Sharp FU-40SE-K Operating Manual

R
FU-40SE-K
AIR PURIFIER OPERATION MANUAL
Tabletop / wall-mounting type
ENGLISH

FEATURES

Cluster Ion Control
The unit controls the ratio of minus cluster ions and plus cluster ions depending on the condition of the room.
• Clean mode
Approximately the same amount of plus and minus cluster ions are discharged. This mode is effective f or reducing floating mold and household odors in the air.
• Refresh mode
It is said that plenty of minus ions exist in places such as waterfalls or forests. In this operation mode, minus ions will be released in an increased rate, in order to bring the room air close to this condition.

CONTENTS

SAFETY PRECAUTIONS........................ E-2
•CAUTIONS CONCERNING THE USAGE
OF THIS PRODUCT ....................................E-3
•CAUTIONS WHEN MOUNTING THIS
PRODUCT ON A WALL ...............................E-3
•CAUTIONS CONCERNING
THE INSTALLATION ....................................E-3
NAMES OF PARTS ................................. E-4
•ACCESSORIES ...........................................E-5
•AUTO cluster ion mode
The unit will switch between the Clean mode and Refresh mode automatically depending on the amount of pollution in the air detected by dust and odor sensor.
HEPA Filter
• High-efficiency dust collection
Stamina-power carbon
Powerful deodorization by large particles of columnar charcoal.

FOR UNDERST ANDING THE PRODUCT

Some of the odor ingredients adsorbed by the filters become sepa­rated and are discharged through the exhaust port as odor. Depending on the usage environment, this odour may become strong after several months and the exhaust port may smell. In this case, purchase an exchange filter FZ-40SEF of the option goods, and replace the filters.
This equipment complies with the requirements of Directives 89/ 336/EEC and 73/23/EEC as amended by 93/68/EEC.
INSTALLATION .......................................E-6
WHEN USING THE UNIT ON A TABLETOP ..
•WHEN WALL MOUNTING THE UNIT..........E-7
PREPARATION........................................E-8
• INST ALLING THE FIL TERS.........................E-8
• INSERTING BATTERIES
IN THE REMOTE CONTROL ......................E-8
• USING THE REMOTE CONTROL...............E-9
OPERATION .......................................... E-10
• MAIN UNIT OPERATION .......................... E-10
• REMOTE CONTROL OPERATION ...........E-11
CARE AND MAINTENANCE................. E-12
• MAIN UNIT................................................ E-12
• FILTERS.................................................... E-12
• GUIDE FOR LIFE OF FILTERS ................ E-13
TROUBLE SHOOTING.......................... E-14
SPECIFICATIONS ................................. E-14
Thank you for purchasing the SHARP FU-40SE. Please read this manual carefully for the correct usage. Before using this product, be sure to read “Safety precautions.” After reading this manual, retain it in a conven­ient location for future reference. This product is for household use only.
E-6
E-1

SAFETY PRECAUTIONS

• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loose.
Electrical shock, short circuit and/or fire may occur as a result.
• Do not damage, break, coat, forcefull y bend, pull, twist, b undle, pinch or place heavy objects on the power cord.
If the power cord is damaged, fire and/or electrical shock may occur as a result.
• Use AC 220~240V only.
• Do not modify . Repair and disassembly of this product are to be performed by authorized service personnel only.
Fire, electrical shock and/or bodily injury may occur if not. For repair, contact your dealer or the nearest Sharp Service Center.
•Periodically remove dust from the power plug
Accumulated dust on the power plug may cause bad insulation from humidity, etc. Fire and/or electrical shock may occur as a result.
•When cleaning the unit, be sure to remove the power plug from the wall outlet.
In addition, never handle the power plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
• Do not use the unit where there are oil ingredients such as cooking oil, etc., in the air.
Cracking of the unit surface may occur as a result.
• Do not wipe the unit with benzene or paint thinner. Also, do not spray insecticides on the unit.
Cracking, electrical shock and/or fire may occur as a result.
• Do not operate the unit when using indoor smoke-generating insecticides.
Chemical ingredients may accumulate within the unit and then discharge from the exhaust port when the unit operates. Discharge of such chemicals may be unhealthy to your body.
• Do not allow the unit to intake flammable gases, sparks from lit cigarettes, incense, etc.
The unit may ignite as a result.
• Do not use the unit where it is humid, such as in a bathroom, etc., or where the unit may get wet.
Electrical shock and/or malfunction may occur as a result.
• Do not insert fingers or foreign objects into the intake or exhaust ports.
Electrical shock and/or malfunction may occur as a result.
•When mounting to a wall, select a sturdy wall or studding.
The unit may fall if not.
•When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
•Ventilate when using the unit along with a heating appliance.
Carbon monoxide poisoning may occur as a result.
• Remove the power plug when not using the unit.
• If the supply cord is damaged, it m ust be replaced by the manufacturer or its service a gent or similarly qualified person in order to avoid a hazard.
• The batteries must be disposed of safely.
E-2
CAUTIONS CONCERNING THE USAGE OF THIS PRODUCT
• Do not block the intake and exhaust ports.
• Do not use the unit near or on hot objects, such as a stov e, etc. Also , do not use the unit where it ma y come into contact with steam.
• Do not use the unit on its side.
Deformation, malfunction and/or overheating of the motor may occur as a result.
• Do not install when there is generation of lampblack, such as in a kitchen, etc.
• Do not use detergent when cleaning the unit.
The unit surface may become damaged or cracked. In addition, the sensors may malfunction as a result.
•When transporting the unit, always hold the handle on the back of the unit.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in bodily injury.
CAUTIONS WHEN MOUNTING THIS PRODUCT ON A WALL
•Never mount the unit to a thin wall or plasterboard of insufficient strength. The unit may fall as a result.
•When mounting the unit to a wall, remove the front panel and hold the main unit.
Holding the front panel may cause it to become detached, thus dropping the unit and resulting in bodily injury.
• Do not install when there is generation of lampblack, such as in a kitchen, etc.
The unit surface may crack or the sensors may malfunction as a result.
CAUTIONS CONCERNING THE INSTALLATION
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS
• Locations where there are inverter lighting equipment or electronic spontaneous lighting equip­ment
The remote control may become inoperative. In this case, move away from such lighting equipment or change direction.
• Location exposed to direct sunlight
The unit may not received signals from the remote control
INSTALLATION
• Leave at least 2m of space from televisions and radios
Electrical interference may occur if not.
• Leave at least 60cm of space from the wall
The motor may overheat, causing malfunction if not.
•Avoid a location where sensors are exposed to direct wind
The unit may not operate properly.
•Avoid a location where curtains, etc., come into contact with the intake or exhaust port.
Curtains, etc., may become dirty or malfunction may occur as a result.
EFFECTIVE USAGE
• Place on a stable surface with sufficient air circulation
• Near smoking area
Air pollution is detected quickly.
ABOUT THE FIL TER
• Do not wash or reuse Apatite HEPA filter and deodorization filter.
• Small dust particles and odors such as tobacco smoke rise and accumulate at the top of the room.
• Large dust such as pollen and house dust accumulate at the bottom of the room.
• The wall, etc., behind the exhaust port may become dirty as time passes. When using the unit for extensive period in the same location, use a vinyl sheet, etc., to pre v ent the wall from becoming dirty . In addition, periodically clean the wall, etc.
E-3

NAMES OF PARTS

MAIN UNIT DISPLA Y

It can not remove the noxious substances (carbon
*
monoxide etc.) from cigarette smoke.
Filter timer lamp
AUTO operation lamp
Silent
Remote control receiver
Odor sensor
(Detects odors such as tobacco smoke, incense, pets, cosmetics,
etc.)

EXPLODED DIAGRAM

Tobacco smoke mode operation lamp
*
Fan level lamps
High
Median
Dust sensor
(Detects dust, smoke, pollen, house dust, etc.)
Pollen mode operation lamp
OFF timer display lamps
(set using remote control)
Max
Power lamp
(Lights when the power plug is inserted into the wall outlet)
Plasmacluster
Clean-sign lamp The colour changes when the air is dirty
Clean (green)
Little dirty (orange)
Very dirty (red)
ABOUT THE CLEAN-SIGN LAMP
• The dust sensor displays a clean sign depending on the environment at the time the power plug is inserted in the wall outlet.
• When the air is extremely dirty at the time the power plug is inserted, the clean sign lamp may light green since the polluted state is the environment which the sensor bases the pollution rate on.
• In this case, switch manually to the desirable operation mode as effective operation can’t be done in auto operation.
•To reset the base pollution rate of the clean-sign lamp remove and insert the power plug.
E-4
MODE-ON/OFF button
(Used to select operations or turn the unit off)
Main unit HEPA filter (white)
(Dust collection filter) (W/ apatite antibacterial filter)
Stamina-power carbon (black)
(Deodorization filter)
Pre-filter Front panel
Remote control Hook Stand
(Be sure to mount for tabletop instal­lation)
Thumbscrew
CLUSTER ION LAMP
Cluster ion operation is selected using the remote control.
Blue light
When the cluster ion operation is in the Clean mode or AUT O cluster ion mode and the air in the room is dirty, the light turns on and the unit will operate in the Clean mode.
Green light
When the cluster ion operation is in the Refresh mode or AUTO cluster ion mode and the air in the room is clean, the light turns on and the unit will operate in the Refresh mode.
Light off
No cluster ions are generated. If the lamp is to bright when sleeping, or if the ion generation noise is irritating, turn off the cluster ion operation.
ACCESSORIES
Remote control
(1 unit)

BACK

Handle Exhaust port
Power cord Power plug
Battery
(AA battery X 2 units)
When used on a tabletop
Stand
(1 unit)
Thumbscrew
(2 units) Located on bottom of stand
When wall mounting this product
Wall mounting bracket 1
Wall mounting bracket 2
Wood screw
(4 units)
Small screw
(2 units)
Cushions
(2 units)
E-5

INSTALLATION

WHEN USING THE UNIT ON A TABLETOP
FIXING THE STAND
Remove the front panel.
1
• At this time, also remove the pre-filter , stamina-power carbon and the HEPA filter. Front panel
2
1
Place the unit with its front
2
side facing down on a flat and stable surface.
• Place a soft cloth, etc., to prevent damaging the unit.
1
WHEN W ALL MOUNTING
CAUTION
•When mounting the air purifier on a wall, the wall will become dirty as time passes. T o pre­vent this, place a vinyl sheet, etc., around the unit.
• Ensure that the wall is suitable for mounting the air purifier.
• Do not install in a location with heavy smoke, such as in a kitchen, etc. The unit surf ace may crack as a result.
Determine the mounting location
1
Leave space around the bracket by referring to the illustration below. The unit cannot be mounted if there is insufficient spacing around the bracket.
75cm or more
69cm or more from the ceiling
Insert the tabs on the stand
3
into the holes on the main unit and fix the stand using the supplied thumbscrews (2 units).
Tabs
Thumb­screws
Holes
75cm or more
Mounting
60cm or more from sidewall
bracket 1
CAUTION
Mount on a flat sur­face
• Do not mount the unit to a thin wall with little strength such as a plas­terboard, etc. The unit may fall and can be v ery dangerous.
Size of main unit
75cm or more
60cm or more from sidewall
E-6
Mount mounting bracket 2 to the
2
main unit
Mount the bracket to the bac k of the main unit using the small screws included.
REMOVING THE UNIT
Pull the bottom of the unit towards you and then lift.
NOTES
Mounting bracket 2
Small screws (2 units)
Place the cushions as shown
3
Cushions (2 units)
Mount the main unit
4
(1) Align the horizontal positions of mounting
brackets 1 and 2 and hook the brac ket 2 to bracket 1.
(2) Hold the bottom
of the main unit, pull the unit to­wards you and then pull down.
• When removing the unit disconnect the power cord.
Check the installation
5
• Check to make sure that the tabs on mount­ing bracket 2 are securely mounted to the tabs on mounting bracket 1.
• Check that the power cord is not pinched.
E-7

PREPARATION

1
1
2
2
1
Be sure to remove the power plug from the wall outlet.

INSTALLING THE FILTERS

To maintain the quality of the filters, they are installed in the main unit within polyvinyl bags. Be sure to remove the filters from the polyvinyl bags before using the unit.
1
Remove the filters
Place the unit facing up
1
Place the unit on a table, etc., so that the stand does not touch the surface.
Remove the front panel
2
Press in the hook on the bottom of the front panel and lift to remove.
Soft cloth
Front panel
Table, etc.
Place so stand does not touch the surface
Hook
Prefilter
Remove the pre-filter, and
3
then remove the stamina­power carbon (black) and HEPA filter (white) that are inside the polyvinyl bags.
Stamina-power carbon

INSERTING BATTERIES IN THE REMOTE CONTROL

Remove the
1
back cover
Press and slide the back cover to re­move.
Insert batteries
2
Insert batteries with
and as shown
below.
Close the back
3
cover
About the batteries
• The battery life is about 1 year. Replace the batteries when the remote con­trol becomes inoperative.
• Incorrect usage of the batteries may cause battery fluid leakage and/or damage. Tak e caution of the following when handling:
•When replacing the batteries, replace
both batteries with new ones of the same type. (Use AA alkaline batteries (2 units) or AA manganese batteries (2 units).)
• When not using the unit or remote con-
trol for an extensive period, remove the batteries. This prev ents malfunction of the remote control from battery fluid leakage.
E-8
2
Install the filter
Remove the HEPA filter from
1
the polyvinyl bag and install it in the main unit with the
display facing up.
Insert so that the tabs on the HEPA filter are facing you. Proper operation cannot be achieved if installed incorrectly.
Remove the stamina-power car-
2
bon from the polyvinyl bag and install it in the main unit.
Make sure the tabs on the HEPA filter remain vis­ible.
Install the pre-filter
3
Insert the 4 tabs on the pre-filter in the holes of the main unit.
Fill in the usage start date on
4
the replacement label affixed on the back of the front panel and then mount the front panel.
Use the date as a guide for the filter replacement period.
Tabs
Replacement label
HEPA filter
Stamina-power carbon
Back of front panel

USING THE REMOTE CONTROL

• Operate the remote control facing the main unit (re­ceiver).
• The signal range is about 7m (front).
•Make sure there are no objects blocking the path of the signal.
•A Beep will be heard from the main unit when a signal is received.
NOTE
•Avoid strong impact on the remote control. In addition, do not wet the remote control or place it under direct sunlight or near a stove, etc. Malfunction may occur.
E-9
Receiver
Transmitter
For the first 30 seconds after the power plug is inserted

OPERATION

into the wall outlet, the unit will check the conditions of the air. If operation is set to ON during this time, the Clean sign lamp will alternately flash in green, orange and red. During this time, the Cluster ion lamp will light blue and the unit will be in the Clean mode.

MAIN UNIT OPERATION

MODE-ON/OFF button
Operations available with main unit
•AUTO operation
• Silent operation
•Median level operation
• High level operation
•Max level operation
•*Tobacco smoke mode operation
• Pollen mode operation
Plasmacluster
Cluster ion lamp
The unit will start operation when the MODE-ON/OFF button is pressed.
(The unit will start operation in AUTO mode)
• During operation, the cluster ion lamp will light. (During start of operation, the cluster ion mode will be AUTO)
The operation mode suitable for the usage condition can be set.
Stop AUTO operation
The fan level is automatically switched (High, Median, Silent) depend­ing on the amount of pollution in the air detected by the dust sensor for efficient air purification.
Silent operation
The unit will operate using little air.
Median ~ Max operation
The unit will operate with fan level of median, high or max.
Tobacco smoke mode operation
*
The unit will operate in High for 10 minutes, then the unit will return to the AUTO mode.
10 minutes: High fan level AUTO mode operation
It can not remove the no xious
*
substances (carbon monoxide etc.) from cigarette smoke.
Pollen mode operation
The unit will operate in High for 10 minutes, then the unit will alternately operate between Median and High.
10 minutes: High fan level 20 minutes: Median level 20 minutes: High fan level
E-10

REMOTE CONTROL OPERATION

•To start operation, press the ON/OFF button. A short beep will sound and operation will start in the AUTO mode.
•To stop operation, press the ON/OFF button again. A long beep will sound and operation will stop.
Transmitter
Operations available with remote control
• Fan level manual opera­tion
•Fan level A UTO operation
• Silent operation
• Max operation
•*Tobacco smoke mode operation
• Pollen mode operation
• OFF timer setting
• Cluster ion select
AUTO cluster ion Clean mode Refresh mode
Manual (fan level) button
The fan level can be switched between Silent, Median, High and Max.
Silent operation but­ton
Operation will be in the Silent mode with little air.
Tobacco smoke
*
mode operation but­ton
Unit will operate effectively when smoking cigarettes, etc.
ON/OFF button
Used to start AUTO operation (short beep) and stop opera­tion (long beep).
Filter reset button
Press this button after replac­ing the filters.
It can not remove the noxious
*
substances (carbon monoxide etc.) from cigarette smoke.
RESET
Plasmacluster
AUTO OFF
AIR PURIFIER
AUTO (fan level) but­ton
The fan speed depends upon the amount of pollution in the air.
Max operation button
Used to quickly clean the air in the room.
Pollen mode opera­tion button
The unit operates effectively when you suspect pollen in the air.
OFF timer button
Used to set the OFF timer. The set time switches ever y time the button is pressed as shown below. 1 hour 4 hours 8 hours Cancel
• The remaining time is indi­cated by the lamp as time
passes.
• The unit will stop operation when the timer is up.
At the start of operation, the Cluster ion mode is also set to AUTO.
Cluster ion select button
AUTO cluster ion button
The unit will switch between the Clean mode and Refresh mode automatically depending on the amount of pollution in the air detected by the dust and odour sensor.
Clean button
The unit will constantly operate in the Clean mode. The Clean mode is effective for removing mold fungus in the air. (Cluster ion lamp on (blue))
If the room smells especially moldy, operate the unit in the Clean mode.
E-11
OFF button
The generation of ions is stopped and the cluster ion lamp is turned off.
Refresh button
The unit will constantly operate in the Re­fresh mode. The Refresh mode maintains the balance of ions in the air for a refresh­ing effect. (Cluster ion lamp on (green))

CARE AND MAINTENANCE

(To maintain the best performance of this product, please clean the unit periodically.)
When cleaning, be sure to remove the power plug from the wall outlet. In addition, never handle the power plug with wet hands. Electrical shock and/or bodily injury may occur as a result.

MAIN UNIT

For soiling on the main unit and the installed surface, clean as early as possible. Stubborn dirt may be hard to remove.
Dry wipe with a soft cloth
For stubborn dirt, wipe with a soft cloth damp­ened with water or warm water of 40°C or less.
Do not use volatile fluids
Benzene, paint thinner , polishing powder , etc., may damage the unit surface.
Do not use detergents
Detergent ingredients may damage the unit surface.
Do not get wet
Never apply water on the unit.
ODOR SENSOR DUST SENSOR
The sensitivity of the sensors will become unstable if the odor or dust sensor is dirty or blocked. Remove dust on the surfaces of the sensor openings using a vacuum cleaner.

FILTERS

Clean using the nozzle of a vacuum cleaner without removing the pre-filter.
NOTE
Never wash or clean the HEPA filter or stamina-power carbon by directly con­tacting the nozzle of a vacuum cleaner. This will greatly decrease the perform­ance of the filters.
Odor sensor Dust sensor
E-12

GUIDE FOR LIFE OF FILTERS

The replacement period differs depending on the usage hours and
location of installation.
Some of the odor ingredients adsorbed by the filters become separated
and are discharged through the exhaust port as odor. Depending on the usage environment, this odor may become strong in several months and the exhaust port may smell. If dust or odors cannot be removed easily, replace the filters.
(Refer to page1, FOR UNDERSTANDING THE PRODUCT)
Guide for filter replacing timing
• The following is a guide from JEM 1467 b y Japan Electrical Manufacturers Association in Japan, and in JEM 1467, the replacement period is set as when smoking 10 cigarettes per day and the dust collection/deodorization power is reduced by half that of new filters.
• HEPA filter About 5 years after opening
• Stamina-power carbon About 5 years after opening
• The filter timer lamp is programmed to light in about 5 years, when using the unit for 12 hours everyday, in order to indicate accumulated usage time of the guide above.
• The filter timer lamp is to be used only as a guide.
• The operation hours are kept in memory even when removing the power plug for transportation to another room, etc.
REPLACING THE FILTERS
See page 8 “Installing the filters” for the replacement method.
1
After replacing the filters:
2
Be sure to press the Reset button on the remote control with the power plug inserted in the wall outlet. A short beep will be heard and the operation hours stored in the memory will be reset. If the filter replacement lamp is on, the lamp will turn off.
Fill in the usage start date of the filters on the date label in-
3
cluded with the replacement filters. Affix the label on top of the replacement label that is already on the back of the front panel.
Replacement filters
• HEPA filter: 1 unit
• Stamina-power carbon: 1 unit
Model: FZ-40SEF Please ask for replacement filters at your dealer of purchase.
Cautions concerning the disposal of filters
Please dispose of replaced filters according to the local disposal laws and regulations. HEPA filter materials:
• Filter: Polypropylene
• Frame: Polyester
Stamina-power carbon materials:
• Deodorizer: Activated charcoal
• Frame: Polyester
E-13

TROUBLESHOOTING

Before calling for repair, check the symptoms below for possible remedies, since the problem may not be a malfunction of the unit.
SYMPTOM REMEDY (not a malfunction)
The remote control does not work
Odors and smoke cannot be re­moved easily
The Clean sign lights green even when the air is dirty
The Clean sign lights orange or red even when the air is clean
The cluster ion lamp remains green (blue) and does not change
A sound is heard from the unit
The discharged air smells
The unit does not operate even when smoking cigarettes
Click, click
Tick, tick, tick
•Have the batteries depleted?
• Are the batteries inserted correctly?
• Is a fluorescent lighting in the room flickering due to service life? (Refer to E-3)
• Are the filters heavily soiled? (Refer to E-13)
• Is the opening of the dust sensor blocked or clogged?
•Was the air already dir ty when the power plug was inserted into the wall outlet? (Refer to E-4)
• The sensitivity of the sensor becomes unstable when the opening of the dust sensor is dirty or is clogged. Clean the dust around the sensor opening using a vacuum cleaner. (Refer to E-12)
• During the Clean mode (or Refresh mode), the cluster ion lamp colour will not change.
• This is the sound that is emitted when the unit is in t h e Refresh mode. If the sound is irritating, switch the unit to the Clean mode.
• This is the sound that is emitted when the unit is generating cluster ions. If the sound is irritating, such as when sleeping, etc., set the Cluster ion mode to OFF.
• The ozone generated by the cluster ion generator may have an odor. However , the density of oz one generated is very little and is harmless to the human body. Furthermore, the ozone
decomposes quickly so it does not accumulate in the room.
• Is the unit installed in a location that is difficult for the sensors to detect cigarette smoke?
• Are the odour and dust or dust sensor openings blocked or clogged? (In this case, clean the openings.)
(Refer to E-12)
The applicable floor surface area is the surface area for when operating the unit in Max fan level.

SPECIFICATIONS

Power supply 220V-240V 50Hz
Fan level operation
Fan level adjustment Max High Median Silent Rated power 39W 21W 10W 4W Fan level 240m3/hour 180m3/hour 117m3/hour 30m3/hour Applicable floor surface ~31m Cord length 2.5m
Dimensions 415mm(W)X197mm(D)X572mm(H)(W/ stand) Weight 6.6kg
(According to Japan Electrical Manufacturers’ Association JEM1467)
2
About the reduction of standby power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 0.8W of standby power. (At this time, the power lamp will be on) For the conservation of energy, remove the power plug when not using the unit
SHARP CORPORATION
OSAKA, JAPAN
E-14
TINS-A056KKRZ 02HK 1