power limitation in staged intervals of 0%, 30%, 60% and 100% of the agreed connected load.
Figure2: Design of the SMA Power Control Module
Position Designation
A Holes for attachment with plastic spacers B Socket for connecting to the S0 interface* C Socket for connecting the ripple control receiver D Hole for attachment with the metal spacer EType label
* The S0 interface is not allocated.
Installation Manual PWCBRD-10-IA-en-14 11
4 Product Description SMA Solar Technology AG

4.2 Type Label

The type label clearly identifies the product. The type label is located on the front of the product.
Figure3: Layout of the type label (example)
Position Designation Explanation
A FA Number of the production order B‒ Hardware version C‒ Device type DSER Serial number
Yo u wi ll r equ ire the inf ormatio n on the typ e la bel to u se t he p roduct safely and when seeking customer support from the SMA Service Line.
12 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 5 Electrical Connection

5 Electrical Connection

5.1 Mounting Position and Cable Route

Figure4: Mounting position and cable route in the inverter with the enclosure lid open
Position Designation
A Holes for inserting the plastic spacers BCable route C Hole for screwing in the metal spacer D Socket for plugging in the module E Mounting position
Installation Manual PWCBRD-10-IA-en-14 13
5 Electrical Connection SMA Solar Technology AG

5.2 Installing the Module

Damage to the inverter due to electrostatic discharge
The internal components of the inverter can be irreparably damaged by electrostatic discharge.
• Earth yourself before touching any inverter component.
Procedure:
1. Ensure that the firmware version of the inverter is supported (see Section2.3, page9). If necessary, update the firmware of the inverter (see the inverter installation manual).
2.
Danger to life due to electric shock when opening the inverter
High voltages are present in the live components of the inverter. Touching live components results in death or serious injury.
• Disconnect the inverter from all voltage sources on the AC and DC sides (see the inverter installation manual). Observe the waiting time to allow the capacitors to discharge.
3. Attach all spacers in the inverter:
• Insert the plastic spacers into the holes.
• Screw the metal spacer into the screw connection (torque: 3.5 Nm).
4. Insert the module into the inverter. Insert the plug at the bottom of the module into the socket and lead the spacers through the holes in the module.
14 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 5 Electrical Connection
5. Fasten the module using the screw M4x10 and a Torx screwdriver (T 20) (torque: 1.5 Nm).

5.3 Connecting the Ripple Control Receiver

Additionally required material (not included in scope of delivery):
☐ Ripple control receiver with at least three outputs ☐ One connection cable
Cable requirements:
☐Cable cross-section: 5 mm to 13 mm ☐ Conductor cross-section: 0.5 mm² to 1.5 mm² ☐ Maximum cable length: 100 m ☐ Cables to be laid outdoors must be UV-resistant or routed in a UV-resistant cable channel. ☐ Required number of insulated wires for connecting the ripple control receiver: five insulated
wires
Figure5: Wiring overview for a ripple control receiver with four relays (example)
Installation Manual PWCBRD-10-IA-en-14 15
5 Electrical Connection SMA Solar Technology AG
Value
communication product
D1: 0| D2: 0| D3: 0| D4: 1 100%
Open Closed Open Open D1: 0| D2: 1| D3: 0| D4: 0 30%
Open Open Open Open D1: 0| D2: 0| D3: 0| D4: 0 − 1%**
Closed Open Open Open D1: 1| D2: 0| D3: 0| D4: 0 0%
Digital input D1 Digital input D2 Digital input D3 Digital input D4 Display in the
Functions of Signals D1 to D4 in Operating Mode "Active Power Limitation" (Default Settings)
16 PWCBRD-10-IA-en-14 Installation Manual
Closed Closed Open Open D1: 1| D2: 1| D3: 0| D4: 0 − 1%**
Open Open Closed Open D1: 0| D2: 0| D3: 1| D4: 0 60%
Closed Open Closed Open D1: 1| D2: 0| D3: 1| D4: 0 − 1%**
Open Closed Closed Open D1: 0| D2: 1| D3: 1| D4: 0 − 1%**
Closed Closed Closed Open D1: 1| D2: 1| D3: 1| D4: 0 − 1%**
Open Open Open Closed*
Closed Open Open Closed D1: 1| D2: 0| D3: 0| D4: 1 − 1%**
Open Closed Open Closed D1: 0| D2: 1| D3: 0| D4: 1 − 1%**
Closed Closed Open Closed D1: 1| D2: 1| D3: 0| D4: 1 − 1%**
Open Open Closed Closed D1: 0| D2: 0| D3: 1| D4: 1 − 1%**
Closed Open Closed Closed D1: 1| D2: 0| D3: 1| D4: 1 − 1%**
Open Closed Closed Closed D1: 0| D2: 1| D3: 1| D4: 1 − 1%**
Closed Closed Closed Closed D1: 1| D2: 1| D3: 1| D4: 1 − 1%**
* Not used for ripple control receivers with three relays
** The value " − 1%" blocks the entry combination.
SMA Solar Technology AG 5 Electrical Connection
Damage to the module due to high voltage
• Only connect a ripple control receiver with a relay that is exclusively supplied by the 12 V output of the module.
Operating the SMA Power Control Module and the multifunction relay in the inverter in parallel
• If you want to operate the SMA Power Control Module and the multifunction relay in parallel, make sure that no more than 30 V DC or 25 V AC are connected to the multifunction relay.
Procedure:
1.
Danger to life due to electric shock from faulty connection of the ripple control receiver
In the event of faulty connection of the connection cable to the ripple control receiver, mains voltage may be present in the module.
• Do not connect insulated wires of the connection cable to the phase conductors of the ripple control receiver.
• When connecting, ensure that no bridge is being used in the ripple control receiver.
2. Dismantle the connection cable by 4 cm.
3. Trim unused insulated wires flush with the cable sheath.
4. Strip the wire insulation by 6 mm.
5. Connect the connection cable to the ripple control receiver (see ripple control receiver manual) and write down the wire colours.
Signal Insulated wire colour
D1 D2 D3 D4 +12 V
6. If you want to insert two cables through the cable gland M25 of the inverter, remove the cable support sleeve of the cable gland. If necessary, loosen the swivel nut of the cable gland.
7. Lead the connection cable through the cable support sleeve with t wo h ole s an d th e ca ble gla nd. Push the cable support sleeve with two holes into the cable gland.
Installation Manual PWCBRD-10-IA-en-14 17
5 Electrical Connection SMA Solar Technology AG
8. Remove the protective cover of the multifunction relay and insert the cable through the opening of the protective cover.
9.
Danger to life due to live cables
If an insulated wire, e.g. L1, L2 or L3 comes loose from the AC terminal, and touches the connection cable of the ripple control receiver for example, the connection cable is live.
• Attach the protective cover of the multifunction relay. This isolates the AC connection area in the inverter from other terminals.
10. Plug the five-pole plug into the DIGITAL socket on the module.
11. Connect the connection cable to the five-pole plug. Plug the conductor into the conductor entry. Make sure that the noted wire colours correspond.
12. Tighten the swivel nut hand-tight on the cable gland.
13. Recommission the inverter (see inverter installation manual).
18 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 5 Electrical Connection

5.4 Information on Module Configuration

Active power reduction to one of the 16 values set is realised within five seconds in the inverter. Grid disconnection is possible within two seconds. In order to block an entry combination, the value " − 1%" mus t be set in t he c ommu nic ati on p rod uct (se e ta ble on p age 16). This allows that unassigned entry combinations can be blocked.
If the network operator does not allow that the inverter still feeds in a low amount of active power when limited to 0%, you must set the following parameter for grid disconnection. Setting this parameter additionally opens the grid relays at a command of 0%. The inverter disconnects from the electricity grid and grid feed-in is interrupted. Depending on the type of communication and the communication product used, the parameter name may vary:
Type of
Parameter name Setting
communication BLUETOOTH Equipment & device control system >
Configuration of the feed-in management >
Yes
No
Grid disconn. at 0% specif. by feeding management
RS485 P-GriSwOpnZerW Yes
No
When the parameter is activated (Yes), the inverter disconnects from the electricity grid when the signal "0%" is issued. When the parameter is deactivated (No), the inverter continues to feed in with minimum power when the signal "0%" is issued.
Installation Manual PWCBRD-10-IA-en-14 19
6 Troubleshooting SMA Solar Technology AG

6 Troubleshooting

Problem Cause and corrective measures
The inverter with module is not displayed in Sunny Explorer.
The inverter with module has not been commissioned.
Corrective measure:
• Commission the inverter with module (see the inverter installation manual).
The module is not properly installed.
Corrective measure:
• E nsu re that the module i s in stalle d co rrectly and th at the connections have been made correctly.
The firmware version of the inverter is not supported (see Section2.3 "Supported Products", page9).
Corrective measure:
• Update the firmware of the inverter (see the inverter installation manual).
The software version of Sunny Explorer is older than version 1.06.
Corrective measure:
• Make sure that Sunny Explorer from software version 1.06 is installed on the computer.
20 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 7 Decommissioning

7 Decommissioning

7.1 Removing the Module

Damage to the inverter due to electrostatic discharge
The internal components of the inverter can be irreparably damaged by electrostatic discharge.
• Earth yourself before touching any components.
Procedure:
1.
Danger to life due to electric shock when opening the inverter
High voltages are present in the live components of the inverter. Touching live components results in death or serious injury.
• Disconnect the inverter from all voltage sources on the AC and DC sides (see the inverter installation manual). Observe the waiting time to allow the capacitors to discharge.
2. Remo ve the insulated wires of the co nnect ion cable from the multi-pole plug. Insert a flat-blade screwdriver (blade width: max. 3 mm) into the actuation lever and take out the insulated wires.
3. Remove the multi-pole plug of the ripple control receiver from the module.
4. Slightly loosen the swivel nut of the cable gland and remove the connection cable from the inverter.
Installation Manual PWCBRD-10-IA-en-14 21
7 Decommissioning SMA Solar Technology AG
5. Loosen the screw M4x10 fastening the module to the inverter using a Torx screwdriver (T 20).
6. Remove the module from the inverter. The spacers remain in the inverter.
7. Close the inverter and recommission it (see the inverter installation manual).

7.2 Packing the Module for Shipment

• Pack the module for shipment. Use the original packaging or packaging that is suitable for the weight and size of the module (see Section8 "Technical Data", page23).

7.3 Disposing of the Module

• Dispose of the module in accordance with the disposal regulations for electronic waste applicable at the installation site.
22 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 8 Technical Data

8 Technical Data

Inputs
Ripple control receiver 4 digital inputs S0 interface No function
Voltage Supply
Voltage supply Via the inverter
General Data
Dimensions (width x height x depth) 127 mm x 77 mm x 39 mm Weight 55 g Mounting location In the inverter Degree of protection according to IEC 60529 IP20 Required degree of protection of the inverter
according to IEC 60629
Ambient Conditions for Storage/Transport
Ambient temperature − 40°C to +70°C Relative humidity, non-condensing 10% to 95% Maximum height above mean sea level 3,000 m
IP65
Ambient Conditions during Operation
Ambient temperature − 25°C to +85°C Relative humidity, non-condensing 4% to 100% Maximum height above mean sea level 3,000 m
Installation Manual PWCBRD-10-IA-en-14 23
9 Contact SMA Solar Technology AG

9 Contact

If you have technical problems concerning our products, please contact the SMA Service Line. We require the following data in order to provide you with the necessary assistance:
•Inverter:
– Serial number – Firmware version – Special country-specific settings (if applicable)
•Module:
– Serial number – Hardware version
• Communication product (e.g. Sunny Explorer)
–Type – Serial number or software version
• Detailed description of the problem
Australia SMA Australia Pty Ltd.
Sydney
Belgien/ Belgique/ België
Brasil Vide España (Espanha) Česko SMA Central & Eastern Europe
Chile Ver España Danmark Se Deutschland (Tyskland) Deutschland SMA Solar Technology AG
SMA Benelux BVBA/SPRL Mechelen
s.r.o. Praha
Niestetal
Toll free for Australia:
International: +61 2 9491 4200 +32 15 286 730
+420 235 010 417
Medium Power Solutions Wechselrichter:
Kommunikation: SMA Online Service Center:
www.SMA.de/Service Hybrid Energy Solutions Sunny Island: +49 561 9522-399 PV-Diesel
Hybridsysteme: Power Plant Solutions Sunny Central: +49 561 9522-299
1800 SMA AUS (1800 762 287)
+49 561 9522-1499 +49 561 9522-2499
+49 561 9522-3199
24 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology AG 9 Contact
España SMA Ibérica Tecnología Solar,
S.L.U. Barcelona
France SMA France S.A.S.
Lyon
India SMA Solar India Pvt. Ltd.
Mumbai
Italia SMA Italia S.r.l.
Milano
Κύπρος/ Kıbrıs
Luxemburg/ Luxembourg
Βλέπε Ελλάδα/ Bkz. Ελλάδα (Yunanistan)
Siehe Belgien
Voir Belgique Magyarország lásd Česko (Csehország) Nederland zie Belgien (België) Österreich Siehe Deutschland Perú Ver España Polska Patrz Česko (Czechy) Portugal SMA Solar Technology Portugal,
Unipessoal Lda
Lisboa România Vezi Česko (Cehia) Schweiz Siehe Deutschland Slovensko pozri Česko (Česká republika) South Africa SMA Solar Technology
South Africa Pty Ltd.
Centurion (Pretoria) United
Kingdom
SMA Solar UK Ltd.
Milton Keynes Ελλάδα SMA Hellas AE
Αθήνα България Вижте Ελλάδα (Гърция)
Llamada gratuita en
900 14 22 22
España: Internacional: +34 902 14 24 24
Medium Power Solutions Onduleurs :
Communication :
+33 472 09 04 40
+33 472 09 04 41 Hybrid Energy Solutions Sunny Island : +33 472 09 04 42 Power Plant Solutions Sunny Central : +33 472 09 04 43 +91 22 61713888
+39 02 8934-7299
Isento de taxas em
800 20 89 87 Portugal:
Internacional: +351 2 12 37 78 60
08600 SUNNY (08600 78669)
International: +27 (12) 643 1785 +44 1908 304899
801 222 9 222 International: +30 212 222 9 222
Installation Manual PWCBRD-10-IA-en-14 25
9 Contact SMA Solar Technology AG

SMA Solar (Thailand) Co., Ltd. +66 2 670 6999
대한민국 SMA Technology Korea Co., Ltd.서울+82 2 508-8599
中国 SMA Beijing Commercial
Company Ltd. 北京
+971 2 234-6177 SMA Middle East LLC
Other countries
International SMA Service Line Niestetal
+86 10 5670 1350
Toll free worldwide: 00800 SMA SERVICE (+800 762 7378423)

!
26 PWCBRD-10-IA-en-14 Installation Manual
SMA Solar Technology
www.SMA-Solar.com
Loading...