SERVICE MANUAL
No. 00ZFO4700USM1
FO-4700U
FO-47UC
SUPPLEMENT
How to install the verification stamp
(FO-45VS)
1. Open the operation panel unit.
2. Remove the screw (A1) x 1 pc. and open
the operation panel more widely.
FACSIMILE
MODEL FO-4700
Operation panel unit
Open
Screw (A1) x 1
Document
guide stopper
3. Remove the screws (B1) x 5 pcs., to remove
lower document guide.
4. Remove CIS unit
1) Carefully bend 2 hooks and remove CIS
connector.
5. Install the verification stamp (FO-45VS) with the
screw (B2) x 1pc.
Screw (B2) x 1
CIS unit
Screw (B1) x 5
Lower
document
guide
CIS
connector
FO-45VS
Stamp cable
to Control PWB
Scanner frame
Hook
Hook
SHARP CORPORATION
1 - 1
This document has been published to be used
for after sales service only.
The contents are subject to change without notice.
FO-4700U
FO-47UC
6. Wire treatment
Stamp cable must be passed through six ribs as
shown in fig.1.
Connect the stamp cable to CNSTP (2 pin) of con
trol PWB
Scanner feed shaft
Front / Let out / Doc
sensor cable
CIS cable
Rib
Front sensor
Rib
Let out sensor
Rib
Doc sensor
Rib
Scanner
frame
Stamp cable
to Control PWB
(CNSTP) 2pin
Rib
Scanner drive roller 1
7. Soft switch setting
When you install the verification stamp (FO-45VS),
set the soft SW 27. No. 3 initial setting to "1".
8. Replacing the verification stamp
If you are using the verificat ion stamp function,
you will need to replace the ink cartridge in the
stamp unit when it runs out of ink (when the
stamped mark on original documents be co mes
faint). A new ink cartridge can be obtai ned from
your dealer.
1
Remove the original document OUT tray.
Rib
Fig. 1
Rib
Rib
On account of the length of the stamp cable to the
control PWB, it is wired at shortest.
Insert the new ink cartridge into the machine
3
Stamp
(FO-45VS)
(make sure tha t the tab is facing out) .
Ink cartridge
2
Press down on the protruding tab of the green
ink cartridge and pull the cartridge out with
your fingers.
1 – 2
4
Replace the original document OUT tray.
Stamp only (20 pieces)
Parts code : UINK-2009SC01
SHARP CORPORATION
Communication Systems Group
Quality & Reliability Control Center
Higashihiroshima, Hiroshima 739-0192, Japan
Printed in Japan
A9909-1832SS•IS•T