WiSun Wireless Sensor
T Test Sensors = OFF Test Sensors = ON
Wind, Sun Wireless Sensor to be coupled with SEAV electronic control units for the automation of rolling window shutters
and sun blinds.
- Mod. WiSun 433 : 433.92 MHz
T
ECHNICAL DATA
- Power supply: 230V~ 50/60Hz 3W max.
- Working temperature: -10÷55°C
- Working frequency: see model
- Sensitivity Anemometer: 5 ÷ 40 Km/h
- Sun Sensor Sensitivity: 5 ÷ 40 Klux
- Packaging dimensions: 240x185x110 mm.
- Container: PC UL94V-0 ( IP54 )
C
ONNECTIONS OF THE
1: 230V~ Line input (Phase).
2: 230V~ Line input (Neutral).
I
NITIAL FUNCTIONING CONDITION
The device can only work in conjunction with one or more
SEAV electronic control units prearranged for radio reception
of information relating to the state of the sensors. For the functioning, it will be necessary to carry out the programming operation of the Wireless Sensor on the control unit to which it
will be coupled (see par. “CODE Sending of Radio Identifier” ).
In the default factory setting, each Wireless Sensor example
produced has a different identifier.
W
IND SENSOR FUNCTIONING
The device will send to the control unit to which it has been
coupled, a closing control every time the set Wind threshold is
exceeded.
S
UN SENSOR FUNCTIONING
The device will send to the control unit to which it has been
coupled, a downward control after 10 minutes of brightness
higher to the threshold selected by means of the VR1 trimmer
and displayed through the switching on of the SUN MONITOR
LED; it will send an upward control after 10 minutes of brightness lower than the selected threshold.
Select send sensor status information Fast / Slow:
The device, through the Connector CN3 allows you to select
the radio sending of information about the status of Sun sensor
so Fast (= 2 minutes) or slow (Slow = 10 minutes).
In the factory configuration the selection of radio transmission
speed is kind of slow (CN3 pos. 3-4), to speed up the reaction
time of the sun sensor (commands sent every 2 min-utes about
instead of every 10), place CN3 pos. 4-5.
The operation must be performed with the sensor is not
powered.
Regulation of sensitivity to the Sun ( 5
The device allows to regulate the intervention threshold due to
brightness, by means of the VR1 trimmer. The switching on of
the SUN MONITOR LED on the device indicates that the Sun
intensity exceeds the selected intervention threshold, in this
way we will have a reference to the current light conditions to
establish the desired one.
P
ROGRAMMING KEYS AND INDICATOR
SEL Key: selects the type of function to memorise, the choice
is indicated by the flashing of the LED. By repeatedly pressing
the key, it is possible to position oneself on the desired function. The selection remains active for 15 seconds, displayed by
the flashing LED, after which the control unit returns to the
original status.
CN1 T
ERMINAL BOARD
÷÷÷÷
40 Klux )
LED
SET Key: carries out the programming of the function chosen
with the SEL key.
Indicator LED
LED on: option memorised.
LED off: option not memorised.
LED flashing: option selected.
---------------------- MAIN MENU -----------------
LED Reference LED Off LED On
1) CODE Send RFID = OFF Send RFID = ON
2) SPEED Wind Safety 25 Km/h
3) WIND Wind Safety = OFF
4) SUN Sun Sensor = OFF
5) RAIN Not used Not used
6) TES
1) CODE (Sending of Radio Identifier)
The coupling of the Wireless Sensor to a control unit must be
carried out as follows: activate the Wireless Sensor programming procedure on the control unit (see control unit technical
manual), with the SEL key position yourself on the flashing of
the CODE LED and press the SET key for about 1-2 seconds:
at the same time, the Sensor will send an identifying code signalled by the flickering of the CODE MONITOR LED.
Check that in the coupled control unit there is confirmation of
the occurred Sensor programming (see control unit technical
manual). In this way, the Wireless Sensor is coupled to the
control unit and it will send to the same controls dependant upon the meteorological conditions.
Repeat the operation in case the same Sensor is to be programmed on other control units.
2) SPEED (Programming of Wind Safety threshold)
Display of the programmed Wind threshold
The display of the wind Safety threshold selection is carried out
as follows: with the SEL key position yourself on SPEED LED,
the LED will start to double flash for the number of times equal
to the wind Safety threshold in the memory (to every double
flash of the SPEED LED corresponds an increase of 5 Km/h),
(example: 5 flashes of SPEED LED = 25 Km/h).
Selection of the wind Safety threshold from 5 to 40 Km/h
The sensor is supplied with the wind Safety intervention
threshold equal to 25 Km/h (SPEED OFF LED).
The programming of the wind Safety threshold selection is carried out as follows: with the SEL key position yourself on
SPEED LED and press the SET key to start the programming
procedure: at the same time, the SPEED LED will start to double flash; (every double flash of the SPEED LED corresponds
to an increase of 5 Km/h), once the desired threshold has been
reached, press the SET key; the selected value will be memorised at the same time and the SPEED LED will remain on (ex-
ample: 5 double flashes of SPEED LED = 25 Km/h).
It is possible to repeat the operation in case of an incorrect
programming.
3) WIND (Wind Sensor ON/OFF)
Deactivation of the Wind Sensor
The device is supplied with the Wind Sensor enabled (WIND
ON LED).
The deactivation of the Wind Sensor can be carried out as follows: with the SEL key position yourself on the flashing of the
WIND LED and press the SET key for an instant: at the same
time, the WIND LED will switch off and the Wind Sensor deactivation will be complete. It is possible to repeat the operation
to activate the Wind Sensor.
1 Rev. 1.1 18/10/2013

4) SUN (Sun Sensor ON/OFF)
Enabling the Sun Sensor
The device is supplied with the Sun Sensor disabled (SUN
OFF LED).
The enabling of the Sun Sensor can be carried out as follows:
with the SEL key position yourself on the flashing of the SUN
LED and press the SET key for an instant: at the same time,
the SUN LED will remain on and the Sun Sensor enabling will
be complete. It is possible to repeat the operation to disable
the Sun Sensor.
5) RAIN (Not Used)
6) TEST (Test Sensors ON/OFF)
The device is supplied with the Wind - Sun Test Sensors disabled (TEST OFF LED).
The activation of the Wind - Sun - Rain Test Sensors can be
carried out as follows: with the SEL key position yourself on the
flashing of the TEST LED and press the SET key for an instant:
at the same time, the TEST LED will switch on and the activation of the Wind - Sun Test Sensors will be complete. It is possible to repeat the operation to disable the Test Sensors.
Anemometer Test: manually rotate the Anemometer blades
and, at the same time, the WIND MONITOR LED will switch
on, signalling the radio sending of the necessary information to
the previously configured coupled control unit (signalled by the
flickering of the CODE MONITOR LED), controlling the ascent
for 5 sec.
Sun Sensor Test: rotate VR1 trimmer as far as possible
clockwise (in + position) and, at the same time, the SUN
MONITOR LED will switch on, signalling the radio sending of
the necessary information to the previously configured coupled
control unit (signalled by the flickering of the CODE MONITOR
LED), controlling the descent for 5 sec. Rotate the VR1 trimmer VR1 anti-clockwise (in - position) and, at the same time,
the SUN MONITOR LED will switch off, signalling the radio
sending of the necessary information to the previously configured coupled control unit (signalled by the flickering of the
CODE MONITOR LED), controlling the ascent for 5 sec.
SENSORS MONITOR
The control unit presents four "monitor" indicator LED with
which it is possible to display the radio transmission of the information relating to each sensor.
---------------------- LEDS MONITOR -----------------
LED Reference LED Off LED On
CODE MONITOR Info = OFF Info = ON
WIND MONITOR Info = OFF Info = ON
SUN MONITOR Info = OFF Info = ON
RAIN MONITOR Not used Not used
R
ESET
In case it is necessary to reset the control unit default factory
configuration, press the SEL and SET keys together so that all
indicator LED switch on and off at the same time.
2 Rev. 1.1 18/10/2013