Parts marked with ““ are important for maintaining the safety of the set.
Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
This document has been published to be used
SHARP CORPORATION
for after sales service only.
The contents are subject to change without notice.
Disconnect the AC cord before servicing the unit.LASER WAVE - LENGTH : 785 15mm
Pulse times : 10.34 s 0.1 s/7mm ; MX-M182, MX-M182D, MX-M202D
3. Note for replacement of consumable parts . . . . . . . . . . . 9 - 2
[1] GENERAL
1. Note for servicing
Pictogram
The label () in the fusing area of the machine indicates the
following:
: Caution, risk of danger
: Caution, hot surface
•poorly ventilated
A. Warning for servicing
•The fusing area is hot. Exercise care in this area when removing
misfeed paper.
•Do not disassemble the laser unit. Do not insert a reflective material
such as a screwdriver in the laser beam path.
It may damage eyes by reflection of laser beams.
B. Cautions for servicing
•Do not switch the machine rapidly on and off. After turning the machine
off, wait 10 to 15 seconds before turning it back on.
•Machine power must be turned off before installing any supplies.
•Place the machine on a firm, level surface.
•Do not install the machine in a humid or dusty location.
•When the machine is not used for a long time, for example, during
prolonged holidays, turn the power switch off and remove the power
cord from the outlet.
•When moving the machine, be sure to turn the power switch off and
remove the power cord from the outlet.
•Do not cover the machine with a dust cover, cloth or plastic film while the
power is on. Doing so may prevent heat dissipation, damaging the
machine.
•Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous laser radiation
exposure.
•The socket-outlet shall be installed near the machine and shall be easily
accessible.
C. Note for installation place
Improper installation may damage the machine. Please note the
following during initial installation and whenever the machine is moved.
Caution : If the machine is moved from a cool place to a warm place,
condensation may form inside the machine. Operation in this
condition will cause poor copy quality and malfunctions. Leave
the machine at room temperature for at least 2 hours before
use.
Do not install your machine in areas that are:
•damp, humid, or very dusty
•exposed to direct sunlight
•subject to extreme temperature or humidity changes, e.g., near an air
conditioner or heater.
The machine should be installed near an accessible power outlet for
easy connection and disconnection.
Be sure to connect the power cord only to a power outlet that meets the
specified voltage and current requirements. Also make certain the outlet
is properly grounded.
Note : Connect the machine to a power outlet which is not used for other
electric appliances. If a lighting fixture is connected to the same
outlet, the light may flicker.
Be sure to allow the required space around the machine for servicing
and proper ventilation.
20 cm (8
"
)
MX-M182 GENERAL 1-1
20 cm
"
)
(8
20 cm
(8
"
)
D. Note for handling PWB and electronic parts
When handling the PWB and the electronic parts, be sure to observe the
following precautions in order to prevent against damage by static
electricity.
1) When in transit or storing, put the parts in an anti-static bag or an
anti-static case and do not touch them with bare hands.
2) When and after removing the parts from an anti-static bag (case),
use an earth band as shown below:
•Put an earth band to your arm, and connect it to the machine.
3) When repairing or replacing an electronic part, perform the
procedure on an anti-static mat.
A4/8.5" x 11"23ppm20ppm18ppm
A4R/8.5" x 11"R15/16ppm14/15ppm14/15ppm
A5/5.5"x8.5"23ppm20ppm18ppm
B5/16K23ppm20ppm18ppm
B5R/16KR18/16ppm16/15ppm16/15ppm
S to S18cpm (78%)18cpm (90%)15cpm (83%)
S to D10cpm (43%)10cpm (50%)10cpm (56%)
D to D10cpm (43%)10cpm (50%)10cpm (56%)
S to S : A4/8.5" x 11" document 10 sheets, copy 5 sets
S to D : A4/8.5" x 11" document 10 sheets, copy 5 sets
D to D : A4/8.5" x 11" document 10 sheets (20 pages), copy 5 sets
Note :The temperature at the end portion of the heat roller may rise too
high, depending on the kind of paper to be used, when in
continuous printing of small-size paper.
To avoid this, when the thermistor at the end portion detects a
higher temperature than the specified level, output is stopped
temporarily.
During temporary stop, Power Save Indicator lamp flashes in the
same manner as warming up.
MX-M182
MX-M182D
(5) First copy time
Tr ay18/20cpm machine23cpm machine
1st tray7.2 sec or less5.9 sec or less
AE mode, A4/Letter, single surface copy with OC, in polygon ready state
D. Document
Max. document sizeA3, 11" x 17"
Document reference positionUpper left-hand corner
Detection (Platen)Ye s
E. Paper feed
(1) Paper feed section details
Item1st tray2nd tray*1
Paper capacity250 sheets 250 sheets 100 sheets
Paper size detectionNo
Paper type settingNoNoNo
Paper size changing methodThe paper guide is set by the user.
Default paper size
when shipping
Remaining paper quantity
detection
*1: 2-stage standard only for the MX-M202D/M232D
AB seriesA4A4Inch series
(Paper size is set with
the operasion panel.)
8 1/2" x11" 8 1/2" x11"
Only empty detection available
Bypass tray
(Heavy
paper setting
is enabled.)
-
(2) Engine performance when printing
Model23cpm machine 20cpm machine 18cpm machine
ROPM OFF12ppm or more12ppm or more12ppm or more
ROPM ON23ppm20ppm18ppm
(3) Document replacement speed (Copy mode)
Copy modeMX-M232DMX-M202D
S to S20cpm (87%)20cpm (100%)18cpm (100%)
S to S : A4/8.5" x 11" document 11 sheets, copy 1 set (Excluding the first
copy)
MX-M182
MX-M182D
MX-M182 SPECIFICATIONS 3-1
(2) Feedable paper
Paper size1st tray 2nd tray
A3297x420Ye sYesYe s
B4257x364Ye sYesYe s
A4297x210Ye sYesYe s
A4-R210x297Ye sYe sYe s
B5257x182Ye sYesYe s
B5R182x257Ye sYe sYe s
A5210x148.5Ye sN/AYe s
A5R148.5x210N/AN/AYe s
A6R105x148.5N/AN/AYe s
B6R128.5x182N/AN/AYe s
Ledger 11x17 in279.4x431.8Ye sYe sYes
Legal 8.5x14in.215.9x355.6Ye sYe sYe s
8.5x13.4 *1216x340 *1*1*1*1
Foolscap 8.5x13 in215.9x330.2Ye sYe sYes
Letter 11x8.5in279.4x215.9Ye sYe sYe s
Letter-R 8.5x11in215.9x279.4Ye sYe sYes
Executive-R 7.25x10.5in. 184.2x266.7N/AN/AYe s
Invoice 8.5x5.5 in.215.9x139.7Ye sN/AYe s
Invoice-R 5.5x8.5 in139.7x215.9N/AN/AYe s
8K270x390Ye sYe sYe s
16K270x195Ye sYe sYe s
16KR195x270Ye sYe sYe s
COM10104.8x241.3N/AN/AYe s
*1: Switches by SIM26-2. (Operation UI supports by 8.5x13 and exclusion.)
Bypass
tray
(3)Types of feedable paper
Types of paper1st tray 2nd trayBypass tray
Thin paper56-59g/m
15-15.9lbs
Plain paper60-90g/m
16-24lbs
Heavy paper 91-105g/m
16-24lbs
Heavy paper 106-128g/m
24.1-33.5lbs
Heavy paper 129-200g/m
33.6-53.2lbs
Heavy paper 201-256g/m
53.3-68lbs
Envelope75-90g/m
20-24lbs
PostcardN/AN/AYe s
OHP filmN/AN/AYe s
Label sheetN/AN/AYe s
Tab paper 20N/AN/AN/A
development
Charging systemSaw teeth charging
Transfer system(+) DC corotron
Separation system(-) DC corotron
Fusing systemHeat roller
Cleaning systemContact blade
O. Package form
BodyBody / Accessories
O
P. E xtern al vi ew
External dimensions
(With the bypass tray closed)
Occupying area
(With the bypass tray opened)
Weight
(Excluding developer)
Standard modelD model
591mm(W) x 573mm(D)
883mm(W) x 573mm(D)
1-tray model:
29.4kg
1-tray model:
29.6kg (OC)
2-tray model:
35.0kg (OC)
1-tray model:
33.2kg (RSPF)
2-tray model:
38.6kg (RSPF)
Q. Power source
Voltage100 - 127V 220 - 240V
Frequency50/60Hz common
R. Power consumption
Max. power consumption1200W
S. Digital performance
ResolutionReading400 x 600dpi (PHOTO mode)
Writing600 x 600dpi
GradationReading256 gradations
WritingBinary
Memory (MAX)256MB (with MX-EB14)
Hard diskNone
400 x 600dpi (AUTO exposure mode)
400 (main) x 600 (sub) dpi (TEXT mode)
MX-M182 SPECIFICATIONS 3-3
2. Print mode
A. Printing function
(1) Platform
ItemContent
Support platformIBM PC/AT compatible machine
(2) Support OS
Main unitWhen MX-NB12 is installed
OS
Windows98/MeNoNoNoNoNoNoNo
NT 4.0 SP5 or laterNoNoNoNoNoNoNo
2000CD-ROMCD-ROMCD-ROMNoCD-ROMCD-ROMCD-ROM
XPCD-ROMCD-ROMCD-ROMNoCD-ROMCD-ROMCD-ROM
XPx64CD-ROMCD-ROMCD-ROMNoCD-ROMCD-ROMCD-ROM
Server 2003NoNoCD-ROMNoCD-ROMCD-ROMCD-ROM
Server 2003x64NoNoCD-ROMNoCD-ROMCD-ROMCD-ROM
VistaCD-ROMCD-ROMCD-ROMNoCD-ROMCD-ROMCD-ROM
Vistax64CD-ROMCD-ROMCD-ROMNoCD-ROMCD-ROMCD-ROM
Server 2008NoNoCD-ROMNoCD-ROMCD-ROMCD-ROM
Server 2008x64NoNoCD-ROMNoCD-ROMCD-ROMCD-ROM
Windows 7CD-ROMCD-ROMCD-ROMNoCD-ROMCD-ROMCD-ROM
Windows 7x64CD-ROMCD-ROMCD-ROMNoCD-ROMCD-ROMCD-ROM
Mac9.0-9.2.2NoNoNoNoNoNoNo
X 10.2.8NoNoNoNoNoWebNo
X 10.3.9NoNoNoNoNoWebNo
X 10.4.11NoNoNoNoNoCD-ROMNo
X 10.5- 10.5.8NoNoNoNoNoCD-ROMNo
X 10.6-10.6.4NoNoNoNoNoCD-ROMNo
Twain/Button
Manager
SPLC
Custom
PCL6
Custom
PCL5e
Custom
PS
PPDPC-FAX
When MX-FX13 is
installed
(3) Printer driver function
a. Windows version of SPLC driver
FunctionOverseasDescription
MainCopies1-999Perform specified numbers of printing.
CollateCollate
Document Style1-sided
N-up2/4/6Specified numbers of pages are printed on one sheet.
N-up OrderZ
N-up BorderYes / N oPartition line is added for the plural pages printed on 1 sheet.
User SettingAdd/DeleteRegister the setting value for commonly-used driver.
Image OrientationPortrait
Rotate 180 DegreeYes / N oRotate data 180 degrees to print.
Ye s / N oPrint size is changed according to the specified contents.
DL / C5
Bypass (Auto)
Bypass (Manual)
Tray 1/2 (3/4)
If "Collate" is specified, plural printing by the number of set is done,
and "Uncollate" is specified, plural printing by page is done.
Simplex or duplex printing is done depending on the setting.
Print direction is different depending on book/tablet for duplex
printing. (* Simplex model have no duplex function.)
Print in the specified print direction.
Print in the specified paper size. Even if actual paper size is different
from the specified paper size, the image is created in the specified
paper size to print.
Length: 148 - 431.8mm
Paper is fed from the specified paper feed tray.
MX-M182 SPECIFICATIONS 3-4
FunctionOverseasDescription
Advanced Brightness
(Image adjustment)
0 - 100%Adjust the brightness of the image by moving the scale within the
range of 0-100. The illustration image at the upper left of the screen
changes by this adjustment.
Contrast
(Image adjustment)
0 - 100%.Adjust the contrast of the image by moving the scale within the range
of 0-100. The illustration image at the upper left of the screen
changes by this adjustment
Text To B l a ckYes / N oPrint documents created by CAD software in B/W to improve
visualization of colored line image/text.
Vector To BlackYe s / N oPrint lines in BW to improve visualization.
Input Resolution
Yes / N oSpecify duplex printing function with giving priority to driver.
(Compatibility)
Duplex Style
Pattern1/ Pattern2/ Pattern3Default: 1
(compatibility)
Print by number of copy
Yes / N oSpecify print by set function with giving priority to driver.
(compatibility)
Water
marks
WatermarkNone / TOP SECRET / CONFIDENTIAL /
DRAFT / ORIGINAL / COPY
Select watermark specified as default.
User SettingAdd / Update / DeleteAdd, register and delete watermark.
PositionCenter
Adjust the position of watermark vertically and horizontally.
X: ±50
Y: ±50
Size6 - 300Adjust the size of watermark.
Angle±90Adjust the angle of watermark.
Grayscale0 - 255Adjust the watermark density.
Edit FontYe sEdit font.
Thick LetterYe s / N o
Italic FaceYe s / N o
Character SetYe s
On First Page onlyYes / N oPut watermark only on the first page.
OptionROPMOn/Off
Paper Feed Option1-Tray/2-Tray/3-Tray/4-Tray
Auto ConfigurationYe s
Paper Tray (Tray Setting)Bypass Tray/Tray1/Tray2/Tray3/Tray4
Paper Size to SpecifyNo specification/ A3 / B4 / A4 / B5 / A5 /
A6 / B6 / Ledger / Legal / 8.5x13.4 /
Foolscap / Folio / Letter / Invoice /
Executive / 8K / 16K / COM-10 / DL / C5 /
Custom
Status WindowYe s
Version InformationYe s
*1: Custom paper size range: Width 100 - 297.0 mm (3.94 -11.69 inch) Length 148 -431.8mm (5.83 - 17.00 inch)
MX-M182 SPECIFICATIONS 3-5
b. Windows version of PCL/PS Driver (PCL: MX-NB12 is expanded)
Contrast0 - 100%0 - 100%
Text To B lackYes / N oYe s / No
Vector To BlackYes / N oYe s / No
Right bindingYe s / N oYes / N o
Water marksWatermarkNone / TOP SECRET / CONFIDENTIAL /
DRAFT / ORIGINAL / COPY
None / TOP SECRET / CONFIDENTIAL /
DRAFT / ORIGINAL / COPY
User SettingAdd / Update / DeleteAdd / Update / Delete
PositionCenter
X: ±50
Y : ±50
Center
X: ±50
Y : ±50
Size6 - 3006 - 300
Angle±90±90
Grayscale0 - 2550 - 255
Edit FontYe sYes
Thick LetterYe s / N oYe s / N o
Italic FaceYe s / N oYe s / N o
Character SetYe sYes
Print PatternTransparent 1 / Transparent 2 / Overlap /
Transparent / Overlap / Outline
Outline
Frame LineNone/rectangle/CircleNone/rectangle/Circle
On First Page onlyYes / N oYe s / No
Special Mode Page InterleaveYesN/A
Paper
Insertion
Setting
Different 1st (Cover) and
Last Page
1st Page: On/Off
(Last Page Not Support)
1st Page : On/Off
(Last Page Not Support)
Duplex PrintingYe s / N oYe s / N o
Paper TrayBypass (Auto)
COM-10 / DL / C5 / Custom)
Print PolicyYe sYes
FontN/AYe s
Version InformationYe sYes
*1: Custom paper size range: Width 100 - 297.0 mm (3.94 -11.69 inch) Length 148 -431.8mm (5.83 - 17.00 inch)
MX-M182 SPECIFICATIONS 3-7
C. Windows version/Mac version of PPD Driver
FunctionWinPPDMac PPD
CopiesYe sYe s
Collate/UncollateYe sYe s
N-UPYe sYe s
N-up OrderNoYe s
N-up BorderNoYe s
DuplexYe sYe s
RetentionNoNo
Document FillingNoNo
User AuthenticationNoNo
User NumberNoYe s
Job ID (User Name/
Job Name)
Color ModeNoNo
Print ModeNoNo
Image TypeNoNo
Neutral GrayNoNo
Pure Black PrintNoNo
Black Over PrintNoNo
Toner SaveNoNo
Color AdjustmentNoNo
Source ProfileNoNo
Rendering IntentNoNo
Output ProfileNoNo
ScreeningNoNo
Simulation ProfileNoNo
Paper SizeA3 / B4 / A4 / B5 / A5 /
Executive / COM-10 /
Output TrayUpper Tray Center Tray Upper Tray Center Tray
*1: Custom paper size range: Width 100 - 297.0 mm (3.94 -11.69 inch)
Length 148 -431.8mm (5.83 - 17.00 inch)
NoYe s
B6 / A6 / 11x17 /
8.5x14 / 8.5 x 13.4/
8.5x13 / 8.5x11 /
5.5x8.5 / Folio /
DL / C5/ 8K / 16K/
Custom*1
A3 / B4 / A4 / B5 / A5 /
B6 / A6 / 11x17 /
8.5x14 / 8.5 x 13.4/
8.5x13 / 8.5x11 /
5.5x8.5 / Folio /
Executive / COM-10 /
DL / C5 / 8K / 16K /
A0 (Fit To Page) / A1 (Fit
To Page) / A2 (Fit To
Page) / Custom*1
3. Scanner mode
A. Scanner function
(1) Mode
ModeSub Mode
ScannerE-mailYe s
FTP Server
Network Folder (SMB)No
DesktopYe s
USB Memory
Twain Scan
(Including Button
Manager)
–Ye s
(MX-NB12 is expanded)
(MX-NB12 is expanded)
(2) Support Image (MX-NB12 is expanded)
ModeModeTy peSupport
Scanner
(MX-NB12 is
expanded)
File Format
(B/W)
File Format
(Gray Scale)
File Format
(Color)
TIFFYe s
PDFYe s
PDF/AN/A
Encrypted PDFN/A
XPSN/A
TIFFYe s
JPEGYe s
PDFYe s
PDF/AN/A
Encrypted PDFN/A
Compact PDF (ACRE installed) N/A
XPSN/A
TIFFYe s
JPEGYe s
PDFYe s
PDF/AN/A
Encrypted PDFN/A
Compact PDF (ACRE installed) N/A
XPSN/A
(3) Image Processing
ModeScanner (MX-NB12 is expanded)
Exposure AdjustmentAutoYe s
Manual5 levels
Original Type *1Te x tYe s
PhotoYe s
AutoYe s
Resolution (Different depending on
file format/ sending method)
*1: This setting can only be set at the B/W mode
75 x 75 dpi
100x100dpi
150x150dpi
200x200dpi
300x300dpi
400x400dpi
600x600dpi
(4) Push Scan (Button Manager)
Support OS Windows 2000 Professional/Windows XP Home Edition/
Hardware
Environment
Selectable
destination
File Format TIFF/PDF/BMP
Windows XP Professional/Windows Vista/Windows 7
(System) Shall meet the operating conditions of each OS
basically.
(HDD)8MB or more: 100MB or more is recommended
(Monitor) 800x600 dots or more
Shall be able to display 256 colors or more.
(Other)USB port (2.0)
Sharpdesk/ E-mail software/ Fax software/ OCR
software/ MS Word/ Any directory
MX-M182 SPECIFICATIONS 3-8
(5) Pull Scan (TWAIN)
USB TWAIN (Does not function in Network system)
Support OSWindows 2000 Professional/Windows XP Home Edition/ Windows XP Professional/ Windows Vista/Windows 7
InterfaceUSB
Hardware Environment(System) Shall meet the operating conditions of each OS basically.
Two-sided ScanYe s
Color ModeB/W(Mono2)/ B/W(Error Diffusion)/Gray Scale/Full Color
Resolution75dpi/ 100dpi/ 150dpi/ 200dpi/ 300dpi/ 400dpi/ 600dpi Or Custom: 50 - 9600dpi (simulated)
Scanning RangeA3/ A4/ A4-R/ A5/ A5-R/ B4/ B5/ B5-R/ Ledger/ Letter/ Letter-R/ Executive/ Executive-R/ Foolscap/ Invoice/
Preview FunctionYes
Zoom Preview FunctionYe s
Rotation ScanYes (90 / 180/ 270 degrees)
Quick ScanNo
Brightness/Contrast AdjustmentAuto/ Manual(-100 - +100)
Gamma AdjustmentYe s
Color MatchingNone/ Printer/ CRT/ LCD display/ ICM
Edge EmphasisNone/ Normal/ High/ Fuzzy
B/W ReverseYes
Selection of Light Source ColorYes (Red/ Green/ Blue/ White)
Threshold SettingAuto/ Manual (1-254)
Addition of Void AreaAvailable (Lead Edge/Trail Edge: 2.5mm Right/Left: 3.0mm)
Storing of Setting ContentsYe s
Keeping of Preview ImageYe s
Unit of Display for Scanning Range Pixel/ mm/ inch
Notes' Security FeatureNo
(HDD) 8MB or more: 100MB or more is recommended
(Monitor) 800x600dots or more
Shall be able to display 256 colors or more.
(Other) USB port
Support OSWindows 2000 Professional/Windows XP Home Edition/ Windows XP Professional/Windows Vista/Windows 7
Scan Resolution75x75, 100x100, 150x150, 200x200, 300x300, 400x400, 600x600dpi (main direction x sub direction)
InterfaceUSB 2.0, 10/100BASE-TX
Support Server/ProtocolTCP/IP, SMTP, LDAP, FTP
Output file formatB&W : PDF (w/o compression, G3, G4), TIFF (w/o compression, G3, G4)
2-sided original scanYe s
Optical Resolution400x600dpi
File creationFile per 1 to 6 page / 1 file for all pages
Sending method/LinkageFile server sending scan
Density1 - 5
Light SourceYes (Red/ Green/ Blue/ White)
Voi d AreaYe s
Control SystemEmbedded Web server
Recommended Web browserInternet Explorer6.0 or later
Support Mail systemMail server supporting SMTP, Mail server supporting POP3
AddressingRapid / Group / Indication by Direct Address Input / Selection from LDAP Server
Number of registration of
destination
UtilitySharpdesk
Color/Gray scale: JPEG, PDF(JPEG), TIFF(JPEG)
TIFF/PDF supports multi page.
Desktop sending scan
E-mail sending scan
USB memory scan
Max. 200 All destination including E-mail, File server, Desktop and Group. Multiple E-mail addresses can be
registered as a group and as 1 destination (max. 100). In this case, number of registration of destination may be
less than 200.
MX-M182 SPECIFICATIONS 3-9
b. Scanner Setting
KeyGroupingSelectable itemsRemark
Color ModeColor Mode*Color
Gray
Set the scan color
*Default is Color.
Monochrome
FormatFormat and Compression method TIFF
TIFF G3
Specify file format.
*Default is PDF
TIFF G4
*PDF
PDF G3
PDF G4
JPEG
Multi-file/Single fileSingle : 1 page / file
*Multi : All pages / file
Multi : 2 pages / file
Multi : 3 pages / file
Specify Single or Multi.
Single: 1 page / file
Multi: Plural pages / file
*Default: All pages / file
Multi : 4 pages / file
Multi : 5 pages / file
Multi : 6 pages / file
Vinyl bag
2DeveloperMX-235NVDeveloperx150K
3Drum KITAR-205DRDrum
Drum fixing plate
C. Europe
No.NameProduct nameContentLifeRemark
1Toner cartridge(Black)MX-235GTToner cartridge
Vinyl bag
2DeveloperMX-235GVDeveloperx150K
3Drum KITAR-205DMDrum
Drum fixing plate
x1x116K
Default is Toner save
mode. Life is 19K.
(200V series)
x1 x150K
x1x116KLife setting by A4 6% document
x1 x150K
x1x116KLife setting by A4 6% document
x1 x150K
Life setting by A4 6% document
D. Australia/New Zealand
No.NameProduct nameContentLifeRemarke
1Toner cartridge(Black)MX-235GTToner cartridge
Vinyl bag
2DeveloperMX-235GVDeveloperx150K
3Drum KITAR-205DMDrum
Drum fixing plate
x1x116KLife setting by A4 6% document
x1x150K
E. Middle East, Africa (except Iran) /Israel/Philippines/Others
No.NameProduct nameContentLifeRemark
1Toner cartridge(Black)MX-235FTToner cartridge
Vinyl bag
2Toner cartridge(Black)MX-236FTToner cartridge
Vinyl bag
3DeveloperMX-235FVDeveloperx150K
4Drum KITAR-205DRDrum
Drum fixing plate
x1x116KLife setting by A4 6% document
x1x18.4KLife setting by A4 6% document
x1
50K
x1
F. Ta iw an
No.NameProduct nameContentLifeRemark
1Toner cartridge(Black)MX-235FTToner cartridge
Vinyl bag
2Toner cartridge(Black)MX-236FTToner cartridge
Vinyl bag
3DeveloperMX-235FVDeveloperx150K
4Drum KITAR-205DRDrum
Drum fixing plate
x1x116KLife setting by A4 6% document
x1x18.4KLife setting by A4 6% document
x1x150K
MX-M182 CONSUMABLE PARTS 4-1
G. Asia(Except the above)/Thailand/Hong Kong
No.NameProduct nameContentLifeRemark
1Toner cartridge(Black)MX-235ATToner cartridge
Vinyl bag
2Toner cartridge(Black)MX-236ATToner cartridge
Vinyl bag
3DeveloperMX-235AVDeveloperx150K
4Drum KITAR-205DRDrum
Drum fixing plate
x1x116KLife setting by A4 6% document
x1x18.4KLife setting by A4 6% document
x1x150K
2. Environmental conditions
A. Transport conditions
(1) Transport conditions
Humidity (%)
B. Use conditions
Use environment
conditions
Humidity (%)
Temperature
(2) Storage conditions
Humidity (%)
Temperature
C. Life(packed conditions)
Photoconductor drum (36 months from the production month)
Developer, toner (24 months from the production month)
Temperature
MX-M182 CONSUMABLE PARTS 4-2
3. Production number identification
<Toner cartridge>
The label on the toner cartridge shows the date of production.
<Drum cartridge>
The lot number, printed on the front side flange, is composed of 10 digits,
each digit showing the following content:
12345678910
The lot number is of 10 digits. Each digit indicates the content as follows.
The number is printed on the flange on the front side.
place
Serial
number
Year/
Month/
Day
Ver.No.Production
1:Number
For this model, this digit is 2.
2:Alphabet
Indicates the model conformity code. G for this model.
3:Number
Indicates the end digit of the production year.
4:Number or X, Y, Z
Indicates the production month.
X stands for October, Y November, and Z December.
5/6:Number
Indicates the day of the production date.
7:Number
Indicates the day of the month of packing.
X stands for October, Y November, and Z December.
8/9:Number
Indicates the day of the packing date.
10:Alphabet
Indicates the production factory.
MX-M182 CONSUMABLE PARTS 4-3
[5] EXTERNAL VIEWS AND INTERNAL STRUCTURES
1. Appearance
3
8
9
7
4
5
13
5
1
6
10
14
15
2
12
11
1718
16
1 USB 2.0 portConnect to your computer to this port to use the printer and scanner functions.
2 Charger cleanerUse to clean the transfer charger.
3 Glass cleanerUse to clean the original scanning glass.
4 Document glassPlace an original that you wish to scan face down here.
5 HandlesUse to move the machine.
6 Power switchPress to turn the machine power on and off.
7 Centre trayCopies and printed pages are output to this tray.
8 Top tray (when the job separator tray kit is installed) Received faxes (when the fax option is installed) and print jobs are delivered to this tray.
9 Operation panelContains operation keys and indicator lights.
10 Front coverOpen to remove paper misfeeds or replace the toner cartridge.
11 Tray 1Tray 1 can hold approximately 250 sheets of copy paper (80 g/m2 (20 lbs.)).
12 Tray 2Tray 2 can hold approximately 250 sheets of copy paper (80 g/m2 (20 lbs.)).
13 Document cover (when installed)Open to make a copy from the document glass.
14 Side coverOpen to remove misfeed paper.
15 Side cover handlePull to open the side cover.
16 Bypass tray guidesAdjust to the width of the paper when using the bypass tray.
17 Bypass traySpecial paper (heavy paper or transparency film) can be fed from the bypass tray.
18 Bypass tray extensionPull out when feeding large paper such as A3 and B4 (11" x 17" and 8-1/2" x 14").
MX-M182 EXTERNAL VIEWS AND INTERNAL STRUCTURES 5-1
2. Internal
19
20
21 22
23
24
2526
27
2829
19 Toner cartridge lock release leverTo replace the toner cartridge, pull out the toner cartridge while pushing on this lever.
20 Toner cartridgeContains toner.
21 Document feeder tray (when the SPF/
RSPF is installed)
22 Original guides (when the SPF/RSPF is
installed)
23 Feeding roller cover (when the SPF/
RSPF is installed)
24 Right side cover (when the SPF/RSPF is
installed)
25 Fusing unit release leversTo remove the paper misfeed in the fusing unit, push down on these levers and remove the paper.
26 Roller rotating knobRotate to remove misfeed paper.
27 Exit area (when the SPF/RSPF is
installed)
28 Photoconductive drumImages are formed on the photoconductive drum.
29 Fusing unit paper guideOpen to remove misfeed paper.
Warning: The fusing unit is hot. Do not touch the fusing unit when removing misfeed paper. Doing so may cause a burn or injury.
Do not touch the photoconductive drum (green portion) when removing the misfeed paper. Doing so may damage the drum and cause
smudges on copies.
Note: The model name is on the front cover of the machine.
Place the original(s) that you wish to scan face up here. Up to 40 sheets can be placed.
Adjust to the size of the originals.
Open to remove misfeed originals.
Open to remove misfeed originals.
Originals exit the machine here after copying/scanning when the SPF/RSPF is used.
MX-M182 EXTERNAL VIEWS AND INTERNAL STRUCTURES 5-2
3. Operation Section
12345
0102030405
0607080910
1112131415
1617181920
2122232425
SPEAKER
SHIFT
REDIAL/PAUSE
SPEED
SYMBOL
COMM. SETTING
SPACE/–
COPY
PRINT
SCAN
FAX
ON LINE
DATA
LINE
DATA
FAX STATUS
SPECIAL
FUNCTION
EXPOSURE
COPY
COLOUR MODE
SCAN
PROGRAM
FAX
131415
1 Keys for fax function (when the fax
These are used in fax mode.
678910 1112
INTERRUPT
COPY RATIO
PAPER SELECT
ADDRESS
RESOLUTION
ADDRESS
RESOLUTION
AUTO IMAGE
FORMAT
BROADCAST
OUTPUT
ORIGINAL SIZE
ORIGINAL SIZE
2-SIDED COPY
DUPLEX SCAN
DUPLEX SCAN
BACK
ABCDEF
ACC. #-C
JKLGHIMNO
TUVPQRSWXYZ
@.-
READ-END
_
OK
16 17 18 19 2021 222324 25 26
option is installed)
2 [COPY] key / indicatorPress to select copy mode. If pressed when "Ready to copy." appears or during warm-up, the total
number of sheets used appears while the key is pressed.
3 [PRINT] key / indicatorPress to select print mode.
• ONLINE indicatorPrint jobs can be received when this indicator is lit.
• DATA indicatorThis lights steadily when there is a print job in memory that has not been printed, and blinks
during printing.
4 [SCAN] key / indicatorPress to select scan mode. To use the machine as a network scanner, see the "Operation Guide
(NETWORK EXPANSION KIT)" that accompanies the machine.
5 [FAX STATUS] key (when the fax option
This key is used in fax mode.
is installed)
6 DisplayShows various messages.
7 [BACK] keyPress to return the display to the previous screen.
8 Copy number displayThe selected number of copies appears. During copying, this shows the remaining number of
copies.
9 [OK] keyPress to enter the selected setting.
10 Numeric keysUse to select the number of copies.
11 [C] keyPress to clear the set number of copies or stop a copy run.
12 [INTERRUPT] key () / INTERRUPT
Interrupts a copy run to allow an interrupt copy job to be performed.
indicator
13 [FAX] key / indicator (when the fax option
is installed)
This key is used in fax mode.
LINE indicator, DATA indicator
14 [SPECIAL FUNCTION] keyPress to select special functions.
15 [EXPOSURE] keyUse to select the exposure mode. "AUTO", "TEXT", or "PHOTO" can be selected.
16 [PAPER SELECT] keyUse to manually select a paper tray.
17 [COPY RATIO] keyPress to select a reduction or enlargement copy ratio.
18 [AUTO IMAGE] keyPress to have the copy ratio selected automatically.
19 [OUTPUT] keyUse to select the sort function.
20 [2-SIDED COPY] key
Select the two-sided copying mode.
(MX-M182D/MX-M202D/MX-M232D)
21 Arrow keysPress to move the highlighting (which indicates that an item is selected) in the display.
22 [ACC.#-C] key ()Press the end the use of an account and return the display to the account number entry screen.
23 [0] keyPress during a continuous copy run to display the number of copies completed.
24 [READ-END] key ()When copying in sort mode from the document glass, press this key when you have finished scanning
the original pages and are ready to start copying.
25 [CA] keyClears all selected settings and returns the machine to the default settings.
26 [START] key () / indicatorCopying is possible when this indicator is on. Press the key to start copying. This indicator blinks when
auto power shut-off mode has activated. Press the key to return to normal operation.
MX-M182 EXTERNAL VIEWS AND INTERNAL STRUCTURES 5-3
4. Motor, solenoid, clutch
11
113
12
2
3
4
6
5
7
8
910
No.NameCodeFunction operation
1 Mirror motorMRMDrives the optical mirror base (scanner unit).
2 Toner motorTMToner supply
3 Duplex motorDPXSwitchback operation and paper exit motor in duplex. (MX-M182D/M202D/M232D)
4 Main motorMMDrives the machine.
5 1st tray paper feed clutchCPSCL1Drives the pick up roller
6 PS clutchRRCDrives the resist roller
7 Bypass tray paper transport clutchMPTCDrives the bypass tray paper transport roller.
8 Bypass tray paper feed solenoidMPFSBypass tray paper feed solenoid
9 2nd tray transport clutchFSCL1Drives the 2nd tray transport roller. (MX-M202D/M232D)
10 2nd tray paper feed clutchPSCL2Drives the 2nd tray paper feed roller. (MX-M202D/M232D)
11 Exhaust fan motorPSFMCools the inside of the machine.
12 Cooling fan motorVFMCools the inside of the machine.
13 Shifter motorSFTMDrives the shifter motor.
MX-M182 EXTERNAL VIEWS AND INTERNAL STRUCTURES 5-4
5. Sensor, switch
19
16
(AB)
(INCH)
1
(AB)
(INCH)
17
20
3
18
4
15
5
6
2
7
14
13
8
9
12
No.NameCodeFunction operation
1 Mirror home position sensorMHPSDetects the mirror (scanner unit) home position.
2 Side door switchDSWRSide door open detection
3 Paper exit sensor (paper exit side)POD1Detects paper exit.
4 Paper exit sensor (DUP side)PDPXPaper transport detection
5 ThermistorRTHFusing section temperature detection
6 ThermostatRDTCTFusing section abnormally high temperature detection
7 Toner density sensorTCSDetects the toner density in the developing unit.
8 2nd tray detection switchCSD22nd tray detection
9 Bypass tray sensorMPEDBypass tray transport detection
10 2nd tray door open/close sensorDRS22nd tray door open/close detection (MX-M202D/M232D)
11 2nd tray door paper pass sensorPPD22nd tray paper entry detection (MX-M202D/M232D)
12 2nd tray paper empty sensorCSS22nd tray paper empty detection (MX-M202D/M232D)
13 Paper in sensorPINPaper transport detection
14 Tray emptyCSS1Tray paper entry detection
15 Front cover SWDSWFFront cover open detection
16 Power switchMAIN SWTurns ON/OFF the main power source.
17 OC sensorOCSWOriginal cover and SPF open/close detection
18 Shifter home position sensorSFTHPShifter home position detection
19 Original size sensor(Main Scaning)DSIN0Original size detection
20 Original size sensor(Sub Scaning)DSIN1Original size detection
10
11
MX-M182 EXTERNAL VIEWS AND INTERNAL STRUCTURES 5-5
6. PWB unit
2
1
8
3
7
9
4
6
5
No.NameFunction operation
1 Copy lamp Inverter PWBCopy lamp control
2 CCD sensor PWBImage scanning
3 Main control PWBMain control PWB
4 2nd tray PWB2nd tray control
5 High voltage PWBHigh voltage control
6 Power PWBAC power input/DC power control
7 Operation main PWBOperation panel input/Display, operation panel section control
8 USB I/F PWBConnect a USB device
9 LCD OPE PWBDisplay and operation panel control
MX-M182 EXTERNAL VIEWS AND INTERNAL STRUCTURES 5-6
7. Cross sectional view
17
2
4
563
18
8
9
10
11
12
23
22
13
14
15
1617192021
No.NameFunction/Operation
1Copy lampImage radiation lamp
2Copy lamp unitOperates in synchronization with No. 2/3 mirror unit to radiate documents
sequentially.
3LSU unitConverts image signals into laser beams to write on the drum.
4Lens unitReads images with the lens and the CCD.
5MC holder unitSupplies negative charges evenly on the drum.
6Paper exit rollerUsed to discharge paper.
7Transport rollerUsed to transport paper.
8Upper heat rollerFuses toner on paper (with the teflon roller).
9Lower heat rollerFuses toner on paper (with the silicon rubber roller).
10Waste toner transport rollerTransports waste toner to the waste toner box.
11Drum unitForms images.
12Transfer charger unitTransfer images (on the drum) onto paper.
13DUP follower rollerTransports paper for duplex.
14Duplex transport rollerTransports paper for duplex .
15Resist rollerTakes synchronization between the paper lead edge and the image lead edge.
16Bypass trayBypass tray
17Bypass tray paper pick up rollerPicks up paper in bypass tray.
18No. 2/3 mirror unitReflects the images from the copy lamp unit to the lens unit.
19Bypass tray transport rollerTransports paper from the bypass tray.
202nd tray paper transport rollerTransports paper from the 2nd tray. (MX-M202D/M232D)
212nd tray paper pick up rollerPicks up paper from the 2nd tray. (MX-M202D/M232D)
221st tray paper feed rollerPicks up paper from the 1st tray.
23MG rollerPuts toner on the OPC drum.
MX-M182 EXTERNAL VIEWS AND INTERNAL STRUCTURES 5-7
2) Insert a thickness gauge of 1.5mm to the three positions at 20mm
and 150mm from the both ends of the developing doctor as shown.
(1)Developing doctor gap adjustmentDeveloping doctor gap adjustment
(2)MG roller main pole position adjustmentMG roller main pole position adjustment
(3)Developing bias voltage check
(4)Main charger voltage check
(1)Image position adjustmentSIM-50
(2)Main scanning direction (FR direction) distortion balance
adjustment
(3)Main scanning direction (FR direction) distortion adjustmentRail height adjustment
(4)Sub scanning direction (scanning direction) distortion
adjustment
(5)Main scanning direction (FR direction) magnification ratio
adjustment
(6)Sub scanning direction (scanning direction) magnification ratio
adjustment
(7)Off center adjustmentOC mode (SIM 50-12)
(1)Copy modeSIM 46-2
No. 2/3 mirror base unit installing position adjustment
Copy lamp unit installing position adjustment
Winding pulley position adjustment
SIM 48-1
OC mode in copying (SIM 48-1)
SPF mode in copying (SIM 48-5)
SPF mode (SIM 50-12)
(2) MG roller main pole position adjustment
1) Remove the DV front cover, and put the developing tank on a flat
surface.
2) Tie a string to a needle or a pin.
3) Hold the string and bring the needle close to the MG roller
horizontally. (Do not use paper clip, which is too heavy to make a
correct adjustment.) (Put the developing unit horizontally for this
adjustment.)
4) Do not bring the needle into contact with the MG roller, but bring it to
a position 2 or 3mm apart from the MG roller. Mark the point on the
MG roller which is on the extension line from the needle tip.
5) Measure the distance from the marking position to the top of the
doctor plate of the developing unit to insure that it is 18mm.
If the distance is not within the specified range, loosen the fixing
screw A of the main pole adjustment plate, and move the adjustment
plate in the arrow direction to adjust.
3) Push the developing doctor in the arrow direction, and tighten the fixing
screws of the developing doctor in the sequence of 132
4) Check the clearance of the developing doctor. If it is within the
specified range, then fix the doctor fixing screw with screw lock.
*When inserting a thickness gauge, be careful not to scratch the
developing doctor and the MG roller.
<Adjustment specification>
33.
MX-M182 ADJUSTMENT 6-1
(3) Developing bias voltage check
(Mode selection window 1)
Sim50-1 LEAD EDGE
1:TRAY1
2:TRAY2
3:MFT
1/2 [ 1- 99]
50
50
50
50
(Mode selection window 2)
Sim50-1 LEAD EDGE
4:DEN-A
5:RRC-A
6:DEN-B
2/2 [ 1- 99]
50
1
50
50
Ready to copy.
S
100%
A4
(Copy start window)
Copies in progress.
S
100%
A4
(Copy execution window)
Note:Use a digital multi-meter with an internal resistance of 10M or
more.
1) Set the digital multi-meter range above 500 Vdc.
2) Put the test rod of the digital multi-meter on the developing bias
voltage output check pin.
3) Turn on the power, execute SIM25-1.
B. Mechanism section
(1) Image position adjustment
a. OC image lead edge position adjustment (SIM 50-1)
Note:In advance to this adjustment, the sub scanning magnification ratio
adjustment must be performed.
1) Set a scale on the OC table as shown below.
2) Make a copy.
3) Check the copy output. If necessary, perform the following
adjustment procedures.
4) Execute SIM 50-01.
Select a desired mode with the arrow keys, enter the adjustment
value with 10-key, and press [OK] key.
When [START] key is pressed, a sheet is printed.
<Specification>
Mode Specification
Developing bias voltage DC - 400±10V
(4) Grid bias voltage check
Note:Use a digital multi-meter with an internal resistance of 10M or
more.
1) Set the digital multi-meter range above 600 Vdc.
2) Put the test rod of the digital multi-meter on the grid bias voltage
output check pin.
3) Turn on the power.
(The voltage is outputted in the grid bias High output mode during
warming up, and in the grid bias Low output mode when warming up
is completed.)
<Specification>
Mode Specification
Grid bias LOW DC - 380±8V
Grid bias HIGH DC - 525±10V
<Adjustment specification>
Adjustment
mode
OC image lead
edge position
Main cassette
SIM Display
text array
SIM
RRC-AR/0.1Lead edge
50-1
TRAY1H/0.1
Set
value
Spec
value
void:
1 - 4mm
Set
range
1 - 99
print start
position
2nd cassette
print start
TRAY2
Image loss:
3mm or
less
position
Multi bypass
MFT
tray print start
position
Lead edge voidDEN-AB/0.05
5) Set the OC lead edge position set value (RRC-A) to [1]
The OC image scanning start position is shifted inside the document
edge.
6) Set the main cassette lead edge void adjustment value (DEN-A)* to [1]
The lead edge void becomes the minimum.
MX-M182 ADJUSTMENT 6-2
7) Set the main cassette print start position value (TRAY1) to [1] and
5
10
2.5mm
2.5mm
(Mode selection window)
Ready to copy.
S
100%
A4
(Copy start window)
Copies in progress.
S
100%
A4
(Copy execution window)
Sim50-6 SPF EDGE
1:SIDE1
2:SIDE2
3:END EDGE
[ 1- 99]
50
50
50
50
make a copy.
The print start position is shifted inside the document edge.
5mm
5
10
*The dimension varies depending on the model.
4mm
8) Measure the image loss R of the copied image. Enter the set value of
the image scanning lead edge position (RRC-A) again.
• 1 step of the set value corresponds to about 0.1mm shift.
• Calculate the set value from the formula below.
R/0.1(mm) = Image loss set value
<R: Image loss measurement value (mm)>
10) Set the lead edge void adjustment value (DEN-A)* again.
• 1 step of the set value corresponds to about 0.1mm shift.
• Calculate the set value from the formula below.
B/0.05 (mm) = Lead edge void adjustment value
<B: Lead edge void (mm)>
Example:When setting the lead edge void to 2.5mm
:2.5 /0.05 = about 50
Note:If the set value is not obtained from the above formula, perform the
fine adjustment.
5mm
5
10
* The scanning edge is set.
(A line may be printed by scanning the document edge.)
0mm
Example:4/0.1 = 40 = about 40
Note:If the set value is not obtained from the above formula, perform the
fine adjustment.
9) Measure the distance H between the paper lead edge and the image
print start position. Set the image print start position set value
(TRAY1) again.
• 1 step of the set value corresponds to about 0.1mm shift.
• Calculate the set value from the formula below.
H/0.1(mm) = Image print start position set value
<H: Print start position measurement value (mm)>
0mm
5
10
0mm
b. SPF image lead edge position adjustment (SIM50-6)
1) Set a scale on the OC table as shown below.
Note:Since the printed copy is used as a test chart, put the scale in
parallel with the edge lines.
2) Make a copy, Then use the copy output as an original to make an
SPF copy again.
3) Check the copy output. If necessary, perform the following
adjustment procedures.
4) Execute SIM 50-6.
5) Set the SPF lead edge position set value (SIDE1) so that the same
image is obtained as that obtained in the previous OC image lead
edge position adjustment.
Example:5/0.1 = 50 = about 50
Note:If the set value is not obtained from the above formula, perform the
fine adjustment.
*Fit the print edge with the paper edge, and perform the
lead edge adjustment.
MX-M182 ADJUSTMENT 6-3
<Adjustment specification>
Scale image
Paper rear edge
Void amount (Standard value: 4mm or less)
Sim50-10
PRT. CENTER
1:TRAY1
2:TRAY2
3:TRAY3
1/2 [ 1- 99]
50
50
50
50
Sim50-10
PRT. CENTER
4:TRAY4
5:BYPASS
6:DUPLEX
2/2 [ 1- 99]
50
50
50
50
Sim26-43 SIDE VOID
1:SIDE VOID(L)
2:SIDE VOID(R)
[ 0- 10]
3
3
3
Adjustment mode SIM Display
text
array
SPF image lead
edge position
SIM
50-6
SIDE1 1 step:
(1st print surface)
Set value Spec value Set
range
0.1mm
shift
Lead edge
void:
1 - 4mm
1 - 99
Image loss:
3mm or
less
d. Paper off center adjustment (SIM50-10)
1) Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and
the test chart. If necessary, perform the following adjustment
procedure.
3) Execute SIM 50-10. After completion of warm-up, shading is
performed and the currently set off center adjustment value of each
paper feed port is displayed.
c. Rear edge void adjustment (SIM50-1, SIM50-19)
1) Set a scale as shown in the figure below.
A4(8.5" x 11")
Paper rear edge
2) Set the document size to A4 (8.5" x 11"), and make a copy at 100%.
3) If necessary, perform the following adjustment procedure.
4) Execute SIM50-01 and select "DEN-B" with the arrow keys.
The currently set adjustment value is displayed.
5) Enter the set value and press the start key. The correction value is
stored and a copy is made.
<Adjustment specification>
Mode SIM Display
Rear edge void SIM
50-1
text array
DEN-B1 step:
Set value Specifi-
cation
4mm or
0.1mm shift
less
Set
range
1 - 99
4) Enter the set value and press the start key. The correction value is
stored and a copy is made.
<Adjustment specification>
Adjustment
mod
Tr ay 1 SIM
Tr ay 2TRAY2
Tr ay 3TRAY3
Tr ay 4TRAY4
Manual paper
feed tray
Duplex
SIMDisplay
text array
TRAY1Add 1:
50-10
BYPASS
DUPLEX
Set value Specifi-
cation
Single:
0.1mm shift
to R side.
Center
±2.0mm
Reduce 1:
0.1mm shift
to L side.
Set
range
1 - 99
(Second print
surface)
e. Side edge void area adjustment (SIM26-43)
Note:Before performing this adjustment, be sure to check that the paper
off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and
the test chart. If necessary, perform the following adjustment
procedure.
3) Execute SIM 26-43 and set the density mode to SIDE VOID (L),
SIDE VOID (R).
The currently set adjustment value is displayed.
4) Enter the set value and press the start key. The correction value is
stored.
<Adjustment specification>
Adjustment
mode
Side void (left)26-43SIDE
Side void (right)SIDE
MX-M182 ADJUSTMENT 6-4
SIMDisplay
text array
VOID (L)
VOID (R)
Set value Specifi-
cation
1 step:
0.5 - 4mm 1 - 99
0.5mm shift
Set
range
(2) Main scanning direction (FR direction) distortion
(1)
(1)
(2)
(4)
(3)
(3)
balance adjustment
1) Remove the OC glass and the right cabinet.
2) Loosen the copy lamp unit wire fixing screw.
4) Loosen the set screw of the scanner drive pulley which is not in
contact with No. 2/3 mirror base unit positioning plate.
5) Without moving the scanner drive pulley shaft, manually turn the
scanner drive pulley until the positioning plate is brought into contact
with No. 2/3 mirror base unit, then fix the scanner drive pulley.
Wire fixing screw
3) Manually turn the mirror base drive pulley and bring No. 2/3 mirror
base unit into contact with the positioning plate. At that time, if the
front frame side and the rear frame side of No. 2/3 mirror base unit
are brought into contact with the positioning plate at the same time,
the mirror base unit parallelism is proper. If one of them is in contact
with the positioning plate, perform the adjustment of 4).
6) Put No. 2/3 mirror base unit on the positioning plate again, push the
projections on the front frame side and the rear frame side of the
copy lamp unit to the corner frame, and tighten the wire fixing screw.
MX-M182 ADJUSTMENT 6-5
(3) Main scanning direction (FR direction) distortion
r
A
B
Rear side
Front side
When La < Lb
Turn the mirror base drive pulley on the front frame side in the
arrow direction A.
(Do not move the mirror base drive pulley shaft.)
When La > Lb
Turn the mirror base drive pulley on the rear frame side in the
arrow direction A.
(Do not move the mirror base drive pulley shaft.)
adjustment
This adjustment must be performed in the following cases:
• When the mirror base drive wire is replaced.
• When the lamp unit, or No. 2/3 mirror holder is replaced.
• When a copy as shown is made.
4) Loosen the mirror base drive pulley fixing screw on the front frame
side or on the rear frame side.
La
Lb
Paper exit
direction
Original
Copy
1) Set A3 (11" x 17") white paper on the original table as shown below.
Allow a little space.
Glass holding plate
Fit the paper edge and
the glass holding plate edge.
A3 (11" x 17") white pape
2) Open the original cover and make a normal (100%) copy.
3) Measure the width of the black background at the lead edge and at
the rear edge.
5) Tighten the mirror base drive pulley fixing screw.
<Adjustment specification>
La = Lb
6) Execute the main scanning direction (FR) distortion balance
adjustment previously described in 2) again.
(4) Sub scanning direction (scanning direction) distortion
adjustment
When there is no skew copy in the mirror base scanning direction and
there is no horizontal error (right angle to the scanning direction), the
adjustment can be made by adjusting the No. 2/3 mirror base unit rail
height.
Before performing this adjustment, be sure to perform the horizontal
image distortion adjustment in the laser scanner section.
This adjustment must be performed in the following cases:
•When the mirror base wire is replaced.
•When the copy lamp unit or No. 2/3 mirror unit is replaced.
•When the mirror unit rail is replaced or moved.
•When a following copy is made.
Paper exit direction
La: Lead edge black background width
Lb: Rear edge black background width
If the width (La) of the black background at the lead edge is equal that
(Lb) at the rear edge, there is no need to execute the following
procedures of 4) - 7).
Original
MX-M182 ADJUSTMENT 6-6
Copy ACopy B
1) Making of a test sheet
When La > Lb
Shift the mirror base B rail upward by the half of the
difference of La - Lb.
When La < Lb
Shift the mirror base B rail downward by the half of the
difference of Lb - La.
Example: When La = 12mm and Lb = 9mm, shift the mirror
base B rail upward by 1.5mm.
When Lc > Ld
Shift the mirror base B rail downward by the half of the
difference of Lc - Ld.
When Lc < Ld
Shift the mirror base B rail downward by the half of the
difference of Ld - Lc.
When moving the mirror base rail, hold the mirror base rail
with your hand.
Sim48-1 COPY MAG.
1:F-R
2:SCAN
[ 1- 99]
50
50
50
Make test sheet by drawing parallel lines at 10mm from the both
ends of A3 (11" x 17") white paper as shown below. (These lines
must be correctly parallel to each other.)
Parallel line
Parallel line
10mm
10mm
10mm
10mm
White paper
2) Make a normal (100%) copy of the test sheet on A3 (11" x 17")
paper. (Fit the paper edge with the glass holding plate edge.)
3) Measure the distances (La, Lb, Lc, Ld) at the four corners as shown
below.
Paper exit
direction
La
LbLd
Lc
When La = Lb and Lc = Ld, no need to perform the procedures 4) and 5).
4) Move the mirror base F rail position up and down (in the arrow
direction) to adjust.
<Adjustment specification>
La = Lb, Lc = Ld
5) After completion of adjustment, manually turn the mirror base drive
pulley, scan the mirror base A and mirror base B fully, and check that
the mirror bases are not in contact with each other.
*If the mirror base rail is adjusted to extreme, the mirror base may
contact the frame or original glass. Be careful to avoid this.
(5) Main scanning direction (FR direction) magnification
ratio adjustment (SIM 48-1)
Note:Before performing this adjustment, be sure to check that the CCD
unit is properly installed.
1) Put a scale on the original table as shown below.
Note:Do not adjust the rail on the rear side.
If the rail on the rear side is adjusted, an error may occur.
Only the rail on the front side can be adjusted.
2) Execute SIM 48-1.
3) After completion of warming up, shading is operated and the current
correction value of the main scanning direction magnification ratio is
displayed on the screen.
4) Enter the set values of the items of F and R, and press [START] key.
The correction values are saved and a copy is made.
MX-M182 ADJUSTMENT 6-7
<Adjustment specification>
Sim48-5 (R)SPF ZOOM
1:RSPF(SIDE1)
2:RSPF(SIDE2)
[ 1- 99]
50
50
50
Note: A judgment must be made with 200mm width, and must not be
made with 100mm width.
Adjustment modeSIMDisplay
text array
Main scanning
direction magnifi
48-1F-R+1
-
cation ratio
Set
value
+0.1%
-1
Specifications
Normal ±
1.0%
Set
range
1 - 99
0.1%
1) Put a scale on the original table as shown below, and make a normal
(100%) copy to make a test chart.
(6) Sub scanning direction (scanning direction)
magnification ratio adjustment (SIM 48-1, SIM 48-5)
a. OC mode in copying (SIM48-1)
Note:Before performing this adjustment, be sure to check that the CCD
unit is properly installed.
1) Put a scale on the original table as shown below, and make a normal
(100%) copy.
2) Compare the scale image and the actual image. If necessary,
perform the following adjustment procedures.
3) Execute SIM 48-1.
4) After completion of warming up, shading is operated and the current
correction value of the sub scanning direction magnification ratio is
displayed on the screen.
Sim48-1 COPY MAG.
1:F-R
2:SCAN
[ 1- 99]
5) Select [2.SCAN] mode with the cross cursor.
Sim48-1 COPY MAG.
1:F-R
2:SCAN
[ 1- 99]
6) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
Adjustment modeSIMDisplay
text array
Sub scanning
48-1SCAN +1
direction
magnification ratio
OC mode
b. RSPF sub scanning direction magnification ratio (SIM48-5)
Note:
•Before performing this adjustment, be sure to check that the CCD unit is
properly installed.
•Before performing this adjustment, the OC mode adjustment in copying
must be completed.
50
50
50
50
50
50
Set
value
+0.1%
-1
0.1%
Specifications
Normal ±
1.0%
Set
range
1 - 99
Note:Since the printed copy is used as a test chart, put the scale in
parallel with the edge lines.
2) Set the test chart on the SPF and make a normal (100%) copy.
3) Compare the scale image and the actual image. If necessary,
perform the following adjustment procedures.
4) Execute SIM 48-5.
5) After warm-up, shading is performed.
6) Check to confirm that the RSPF (SIDE1) mode is selected with the
cross cursor.
7) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
Adjustment modeSIMDisplay
text array
Sub scanning
direction
48-5RSPF
(SIDE1)
magnification
ratio
Set
value
+1
+0.1%
-1
0.1%
Specifications
Normal ±
1.0%
Set
range
1 - 99
(Front surface)
Sub scanning
direction
RSPF
(SIDE2)
magnification
ratio
(Back surface)
* "RSPF (SIDE2)" is displayed only when the RSPF is installed.
(7) Off center adjustment (SIM 50-12)
a. OC mode (SIM50-12)
1) Make a test chart as shown below and set it so that its center line is
fit with the original guide center mark.
* To make a test chart, draw a line on A3 or 11" x 17" paper at the center
in the paper transport direction.
Original guide
Center
Copy paper
(A3 or 17" x 11")
2) Make a normal copy from the manual paper feed tray, and compare
the copy and the test chart.
If necessary, perform the following adjustment procedures.
3) Execute SIM 50-12.
MX-M182 ADJUSTMENT 6-8
4) After completion of warming up, shading is performed and the
current off-center adjustment value is displayed on the LCD.
Sim50-12
ORG. CENTER
1:OC
2:SPF(SIDE1)
3:SPF(SIDE2)
[ 1- 99]
50
50
50
50
5) Enter the set value and press the start key.
The set value is stored and a copy is made.
C. Image density adjustment
(1) Copy mode (SIM 46-2)
1) Set a test chart (UKOG-0162FCZZ) on the OC table as shown
below.
<Adjustment specification>
Adjustment
mode
Document off-
SIMDisplay
text array
50-12OC+1
center (OC
mode)
Set valueSpecifi-
cations
Center ±
Shifted to R
2.0%
side by
+0.mm.
-1
Shifted to L
side by
0.1mm.
Set
range
1 - 99
UKOG-0162FCZZ
2) Put several sheets of A3 or 11" x 17" white paper on the test chart.
3) Execute SIM 46-2.
4) After completion of warming up, shading is performed, and the
current density level is displayed on the LCD.
Sim46-1 EXP LEVEL
1:AE
2:TEXT
3:PHOTO 1
1/2 [ 1- 99]
50
50
50
50
Sim46-1 EXP LEVEL
4:PHOTO 2
5:TEXT(TS)
6:AE(TS)
2/2 [ 1- 99]
50
50
50
50
Use the cross cursor to select a mode.
5) Change the set value with the 10-key to adjust the copy image
density.
6) Make a copy and check that the specification below is satisfied.
<Adjustment specification>
Density
Automatic
Te xtTEXT3"3" is slightly
Photo
(Error
diffu
Display
mode
text
array
Expo-
sure
level
AE-"2" is slightly
PHOTO13"2" is slightly
-
Sharp Gray
Chart output
copied.
copied.
copied.
Set valueSet
The greater the set
value is, the darker
the density is.
The smaller the set
value is, the lighter
the density is.
range
1 - 99
sion)
Photo
(Dither)
Toner
save
PHOTO23"2" is slightly
copied.
TEXT
(TS)
3"3" is slightly
copied.
(Text)
Toner
save
(Auto
AE(TS)-"2" is slightly
copied.
-
matic)
MX-M182 ADJUSTMENT 6-9
[7] SIMULATIONS
1. Entering the simulation mode
Perform the following procedure to enter the simulation mode.
[#] key [ ] key [C] key [ ] key
Main code [START] key Sub code [START] key
2. Canceling the simulation mode
When the [CA] key is pressed, the simulation mode is cancelled.
When the interruption key is pressed, the process is interrupted and the
screen returns to the sub code entering display.
*After canceling the simulation mode, be sure to turn OFF/ON the
power and check the operation.
Note: If the machine is terminated by a jam error or paper empty during
copying in the adjustment by the simulation, recopying is required.
Note: The values in the simulation columns are not default values but
sample values.
3. List of simulations
Main
Sub
code
code
0101Mirror scanning operation
02Mirror home position sensor (MHPS) status display
0201Single paper feeder (SPF)/Reversing single pass
0302Shifter/job separator sensor status display
0501Operation panel display check
0601Paper feed/transport solenoid operation check
0701Warm-up display and aging with jam detection
0801Developing bias output
0901Duplex motor forward rotation check *6
10-Toner motor operation
14-Trouble cancel (except for U2)
16-U2 trouble cancel
2001Maintenance counter clear
2101Maintenance cycle setting
04Detection level adjustment when the document size is
settled(15degrees - 20degrees)
Contents
MX-M182 SIMULATIONS 7-1
Main
Sub
code
code
4301Fusing temperature setting 1
02Fusing temperature setting 2
03Fusing temperature setting 3
04Fusing temperature setting 4
12Standby mode fusing fan rotation setting
13Paper interval control allow/inhibit setting
4401Enable/Disable setting of toner density control
correction
16Toner density control data check and toner density
correction quantity display
34Transfer current setting
4801Main/sub scanning magnification ratio adjustment
05SPF/RSPF mode sub scanning magnification ratio
adjustment in copying *2
08FAX magnification ratio adjustment (scan)
09FAX magnification ratio adjustment (print)
4901Flash ROM program writing mode (MCU)
02Flash ROM program writing mode (NNB)
5001Image lead edge adjustment
06Copy lead edge position adjustment (SPF/RSPF) *2
8FAX lead edge adjustment (scan)
10Print off-center adjustment
12Document off-center adjustment
18Memory reverse position adjustment in duplex copy *1
19Rear edge void adjustment in duplex copy *5
5102Resist amount adjustment
5308SPF/RSPF scanning position automatic adjustment *2
6102Laser power correction ON/OFF (Invalidity)
03HSYNC output check
6301Shading check
6401Self print
6510Key ACK time setting display/non-display setting
11Info lamp setting
Contents
Main
Sub
code
code
6601FAX soft SW setting
02FAX soft SW initializing
03FAX PWB memory check
04Signal send mode
06Confidential pass code print
07Image memory content output
10Image memory contents clear
11300bps signal send
13Dial number registration
17DTMF signal send
21FAX information print
24FAST SRAM clear
30TEL/LIU status change check
31TEL/LIU setting
32Receive data check
33Signal detection check
34Communication time measurement
37Speaker sound volume adjustment
38Time setting/check
42PC program writing
43PIC adjustment value writing
52Pseudo ringer check
6750USB reception speed adjustment
<Execution inhibit conditions>
*1) Execution is inhibited when the duplex setup is OFF and other than
RSPF is set.
*2) Execution is inhibited when OC.
*3) Execution is inhibited when SPF. (Not RSPF)
*4) Execution is inhibited when the job separator is not installed.
*5) Execution is inhibited when the model is not provided with the
CRUM.
*6) Execution is inhibited when the duplex setup is OFF.
Contents
MX-M182 SIMULATIONS 7-2
4. Contents of simulations
Main
code
0101Mirror scanning operation
Sub
code
Used to check the operations of the scanner unit and its control circuit.
Enter the number of times and the magnification ratio, and press [OK] key to operate the scanner unit. The
speed is variable according to the specified magnification ratio. The number of scanning can be specified by
entering a value to the right lower section of the LCD.
•Setting range of magnification ratio: 25%-400%
•Setting range of the number of scanning: 0-999 (When 0 is set, it means unlimited. )
(Scan number input window)
Sim1-1 SCAN CHECK
115 %
100%
86%
ZOOM 100%5
(Execution
window)
Sim1-1 SCAN CHECK
115 %
100%
86%
ZOOM 100%EXEC
MHPS
[OK] key or [START] Key
MHPS
123
123
ContentsRemark
Set the scan magnification ration.
This magnification ratio accords with the scan speed
in actual copying. The setting range is 25% - 400%.
Specify the scan number to be performed.
The setting range is 0 - 999. When 0 is set,
the number is unlimited.
MHPS sensor status
Scan counter
Highlighted during execution
Used to display the status (ON/OFF) of the mirror HP sensor on the LCD during scanning. (Highlighted at
ON)
"EXEC" is displayed to indicate execution is in process. The scan counter is displayed above "EXEC." This
counter is counted up even in simulation.
The copy lamp is lighted during scanning.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
[C] key: Input value clear
Numeric keys: Input of the number of scanning
02Mirror home positions sensor (MHPS) status display
Used to monitor the mirror home position sensor and display the ON/OF status of the sensor on the LCD.
Sim1-2 SENSOR CHECK
MHPS
MHPS(MIRROR HOME POSITION SENSOR)
ON :Highlight display
OFF :Normal display
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
MX-M182 SIMULATIONS 7-3
Main
r
code
Sub
code
ContentsRemark
0201Single Paper Feeder(SPF)/Reversing single pass feeder(RSPF)aging
Used to check the operations of the SPF/RSPF unit and its control circuit.
Enter the magnification ratio and press[OK] key or [START] key to drive the SPF/RSPF unit at the speed
corresponding to the setting.
(Magnification ratio selection window)
Sim2-1 SPF AGING
115 %
100%
86%
ZOOM 100% EXEC
(Execution
window)
Sim2-1 SPF AGING
115 %
100%
86%
ZOOM 100% EXEC
1SIDE
2SIDE
[OK] key or [START] Key
1SIDE
2SIDE
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying similarly to the OC.
The setting range is 50% - 200%.
"EXEC" is highlighted during execution.
*When [INTERRUPT] key is press, the simulation is terminated and the machine returns to the sub code
input window.
*When [CA] key is pressed, the simulation is terminated and the machine exits the simulation mode.
02SPF/RSPF sensor status display
Used to display the sensor status in the SPF/RSPF section. An active sensor is highlighted.
Sim2-2 SENSOR CHECK
SPFP
OCCV
POUT
SPFC
L1
L2
W0
W1
W2
W3
Displayed name : Sensor name
SPFP :SPF document transportation sensor
OCCV :SPF unit (OC cover) open/close sensor
POUT :SPF paper exit sensor
SPFC :SPF paper feed cover open/close senso
L1 :SPF paper length sensor 1
L2 :SPF paper length sensor 2
W0 :SPF document set sensor
W1 :SPF paper width sensor (small)
W2 :SPF paper width sensor (middle)
W3 :SPF paper width sensor (large)
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
03SPF/RSPF motor operation check
Used to check the operation of the SPF/RSPF motor and its control circuit. When this simulation is
executed, the initial menu shown below is displayed. Select the magnification ratio to drive the motor.
(Initial window = Magnification ratio selection window)
Sim2-3 OUTPUT CHECK
115 %
100%
86%
ZOOM 100% EXEC
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying.
The setting range is 50% - 200%.
Only when the SPF/
RSPF is installed.
Only when the SPF/
RSPF is installed.
[OK] key or [START] Key
(Execution
window)
Sim2-3 OUTPUT CHECK
115 %
100%
86%
ZOOM 100% EXEC
"EXEC" is highlighted during execution.
[CA] key: The SPF/RSPF motor is stopped, and the machine exits the simulation mode.
[INTERRUPT] key: The SPF/RSPF motor is stopped, and the machine returns to the sub code input window.
MX-M182 SIMULATIONS 7-4
Main
r
code
Sub
code
0208SPF/RSPF paper feed solenoid operation check
Used to drive the SPF/RSPF paper feed solenoid (PSOL) 20 times in the cycle of 500msec of "ON" and
500msec of "OFF." After completion of the process, the machine returns to the sub code input window.
(Initial window)(Execution window)
Sim2-8 SPUS CHECK
[OK] key or [START] Key
ContentsRemark
(Only when the
SPF/RSPF is
installed.}
Sim2-8 SPUS CHECK
PRESS OK KEY EXEC
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
09RSPF reverse solenoid operation check
Used to drive the RSPF reverse solenoid (RSOL) 20 times in the cycle of 500msec of "ON" and 500msec of
"OFF." After completion of the process, the machine returns to the sub code input window.
(Initial window)(Execution window)
Sim2-9 SPFS CHECK
PRESS OK KEY EXEC
[OK] key or [START] Key
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
11SPF/RSPF PS release solenoid operation check
Used to drive the SPF/RSPF PS release solenoid (CLH) 20 times in the cycle of 500msec of "ON" and
500msec of "OFF." After completion of the process, the machine returns to the sub code input window.
(Initial window)(Execution window)
Sim2-11 CLH CHECK
PRESS OK KEY EXEC
[OK] key or [START] Key
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
0302Shifter/job separator sensor status display
Used to monitor the sensors related to the shifter and the job separator and display the sensor status on the
LCD. An active sensor is highlighted.
Sim3-2 SENSOR
SFTHP
TRYF
JSUP
TRYD
JSDL
Displayed name :Sensor name
SFTHP :Shifter home position sensor
JSUP :Job separator upper limit senso
JSDL :Job separator lower limit sensor
TRYF :Tray full sensor
TRYD : Paper exit sensor
*Displayed only when the job separator is installed except for SFTH.
EXEC
(Only when the
RSPF is installed.)
Sim2-9 SPFS CHECK
EXEC
(Only when the
SPF/RSPF is
installed.)
Sim2-11 CLH CHECK
EXEC
(Sensor of shifter is
Japan only)
(Only when the job
separator is
installed.)
MX-M182 SIMULATIONS 7-5
Main
r
code
Sub
code
0303Shifter operation check
Used to reciprocate the shifter 4 times.
During execution, the status of the shifter HP sensor is displayed on the right upper section of the screen.
(When the sensor is detected, the display is highlighted.)
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
*When the above [CA] key or [INTERRUPT] key is pressed during operation of the shifter, the shifter is
returned to the home position before terminating the operations.
(Initial window)(Execution window)
Sim3-3 SHIFTER CHK
[OK] key or [START] Key
ContentsRemark
Japan only
Sim3-3 SHIFTER CHK
SFTHP
PRESS OK KEY EXEC
EXEC
04Job separator operation check
Used to operate the job separator up and down for 30sec.
During operation, the status of the upper limit sensor and the lower limit sensor is displayed on the right
upper section of the display.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
When the operation is interrupted, the job separator is shifted to the home position before terminating the
simulation similarly to the shifter.
(Initial window)(Execution window)
Sim3-4 JOBSEPA CHK
PRESS OK KEY EXEC
[OK] key or [START] Key
Sim3-4 JOBSEPA CHK
JSUP
JSDL
EXEC
Display
name
JSUPJob separator
JSDLJob separator
Sensor
upper limit senso
lower limit sensor
11Shifter home position check
Used to check the operations of the shifter HP sensor and the shifter. When this simulation is executed, the
initial menu is displayed. By the following key operations, the left operation and the right operation of the
home position sensor and the shifter can be executed separately.
[ ] key: Shifts to R side by the specified steps.
[ ] key: Shifts to F side by the specified steps.
[ ] key: Shift to the home position.
[SFTHP] is highlighted when the HP sensor is detected.
(Initial window)
Sim3-11 SHIFTER CHK
SFTHP
(Only when the job
separator is
installed.)
name
Japan only
[ ]:R [ ]:HP [ ]:F
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
MX-M182 SIMULATIONS 7-6
Main
code
Sub
code
0501Operation panel display check
<LED/LCD check mode>
Used to check the operations (ON, display) of the LED and the LCD on the operation panel.
When this simulation is executed, all LED's on the operation panel (including 7SEG) are lighted and
checking LCD is started.
For the operation check of LCD, the area is divided into two sections; upper section and lower section, and
the display cycle of Normal
2sec.
ContentsRemark
Dark Light Off is repeated in each section. Each display period is
Normal
Sim5-1 LCD/LED CHK.
Normal
Sim5-1 LCD/LED CHK.
Off
Sim5-1 LCD/LED CHK.
Dark
Sim5-1 LCD/LED CHK.
Dark
Sim5-1 LCD/LED CHK.
Sub code input standby window
Light
Sim5-1 LCD/LED CHK.
Light
Sim5-1 LCD/LED CHK.
When [INTERRUPT] key is pressed in the LED check mode, the machine returns to the sub code input
window.
When [CA] key is pressed, the machine exits the simulation mode.
When [START] key is pressed during LCD display, the machine goes to the key input check mode.
<Key input check mode>
Used to check that the keys on the operation panel are properly detected.
When the machine enters the key input check mode, the initial menu is displayed.
(Initial window)
Sim5-1 LCD/LED CHK.
0
When any key is pressed, the value on the right lower side is counted up.
If a key is pressed once, it is not counted again.
When [CA] key is pressed for the first time, it is counted. When it is pressed for the second time, the
simulation mode is terminated.
When [INTERRUPT] key is pressed for the first time, it is counted. When it is pressed for the second time,
the window returns to the sub code input standby window.
*Note for the key input check mode
[START] key must be pressed at the end. If it is pressed midway, the simulation judges that the last key
is pressed and terminates the check mode. Multi input of tow or more keys is ignored.
MX-M182 SIMULATIONS 7-7
Main
code
Sub
code
0502Fusing lamp and cooling fan operation check
Used to check the operations of the heater lamp and the cooling fan and the peripheral circuits.
When this simulation is executed, the following initial menu is displayed.
(Initial window)(Execution window)
Sim5-2 HT LAMP
[OK] key or [START] Key
ContentsRemark
Sim5-2 HT LAMP
PRESS OK KEY EXEC
When this simulation is executed, the fusing lamp repeats ON/OFF 5 times in the cycle of 500ms.
The cooling fan motor is rotated during that period. (The cooling fan, however, is rotated for about 8sec.)
After completion of the operation, the machine returns to the sub code input window.
03Copy lamp lighting check
Used to check the operations of the copy lamp and its peripheral circuit.
When this simulation is executed, the following initial menu is displayed.
(Initial window)(Execution window)
Sim5-3 COPY LAMP
PRESS OK KEY EXEC
[OK] key or [START] Key
When [OK] key or [START] key is pressed, the copy lamp is lighted for about 5sec.
After passing for 5sec, the machine returns to the sub code input window.
0601Paper feed/transport solenoid operation check
When this simulation is executed, the names of the solenoids which can be operated are displayed. Select a
load to be operated with the numeric keys.
(Load selection window)
Sim6-1 OUTPUT CHECK
1:CPSOL
2:PSOL1
3:PSOL2
(Load selection window)
Sim6-1 OUTPUT CHECK
1:CPSOL
2:PSOL1
3:PSOL2
4:PSOL3
5:HPSOL
6:FSOL2
EXEC1/21
Numeric keys
4:PSOL3
5:HPSOL
6:FSOL2
EXEC1/22
1: CPSOL :Cassette 1 paper feed solenoid
2: PSOL1 :Cassette 2 paper feed solenoid (*)
3: PSOL2 :Cassette 2 paper feed solenoid (*)
4: PSOL3 :Cassette 3 paper feed solenoid (*)
5: HPSOL :Manual feed tray paper feed solenoid
6: FSOL2 :Cassette 2 transport solenoid (*)
7: FSOL3 :Cassette 3 transport solenoid (*)
(*) Supported only for the model with the option installed.
Skipped for the other models without installation.
After completion
of execution
EXEC
Sim5-3 COPY LAMP
EXEC
[OK] key or [START] Key
(Execution window)
Sim6-1 OUTPUT CHECK
1:CPSOL
2:PSOL1
3:PSOL2
4:PSOL3
5:HPSOL
6:FSOL2
EXEC1/22
During execution, the selected solenoid repeats
ON/OFF 20 times for every 500ms.
02Resist roller solenoid (RRS) operation check
When this simulation is executed, the machine goes to the execution start window. When [OK] key or
[START] key is pressed, the resist roller solenoid (RRS) repeats ON of 500ms and OFF of 500ms 20 times.
(Execution start window)(Execution window)
Sim6-2 RRS CHECK
PRESS OK KEY EXEC
[OK] key or [START] Key
Sim6-2 RRS CHECK
EXEC
When the operation is completed, the machine returns to the sub code input window.
When [INTERRUPT] key is pressed, the machine returns to the sub code input window. When [CA] key is
pressed, the machine exits the simulation mode.
MX-M182 SIMULATIONS 7-8
Main
code
Sub
code
0701Warm-up display and aging with jam detection
Used to measure the warm-up time and execute aging with jam detection.
When this simulation is executed, the following warm-up window is displayed.
The time required for starting the warm-up and completing the initializing operation and shifting to the standby state is displayed.
After completion of warm-up, press [CA] key to exit the simulation mode, allowing normal copy operations.
The copy mode at that time is the aging mode with 0sec of intermittent aging.
(Warming up window)
Sim7-1 W-UP C-MODE
WARMING UP.
(Warming up completion window)
Sim7-1 W-UP C-MODE
WARM UP COMPLETED.
ContentsRemark
(Copy window)
[CA] key
Ready to copy.
S
1
10
100%
8 1/2×11
Canceled by turning off the power or executing a simulation which makes the hardware reset. When the
interruption is pressed to shift to the input standby window, the machine does not enter the aging mode.
06Intermittent aging
Used to execute intermittent aging of 3sec. The set quantity and the mode are optionally selected.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the machine exits the simulation mode.
Enter a desired coy mode and a desired copy quantity.
Press [START] key, and intermittent aging will be started.
(Execution start window)
Sim7-6 INTERVAL SET
AGING INTERVAL
AER YOU SURE? EXEC
(Copy window)
Ready to copy.
S
100%
8 1/2×11
It is canceled by turning off the power or executing a simulation with the hard reset.
08Shifting with warm-up display
Used to measure the warm-up time.
When this simulation is executed, the following warm-up window is displayed.
The time required for starting the warm-up and completing the initializing operation and shifting to the standby state is displayed.
*Though [CA] key is pressed, the machine does not enter the aging mode of intermission 0 sec.
(Warming up window)
Sim7-8 W-UP C-MODE
WARMING UP.
(Warming up completion window)
Sim7-8 W-UP C-MODE
WARM UP COMPLETED.
Press [CA] key to exit the simulation mode.
(The aging function is omitted from SIM 07-01.)
Note: Toner supply operation is not performed during this simulation.
0801Developing bias output
Used to check the developing bias output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the developing bias signal is turned ON for 30sec. When
measuring the actual output value, however, use SIM 25-01.
After completion of the process, the machine returns to the sub code input window.
(Execution start window)(Execution window)
Sim8-1 DV BIAS
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts output operation and shifts to the sib code input window.
1
[OK] key or [START] Key
10
Sim8-1 DV BIAS
EXEC
MX-M182 SIMULATIONS 7-9
Main
Window display Output mode
1:NML_A Normal size width (front)
2:NML_B Normal size width (back)
3:SML_A Small size width (front)
4:SML_B Small size width (back)
code
Sub
code
0802Main charger output (Grid = HIGH)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage HIGH
mode.
After completion of the process, the machine returns to the sub code input window.
(Execution start window)(Execution window)
Sim8-2 MHV(H)
[OK] key or [START] Key
ContentsRemark
Sim8-2 MHV(H)
PRESS OK KEY EXEC
EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts output operation and shifts to the sub code input window.
03Main charger output (Grid = LOW)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage LOW
mode.
After completion of the process, the machine returns to the sub code input window.
(Execution start window)(Execution window)
Sim8-3 MHV(L)
PRESS OK KEY EXEC
[OK] key or [START] Key
Sim8-3 MHV(L)
EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts output operation and shifts to the sub code input window.
06Transfer charger output
When this simulation is executed, the machine shifts to the following mode select window, and the list of the
modes to be outputted is displayed.
Select an output mode with numeric keys and press [OK] key or [START] key, and the transfer charger
output is made for about 30sec in the specified mode.
(Mode selection window)
Sim8-6 TC OUTPUT
1:NML_A
2:NML_B
3:SML_A
4:SML_B
5:BYPASS
EXEC
[OK] key or [START] Key
2
(Execution window)
Sim8-6 TC OUTPUT
1:NML_A
2:NML_B
3:SML_A
4:SML_B
5:BYPASS
EXEC
2
*The items of (back) is not displayed when DUPLEX setting is OFF.
*Small size paper is Letter R (A4R) width or below. When an output is completed, the machine shifts to
the mode select window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
MX-M182 SIMULATIONS 7-10
Main
code
Sub
code
0901Duplex motor forward rotation check
Used to check the duplex motor rotation.
The duplex motor is rotated in the normal direction (paper exit direction) for 30sec.
After completion of the process, the machine shifts to the sub code input window.
(Execution start window)(Execution window)
Sim9-1 DMF CHECK
[OK] key or [START] Key
ContentsRemark
(Execution is not
allowed when
DUPLEX setting is
OFF.)
Sim9-1 DMF CHECK
PRESS OK KEY EXEC
EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
02Duplex motor reverse rotation check
Used to check the duplex motor reverse rotation.
The duplex motor is rotated in the reverse direction for 30sec.
After completion of the process, the machine shifts to the sub code input window.
(Execution start window)(Execution window)
Sim9-2 DMR CHECK
PRESS OK KEY EXEC
[OK] key or [START] Key
Sim9-2 DMR CHECK
EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
04Duplex motor RPM adjustment
Used to adjust the duplex motor rotation speed.
When this simulation is executed, the following setting window is displayed. Enter an input value with
numeric keys and press [OK] key or [START] key.
The setting range is in 1-13 steps.
(Setting window)
Sim9-4 MOTOR SPEED
1:MOTOR SPEED
• 18cpm/20cpm machine:
Set value : Speed (PPS)
01 : 637.2PPS (Slow)
When a value outside the setting range is inputted, it is ignored.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shift to the sub code input window.
05Duplex motor switchback time adjustment
Used to adjust the duplex motor switchback time when the motor reverse rotation is controlled.
When this simulation is executed, the following setting window is displayed. Enter an input value with
numeric keys and press [OK] key or [START] key.
The setting range is 50-76.
When the adjustment value is increased by 1, the distance up to reverse start is increased by 3 steps in 1-2
phase excitement.
Sim9-5 SW BACK TIME
1:SW BACK TIME
50
(Execution is not
allowed when
DUPLEX setting is
OFF.)
Default:
4
Default:
50
50[ 50-76]
When a value outside the setting range is inputted, it is ignored.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shift to the sub code input window.
MX-M182 SIMULATIONS 7-11
Main
code
Sub
code
10-Toner motor operation
Used to check the operation of the toner motor.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key, and the toner motor is rotated for about 30sec.
After completion of the process, the machine shifts to the sub code input window.
(Execution start window)(Execution window)
Sim10 TONER MOTOR
[OK] key or [START] Key
ContentsRemark
Sim10 TONER MOTOR
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
14-Trouble cancel (except for U2)
* Used to cancel EEPROM writing troubles such as H trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key to clear the trouble other than U2.
(Execution start window)
Sim14 TROUBLE CLEAR
TROUBLE CLEAR
(WITHOUT U2)
AER YOU SURE? EXEC
16-U2 trouble cancel
*Used to cancel the U2 trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key to clear the U2 trouble.
(Execution start window)
Sim16 TROUBLE CLEAR
U2 TROUBLE CLEAR
AER YOU SURE? EXEC
2001Maintenance counter clear
EXEC
Used to clear the maintenance counter.
Press [OK] key or [START] key on the following window, the maintenance counter is cleared and the
machine returns to the sub code input window.
Sim20-1 COUNTER CLR
MAINTENANCE COUNTER
CLEAR
AER YOU SURE? EXEC
2101Maintenance cycle setting
Used to set the maintenance cycle. When this simulation is executed, the current set value is displayed.
Enter a desired code with numeric keys and press [START] key. The set value is saved in the EEPROM and
the machine returns to the sub code input window.
Sim21-1 CYCLE SET.
1:MAINTE CYCLE
4
4[ 0- 5]
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
Counter display
TOTAL : Total counter
MAINTE : Maintenance counter
DEV : Development counter
DRUM : Drum counter
CPY JOB : Copy job counter
PRT JOB : Print job counter
SCN JOB : Scan job counter
OC SCN : OC scan counter
SPF : SPF/RSPF counter
DUPLEX : DUPLEX counter
OTHERS : Other counter
MNTCYC : Maintenance cycle
DEV TTL : Development rotation accumulated time
DRM TTL : Drum rotation accumulated time
Though SIM26-74 is set to "1: Scan counter is added," the count is not added to SIM22-01 total counter
display. The setting affects only the total counter display in the system settings.
03Jam memory display
Used to check the jam kind occurred in the main unit and the SPF/RSPF.
The kinds of jams up to 30 items are displayed sequentially from the latest one. (The oldest one is deleted
sequentially.) This display is used for troubleshooting. (If there are extremely many troubles in a position, it
may be judged that a repair must be executed.)
The kinds and contents of jams to be displayed are as follows.
*TRAY2-TRAY4 are displayed only when they are installed.
11FAX-related counter display.
key
key
ContentsRemark
Sim22-9 COUNTER 2/2
TRAY4 : nnnnnnn
Used to display the current FAX send/receive counter value.
13CRUM destination display
Used to display the CRUM chip destination code saved in the EEPROM. If the display does not match the
destination code saved in the CRUM chip, it is judged as an error.
*This simulation is valid only for the model with the CRUM chip.
Sim22-13 CRUM
CRUM TYPE nn
Number : Setting (Destination)
00 : Not set.
01 : Destination-A (North America)
02 : Destination-B (Europe)
03 : Destination-C (SMEF)
04 : CHN-A
14P-ROM version display
Sim22-14 ROM VER1/2
S/N : -----------
05 : JPN-A
Sim22-14 ROM VER2/2
FAX : --.-MCU : --.-NNB : --.-PNL : --.--
The version of the option board which is not installed is not displayed.
In this case, (1) is the latest one and (12) is the oldest.
22SPF/RSPF jam counter display
Used to display the SPF/RSPF JAM counter.
When [INTERRUPT] key is pressed, the machine goes to the sub code input window. When [CA] key is
pressed, the machine exits the simulation mode.
Sim22-22 JAM CNT
SPF : nnnnnnn
key
key
ContentsRemark
XX-XX XX-XX XX-XX
XX-XX XX-XX XX-XX
XX-XX XX-XX
(Only when the
SPF/RSPF is
installed.)
2401Jam total counter clear
When this simulation is executed, the clear confirmation window is displayed as shown below.
When [OK] key or [START] key is pressed, the jam total count and the jam memory are cleared and the
machine shifts to the sub code input window.
Sim24-1 COUNTER CLR
JAM COUNTER CLEAR
AER YOU SURE? EXEC
02Trouble memory clear
Used to clear the trouble memory and the trouble history data in the EEPROM.
When [INTERRUPT] key is pressed, the machine shifts to the sub code input window. When [CA] key is
pressed, the machine exits the simulation mode.
Sim24-2 COUNTER CLR
TROUBLE
CLEAR
AER YOU SURE? EXEC
COUNTER
04SPF/RSPF counter clear
Used to clear the SPF/RSPF paper feed counter.
Sim24-4 COUNTER CLR
SPF
COUNTER
CLEAR
AER YOU SURE? EXEC
(Only when the
SPF/RSPF is
installed.)
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
MX-M182 SIMULATIONS 7-15
Main
code
Sub
code
2405Duplex print counter clear
Used to clear the duplex print counter.
Sim24-5 COUNTER CLR
DUPLEX
COUNTER
CLEAR
AER YOU SURE? EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
06Paper feed counter clear
Used to clear the paper feed counter data in each paper feed section.
*TRAY2-TRAY4 are displayed only when they are installed.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
07Drum counter clear
Numeric
Key
[C] Key
ContentsRemark
[OK] key or
2
[START] key
Return
[OK] key or
[START] key
1:BYPASS
2:TRAY1
3:TRAY2
ARE YOU SURE?
4:TRAY3
5:TRAY4
2
1:BYPASS
2:TRAY1
3:TRAY2
4:TRAY3
5:TRAY4
(Execution is not
allowed when
DUPLEX setting is
OFF.)
Used to clear the drum counter and the drum rotating time.
Sim24-7 COUNTER CLR
DRUM
COUNTER
CLEAR
AER YOU SURE? EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
08Copy counter clear
Used to clear the copy counter.
Sim24-8 COUNTER CLR
COPIES
COUNTER
CLEAR
AER YOU SURE? EXEC
[OK] key or [START] key: Clears the copy counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
09Printer counter clear
Used to clear the printer counter and other counters.
Select a counter to be cleared and press [OK] key or [START] key. The confirmation window is displayed.
Press [OK] key or [START] key again, and the specified counter is cleared and the machine returns to the
initial window.
Numeric key input
Sim24-9 COUNTER CLRSim24-9 COUNTER CLR
1:PRINT
2:OTHER
[OK] key or
[START] key
1:PRINT
2:OTHER
1
[BACK] key
[OK] key or [START] key (Counter clear)
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
MX-M182 SIMULATIONS 7-16
1ARE YOU SURE?
Main
code
Sub
code
2410FAX-related counter clear
Used to clear the current FAX send/receive counter value (number of pages of send/receive), the
accumulated time of send/receive, and the print counter to 0.
ContentsRemark
Sim24-10 CLR COUN.
CLEAR FAX COUNTER
1:SEND
2:RECEIVE
(1 - 3) X
[1] key[2] key
[OK] key[OK] key
Sim24-10 CLR COUN.
SEND
PAGE: xx, xxx, xxx
TIME: hhhhhhhh:mm:ss
EXEC
[OK] key[OK] key
Sim24-10 CLR COUN.
SEND COUN. CLEARED
ReturnReturnReturn
When the number of pages of send is cleared, the PC-FAX counter is also cleared.
CA key : Simulation cancel
Interrupt key : Sub code input window
[3] key
[OK] key
Sim24-10 CLR COUN.
PRINT PAGE
xxxxxxxx
EXEC
[OK] key
Sim24-10 CLR COUN.
FAX COUN. CLEARED
[OK] key or [START] key: Clears the scanner counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
14SPF/RSPF jam total counter clear
Used to clear the SPF/RSPF jam total counter.
Sim24-14 COUNTER CLR
SPF JAM
COUNTER
CLEAR
AER YOU SURE? EXEC
[OK] key or [START] key: Clears the SPF/RSPF jam total counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
15Scanner mode counter clear
Used to clear the scanner mode counter.
Sim24-15 COUNTER CLR
SCANNER MODE
COUNTER
CLEAR
AER YOU SURE? EXEC
[OK] key or [START] key: Clears the scanner mode counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
(Only when the
SPF/RSPF is
installed.)
MX-M182 SIMULATIONS 7-17
Main
code
Sub
code
ContentsRemark
2501Main motor operation check (Cooling fan motor rotation check)
When [OK] key or [START] key is pressed, the main motor (as well as the duplex motor in the case of the
duplex model) is rotated for 30 sec.
If the developing unit is installed to save toner consumption at that time, the developing bias, the main
charger, and the grid are also outputted.
In addition, since laser discharge is required when the motor is stopped, the polygon motor is also operated.
Check if the developing unit is installed or not. If it is not installed, the previous high voltage is not outputted
and only the motor is rotated.
After completion of 30sec operation, the machine shifts to the sub code input window.
*This simulation must not be executed with the door open/close switch forcibly turned ON.
(Execution start window)(Execution window)
Sim25-1 MAIN MOTOR
[OK] key or [START] Key
Sim25-1 MAIN MOTOR
PRESS OK KEY EXEC
EXEC
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
02Auto developer adjustment (Initial setting of toner density when replacing developer)
To execute this simulation, perform the following procedures.
[Procedures]
1) Check to confirm that the machine power is turned OFF. Install the DV unit.
2) With the cover open, turn ON the machine power.
3) The machine goes to the SIM25-02 mode. ("Cover open MSG" is displayed. Start LED: OFF.)
4) Close the side cover. (Start LED:ON)
5) Press [OK] key or [START] key.
When [OK] key or [START] key is pressed, the main motor rotates for 3 minutes to determine the toner
sensor reference value and clear the developer rotation time, in addition, the developer counter is cleared.
When the procedures are completed normally, the ATC sensor reference value is displayed on the value
display section. In case of an error, the following screen is displayed.
(Execution start)
Sim25-2 AutoDv ADJ.
(Executing)
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
PRESS OK KEY EXEC
(Normally completed)(EL error)(EU error)
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
COMPLETE
[nnn]
[OK] key or [START] Key
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
EL trouble
[nnn]
DEVELOPER ADJUST
[nnn]
EXEC
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
EU trouble
[nnn]
Note:
When the machine is not in the simulation mode, if the front cover is closed and the machine power is turned
ON, toner may be supplied from the toner cartridge to the developer cartridge.
Under this state, the toner density reference control level adjustment cannot be performed properly.
If, therefore, the front cover is closed and the machine power is turned ON when the machine is not in the
simulation mode, dispose developer, supply new developer, and adjust the toner density reference level.
It takes about 3 minutes to complete the SIM25-02. Never open the front cover or turn OFF the machine
power during execution of this simulation.
MX-M182 SIMULATIONS 7-18
Main
Window displayCode numberSetting
1: B4/LG, FC0FC detection disable (The set values to items marked with
are ignored.)
1(Follows the setting of items below marked with .)
When [OK] key or [START] is pressed, the polygon motor is rotated for 30sec.
(Execution start window)(Execution window)
Sim25-10 LSU CHECK
[OK] key or [START] Key
ContentsRemark
Sim25-10 LSU CHECK
PRESS OK KEY EXEC
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
2601Job separator setting
Used to set YES/NO of installation of the hob separator.
After installation of the job separator, setting must be manually set to YES.
Sim26-1 JBS SET
1:JOB SEPARATOR
0=NONE
1=SEPARATOR
[ 0-1]
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and
performs the hard reset.)
[INTERRUPT] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
(When setting is changed, the machine does not shift to the code input window.)
02Size setting
Used to set Enable/Disable of FC (8.5" x 13") size detection and mexican legal size detection.
0 : No job separator
1 : Job separator provided
0
0
EXEC
Detection size when FC (8.5" x 13") size and mexican legal size document is used.
* For destinations other than the above, this setting is invalid.
Sim26-2 SIZE SET
1:B4/LG,FC
2:Use Max Legal 0
[ 0-1]
Code: Setting
0 : Detection disabled
0
1 : FC detection enabled
0
MX-M182 SIMULATIONS 7-19
Main
SettingTotal/DeveloperMaintenance
0+2+2
1+1+2
2+2+1
3+1+1
code
Sub
code
2603Auditor setting
Used to set the auditor.
Sim26-3 AUDITOR SET
1:AUDITOR
0=P10 1=VENDOR
2=OTHER
[ 0-2]
*When the coin vendor mode is selected:
1. Sort auto select is OFF.
2. For Japan, the duplex copy use inhibition setting is ON (inhibited).
3. When the auditor mode exclusive-setting is ON (manual paper feed inhibited) and the standard tray is set
to the manual feed tray, the standard tray setting is set to the main tray.
04Copier duplex setting
Used to set YES/NO of duplex setting.
This must be set to ON when the duplex unit is installed. If this setting is set to OFF on the duplex machine,
the duplex motor does not rotate and paper is not discharged normally, resulting in a paper jam.
Sim26-4 DUPLEX SET
1:DUPLEX
0=OFF 1=ON
[ 0-1]
Code: Mode
0 : Built-in auditor mode
0
1 : Coin vendor
2 : Other
0
Code: Duplex setting
0 : OFF
0
1 : ON
0
ContentsRemark
Default:
0
Default:
0: MX-M182
1: MX-M182D
MX-M202D
MX-M232D
05Count mode setting
Used to set the count-up number of the total counter, the developer counter, and the maintenance counter
individually when a special paper (A3/WLT/8K) is passed.
When this simulation is executed, the current set value is displayed.
Sim26-5 COUNT MODE
1:COUNT MODE
[ 0-3]
1
1
[1]-[3]:
Enter a value with numeric keys, and press [OK] key or [START] key to save the current adjustment value to
the EEPROM. The machine returns to the sub code input window.
Default:
0
MX-M182 SIMULATIONS 7-20
Main
code
Sub
code
2606Destination setting
Used to set the destination of the main unit.
When this simulation is executed, the code number of currently set destination is displayed.
Sim26-6 DESTINATION
1:DESTINATION
0=JAPAN
[ 0-6]
[0] - [6] (Default: Depends on the model.)
Enter a value with numeric keys, and press [OK] key or [START] key, and the current adjustment value is
saved in the EEPROM.
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and
performs the hard reset.)
[INTERRUPT] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
(When setting is changed, the machine does not shift to the code input window.)
*When this setting is changed, the following adjustment values and the set values are automatically
changed according to the set destination.
O SIM46-19 ( table setting)
O SIM46-30 (AE limit setting)
O Paper size (A4 for AB series, LT for inch series)
O Maintenance cycle (Returns to the default (Japan/Ex Japan). )
O Mini maintenance cycle (Only when setting is changed to Japan.)
07Machine condition check
ContentsRemark
Code :Setting
0=JAPAN : Japan AB series
0
1=INCH : Inch series
2=AB : Ex Japan AB series
3=INCH(FC) : Ex Japan inch series (FC)
0
4=AB(FC) : Ex Japan AB series (FC)
5=CHINESE : China (EX Japan AB series + Chinese paper support)
6=TAIPEI : Taiwan (EX Japan AB series + Chinese paper support)
(Setting range 0 - 6)
Default:
Differs depending
on each destination.
When this simulation is executed, the copy speed of the machine is displayed.
Sim26-7 CPM CHECK
18CPM
Displayed CPM list
18CPM
20CPM
23CPM
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
08Manual transfer shaking countermeasures setting
Used to set the countermeasures against manual transfer shaking.
When this simulation is executed, the current set value is displayed. Enter a set value with numeric keys and
press [OK] key or [START] key. The set value is saved in the EEPROM.
Sim26-08 TC FADE SET
1:TC FADE
0=OFF 1=ON
[ 0-1]
Code: Setting
0: Manual transfer shaking countermeasures OFF
0
1: Manual transfer shaking countermeasures ON
0
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
18Toner save mode setting
Used to switch ON/OFF of the toner save mode.
When this simulation is executed, the current set value is displayed. Enter a set value with numeric keys and
press [OK] key or [START] key. The set value is saved in the EEPROM.
*When this setting is changed, the toner save setting of the system settings is also changed accordingly.
Sim26-18 TONER SAVE
1:TONER SV MODE
0=OFF 1=ON
[ 0-1]
Code: Setting
0: Toner save OFF
0
1: Toner save ON
0
Default:
0
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
MX-M182 SIMULATIONS 7-21
Main
code
Sub
code
2620Job separator paper exit mode setting
Used to set the paper exit mode of the job separator.
*The purpose is to allow the simplified check when the job separator option is installed. It is valid only
during the adjustment simulation. Without installing a printer or a FAX machine, paper is discharged to
the upper stage to check if there is no problem or not.
If SIM26-01 is set to "Job separator not installed," paper is discharged to the lower stage regardless of
this setting.
Sim26-20 JOBSEP OUT
1:JOBSEP OUT
0=OFF 1=ON
[ 0-1]
0
0
Code: Setting
0: Lower tray
1: Upper tray
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
22Language setting clear
Used to clear the language setting. The scanner head is shifted to the fixing lock position.
(Intial display)
Sim26-22 LANGUAGE
LANGUAGE SETTING
CLEAR
AER YOU SURE? EXEC
[OK] key or [START] Key
ContentsRemark
Default:
0
(Execution is started)
Sim26-22 LANGUAGE
LANGUAGE SETTING
CLEAR
EXEC
Sim26-22 LANGUAGE
PLEASE SHUT OFF
THE POWER.
After completion of counter clear
and shifting to the lock position.
30CE mark conformity control ON/OFF
Used to set Yes/No of CE mark conformity.
When this simulation is executed, the current set value is displayed. Enter a value with numeric keys and
press [OK] key or [START] key. The set value is saved to EEPROM and the machine returns to the sub code
input window.
Sim26-30 CE MARK
1:CE MARK CTRL
0=OFF 1=ON
[ 0-1]
Code: Setting
0 : CE mark support control OFF
0
1 : CE mark support control ON
0
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
0: 100V series
1: 200V series
MX-M182 SIMULATIONS 7-22
Main
Code: Setting
0 : Stop
1 : Cancel of stop
Sim26-37 DEVE STOP
1:DEV LIFE OVER
[ 0 - 1]11
code
Sub
code
2631Auditor mode exclusive setup
Used to set whether paper feed is allowed from the manual paper feed tray of not when the auditor is set to
the coin vendor mode.
Sim26-31 AUDITOR
1:AUDITOR
[ 0-2]
Code: Setting
0 : Exclusive setting OFF (Manual paper feed enable)
1
1 : Exclusive setting ON (Manual paper feed disable)
2 : Exclusive setting OFF (Manual paper feed enable) + A3/WLT charge
1
*When this setting is set to ON, if the auditor mode is the coin vendor mode and the standard tray setting
is set to the manual paper feed tray, the standard tray setting is set to the main tray.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
36Cancel of stop at maintenance life over
"Stop" or "Cancel of stop" can be selected when the maintenance counter reaches the life over.
Sim26-36 MAINTESTOP
1:MAINTE OVER
Code: Setting
0 : Stop
1
1 : Cancel of stop
ContentsRemark
Default:
1
Default:
1
[ 0-1]
1
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code entry menu.
37Cancel of stop at developer life over
"Stop" or "Cancel of stop" can be selected when the developer counter reaches the life over..
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code entry menu.
39Memory capacity check
Used to check the capacity of the image memory (SDRAM) installed to the MCU PWB and the capacity of
the IMC compression memory.
Sim26-39 MEMORY CHK
MCU : 128Mbyte
There are two kinds of the displayed image memory capacity: 16MB and 32MB.
The standard capacity of the IMC compression memory is 16B.
* It is not displayed when IMC is not installed.
Default:
1
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
MX-M182 SIMULATIONS 7-23
Main
1:TC(ON)2:TC(OFF)
PS release TC ONPIN OFF TC OFF
Set valueTime (ms)Difference (ms)Set valueTime (ms)Difference (ms)
99442+12299402+98
• • •• • •• • •• • •• • •• • •
50344+2451306+2
• • •• • •• • •503040
38320049302-2
• • •• • •• • •• • •• • •• • •
1246-741206-98
1:TC(ON)2:TC(OFF)
PS release TC ONPIN OFF TC OFF
Set valueTime (ms)Difference (ms)Set valueTime (ms)Difference (ms)
993671019933482
• • •• • •• • •• • •• • •• • •
5028620512542
• • •• • •• • •502520
38266049251-1
• • •• • •• • •• • •• • •• • •
1204-621171-81
code
Sub
code
2642Transfer ON/OFF timing control setting
Used to set the ON/OF timing of the transfer charger (TC) individually. Select an item to be changed with the
arrow keys, and change the set value to a desired value, and press [OK] key or [START] key. The entered
value is saved to the EEPROM and the machine shifts to the sub code input window.
In the case of 88mm/s, when the set value is increased by 1, the timing is increased by 2ms.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
43Side void amount setting
Used to set the left and right side void amounts. The left side void amount and the right side void amount
can be set individually. Select an item to be changed with the arrow keys and change the set value to a
desired value. The setting range is 0-10. When the value is increased by 1, the void amount is increased by
0.5mm. The default is 5 (= 2.5mm).
(Item selection)
Sim26-43 SIDE VOIDSim26-43 SIDE VOIDSim26-43 SIDE VOID
1:SIDE VOID(L)
2:SIDE VOID(R)
[ 0- 10]
Display: Set item
1:SIDE BOID(L) : Left side void amount setting
2:SIDE VOID(R) : Right side void amount setting
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Key, Key
3
3
3
(Value input)(Settlement)
1:SIDE VOID(L)
2:SIDE VOID(R)
[ 0- 10]
Numeric Key
3
3
4
2
MX-M182 SIMULATIONS 7-24
1:SIDE VOID(L)
2:SIDE VOID(R)
[ 0- 10]
[OK] key or [START] Key
Default:
5 (Void amount:
2.5mm)
4
3
4
Main
Sim26-56 LIFE SET
1:AE1
2:AE2
3:TEXT
1/3 [ 0- 1]
1
1
1
1
Sim26-56 LIFE SET
4:PHOTO 1
5:PHOTO 2
6:AE(TS)1
2/3 [ 0- 1]
: PHOTO(Dither) life correction
: TSAE1 life correction
: TSAE2 life correction
: TSTEXT life correction
FAX P W B
SettingYesNo
0 (Enable)FAX window display FAX not-installed display
1 (Disable)FAX window display Error beep sound
code
Sub
code
2651Copy temporary stop function setting
Used to set whether copying is stopped temporarily when the paper exit tray full is detected. When the
electronic sort function is used, paper exit of 250 sheets (*1) or more can be used for one copy job. If, at that
time, copying (paper discharge) is continued with the tray full, a paper exit jam may occur. To avoid this,
copying is temporarily stopped by this setting.
(*1) 150 sheets when the job separator is installed.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
54LCD contrast PWM duty setting
Used to set the PWM duty (brightness) at the center value of LCD contrast.
*Setting range: 30-70
*When [OK] key or [START] key is pressed, the set value of LCD contrast is immediately reflected.
Sim26-54 LCD DUTY
1:LCD PWM DUTY
50
ContentsRemark
Default:
1
Default:
50
[ 30- 70]
50
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
56Life correction ON/OFF setting
The image correction ON/OFF setting is made according to the usage level (life) of developer.
When this simulation is executed, the list of the modes and the current set value are displayed on the LCD.
Select an item to be changed with the arrow keys, and change the set value to the required value.
(1=ON [Enable], 0=OFF [Disable])
When [OK] key or [START] key is pressed, the setting is saved to the EEPROM.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
60[FAX] key Enable/Disable setting
Used to set Enable/Disable of the [FAX] key when the FAX PWB is not installed.
Though this setting is set to Enable, if the FAX PWB is not installed, a message of "FAX PWB is not
installed" is displayed.
*When the FAX PWB is installed, the display shifts to the FAX window regardless of this setting.
Sim26-60 FAX KEY
1:FAX KEY MODE
Default:
1: 1
2: 1
3: 1
4: 1
5: 1
6: 1
7: 1
8: 1
Default:
0
[ 0- 1]00
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
MX-M182 SIMULATIONS 7-25
Main
Code numberSetting contents
0Toner near end is displayed
1Toner near end is not displayed
This simulasion is used to set the operating conditions for toner near end. The setting mode is switched by
[Density select] key.
The set value of the selected mode is displayed on the LCD display.
When the code number is entered and [START] key is pressed, the setting is switched.
<Toner near end display /No display>
<Setting of operations at toner end>
ContentsRemark
73Toner save setting display/non-display
Used to set Enable/Disable of the toner save setting in the system settings. If this setting is set to Enable (1),
the toner save setting appears in the system settings to allow setting.
Sim26-73 TS ENABLE
1:TS ENABLE
[ 0- 1]00
Display: Setting
0 : Disable
1 : Enable
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
74Total counter display change setting
Used to set whether the scanner counter value is added to the total counter display in the system settings.
Sim26-74 ADD COUNT
1:ADD SCAN CNT
[ 0- 1]00
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
3001Paper sensor status display
Used to display the list of paper sensor status on the LCD. An active sensor is highlighted.
The display items and corresponding sensors are shown below.
Sim30-1 SENSOR
POUT DPX PIN
MBEMP C1EMP C2EMP
C3EMP C4EMP C2PSS
C3PSS C4PSS
Default:
1
Default:
0
0 : Scan counter not added
1 : Scan counter added
Display : Corresponding sensor
POUT : Paper exit sensor
DPX : DUPLEX sensor
PIN : Paper entry sensor
MBEMP : Manual feed paper sensor
C1EMP : No. 1 tray paper sensor
C2EMP : No. 2 tray paper sensor
C3EMP : No. 3 tray paper sensor
C4EMP : No. 4 tray paper sensor
C2PSS : No. 2 tray paper feed senso
C3PSS : No. 3 tray paper feed senso
C4PSS : No. 4 tray paper feed senso
When a multi-stage cassette is not installed as an option, the corresponding sensor name is not displayed.
MX-M182 SIMULATIONS 7-26
Main
OC cover open/close sensor statusDocument sensor status
Used to check the operation of the document sensor.
When this simulation is executed, the status of the document sensor is displayed.
An active sensor display is highlighted.
Sim41-1 PD SENSOR
OCSW PD1 PD2
PD3 PD4 PD5
*For AB series, PD1-PD5; for inch series, PD1 - PD4.
When this simulation is executed, the detection level of the OC document size detection sensor is displayed.
(Real time display)
Place white paper of A3 or WLT on the document table and press [OK] key or [START] key with the OC
cover open.
When [START] key is pressed, "EXEC" is highlighted and the document detection level at that moment is
saved in the EEPROM. (The saved value is used as the reference for the following document size detection
control.)
Execution windowSensor position for AB seriesSensor position for Inch series
Sim41-2 PD SENSOR
OCS
1[128] 200
3[128] 200
5[128] 200
2[128] 200
4[128] 200
1
2
3
ContentsRemark
5 4
1
2
4 3
The values are displayed in the range of 0 - 255.
0 (Black) - 255 (White)
The value in [ ] indicates the adjustment threshold value. "EXEC" is highlighted during execution.
When this simulation is executed, the light receiving level of the document detection photo sensor is
displayed. (Real time display)
The values in parentheses of sensor 4 and 5 are the threshold values of adjustment at SIM41-04. Since
sensors 1 and 3 are not provide with the threshold value of detection at SIM41-04, "0" is always displayed.
Sim41-3 PD SENSOR
OCS
1[000] 200
3[000] 200
5[050] 200
2[000] 200
4[050] 200
04Detection level adjustment when the document size is settled (15 degrees - 20 degrees)
Set the OC cover to the document size settled state (15 degrees - 20 degrees), and press [OK] key.
1 Initial window
Sim41-4 20 SENSOR
PRESS OK KEY EXEC
2 After-execution window
Sim41-4 20 SENSOR
OCS
1[000] 163
3[001] 167
5[197] 179
2[000] 148
4[0C6] 180
The detection level under the document size settled state is saved in the EEPROM, and the value is
displayed in [ ].
*The document size settled state means the point when the open/close sensor (OCSW) is switched from
Used to clear the developing counter. When this simulation is executed, the confirmation window is
displayed to confirm to clear or not. To clear, press [OK] key or [START] key. Not to clear, press
[INTERRUPT] key or [CA] key to exit the simulation mode.
Sim42-1 COUNTER CLR
DEVELOPER COUNTER
CLEAR
ARE YOU SURE? EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
4301Fusing temperature setting 1
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1
and 2.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table
1 and 2.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-1 FUSER TMP 1
1:READY
2:NORMAL
3:THICK
170
165
180
170
ContentsRemark
Sim43-1 FUSER TMP 2
4:MOTORON
5:MOTOROFF
6:WEPEND
100
0
23
80
Window displaySetting itemSetting range
1: READYMain thermistor target temperature during standby150 - 230 *1
2: NORMALMain thermistor target temperature during plain paper
transmission *5150 - 230 *2
3: THICKMain thermistor target temperature during heavy paper
transmission150 - 230 *3
4: MOTORONMain thermistor temperature when starting main motor
preliminary rotation80 - 160 *4
5: MOTOROFFMain motor preliminary rotation end time (sec)0 - 90
6: WUPENDWarm-up compulsory termination time (sec)0 - 90
*1: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
*2: When the set value is increased by 1, the target temperature is increased by 10°C. (Refer to Table 2.)
*3: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
*4: When the set value is increased by 1, the target temperature is increased by 10°C. (Refer to Table 2.)
*5: The correction temperature applied to the current target temperature differs depending on the paper
size. For details, refer to SIM43-04.
Table 1:
Table 2:
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table 1.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-2 FUSER TMP 2
1:SUSPEND
2:RESUME
3:COOLDOWN
230
180
0
230
ContentsRemark
Window displaySetting itemSetting range
1: SUSPENDSub thermistor temperature when shifting to high temperature alarm150 - 230 *1
2: RESUMESub thermistor temperature when canceling high temperature alarm150 - 230 *2
3: COOLDOWNMain motor rotation time (sec) after completion of a JOB0 - 90
*1, *2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
Table 1:
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
03Fusing temperature setting 3
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1
and 2.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to
Ta b le 1 and 2.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-3 FUSER TMP 3
1:PREHEAT
2:WARMUP1
3:WARMUP2
110
100
150
110
Default:
SUSPEND: 230
RESUME: 180
COOLDOWN: 0
Window displaySetting itemSetting range
1: PREHEATMain thermistor target temperature during preliminary heating80 - 160 *1
2: WARMUP1When the initial temperature is below 120°C during warm-up150 - 230 *2
Main thermistor target temperature
3: WARMUP2When the initial temperature is above 120°C during warm-up150 - 230 *3
Main thermistor target temperature
*1: When the set value is increased by 1, the target temperature is increased by 10°C. (Refer to Table 2.)
*2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
*3: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
Table 1:
Table 2:
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
MX-M182 SIMULATIONS 7-29
Default:
PREHEAT: 110
WARMUP1: 160
WARMUP2: 150
Main
NO.012345678
Temperature (°C) -20 -15 -10 -50510 15 20
Setting mode
LOW Setting in normal temperature adjustment (190°C or below)
HIGH When the fusing temperature is 190°C or above
code
Sub
code
4304Fusing temperature setting 4
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 3.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table 3.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-4 FUSER TMP 4
1:TMPFIRST
2:TMPLAST
3:CNTFIRTS
5
-5
3
5
ContentsRemark
Sim43-4 FUSER TMP 4
4:CNTTYPE1
5:CNTTYPE2
6:CNTTYPE3
50
50
25
50
Window displaySetting itemSetting range
1: TMPFIRSTJOB initial correction temperature *3-20 - 20 *1
2: TMPLASTJOB latter-half correction temperature *4-20 - 20 *2
3: CNTFIRSTJOB initial temperature correction number of sheets0 - 255
4: CNTTYPE1JOB latter-half temperature correction number of sheets
(Paper size: A3/WLT)0 - 255
5: CNTTYPE2JOB latter-half temperature correction number of sheets
(Paper size: A4/LT)0 - 255
6: CNTTYPE3JOB latter-half temperature correction number of sheets
(Paper size: except A3/WLT/A4/LT)0 - 255
*1, *2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 3.)
*3: Correction temperature from starting a JOB to reaching the JOB initial temperature correction number
of sheets
*4: Correction temperature from the JOB initial temperature correction number of sheets to JOB end
Table 3:
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
4312Standby mode fusing fan rotation setting
When this simulation is executed, the currently set code number is displayed.
Select a mode to be changed with the arrow keys and enter a set value with numeric keys.
Enter the mode number to be selected with numeric keys and press [OK] key or [START] key. The set value
is saved in the EEPROM.
Sim43-12 FAN SPEED
1:LOW
2:HIGH
0
1
FAN rotation speed
0 : Low speed rotation
1 : High speed rotation
Used to change the paper feed timing of 21st sheet or later to A3 or WLT (depending on the destination
setting) when in multi copy/print of narrow width sheets.
When this simulation is executed, the current set number is displayed. Enter a code number and press
[START] key. The entered number is saved in the EEPROM and the machine returns to the sub code input
window.
Sim43-13 PICK INTVL
1:PICK INTVL
[ 0-1]00
Code: Setting
0: Disable (Default)
1: Enable
<Applicable paper>
1) Cassette paper feed: A4R,B5R,8-1/2"x14",8-1/2"x13",8-1/2"x11",A5,INV
2) Manual paper feed: A4R,B5R,8-1/2"x14",8-1/2"x13",8-1/2"x11",A5,INV,16KRÅ
*A5 is applicable to manual paper fed only in EX Japan AB series.
4401Enable/Disable setting of toner density control correction
Enable/Disable of toner density control correction is set.
When this simulation is executed, the list of the modes and the current set value are displayed on the LCD.
"Select an item to be changed with the cross key, and change the set value to the required value.
(1=ON [Enable], 0=OFF [Disable])"
When [OK] key or [START] key is pressed, the setting is saved to the EEPROM.
: Print ratio correction
: Life correction
: Drip supply
: Purge process
: Unconditional toner supply
0 : Disable
1 : Enable
<Descriptions of each correction>
Print ratio correction
In this correction, the toner supply interval is determined according to the print ratio to prevent against overtoner.
Note for corrections marked with
Since "Drip supply" and "Purge process" are simulations for analysis, do not set them to "1" [Enable].
If they are set to "1" [Enable], the toner density rises or falls abnormally and developer failure or toner
dispersion occurs.
If they are set to "1" [Enable] erroneously, developer must be replaced, and the inside of the machine and
the process unit must be cleaned.
Unconditional toner supply
When the developing unit and the drum unit are rotating, a small quantity of toner is consumed. For assuring
this operation, toner is supplied according to the rotation time of the developing unit.
16Toner density control data check and toner density correction quantity display
The output value of the ATC sensor is checked, and the toner density control correction quantity is displayed
on the LCD.
Sim44-16 TONER DISP
1:TONER DEN_LT
2:TONER DEN_ST
nnn
nnn
Name
TONER DEN_LT
TONER DEN_ST
:Display content
:Current ATC sensor value
:ATC reference value with life correction
quantity added
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
MX-M182 SIMULATIONS 7-31
Main
Display mode: Setting mode
NML F: Normal size paper (Front)
NML R: Normal size paper (Back)
SML F: Small size paper (Front)
SML R: Small size paper (Back)
BYPASS: Manual paper pass
Used to set the transfer current value. When this simulation is executed, the list of modes and the current set
value are displayed on the LCD.
Sim44-34 TC ADJ.
1:NML F
2:NML R
3:SML F
1/2 [ 9- 36]
22
21
22
22
Select a set item with the arrow keys and enter a set value with numeric keys. Press [OK] key or [START]
key, and the set value is saved in the EEPROM.
The setting range is 90µA - 360µA. The calculation formula is "Set value x 10 (µA)."
For example, in order to set the transfer current value to 200µA, set the adjustment value to "20."
*Small size paper means A4R (Letter R) width or less.
*When selecting the special size of tray, the normal size width setting is made.
4602Copy density adjustment (600dpi)
ContentsRemark
Default:
NML F: 22
NML R: 21
SML F: 22
Sim44-34 TC ADJ.
4:SML R
5:BYPASS
2/2 [ 9- 36]
21
22
22
SML R: 21
BYPASS: 22
Used to set the copy density for each mode.
Sim46-2 EXP. LEVEL
1:AE
2:TEXT
3:PHOTO 1
1/2 [ 1- 99]
50
50
50
50
Sim46-2 EXP. LEVEL
4:PHOTO 2
5:TEXT(TS)
6:AE(TS)
2/2 [ 1- 99]
50
50
50
50
Used to set the copy density for each mode.
When this simulation is executed, the list of the setting items and the current set value are displayed.
Select an item to be changed with [ ] key and [ ] key and enter the adjustment value with numeric keys.
The setting range is 1 - 99.
When [ ] key or [ ] key is pressed, the page is changed.
Enter the adjustment value with numeric keys and press [OK] key. The entered value is saved in the
EEPROM and the machine shifts to the copy window.
Sample copying can be performed during the simulation.
MX-M182 SIMULATIONS 7-32
Main
1 1.0(SHIFT)TEXT density 1 shift amount
2 1.0(GAMMA)TEXT density 1 gamma value
3 2.0(SHIFT)TEXT density 2 shift amount
4 2.0(GAMMA)TEXT density 2 gamma value
5 3.0(SHIFT)TEXT density 3 shift amount
6 3.0(GAMMA)TEXT density 3 gamma value
7 4.0(SHIFT)TEXT density 4 shift amount
8 4.0(GAMMA)TEXT density 4 gamma value
9 5.0(SHIFT)TEXT density 5 shift amount
10 5.0(GAMMA)TEXT density 5 gamma value
11 TS 1.0(SHIFT)TS TEXT density 1 shift amount
12 TS 1.0(GAMMA)TS TEXT density 1 gamma value
13 TS 2.0(SHIFT)TS TEXT density 2 shift amount
14 TS 2.0(GAMMA)TS TEXT density 2 gamma value
15 TS 3.0(SHIFT)TS TEXT density 3 shift amount
16 TS 3.0(GAMMA)TS TEXT density 3 gamma value
17 TS 4.0(SHIFT)TS TEXT density 4 shift amount
18 TS 4.0(GAMMA)TS TEXT density 4 gamma value
19 TS 5.0(SHIFT)TS TEXT density 5 shift amount
20 TS 5.0(GAMMA)TS TEXT density 5 gamma value
Used to adjust the shift amount and the slanting value for each density level (1-5) when the exposure model
is TEXT (including TS).
• For the shift amount, the gamma (gradation) is common. The whole sections are made brighter or darker.
When the shift amount is increased, the brightness is decreased. When the shift amount is decreased,
the brightness is increased.
• The slanting value changes the gamma (gradation).
When the set value is increased, the gamma is increased to provide a higher contrast. (Clear black and
white)
When the set value is decreased, the gamma is decreased to provide a lower contrast. (Higher gradation)
Select an adjustment mode with the arrow keys, and enter the set value with numeric keys.
The adjustment range is 1 - 99. When [ ] key or [ ] key is pressed, the page is changed.
The shift amount and the slanting value can be individually set for each of five levels of density for each of
TEXT/TS and TEXT. Therefore, there are 20 patterns of adjustment modes.
The value on the
example (50) is not
the default value.
50
50
50
50
Sim46-10 TEXT 600
13:TS 2.0(SHIFT)
14:TS 2.0(GAMMA)
15:TS 3.0(SHIFT)
5/7 [ 1- 99]
50
50
50
50
Select an item to be changed and set a desired adjustment value. Press [OK] key, and the machine shifts to
the copy window.
When [START] key is pressed at that time, copying is performed with the previous adjustment value and the
result can be checked.
1 ED 1.0(SHIFT)PHOTO (Error diffusion) density 1 shift amount
2 1.0(GAMMA)PHOTO (Error diffusion) density 1 gamma value
3 ED 2.0(SHIFT)PHOTO (Error diffusion) density 2 shift amount
4 ED 2.0(GAMMA)PHOTO (Error diffusion) density 2 gamma value
5 ED 3.0(SHIFT)PHOTO (Error diffusion) density 3 shift amount
6 ED 3.0(GAMMA)PHOTO (Error diffusion) density 3 gamma value
7 ED 4.0(SHIFT)PHOTO (Error diffusion) density 4 shift amount
8 ED 4.0(GAMMA)PHOTO (Error diffusion) density 4 gamma value
9 ED 5.0(SHIFT)PHOTO (Error diffusion) density 5 shift amount
10 ED 5.0(GAMMA)PHOTO (Error diffusion) density 5 gamma value
11 DI 1.0(SHIFT)PHOTO (Dither) density 1 shift amount
12 DI 1.0(GAMMA)PHOTO (Dither) density 1 gamma value
13 DI 2.0(SHIFT)PHOTO (Dither) density 2 shift amount
14 DI 2.0(GAMMA)PHOTO (Dither) density 2 gamma value
15 DI 3.0(SHIFT)PHOTO (Dither) density 3 shift amount
16 DI 3.0(GAMMA)PHOTO (Dither) density 3 gamma value
17 DI 4.0(SHIFT)PHOTO (Dither) density 4 shift amount
18 DI 4.0(GAMMA)PHOTO (Dither) density 4 gamma value
19 DI 5.0(SHIFT)PHOTO (Dither) density 5 shift amount
20 DI 5.0(GAMMA)HOTO (Dither) density 5 gamma value
Used to adjust the shift amount and the slanting value for each density level (1-5) when the exposure model
is PHOTO (error diffusion and dither).
• For the shift amount, the gamma (gradation) is common. The whole sections are made brighter or darker.
When the shift amount is increased, the brightness is decreased. When the shift amount is decreased,
the brightness is increased.
• The slanting value changes the gamma (gradation).
When the set value is increased, the gamma is increased to provide a higher contrast. (Clear black and
white)
When the set value is decreased, the gamma is decreased to provide a lower contrast. (Higher gradation)
Select an adjustment mode with the arrow keys, and enter the set value with numeric keys.
The adjustment range is 1 - 99. When [ ] key or [ ] key is pressed, the page is changed.
The shift amount and the slanting value can be individually set for each of five levels of density for each of
PHOTO mode (error diffusion and dither). Therefore, there are 20 patterns of adjustment modes.
The value on the
example (50) is not
the default value.
Sim46-11 PHOTO 600
1:ED 1.0(SHIFT)
2:ED 1.0(GAMMA)
3:ED 2.0(SHIFT)
1/7 [ 1- 99]
Sim46-11 PHOTO 600
50
4:ED 2.0(GAMMA)
50
5:ED 3.0(SHIFT)
50
6:ED 3.0(GAMMA)
50
2/7 [ 1- 99]
Sim46-11 PHOTO 600
13:DI 2.0(SHIFT)
14:DI 2.0(GAMMA)
15:DI 3.0(SHIFT)
5/7 [ 1- 99]
Select an item to be changed and set a desired adjustment value. Press [OK] key, and the machine shifts to
the copy window.
When [START] key is pressed at that time, copying is performed with the previous adjustment value and the
result can be checked.
Used to set the following three items. Select an item with the [ ] key or [ ] key and enter a set value with
numeric keys.
(1) : table setting
(2) : AE operation mode
(3) : PHOTO image process setting
When this simulation is executed, the current set code number of the above three modes are displayed.
Sim46-19 AE MODE
1:AE MODE
2:AE STOP
3:PHOTO
[ 1- 2]
(1) AE MODE( table setting)
Used to set the priority operation mode of the AE mode. When the image takes priority regardless of the
toner consumption, set to 1. When the toner consumption must be suppressed regardless of image quality,
set to 2.
*If this setting is changed, SIM 46-30 returns to the default.
(2) AE STOP (AE operation mode)
Used to set the area for automatic exposure correction in image process.
1
0
1
1
(3) PHOTO (PHOTO image process setting)
Used to set the image process when the PHOTO mode is selected. Selection is available in the following
two modes:
Used to set the exposure correction amount in the SPF/RSPF mode. (Since a slightly darker image is
outputted in the SPF/RSPF mode compares to the OC mode, the difference from the OC mode is corrected
with this simulation. When, therefore, the exposure in the OC mode is corrected, the SPF/RSPF exposure is
also changed accordingly.)
Enter a correction value with numeric keys and press [OK] key. The adjustment value is saved in the
EEPROM and the machine shifts to the adjustment copy window. Since this simulation is used to make up
for the exposure difference from the OC mode regardless of the exposure mode, the adjustment is fixed to
TEXT mode and the exposure mode cannot be changed. After completion of copying for check, the machine
returns to the setting window.
Sim46-20 SPF EXP.
1:SPF EXPOSURE
50
ContentsRemark
(Only when the
SPF/RSPF is
installed.)
Default:
50
[ 1- 99]
50
The adjustment value is in the range of 1 - 99.
Adjustment value (Image change) 99 (Dark) • • • 50 (Default) • • • 1 (Light)
29Image contrast adjustment (600dpi)
Used to adjust the image contrast for each mode.
When this simulation is executed, the current set value of each mode is displayed in two digits. (Default: 50)
Select an adjustment item (mode) with the arrow keys and enter a desired value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
Used to set the limit value in AE and AE (toner save) mode.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed.
(Adjustment item selection window)
Sim46-30 AE LIMIT
1:AE
2:AE(TS)
[ 0- 255]
Select an item to be changed with [ ] key and [ ] key and enter a desired value with numeric keys. The
entered value is saved to the EEPROM.
The adjustment value is in the range of 0 - 255.
*Note: When SIM26 - 06 (Destination setting) and SIM46 - 19 (Auto exposure mode) are changed, this
setting returns to the default accordingly.
31Image sharpness adjustment
Used to adjust sharpening/shading of image for each mode. When this simulation is executed, the selection
window of the adjustment items and the current set value are displayed.
(Adjustment item selection window)
Sim46-31 SHARPNESS
1:AE
2:TEXT
3:PHOTO 1
1/2 [ 0- 2]
ContentsRemark
Default:
196
Window display : Mode
0
0
0
1: AE : AE limit value
2: AE (TS) : AE (Toner save) limit value
Default:
AE: 1
TEXT: 1
PHOTO1: 1
PHOTO2: 1
Sim46-31 SHARPNESS
1
1
1
1
4:PHOTO 2
5:TEXT(TS)
6:AE(TS)
2/2 [ 0- 2]
1
1
1
1
TEXT (TS): 1
AE (TS): 1
The adjustment range is in the range of 0 - 2.
Select an adjustment item (mode) with the arrow keys and enter a desired value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
8 1/2×11
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
[BACK] key
Adjustment
item selection
window
[START] key
End of copy execution
[OK] key
MX-M182 SIMULATIONS 7-38
Copy start
window
[START] key
Copy execution
window
Main
code
Sub
code
ContentsRemark
4639FAX IMAGE adjustment
Used to adjust the resolution and the filer in the FAX mode.
The current set value of each resolution is displayed.
Sim46-39 FAX IMAGE
1:STD. 1
2:FINE 1
3:S-FINE 1
(1 - 7 ) X
1 - 7 input
Specify a resolution
[BACK] key
Sim46-39 FAX IMAGE
STD. X
(0 - 2 ) Y
[BACK] key
Sim46-39 FAX IMAGE
STD. Y
EXEC
* When "Interrupt" key is pressed on a window other than the operation window, the display shifts to the sub code input window.
[OK] key
to be set.
0 - 2 input
Specify the kind
[OK] key
of a filter to be set.
[OK] key
Self print operation is executed.
(The specified kind of the filter is used.)
The specified filter is used even
in the normal operation.
Sim46-39 FAX IMAGE
4:U-FINE 1
5:FINE/HT 1
6:S-FINE/HT 1
(1 - 7 ) X
Scanning operation
Sim46-39 FAX IMAGE
STD. Y
SCAN EXEC
4801Main/sub scanning magnification ratio adjustment
Used to adjust the magnification ratio in the main scanning (front/rear) direction and the sub scanning
direction.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed
(Adjustment item selection window)
Sim48-1 COPY MAG.
1:F-R
2:SCAN
[ 1- 99]
Display text array : Adjustment mode
50
1: F-R : Main scan direction magnification ratio (OC/SPF/RSPF)
50
2: SCAN : Sub scan direction magnification ratio (OC)
50
Sim46-39 FAX IMAGE
7:U-FINE/HT 1
(1 - 7 ) X
Printing operation
Sim46-39 FAX IMAGE
STD. Y
PRINT EXEC
Default:
F-R: 50
SCAN: 50
The adjustment value is in the range of 1 - 99.
When the adjustment value is increased by 1, the ratio is increased by 0.1%.
Select an adjustment item (mode) with the arrow keys and enter a desired value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
8 1/2×11
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
Adjustment
item selection
window
[START] key
[BACK] key
[OK] key
End of copy execution
Copy start
window
[START] key
Copy execution
window
MX-M182 SIMULATIONS 7-39
Main
code
Sub
code
ContentsRemark
4805SPF/RSPF mode sub scanning magnification ratio adjustment in copying
Used to adjust the sub scanning magnification ratio in the SPF/RSPF mode.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed.
(Adjustment item selection window)
Sim48-5 (R)SPF ZOOM
1:RSPF(SIDE1)
2:RSPF(SIDE2)
[ 1- 99]
50
50
50
Display text array : Adjustment mode
1: RSPF (SIDE1) : SPF/RSPF sub scan direction magnification
ratio adjustment on the front of document
2: RSPF (SIDE2) : RSPF sub scan direction magnification ratio
setting on the back of document
The adjustment value is in the range of 1 - 99. When the adjustment value is increased by 1, the ratio is
increased by 0.1%.
Select an adjustment item (mode) with the arrow keys and enter a desired value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
To adjust the sub scanning magnification ratio on the back of the document, shift the window to the copy
start window and select "Duplex
(Copy start window)
Ready to copy.
S
100%
8 1/2×11
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
Simplex" or "Duplex Duplex" mode with the [DUPLEX] key.
[BACK] key
Adjustment
item selection
window
[START] key
End of copy execution
[OK] key
*The exposure mode is fixed to "TEXT" with density 3, and cannot be changed.
* For the model without RSPF, the adjustment item of document back is not displayed.
08FAX magnification ratio adjustment (scan)
(Only when the
SPF/RSPF is
installed.)
Default:
RSPF(SIDE1): 50
RSPF(SIDE2): 50
Copy start
window
[START] key
Copy execution
window
Used to adjust and set the FAX document scan magnification ratio and scan and print the document.
Sim48-8 SCAN RATIO
1:OC
2:SPF
3:RSPF
( 1 - 3 ) X
Sim48-8 SCAN RATIO
MAIN SCANNING/OC
XXX
PRINT EXEC
Sim48-8 SCAN RATIO
OC
1:MAIN SCAN XXX
After input
1 - 3
[OK] key
2:SUB SCAN XXX
( 1 - 2 )
XX: Adjustment value of current state
YY: Inputted adjustment value
Sim48-8 SCAN RATIO
MAIN SCANNING/OC
XXX
SCAN EXEC
After input
1 - 2
[OK] key
Sim48-8 SCAN RATIO
MAIN SCANNING/OC
XXX
( 1 - 255 ) YYY
After input
1 - 255
[OK] key
Sim48-8 SCAN RATIO
MAIN SCANNING/OC
XXX
EXEC
09FAX magnification ratio adjustment (print)
Used to adjust and set the FAX print magnification ratio and scan and print the document.
XX: Adjustment value of current state
YY: Inputted adjustment value
After input
1 - 255
[OK] key
Sim48-9 PRI. RATIO
4:SUB SCAN/R XXX
( 1 - 4 )
Sim48-9 PRI. RATIO
MAIN SCAN
XXX
EXEC
Sim48-9 PRI. RATIO
MAIN SCAN
XXX
PRINT EXEC
Sim48-9 PRI. RATIO
MAIN SCAN
XXX
SCAN EXEC
MX-M182 SIMULATIONS 7-40
Main
(When entering the download
mode)
Connect the main unit and the
download PC with a USB cable,
and start downloading with the
maintenance tool.
When downloading is started, the
display is changed as follows:
(Receiving download data)
(Processing download data)
* Contents during processing the
download data
• FLASH ROM data erase
• Writing the received data into
the FLASH
• Sum check
(When downloading is completed)
(When an error occurs)
MCUPANEL
0xFF No processNo process
0x00 OKOK
0x03 Data receive error (Protocol error 2) Flash Rom write error (Program section)
0x04 Loader transfer errorFlash Rom write error (Common window data)
0x05 Flash Rom delete error (Boot)Flash Rom write error (Copy window data)
0x06 Flash Rom delete error (Program)Flash Rom write error (Scan window data)
0x07 Flash Rom write error (Boot)Flash Rom write error (Print window data)
0x08 Flash Rom write error (Program)Flash Rom write error (Fax window data)
0x09 Flash Rom LOCK error (Boot)
0x0A Flash Rom LOCK error (Program)Data writing start address illegal error
0x0B Sum check error (Loader)FROM size error
0x0C Sum check error (Boot)Destination error
0x0D Sum check error (Program)Download file structure error
0x0E Sum check error (EEPROM)
0x0F EEPROM read error
0x10 EEPROM write error Sum check error (Boot not-written)
0x11 EEPROM verify errorSum check error (Loader)
0x12 Download data length errorSum check error (After Boot writing)
0x17Sum check error (Print window data)
0x18Sum check error (Fax window data)
0x19 FAX communication errorPanel-MCU communication error
0x1A PANEL communication error
0x1B Download file error
code
Sub
code
4901Flash Rom program writing mode (MCU)
Used to download the programs and data sections of the main unit MCU board, the FAX board, and the
operation panel.
When this simulation is executed, the machine immediately shifts to the download mode and the following
display is shown.
ContentsRemark
Download Mode.
Download Data
Receiving.
Do not turn the
power off.
Processing finished.
Turn off the power.
ɢError.
MCU : -FAX : --
PNL : --
Used to display an error code at the error position in downloading of MCU/FAX/PANEL.
The error codes to be displayed are shown below.
MX-M182 SIMULATIONS 7-41
Main
FAX
0xFF No process0x44 FONT Flash write error
0x00 OK0x45 FONT Flash sum check error
0x01 Download impossible0x52 Registration data work sum check error
0x02 Total data size error0x56 Registration data format error
0x03 LOADER no file0x57 Registration data items insufficient error
0x04 DWLD no file0x58 Registration data items overlap error
0x05 BOOT no file0x61 BOOT data size error
0x06 MAIN no file0x62 BOOT work sum check error
0x07 FONT download impossible0x63 BOOT Flash erase error
0x08 Option FLASH connection error0x64 BOOT Flash write error
0x09 Option FLASH no match0x65 BOOT Flash sum check error
0x11 LOADER data size error 0x71 MAIN data size error
0x12 LOADER work sum check error0x72 MAIN work sum check error
0x21 BOOT data size error0x73 MAIN Flash erase error
0x22 BOOT work sum check error0x74 MAIN Flash write error
0x23 BOOT Flash erase error0x75 MAIN Flash sum check error
0x24 BOOT Flash write error0x81 FONT data size error
0x25 BOOT Flash sum check error0x82 FONT work sum check error
0x31 MAIN data size error0x83 FONT Flash erase error
0x32 MAIN work sum check error0x84 FONT Flash write error
0x33 MAIN Flash erase error0x85 FONT Flash sum check error
0x34 MAIN Flash write error0x91 DWLD data size error
0x35 MAIN Flash sum check error0x92 DWLD work sum check error
0x41 FONT data size error0x93 DWLD Flash erase error
0x42 FONT work sum check error0x94 DWLD Flash write error
0x43 FONT Flash erase error0x95 DWLD Flash sum check error
(When entering the download
mode)
(Processing download data)
* Contents during processing
the download data
• FLASH ROM data erase
• Writing the received data into
the FLASH
• Sum check
(When downloading is
completed)
(When an error occurs)
Downloaded Mode.
Do not turn the
power off.
code
4901
Sub
code
ContentsRemark
02Flash Rom program writing mode (NNB)
Used to write the program into NNB by using USB memory.
(Preliminary arrangement)
1. Save the NNB download file to the root directory of the USB memory.
2. Insert the USB memory into the USB port of the NNB board.
When this simulation is executed, the machine immediately shifts to the download mode and the following
display is shown.
Processing finished.
Turn off the power.
Note: The operations are enabled only when the MX-NB12 is active.
It takes 30 seconds for the MX-NB12 from turning ON the power to activating. When turning ON the
power, therefore, wait for 30 seconds before executing SIM49-02.
Once the process is started, never disconnect the USB memory until the end of the process.
It is allowed to save only one NNB download file (*.bm file) in the root directory of the USB memory.
ġĢġError.
MCU :
NNB : 0D
FAX :
MX-M182 SIMULATIONS 7-42
Main
Display text:Adjustment mode
1:TRAY1:Print start position (TRAY1)
2:TRAY2 (*):Print start position (TRAY2 - TRAY4)
3:MFT:Print start position (MULTI BYPASS)
4:DEN-A:Image lead edge void amount
5:RRC-A:Document scanning start position
6:DEN-B:Image rear edge void amount
code
Sub
code
5001Image lead edge adjustment
Used to adjust the following items related to the lead edge adjustment.
1.Print start position (Offset between output image and paper Adjusted for each tray.)
2.Image lead edge void (Margin on the output image lead edge)
3.Document scanning start position (Image scanning start position in the sub scanning direction)
When this simulation is executed, the selection window of the adjustment items and the set value are
displayed.
(Adjustment item selection window)
Sim50-1 LEAD EDGE
1:TRAY1
2:TRAY2
3:MFT
1/2 [ 1- 99]
50
50
50
50
Note 1: Items marked with (*) are displayed when TRAY2 and following options are not installed.
Note 2: When executing an adjustment copy from the manual paper feed tray, set the following paper.
AB series A3 paper
Inch series Double Letter paper
Note 3: When the adjustment value of the print start position adjustment is increased by 1, the ON timing of
the resist roller is delayed and the print result is shifted to the lead edge by 0.1mm.
Note 4: When the adjustment value of the image scanning start position is increased by 1, the scanning
start position is shifted to the home position by about 0.1mm, increasing the image loss amount.
Note 5: When the print start position (TRAY1) is changed, the print start positions (TRAY2 - TRAY4) and the
print start position (MULTI BYPASS) are also changed accordingly.
The adjustment value is in the range of 1 - 99.
Select an adjustment item (mode) with the arrow keys, and enter the set value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
8 1/2×11
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
[BACK] key
Adjustment
item selection
window
[START] key
End of copy execution
[OK] key
MX-M182 SIMULATIONS 7-43
Copy start
window
[START] key
Copy execution
window
Main
code
Sub
code
5001(Adjustment procedure)
(1) Set the print start position (1: TRAY1), the lead edge void amount (4: DEN - A), and the scanning start
position (5: RRC - A) to "1" and make a copy of 100%.
(2) Measure the image loss amount (R mm) of the scale.
Set [5:RRC - A] = 10xR(mm). (Example. Set 40.)
When the value of [5: RRC - A] is increased by 10, the image loss is decreased by1mm.
(3) Measure the distance (H mm) from the paper lead edge to the image print start position.
Set [1:TRAY1] = 10xH(mm). (Example: Set 50.)
When the value of [1:TRAY1] is increased by 10, the image lead edge shifts to the paper lead edge by
1mm.
(4) Set the lead edge void amount to B = 50(2.5mm).
When the value of [4:DEN - A] is increased by 10, the void amount is increased by about 1mm. (For 25
or less, the void amount is zero.)
[Example]
ContentsRemark
Copy output result
Distance between the
paper lead edge to the
image lead edge
H=5.0mm
Paper lead edge
Scale image loss
amount
R=4.0mm
06Copy lead edge position adjustment (SPF/RSPF)
Used to perform the image lead edge adjustment in the SPF/RSPF copy.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed.
(Adjustment item selection window)
Sim50-6 SPF EDGE
1:SIDE1
2:SIDE2
3:END EDGE
[ 1- 99]
50
50
50
50
Display text array : Adjustment mode
1: SIDE1 : Document (front) scan start position adjustment
2: SIDE2 : Document (back) scan start position adjustment
3: END EDGE : Document rear edge image loss adjustment
The adjustment value is in the range of 1 - 99. When the adjustment value of the document scanning start
position is increased by 1, the scanning timing is advanced, resulting in a smaller image loss.
Select an adjustment item (mode) with the arrow keys and enter a desired value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
×11
8 1/2
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
Adjustment
item selection
window
[START] key
End of copy execution
[BACK] key
[OK] key
Copy start
window
[START] key
Copy execution
window
(Only when the
SPF/RSPF is
installed.)
Default:
SIDE1: 50
SIDE2: 50
END EDGE: 50
MX-M182 SIMULATIONS 7-44
Main
Display text:Adjustment mode
1:TRAY1:Print center offset (TRAY1)
2:TRAY2 (*):Print center offset (TRAY2)
3:TRAY3 (*):Print center offset (TRAY3)
4:TRAY4 (*):Print center offset (TRAY4)
5:BYPASS:Print center offset (BYPASS)
6:DUPLEX (*):Print center offset (DUPLEX 2nd print surface)
code
Sub
code
5008FAX lead edge adjustment (scan)
Used to adjust and set the FAX document scan lead edge position and scan and print the document.
Sim50-8 SCAN EDGE
1:OC
2:SPF
3:RSPF
( 1 - 3 ) X
After input
1 - 3
[OK] key
Sim50-8 SCAN EDGE
OC
1:LEAD EDGE XX
2:LEFT EDGE XX
( 1 - 4 ) X
After input
1 - 4
[OK] key
Sim50-8 SCAN EDGE
LEAD EDGE/OC XX
( 43- 57 ) YY
XX: Adjustment value of current state
YY: Inputted adjustment value
After input
43 - 57
[OK] key
10Paper off-center adjustment
Used to adjust the output area (main scanning direction) of scanned image data on paper.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed.
Note 1: Items marked with (*) are displayed when TRAY2 and following options are not installed.
Note 2: When executing an adjustment copy from the manual paper feed (BYPASS) tray, set the following
paper according to the destination specification.
AB series A3 paper
Inch series Double Letter paper
The adjustment value is in the range of 1 - 99.
When the adjustment value is increased, the output image is shifted to the right. When the adjustment value
is increased by 1, the image is shifted to the right by about 0.1mm.
Select an adjustment item (mode) with the arrow keys, and enter the set value with numeric keys.
MX-M182 SIMULATIONS 7-45
Main
code
Sub
code
ContentsRemark
5010When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
8 1/2×11
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
Adjustment
item selection
window
[START] key
End of copy execution
[BACK] key
[OK] key
Copy start
window
[START] key
Copy execution
window
12Document off-center adjustment
Used to adjust the scanning start position in the main scanning direction of the document.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed.
(Note) 2:SPF(SIDE1) is available only for the model with the SPF/RSPF.
(Note) 3:SPF(SIDE2) is available only for the model with RSPF.
The adjustment value is in the range of 1 - 99.
When the adjustment value is increased, the document scanning position is shifted to the right and the
image is shifted to the left as a result.
When the adjustment value is increased by 1, the scanning area is shifted by 0.1mm.
Select an adjustment item (mode) with the arrow keys, and enter the set value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
×11
8 1/2
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
Adjustment
item selection
window
[START] key
End of copy execution
[BACK] key
[OK] key
Copy start
window
[START] key
Copy execution
window
Default:
OC: 50
SPF(SIDE1): 50
SPF(SIDE2): 50
MX-M182 SIMULATIONS 7-46
Main
code
Sub
code
ContentsRemark
5018Memory reverse position adjustment in duplex copy
Used to adjust the reverse point (scanning end position) on the reversed surface in duplex copy.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed
(Adjustment item selection window)
Sim50-18 DUP REV.
1:OC
2:SPF
[ 1- 99]
50
50
50
Display text array : Adjustment mode
1: OC : OC memory reverse output position
2: SPF : RSPF memory reverse output position
The adjustment value is in the range of 1 - 99.
Front surface print in S-D mode and even page print in D-S mode are reverse memory copy operations from
the document rear edge.
When, therefore, the print start position adjustment of the output image is required, adjust as follows:
The image in the reverse memory copy is printed from the scanning rear edge when the document scanning
direction is in the arrow direction as shown below.
If, therefore, the print lead edge is shifted, set the reference chart with the rear edge on the reference
position, and adjust the simulation set value with this simulation so that the print image lead edge matches.
Since printing is started at the print start position from the last memory image data to the head data, the end
data position saved in the memory is changed by changing the scanning end position with the simulation,
adjusting the image lead edge position.
(Execution is
allowed when
DUPLEX setting is
ON, and RSPF is
installed.)
Default:
OC: 50
SPF: 50
Document transport
direction
Scan directionScan rear edge
Scan lead edge
Scan end position
(Default: Void (1) is not scanned.)
Paper transport
direction
Print lead edge
Lead edge void (1)
Print start position
Rear edge void
Print rear edge
Select an adjustment item (mode) with the arrow keys, and enter the set value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
×11
8 1/2
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
Adjustment
item selection
window
[START] key
[BACK] key
[OK] key
End of copy execution
Copy start
window
[START] key
Copy execution
window
MX-M182 SIMULATIONS 7-47
Main
Display text:Adjustment mode
1:TRAY1:Resist amount in paper feed from TRAY1
2:TRAY2:Resist amount in paper feed from TRAY2 (*1)
3:TRAY3:Resist amount in paper feed from TRAY3 (*1)
4:TRAY4:Resist amount in paper feed from TRAY4 (*1)
5:BYPASS:Resist amount in paper feed from manual tray
6:RSPF(SIDE1):Resist amount on SPF/RSPF document surface (*1)
7:RSPF(SIDE2):resist amount on RSPF document back (*1)
8:RSPF A5:Document resist amount in A5 document back transport (*1)
9:DUPLEX:Resist amount in DUPLEX print (Second print surface) (*1)
10: PRE FEED:Pre-feed time of the manual feed tray paper feed. (*2)
code
Sub
code
5019Rear edge void adjustment in duplex copy
Used to adjust the rear edge void amount in duplex copy.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed.
(Adjustment item selection window)
Sim50-19 DUP R VOID
1:PRV(SIDE1)
2:PRV(SIDE2)
3:RRC-D
[ 1- 99]
50
50
50
50
Display text array : Adjustment mode
1: PRV (SIDE1) : Paper rear edge void amount (1st print surface)
2: PRV (SIDE2) : Paper rear edge void amount (2nd print surface)
3: RRC-D : Print start position (2nd print surface)
The adjustment value is in the range of 1 - 99.
When the adjustment value is increased by 1, the rear edge void amount is increased by about 0.1mm.
Select an adjustment item (mode) with the arrow keys, and enter the set value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying
(Copy start window)
Ready to copy.
S
100%
×11
8 1/2
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
ContentsRemark
(Execution is
allowed when
DUPLEX setting is
ON, and RSPF is
installed.)
Default:
PRV(SIDE1): 50
PRV(SIDE2): 50
RRC-D: 50
[BACK] key
Adjustment
item selection
window
[START] key
End of copy execution
[OK] key
Copy start
window
[START] key
Copy execution
window
5102Resist amount adjustment
Used to adjust the contact pressure (warp amount) of paper against the resist roller of the main unit resist
roller and the SPF/RSPF.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed.
5102(*1) Valid only when an option is installed. (If an option is not installed, it is not displayed on the adjustment
window.)
(*2) When heavy paper slips in manual feed copy, or when a paper jam occurs in thin paper copy, adjust this
set value to remove the problem.
•Heavy paper slips. Increase the set value.
• Thin paper jams. Decrease the set value.
The adjustment range is 1 - 99.
Select an adjustment item (mode) with the arrow keys, and enter the set value with numeric keys.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
8 1/2×11
Adjustment
item selection
window
[BACK] key
[OK] key
Copy start
window
(Copy execution window)
Copies in progress.
S
100%
8 1/2×11
[START] key
5308SPF/RSPF scanning position automatic adjustment
Used to adjust the SPF/RSPF stop position of the mirror unit in the SPF/RSPF copy.
The scanning position is basically determined by the automatic adjustment. It can be also adjusted
manually.
(Automatic adjustment window)
Sim53-8 SPF AUTO
PRESS OK KEY
EXEC 50
adjustment
OK
[OK] key or [START] Key
Sim53-8 SPF AUTO
EXEC
50
Key
Key
(Manual adjustment window)
Sub code input standby window
End of copy execution
Sim53-8 SPF AUTO
[START] Key
[START] key
Copy execution
window
An optional value can
be entered manually.
When [OK] key or [START] key
is pressed, the entered value
is saved in the EEPROM.
When [START] key is
50
pressed, the window
shifts to the sub code
input standby window.
When, however, [OK] key
is pressed, the window
does not shift.
Default:
50
adjustment
NG
Sim53-8 SPF AUTO
PRESS OK KEY
EXEC ERR
[OK] key or [START] Key
When the automatic adjustment result is NG,
"ERR" is displayed on the value display.
Enable/Disable of the LSU laser power correction during the operation is set.
When [START] key is pressed, the entered set value is saved and the machine enters the sub code input
standby mode.
Sim61-2 LASER PWR
1:LASER POWER
[ 0 - 1]
Code number : Mode
0 : Correction Enable
1
1 : Correction Disable
1
Note: Changing the setting does not affect the operation.
03HSYNC output check
When this simulation is executed, the polygon motor is rotated for 30sec together with the LEND signal.
"EXEC" (indicating execution) and "HSYNC" (HSYNC sensor detecting status) are displayed.
Every time when the HSYNC signal is detected, "HSYNC" display is highlighted for 100ms.
(Initial window)
Sim61-3 LSU CHECK
[OK] key or [START] key
ContentsRemark
Default:
0
(Execution window)
Sim61-3 LSU CHECK
HSYNC
PRESS OK KEY EXEC
6301Shading check
Used to display the detection level when the lamp of the white plate for shading correction is lighted.
When the simulation code is entered, the initial window is displayed to urge execution. Press [OK] key or
[START] key to start the simulation. The contents of the operations are as follows:
1. The mirror base unit is shifted to the white plate for shading correction.
2. The copy lamp is lighted.
3. "0" is displayed until the copy lamp light quantity is stabilized.
4. When the light quantity is stabilized, the level of 1 pixel on the CCD center which is not corrected is
displayed in hexadecimal.
*The white level is displayed for about 10sec. The data update cycle is about 1sec.
5. After passing 10sec, the machine returns to the sub code input window.
Sim63-1 SHADING
PRESS OK KEY EXEC
6401Self print
Used to perform printing of one page disregarding the optical system status. Also when the print command
is issued from the host, printing is performed.
When this simulation is executed, warm-up is performed and the ready lamp is lighted. (Since, however, the
optical system is invalid, initializing is not performed.)
There are following twenty-one self-printable patterns. Use numeric keys to select a pattern.
The selected pattern is displayed on 7-segment LED.
[OK] key or [START] key
EXEC
Sim63-1 SHADING
061
MX-M182 SIMULATIONS 7-50
Main
Sim66-1 FAX SOFT SW
ENTER FAX SOFT SW.#
( 3DIGITS ) XXX
Sim66-1 FAX SOFT SW
XXX is the input value of the soft SW number.
[OK] key[OK] key
No.XXX XXXXXXXX
USE # KEY 12345678
Sim66-1 FAX SOFT SW
No.XXX XXXXXXXX
To the initial window of SIM66-1
3sec later
[CA] key : Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric keys : Soft SW input
bit No. input
[OK] key : Settlement of the input value
[START] key : Settlement of the input value
[C] key : Input number clear for soft SW number input,
disable for the following windows
code
Sub
code
ContentsRemark
6401(*1) The grid pattern of about 1cm square is outputted.
Data are always made for A3 size. If printing is made on paper smaller than A3, the remaining data are
not outputted. (Images are not formed on the drum.)
(Initial window)
Ready to copy.
S
100%
8 1/2×11
[OK] Key or
[START] Key
Copies in progress.
100%
8 1/2×11
S
1
7SEG LED
After completion of printing one sheet
6510Key ACK time setting display/non-display setting
Used to set Enable/Disable of the key ACK time setting in the system settings. When this setting is set to
Enable (1), the key ACK time is displayed in the system settings, allowing setting.
Sim65-10 KEY TIME
1:KEY ACK TIME
[ 0- 1]11
Display: Setting
0: Disable
1: Enable
[CA] key: Exit the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
11Info lamp setting
Used to set the Info lamp brightness (PWM duty) and the kind of flashing.
Kind of flashing
1: Flashing
2: Flashing 10 times, and lighting thereafter.
3: Lighting
During this simulation, Info lamp is lighted to allow checking of the brightness.
[CA] key: Exit the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
6601FAX soft SW setting
Default:
1
Default:
Lamp brightness: 1
Kind of flashing: 1
Used to display the FAX-related soft SW on the LCD and set and change the soft SW setting with numeric
keys input.
U.S.A. 10110101
U.K. 10110100
Germany 00000100
France 0011110 1
Australia 00001001
China 00100110
Singapore 10011100
Malaysia 01101100
Hong Kong 01010000
Taiwan 11111110
Thailand 10101001
Middle east 1111110 1
India 01010011
Sweden 10100101
New Zealand 0111111 0
Spain 10100000
Portugal 10001011
Italy 01011001
Switzerland 10100110
Finland 0011110 0
Completion
of execution
(Highlighted
during execution)
code
Sub
code
6602FAX soft SW initializing
Used to clear the FAX-related soft SW values except for the line signal adjustment value and the machine
adjustment value and set them to the default values (which differ depending on the country code).
ContentsRemark
03FAX PWB memory check
Used to check read/write from/into the memory on the FAX PWB. The check result is displayed for each
memory.
*Interruption with [C] key
during execution cannot be made.
Numeric keys : Item selection
[OK] key : Settlement and execution of the input value
[START] key : Settlement of the input value
[BACK] key : Returns to the selection window.
[C] key : Disable
Execution error end
(Highlighted during execution)
Sim66-3 MEMOR CHK
DRAM
MEMORY CHECK RESULT
NG XXXXXXXX SUM
Execution normal end
(Highlighted during execution)
Sim66-3 MEMOR CHK
DRAM
MEMORY CHECK RESULT
OK
[BACK] key
NG XXXXXXXX SUM
NG XXXXXXXX A-BUS
NG XXXXXXXX DATA
NG XXXXXXXX D-BUS
NG XXXXXXXX ERASE
NG XXXXXXXX IO
[BACK] key
SIM66-3 initial window
MX-M182 SIMULATIONS 7-52
Main
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
SIGNAL SELECT
(1 - 35)
1:NO SIGNAL
2:33600bps(V34)
3:31200bps(V34)
(1 - 35) XX
After selection with numeric keys
[OK] key
[OK] key
[OK] key[BACK] key
33600bps(V34)
1:MAX
2:SOFT SW.
(1 - 2) X
33600bps(V34)
0dB
EXEC
33600bps(V34)
PRESS BACK TO STOP
EXEC
Sim66-4 SIGNAL OUT
34:DP MAKE
35:DP BREAK
(1 - 35) XX
After pressing
[OK] key
SIM66-4 initial window
[CA] key : Simulation cancel
[INTERRUPT] key : Sub code input window
[C] key : Input clear
key : Page select
Numeric keys : Number input and item selection
[OK] key : Input value settlement and execution
[START] key : Input value settlement
[BACK] key : Signal send stop
The window is switched with the up and down keys.
Input and switching the window are irrelevant.
Not highlighted with an input of a value.
The window is not switched, either.
When "1: NO SIGNAL" or "31: PSEUDO RNG" - "33: R.B. TONE NONE"
is selected, "0dB" and "SOFT SW" are not selected.
When one of these is selected, the second line is the signal name,
the third and fourth lines are empty, and the fifth line is EXEC display.
Used to send signals to the line and the machine speaker by setting the signal number. (Signal send is
continued until interruption is instructed by pressing RETURN key.) The signal send level is selected from
0db and the soft SW values. Since the level setting is not required for 1:NO SIGNAL and 31:PSEUDO RNG
- 33:R.B.TONE NONE, the selection menu does not appear. The signal send level is returned to the soft SW
set value before execution of the mode when completing the mode.
ContentsRemark
06Confidential pass code print
Used to print the confidential ID table (confidential box number, confidential box name, confidential pass
code).
07Image memory content print
Used to print all the image data (confidential receive contents, remote send images, and images which are
not sent yet) in the image memory of the FAX section. The printed images are remained in the memory after
printing.
MX-M182 SIMULATIONS 7-53
Main
code
Sub
code
6610Image memory contents clear
Used to clear all the image data (including confidential receive contents) in the image memory of the FAX
section. The management table is also cleared (initialized) at the same time.
Used to send the specified signal at the speed of 300bps by setting the signal number. (Signal send is
continued until interruption is instructed by pressing RETURN key.) The signal send level is selected from
0db and soft switch set values. The signal send level is returned to the sot SW set value before execution of
the mode after completion of the mode.
[OK] key
After pressing
[OK] key,
during execution
ContentsRemark
Without prints
Sim66-10 IMAGE CLR
CLEARED
[BACK] key
Simulation code input window
Sim66-10 IMAGE CLR
CLEAR IMAGE MEM.
EXEC
Completion of execution
(Highlighted during execution)
With prints
Sim66-10 IMAGE CLR
CLEARED IMAGE MEM.
DO POWER OFF
Power source OFF/ON
Completion
of execution
(Highlighted
during execution)
Sim66-11 300bps SIG.
SIGNAL LEVEL
1:MAX
2:SOFT SW.
( 1 - 2 ) X
After selection with numeric keys
[OK] key
Sim66-11 300bps SIG.
1:NO SIG. 4:00000
2: 11111 5 :010101
3: 11110 6: 00001
( 1 - 6 ) X
After selection
with numeric keys
[OK] key
[CA] key : Simulation cancel
[INTERRUPT] key : Sub code input window
[C] key : Input clear
keys : Page switch
Numeric keys : Item selection
[OK] key : Input value settlement and execution
[START] key : Input value settlement
[BACK] key : Signal send stop
Sim66-11 300bps SIG.
NO SIGNAL
EXEC
After pressing [OK] key,
during execution
[OK] key
Sim66-11 300bps SIG.
OUTPUTING SIGNAL
PRESS BACK TO STOP
EXEC
[BACK] key
SIM66-11 initial window
MX-M182 SIMULATIONS 7-54
Main
code
Sub
code
6613Dial number registration
Used to perform send test and adjustments of the dial pulse and the DTMF signal.
Perform send test of the dial pulse and the DTMF signal, and perform adjustments of the make time of the
dial pulse and adjustments of the send level of the DTMF signal.
Completion of execution
(Highlighted during execution)
SIM66-13 initial window
After selection
with numeric key
Sim66-13 DIAL TEST
1.NormalMode
2.HandsetMode
( 1-2 ) X
When the soft SW and the SIM DTMF
sound speaker are selected, "Normal"
and "handset" are selected. In another
case, this menu is not displayed.
The default is set to "1590."
Dial input (0 - 9, *, #)
When the value is great, scroll to the left.
When [C] is pressed, all are cleared.
After selection
with numeric key
[OK] key
[INTERRUPT] key : Sub code input window
[C] key : Input clear
Numeric key : Input of time and dial number
and selection of an item
[OK] key : Settlement and execution of an input
[START] key : Settlement of an input
[BACK] key : Returns to the selection window
XXXXXXXX : Input dial
Sim66-13 DIAL TEST
SELECT HIGH LEVEL
1:DEFAULT
2:SOFT SW. Y
( 1-2 ) X
[CA] key : Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric key : Item selection
[OK] key : Settlement and execution
[START] key : Input value settlement and execution
[BACK] key : Returns to the selection window.
keys : Page switch
[C] key : Disable
Completion of
execution
(Highlighted during
execution)
Sim66-24 FAST CLEAR
INITIALIZED
1sec later
Simulation code input window
Used to display the change contents regardless of the soft SW setting when the status of the polarity
inversion relay, the handset hook switch, or the external telephone hook switch is changed. The display of
the changed status is remained until the interruption command is made by pressing RETURN key.
Sim66-30 TEL STAT.
EXEC
After pressing
[OK] key,
during
execution
[OK] key
Sim66-30 TEL STAT.
HS2 :XXX HS1 :XXX
RHS :XXX EXHS :XXX
PRESS BACK TO STOP
EXEC
The following bit 0/1 is alternatively switched. At the same time, the target signal name is highlighted.
Sim66-31 TEL OUTPUT
1:CION 2:150VON
3:EC 4:S
(1 - 5) X
Sim66-31 TEL OUTPUT
1:CION 5:MSR
EXEC
Sim66-31 TEL OUTPUT
1:CION 5:MSR
PRESS BACK TO STOP
EXEC
After selection
with numeric keys
[OK] key
After pressing [OK] key,
during execution
[OK] key
[BACK] key
ContentsRemark
[CA] key : Simulation cancel
Sim66-31 TEL OUTPUT
5:MSR
(1 - 5) X
Selection of two or more items can be made.
(The selected numbers are highlighted.)
Though numeric keys is pressed in the sequence
of "1 and 5" or "5 and 1," the display is made
in the sequence of the normal order
(1 and 5) when OK key is pressed.
[INTERRUPT] key : Sub code input window
Numeric keys : Item selection
[OK] key : Input value settlement and execution
[START] key : Input value settlement and execution
[BACK] key : Returns to the selection window
keys : Page switch
[C] key : Input value clear. ON when highlighted.
32Receive data check
Used to check receive data from the line and judge whether the following receive data and the judged data
number accord together or not. If they accord, "OK" is notified. If not, "NG" is notified. Judgment is made
from the receive start data and the data must be accorded continuously.
pressing [OK] key, the
window shifts to the
next one.
[OK] key
Sim66-34 COMM. TIME
COMM. TIME:
xxx:xx:xx:xxxms
Simulation code
input window
[BACK] key
37Speaker sound volume adjustment
Used to adjust the speaker sound volume.
During execution of this simulation, the following test sound is sent to the line and the speaker.
The send level to the line is set to the soft SW setting value.
The speaker sound volume can be adjusted by the operation.
The type of sound can be selected among the following:
6.DTMF send sound
For each type of sound, the sound volume can be selected among the following:
No sound, Small, Medium, Large
The set value is written into each soft SW.
MX-M182 SIMULATIONS 7-58
Main
Type of soundSoft SW number
1. Sound volume of call soundSW 53-3 - 4
Sound volume of call sound (Low)SW131-5 - 8
Sound volume of call sound (Medium)SW132-1 - 4
Sound volume of call sound (High)SW132-5 - 8
2. Line monitor speaker sound volumeSW 52-5 - 6
Line monitor speaker sound volume (Low)SW127-1 - 4
Line monitor speaker sound volume (Medium)SW127-5 - 8
Line monitor speaker sound volume (High)SW128-1 - 4
Scan end speaker sound volume (Low)SW124-1 - 4
Scan end speaker sound volume (Medium)SW124-5 - 8
Scan end speaker sound volume (High)SW125-1 - 4
5. Communication end speaker sound volumeSW 52-7 - 8
Communication end speaker sound volume (Low)SW128-5 - 8
Communication end speaker sound volume (Medium)SW129-1 - 4
Communication end speaker sound volume (High)SW129-5 - 8
Used to set an limitation on the print data reception speed when the USB transfer speed is at full speed.
Sim67-50 USB SPEED
1:FULL SPEED
* When images are disturbed in printing through USB, change the setting and try again.
[CA] key: Exits from the simulation mode.
[INTERRUPT] key: Shifts to the sub code entry window.
2
[ 1- 4]
2
Fast
Slow
Display : Setting
1 : FAST
2 : NORMAL 1
3 : NORMAL 2
4 : SAFE
MX-M182 SIMULATIONS 7-60
Default:
3
[8] TROUBLE CODE LIST
1.Trouble code list
Main code Sub
code
CE00General network errors
01NIC error
02Server not found
03Server down
04FTP account error
05FTP directory error
06Email address error
09Email over size limit
11Scanner memory shortage
18RTC battery error
64Toner supply abnormality
70Improper cartridge (destination error, life cycle
error)
Identification error
Model error
Type error
Destination error
Data abnormality
Misc error
74CRUM chip communication error
F502Copy lamp lighting abnormality
F600FAX board communication trouble
10FAX board trouble
80FAX board communication trouble (Protocol)
81FAX board communication trouble (Parity)
82FAX board communication trouble (Overrun)
84FAX board communication trouble (Framing)
88FAX board communication trouble (Time out)
99Machine - FAX language error
F900NNB communication trouble
H200Thermistor open (MAIN)
01Thermistor open (SUB)
H300Heat roller high temperature detection (MAIN)
01Heat roller high temperature detection (SUB)
H400Heat roller low temperature detection
H5015 continuous POUT not-reached error
L100Scanner feed trouble
L300Scanner return trouble
L401Main motor lock detection
11Shifter motor trouble
32PSFAN lock detection
L610Polygon motor lock detection
L801No full wave signal
U103FAX board battery error
U204EEPROM read/write error (serial communication
error)
11Counter check sum error (EEPROM)
Content
Main codeSub
code
U900Panel board communication trouble
80Panel board communication trouble (Protocol)
81Panel board communication trouble (Parity)
82Panel board communication trouble (Overrun)
84Panel board communication trouble (Framing)
88Panel board communication trouble (Time out)
99Panel language error
CH ONNone Door open
CH BlinkNone Developing cartridge not installed
Content
2.Details of trouble codes
Main
Sub
code
code
CE00 ContentGeneral network errors
DetailOther network errors
Check
and
remedy
01 ContentNIC error
DetailAn error occurs in the network protocol stack
Check
and
remedy
02 ContentServer not found
DetailThe specified sever is not found.
Check
and
remedy
03 ContentServer down
DetailThe specified server is not active.
Check
and
remedy
04 ContentFTP account error
DetailAn account error occurs when logging in the
Check
and
remedy
Turn OFF and ON the power. Consult the
network administrator to check the network
server status. If the error still remains, turn
OFF the power of the machine, and
immediately contact the sales agent.
level.
Turn OFF and ON the power. Consult the
network administrator to check the network
server status. If the error still remains, turn
OFF the power of the machine, and
immediately contact the sales agent.
Since connection to the server is not
established, the scan data cannot be sent.
Check to confirm that the SMTP server setting
and the destination registration of file server
send scan are properly made. For the setting
procedure of the SMTP server, refer to
"Various servers setting." For the changing
procedure of the destination of file server send
scan, refer to "How to change or delete the
registered destinations." For the input items of
each setting, refer to the help menu of the Web
screen.
Since the server is busy or the line is busy,
scan data cannot be set. Wait for a while, and
try sending again.
FTP server.
Since connection to the server is not
established, the scan data cannot be sent.
Check to confirm that the destination
registration of file server send scan is properly
made. For the changing procedure of the
destination of file server send scan, refer to
"How to change or delete the registered
destinations." For the input items of each
setting, refer to the help menu of the Web
screen.
Details of trouble
MX-M182 TROUBLE CODE LIST 8-1
Main
Sub
code
code
CE05 ContentFTP directory error
DetailThe designation of the directory in the FTP
Check
and
remedy
06 ContentEmail address error
DetailImproper email address
Check
and
remedy
09 ContentEmail over size limit
DetailThe size of an email to be sent exceeds the
Check
and
remedy
11 ContentScanner memory shortage
DetailMemory shortage in scanner process of MX-
Check
and
remedy
12 ContentLDAP number over
DetailThe number of LDAP exceeds the
Check
and
remedy
18 ContentRTC battery error
DetailThe battery for RTC is low.
Check
and
remedy
E701 ContentDuplex model memory error/ Image data error
Detail1. The memory capacity for the duplex model
Cause1. The memory capacity on the MCU PWB is
Check
and
remedy
server is improper.
Since the directory of the FTP server
registered as the destination of file server send
scan is improper, the scan data cannot be sent.
Check to confirm that the registration of the
destination is correct.
Since the email address registered as the
destination of the email send scan is improper,
scan data cannot be sent. Check to confirm
that the registered destination information is
correct.
limit.
The size of the scan data exceeds the upper
limit of the file size set on the Web screen.
Reduce the number of sheets of documents or
change the upper limit value in "Send data
upper limit" of the Web screen.
NB12.
The memory becomes full during scanning
documents Reduce the number of sheets of
documents, or change the resolution and the
color mode in order to reduce the file size of
the scan data, then retry sending again.
specification.
The number of destinations which are the
targets of the global address search exceeds
the max. number. Use a longer set of
characters for search to narrow the area of
search.
Replace the battery for RTC.
machine is wrong. Insufficient memory
capacity.
2. Duplex setting is set for a single surface
model.
wrong.
2. Setting for a single surface model is wrong.
1. Use SIM26-39 to check to confirm that the
memory capacity is 128MB. If it is not
128MB, replace the MCU PWB.
CauseImproper connection of the CCD unit flat cable
Check
and
remedy
11 ContentShading trouble (White correction)
DetailThe CCD white scan level is abnormal when
CauseImproper connection of the CCD unit flat cable
Check
and
remedy
16 ContentAbnormal laser output
DetailWhen the laser output is stopped, HSYNC is
CauseLaser abnormality
Check
and
remedy
91 ContentDecode error (FAX print)
DetailWhen image data sent from the FAX board to
CauseConnector connection trouble
Check
and
remedy
detected in a certain cycle. (Always OFF or
always ON)
disconnection
Polygon motor rotation abnormality
Laser beams are not generated.
MCU PWB abnormality.
Check connection of the LSU connector.
Execute SIM 61-03 to check the LSU
operations.
Check that the polygon motor rotates normally.
Replace the LSU unit.
Replace the MCU PWB.
USB cable trouble
Replace the MCU PWB.
Replace the USB cable.
the shading.
CCD unit abnormality
MCU PWB abnormality.
Check connection of the CCD unit flat cable.
Check the CCD unit.
the shading.
Dirt on the mirror, the lens, and the reference
white plate
Copy lamp lighting abnormality
CCD unit abnormality
MCU PWB abnormality
(When occurred in the SPF scan position.)
Improper installation of the mirror unit
Clean the mirror, the lens, and the reference
white plate.
Check lighting and the light quantity of the copy
lamp (SIM05-03).
Check the CCD unit.
Check the MCU PWB.
detected.
MCU PWB abnormality.
Replace the LSU.
Replace the MCU PWB.
the machine are judged as decode error:
MCU PWB abnormality
Turn OFF/ON the power.
Connect the connector again.
Replace the MCU PWB.
Details of trouble
MX-M182 TROUBLE CODE LIST 8-2
Main
Sub
code
code
E793 ContentData communication error (FAX scan)
DetailWhen data transmission from the machine to
CauseConnector connection trouble
Check
and
remedy
F240 ContentATC sensor abnormality
DetailATC sensor value abnormality
CauseConnector connection trouble
Check
and
remedy
64 ContentToner supply abnormality
DetailWhen toner near end is detected with the toner
CauseATC sensor abnormality
Check
and
remedy
F270 Content•Improper cartridge (Destination error, life cycle
Detail•The destination of the machine differs from
Check the harness and the connector between
the CCD unit and the MCU PWB.
When the copy lamp does not light up.
Check the harness and the connector between
the copy lamp unit and the MCU PWB.
Replace the copy lamp unit.
Replace the MCU PWB.
FAX .
Check connection of the FAX board.
Replace the FAX board.
abnormality.
Replace the FAX board.
between the MCU and the FAX board.
Garbled data.
Check connection of the FAX board.
Replace the FAX board.
Reset the machine (Power OFF/ON).
between the MCU and the FAX board.
Garbled data.
Check connection of the FAX board.
Replace the FAX board.
Reset the machine (Power OFF/ON).
between the MCU and the FAX board.
Garbled data
Check connection of the FAX board.
Replace the FAX board.
Reset the machine. (Power OFF/ON).
between the MCU and the FAX board.
Garbled data.
Check connection of the FAX board.
Replace the FAX board.
Reset the machine (Power OFF/ON).
Details of trouble
MX-M182 TROUBLE CODE LIST 8-3
Main
Sub
code
code
F688 ContentFAX board communication trouble (Time out).
DetailFAX board communication error.
CauseThere is no respond command from the FAX
Check
and
remedy
99 ContentMachine - FAX language error.
DetailDiscrepancy of the destination of the machine
CauseThe destination of the machine differs from that
Check
and
remedy
F900 ContentMX-NB12 board communication trouble.
DetailMX-NB12 print data reception error.
CausePrint data cannot be received from the MX-
Check
and
remedy
H200 ContentThermistor open (MAIN)
DetailThe thermistor is open.
CauseThermistor abnormality
Check
and
remedy
01 ContentThermistor open (SUB)
DetailThe sub thermistor is open.
CauseSub thermistor abnormality
Check
and
remedy
for 30sec or more.
Check connection of the FAX board.
Replace the FAX board.
Reset the machine (Power OFF/ON).
and the FAX board.
of the FAX board.
When installing to the machine that can install
only MX-FX13.
Change the destination setting with SIM26-6.
Replace the FAX board with one which.
conforms to the destination of the machine.
NB12 for 3 min or more.
Reset the machine (Power OFF/ON).
The fusing unit is not installed.
Control PWB abnormality
Fusing section connector disconnection
The fusing unit is not installed.
Check the harness and the connector between
the thermistor and the PWB.
Cancel the trouble with SIM 14.
The fusing unit is not installed.
Heater lamp abnormality
Thermostat abnormality
Main PWB abnormality
Use SIM 5-02 to check the heater lamp blinking
operation.
When normally lighting.
Check the sub thermistor and its harness.
Check the sub thermistor input circuit on the
MAIN PWB.
When not normally lighting.
Check the lamp control circuit on the MCU
PWB.
Cancel the trouble with SIM 14.
Details of trouble
Main
Sub
code
code
H300 ContentHeat roller high temperature detection (MAIN)
DetailThe fusing temperature exceeds 245C°.
CauseThermistor abnormality
Check
and
remedy
01 ContentHeat roller high temperature detection (SUB)
DetailThe fusing temperature exceeds 245°C.
CauseSub thermistor abnormality
Check
and
remedy
H400 ContentHeat roller low temperature detection
DetailWhen the fusing temperature is 150C° or less
CauseThermistor abnormality
Check
and
remedy
Control PWB abnormality
Fusing section connector disconnection.
Use SIM 5-02 to check the heater lamp blinking
operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the control
PWB.
When the lamp keeps ON.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Cancel the trouble with SIM 14.
Heater lamp abnormality
Thermostat abnormality
Main PWB abnormality
Use SIM 5-02 to check the heater lamp blinking
operation.
When normally lighting.
Check the sub thermistor and its harness.
Check the sub thermistor input circuit on the
MAIN PWB.
When not normally lighting.
Check the lamp control circuit on the MCU
PWB.
Cancel the trouble with SIM 14.
in 55 sec from starting warming-up.
When the warm-up complete temperature is
not reached in 30 sec from reaching 150C°.
When the fusing temperature is less than
100C° in 20 sec from the ready state.
When the fusing temperature is less than 80C°
for more than 300ms in the ready state or in
printing.
When the fusing temperature is less than 80C°
for more than 300ms in the standby mode at a
low temperature.
Heater lamp abnormality
Thermostat abnormality
Control PWB abnormality
Use SIM 5-02 to check the heater lamp blinking
operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the control
PWB.
When the lamp does not light up.
Check for disconnection of the heater lamp and
the thermostat. Check the interlock switch.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Cancel the trouble with SIM 14.
Details of trouble
MX-M182 TROUBLE CODE LIST 8-4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.