The information contained in these documents is the property of SMA Solar Technology AG. No
part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or
by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without the prior
written permission of SMA Solar Technology AG. Internal reproduction used solely for the purpose
of product evaluation or other proper use is allowed and does not require prior approval.
SMA Solar Technology AG makes no representations or warranties, express or implied, with
respect to this documentation or any of the equipment and/or software it may describe, including
(with no limitation) any implied warranties of utility, merchantability, or fitness for any particular
purpose. All such representations or warranties are expressly disclaimed. Neither SMA Solar
Technology AG nor its distributors or dealers shall be liable for any indirect, incidental, or
consequential damages under any circumstances.
The exclusion of implied warranties may not apply in all cases under some statutes, and thus the
above exclusion may not apply.
Specifications are subject to change without notice. Every attempt has been made to make this
document complete, accurate and up-to-date. Readers are cautioned, however, that product
improvements and field usage experience may cause SMA Solar Technology AG to make changes
to these specifications without advance notice, or per contract provisions in those cases where a
supply agreement requires advance notice. SMA Solar Technology AG shall not be responsible for
any damages, including indirect, incidental or consequential damages, caused by reliance on the
material presented, including, but not limited to, omissions, typographical errors, arithmetical errors
or listing errors in the content material.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. Missing designations do not
mean that a product or brand is not a registered trademark.
• SMA RS485 (MD.485-US-40) with assembly designation "PC-485.BG1" from hardware
version A1
1.2Target Group
The tasks described in this document must only be performed by qualified persons. Qualified
persons must have the following skills:
• Knowledge of how an inverter works and is operated
• Training in how to deal with the dangers and risks associated with installing, repairing and
using electrical devices and installations
• Training in the installation and commissioning of electrical devices and installations
• Knowledge of all applicable laws, standards and directives
• Knowledge of and compliance with this document and all safety information
1.3Levels of warning messages
The following levels of warning messages may occur when handling the product.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which, if not avoided, can result in property damage.
1.4Symbols in the Document
SymbolExplanation
Information that is important for a specific topic or goal, but is not safety-relevant
Indicates a requirement for meeting a specific goal
Desired result
Installation ManualMD485-US-40-IA-en-114
SMA Solar Technology AG
✖
SymbolExplanation
A problem that might occur
Example
1 Information on this Document
1.5Typographies in the document
TypographyUseExample
bold
>
[Button]
[Key]
• Messages
• Terminals
• Elements on a user interface
• Elements to be selected
• Elements to be entered
• Connects several elements to be
selected
• Button or key to be selected or
pressed
• Connect the insulated
conductors to the terminals
X703:1 to X703:6.
• Enter 10 in the field
Minutes.
• Select Settings > Date.
• Select [Enter].
1.6Designation in the document
Complete designationDesignation in this document
PV systemPV system
SMA RS485 ModuleModule, product
1.7Additional Information
Title and information contentType of information
"RS485 Cabling Plan"Installation Manual
Installation ManualMD485-US-40-IA-en-115
2 Safety
SMA Solar Technology AG
2Safety
2.1Intended Use
The SMA RS485 Module enables SMA inverters to establish wired RS485 communication.
The SMARS485Module enables SMA inverters of type "SBx.x-1SP-US-40" to establish
communication between the inverter and the energy meter according to ANSIC12.20 of the
SMARevenueGradeMeterKit. The SMARS485 module can be used in SMA inverters of type
"SBx.x-1SP-US-40" only to establish this communication. The setup of a cable-connected RS485
communication to other units is not supported.
The product must only be installed in the following SMA inverters:
• STP50-US-40 (SunnyTripowerCORE1-US)
• STP33-US-41 (SunnyTripowerCORE1-US)
• STP50-US-41 (SunnyTripowerCORE1-US)
• STP62-US-41 (SunnyTripowerCORE1-US)
• SB3.0-1SP-US-40 (Sunny Boy 3.0-US)
• SB3.8-1SP-US-40 (Sunny Boy 3.8-US)
• SB5.0-1SP-US-40 (Sunny Boy 5.0-US)
• SB6.0-1SP-US-40 (Sunny Boy 6.0-US)
• SB7.0-1SP-US-40 (Sunny Boy 7.0-US)
• SB7.7-1SP-US-40 (Sunny Boy 7.7-US)
The inverter still complies with the standard after the product has been installed.
All components must remain within their permitted operating ranges and their installation
requirements at all times.
The product is approved for the US and Canadian market.
Use this product only in accordance with the information provided in the enclosed documentation
and with the locally applicable laws, regulations, standards and directives. Any other application
may cause personal injury or property damage.
Alterations to the product, e.g. changes or modifications, are only permitted with the express written
permission of SMA. Unauthorized alterations will void guarantee and warranty claims and in most
cases terminate the operating license. SMA shall not be held liable for any damage caused by
such changes.
Any use of the product other than that described in the Intended Use section does not qualify as the
intended use.
The enclosed documentation is an integral part of this product. Keep the documentation in a
convenient place for future reference and observe all instructions contained therein.
This document does not replace and is not intended to replace any local, state, provincial, federal
or national laws, regulations or codes applicable to the installation, electrical safety and use of the
product. SMA assumes no responsibility for the compliance or non-compliance with such laws or
codes in connection with the installation of the product.
The type label must remain permanently attached to the product.
Installation ManualMD485-US-40-IA-en-116
SMA Solar Technology AG
2 Safety
2.2IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This section contains safety information that must be observed at all times when working on or with
the product.
The product has been designed and tested in accordance with international safety requirements. As
with all electrical or electronical devices, there are residual risks despite careful construction. To
prevent personal injury and property damage and to ensure long-term operation of the product,
read this section carefully and observe all safety information at all times.
DANGER
Danger to life due to electric shock when live components or cables of the
inverter are touched
High voltages are present in the conductive components or cables of the inverter. Touching live
parts and cables of the inverter results in death or lethal injuries due to electric shock.
• Disconnect the inverter from voltage sources and make sure it cannot be reconnected
before working on the device.
• Wear suitable personal protective equipment for all work on the product.
NOTICE
Damage to the enclosure seal in subfreezing conditions
If you open the inverter when temperatures are below freezing, the enclosure seals can be
damaged. This can lead to moisture entering the inverter.
• Only open the inverter if the ambient temperature is not below -5°C (23°F).
• If a layer of ice has formed on the enclosure seal when temperatures are below freezing,
remove it prior to opening the inverter (e.g. by melting the ice with warm air). Observe the
applicable safety regulations.
NOTICE
Damage to the product due to sand, dust and moisture ingress
Sand, dust and moisture penetration can damage the product and impair its functionality.
• Only open the inverter if the humidity is within the thresholds and the environment is free of
sand and dust.
• Do not open the inverter during a dust storm or precipitation.
• Close tightly all enclosure openings.
• Only use listed rain-tight or liquid-tight conduit fittings to attach the conduits to the product.
NOTICE
Damage to the inverter or product due to electrostatic discharge
Touching electronic components can cause damage to or destroy the inverter or the product
through electrostatic discharge.
• Ground yourself before touching any component.