Sharp FU-S51E Operating Manual

0 (0)

R

Free standing type Freistehende Ausführung

Type de table / installation murale De sobremesa / instalación en la pared Tipo da scrivania / parete Tafelmodel / wandmodel

*Plasmacluster is a trademark of Sharp Corporation.

FU-S51E

AIR PURIFIER

OPERATION MANUAL

ENGLISH

 

LUFTREINIGER

 

DEUTSCH

BEDIENUNGSANLEITUNG

DEUTSCH

 

PURIFICATEUR D'AIR

 

 

FRANÇAIS

MANUEL D'UTILISATION

 

PURIFICADOR DE AIRE

 

 

ESPAÑOL

MANUAL DE USO

 

PURIFICATORE

 

 

ITALIANO

MANUALE OPERATIVO

DELL'ARIA

 

LUCHTREINIGER

 

 

NEDERLANDS

GEBRUIKSAANWIJZING

 

 

 

Please read before operating your new Air Purifier

The air purifier draws in room air from its air intake, lets the air pass through a Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan.

As air passes through, a new HEPA Filter can remove 99.97% of dust particles, of as small as 0.3 microns. The Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the filter. (Odour elements are absorbed by HEPA Filter as well.)

Some odour ingredients absorbed by the filters may become separated and may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in a condition significantly more severe than household use, this odour may become strong in a shorter period than expected.

If the odour persists, then the filters are fully expended and it is necessary to purchase the optional replacement filter.

NOTE

The air purifier is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot completely remove the odour. (for example, odours from construction materials and pet odours).

It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.

ENGLISH

FEATURES

ION SHOWER

New ION SHOWER Operation Mode releases the concentrated Plasmacluster Ions, and effectively removes the pollen and mold, and also controls the activity of

airborne virus, mold, and allergen.

Plasmacluster Ion Control

Your new air purifier will control the ratio of negative ions and positive ions depending on the condition of the room.

• Clean Mode

Approximately the same numbers of positive and negative ions are discharged.

• AUTO Plasmacluster Ion Mode

The unit will switch between Clean Mode and Ion Control Mode* automatically depending on the amount of impurities in the air detected by the odour and dust sensors.

*Ion Control Mode

Negative ions will be released in an increased rate and controls the ion balance.

• Filters

1)Washable Active Carbon Filter

Absorbs odour elements. Washable to maintain optimum deodorization performance.

2)HEPA (High Efficiency Particulate Air) Filter with Microbial Control

High-efficiency particle collection including pollen and dust.

CONTENTS

IMPORTANT SAFETY INSTRUCTIONS ....

E-2

• WARNING ....................................................

E-2

• CAUTIONS CONCERNING OPERATION ...

E-3

• INSTALLATION GUIDELINES .....................

E-3

• FILTER GUIDELINES ..................................

E-3

PART NAMES ..........................................

E-4

• MAIN UNIT DISPLAY ...................................

E-4

• ILLUSTRATIVE DIAGRAM ..........................

E-4

• BACK ...........................................................

E-5

• INCLUDED ...................................................

E-5

PREPARATION........................................

E-6

• FILTER INSTALLATION ...............................

E-6

OPERATION ............................................

E-8

• MAIN UNIT OPERATION .............................

E-8

CARE AND MAINTENANCE .................

E-10

• MAIN UNIT ................................................

E-10

• FILTER ......................................................

E-10

• SENSORS ................................................

E-10

• WASHABLE ACTIVE CARBON FILTER CARE ....

E-11

• FILTER REPLACEMENT

E-12

GUIDELINES ............................................

TROUBLESHOOTING...........................

E-13

SPECIFICATIONS .................................

E-14

INFORMATION ON PROPER DISPOSAL ... E-15

Thank you for purchasing the SHARP Air Purifier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: “Important Safety Instructions.”

After reading this manual, retain it in a convenient location for future reference.

E-1

IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should be followed, including the following:

WARNING - To reduce the risk of electrical shock, fire or injury to persons:

Read all instructions before using the air purifier.

Use only a 220-240 volt outlet.

Do not use the air purifier if the power cord or plug is damaged or the connection to the wall outlet is loosened.

Periodically remove dust from the power plug.

Do not insert fingers or foreign objects into the intake or air outlet.

When removing the power plug, always hold the plug and never pull the cord.

Electrical shock and/or fire from short circuit may occur as a result.

Do not remove the plug when your hands are wet.

Do not use this air purifier near gas appliances or fireplaces.

Remove the power plug from the wall outlet before cleaning the unit and when not using the unit.

Electrical shock from bad insulation and/or fire from short circuit may occur as a result.

If the power cord is damaged, it must be replaced by the manufacturer, its service agent, Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard.

Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a bathroom.

Be cautious when cleaning the air purifier. Strong corrosive cleansers may damage the exterior.

Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs.

NOTE - Radio or TV Interference

If this air purifier should cause interference to radio or television reception, try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation distance between the air purifier and radio/TV receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

E-2

IMPORTANT SAFETY INSTRUCTIONS

CAUTIONS CONCERNING OPERATION

Do not block the intake and air outlet.

Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam.

Do not lay the unit down when using.

Always hold the handle on the back of the unit when moving it.

Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in bodily injury.

Do not operate the unit without the filter.

Do not wash and reuse HEPA filter .

It not only does not improve filter performance, it may cause electric shock or malfunction.

Clean the exterior with a soft cloth only.

The unit surface may be damaged or cracked.

In addition, the sensors may malfunction as a result.

INSTALLATION GUIDELINES

During the operation of the product, please place the unit at least 2m away from equipments which involve electric wave such as televisions, radios or wave clocks, in case electrical interference occurs to such equipment.

Avoid a location where the sensor is exposed to direct wind.

The unit may not operate properly.

Avoid locations where curtains, etc., come into contact with the intake or air outlet.

Curtains, etc., may become dirty or a malfunction may occur.

Avoid locations where the unit is exposed to condensation, due to drastic temperature changes.

(Use under appropriate conditions between 0 and 35˚C in the room.)

Place on a stable surface with sufficient air circulation.

When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.

Do not install when there is generation of lampblack, such as in a kitchen, etc.

The unit surface may crack or the sensor may malfunction as a result.

Leave about 60cm of space from the wall.

The wall behind the air outlet may become dirty as time passes. When using the unit for extended period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall.

FILTER GUIDELINES

• Follow the instructions in this manual for correct care and maintenance of the filters.

E-3

Sharp FU-S51E Operating Manual

PART NAMES

MAIN UNIT DISPLAY

AUTO Operation Indicator Light

Pollen Mode Indicator Light

Fan Speed Indicator Lights

Plasmacluster Ion Mode

Indicator Lights

Plasmacluster Ion Mode

Selection Button

Mode Selection Button

ION SHOWER Indicator Light

ION SHOWER Mode Button

ILLUSTRATIVE DIAGRAM

Date Label

Odour Sensor

 

Main Unit

 

HEPA Filter

 

(blue / white)

 

Washable Active

 

Carbon Filter

Filter Support

Front Panel

E-4

Loading...
+ 14 hidden pages