SEAV LRX 2205 User Manual

0 (0)

GB

ELECTRONIC CONTROL UNIT LRX 2205

OPERATIONAL DATA:

Single-phase electronic control unit with incorporated radio receiver for the automation of sliding and swinging gates and rolling shutters, at power levels of up to 1500 Watts.

- Mod. LG

2205

: Without radio receiver

- Mod. ( LR

2205 )

: 306

Mhz

- Mod. ( LR

2205 / 330 )

: 330

Mhz

- Mod. ( LR

2205 / 418 )

: 418

Mhz

- Mod.

LRS 2205

 

: 433.92 Mhz

- Mod.

LRS 2205

SET

: 433.92 Mhz “narrow band”

- Mod.

LRH 2205

 

: 868.3 Mhz “narrow band”

( ) Product intended for those countries where its use is permitted

TECHNICAL DATA:

 

 

 

 

- Power supply

:

230

V a/c 50-60 Hz 2100 W max.

- Flashing beacon output

:

230

V a/c 500 W max.

- Motor output

:

230

V a/c 1500 W max.

- Photoelectric cells

 

 

 

 

power supply

:

24

V a/c 3 W max.

- Low voltage safety

 

 

 

 

features and commands :

24

V c/c

- Operating temperature

: -10 ÷55 °C

- Radio receiver

: see model

- Op. transmitters

:

12-18 Bit or Rolling Code

- Max stored TX codes

:

75

 

 

- Box dimensions

:

110 x 121 x 47 mm.

- Container

:

ABS V-0 (IP54).

TERMINAL BOARD CONNECTIONS:

CN1:

1: 230 V a/c line input (Phase).

2: 230 V a/c line input (Neutral).

3: Clean contact output for Flashing Beacon/Courtesy Light.

4: Clean contact output for Flashing Beacon/Courtesy Light.

5: Opening motor output.

6: Shared motor output.

7: Closing motor output.

CN2:

1: Input IN3 = FCAP opening stop limit (NC).

:Input IN3 = DS2 safety device inverts during closure,

2: Shared GND input.

3: Input IN4 = FCCH closing stop limit (NC).

:Input IN4 = DS3 safety device inverts during closure,

Stop during opening (NC).

4: Photoelectric cell control and power supply (24 V a/c).

5: Photoelectric cell control and power supply (GND).

6: Input IN1 = P/P open-close command button (NA). Input IN1 = UP open only command button (NA).

7: Shared GND input.

8: Input IN2 = DS1 safety device inverts during closure (NC). Input IN2 = DOWN close only command button (NA). Input IN2 = BL device. Emergency lock (NC).

9: Earth antenna input.

10: Antenna hot pole input.

 

Step-by-Step keypad operation:

 

The following operation is obtained using the low voltage

 

keypad to control the shutter:

 

the first press opens the gate until the motor timer reaches zero

 

or until the opening stop limit is reached, the second press

 

closes the gate; if a button is pressed before the opening stop

 

limit is reached, the control unit stops motion during both

 

opening and closing. A further command restarts motion in the

 

opposite direction.

 

Operation using different models of radio control:

 

Different models of radio control may be programmed: by

 

storing a code (1 button) a cyclic step by step operation (Open

 

- Stop - Close) may be achieved, and by storing two different

 

codes (2 buttons) separate commands are created, one for

 

opening and one for closing. Storing three different codes (3

 

“BeFree” series buttons) produces three separate commands:

 

the first for Open, the second for Stop and the third for Close.

 

Operation using a 1-button radio control:

 

The following type of operation is obtained using a radio control

 

with a single button: the first press controls the opening

 

movement of the shutter until the motor timer stops. The

 

second press controls the closing movement of the shutter. If

 

the button is pressed before the motor stops running, the

 

control unit will stop the shutter from moving and the button will

 

need to be pressed again to reactivate the motor in the

 

opposite direction.

 

Operation using a 2-button radio control:

 

The following type of operation is obtained using a radio control

 

with 2 buttons: the first button (“Up”, corresponding to the

 

opening movement) controls opening until the motor stops

 

running and the second button (“Down”, corresponding to the

 

closing movement) controls the closure of the shutter. If the

 

opening movement is interrupted with another “Up” command,

 

the motor will continue to run in the upward movement

 

direction. If, however, the movement is interrupted with a

 

“Down” command, the control unit will stop the motor.

 

The procedure is the same for the closing movement phase.

 

Operation using a 3-button radio control (BeFree series):

 

The following type of operation is obtained using a radio control

 

from the BeFree series: the Up button controls the opening

 

movement until the set motor time has elapsed, the Stop button

 

makes the shutter stop and the Down button controls the

 

closure of the shutter. If a stop command is sent during the

 

opening or closing movement, the control unit causes this

 

movement to stop. If a command which is the opposite

 

direction to the current movement is sent during the opening or

 

closing movement, the control unit causes the shutter to

 

change direction.

 

Automatic closing:

 

The control unit can close the shutter automatically without

 

sending additional commands.

 

The selection of this operation mode is described in the Pause

 

Time programming mode.

 

DS1 safety device operation:

 

DS1 operation anticipates the connection of a general safety

 

device with contact (NC). If not used, this input must be

 

bridged.

 

Action is not taken into account during the opening stage but

 

causes inverted motor action during the closing stage. Another

 

safety device operating mode is described in the

 

extended menu when programming DS1 = INV or DS1 =

 

Lock.

1

Rev. 1.1 04 -10 - 2007

SEAV LRX 2205 User Manual

DS2 safety device operation:

DS2 operation anticipates the connection of a general safety device with contact (NC). If not used, this input must be bridged.

Action is not taken into account during the opening stage but causes inverted motor action during the closing stage.

DS3 safety device operation:

DS3 operation anticipates the connection of a general safety device with contact (NC). If not used, this input must be bridged.

An intervention during the opening or closing stage causes the movement to stop.

Operation with TIMER:

The control unit may be connected to a timer instead of using the open-close command button ( IN1 ).

Example: at 8:00 a.m. the timer closes the contact and the control unit opens the shutter; at 6:00 p.m. the timer opens the contact and the control unit closes the shutter. Between 8:00 a.m. and 6:00 p.m. at the end of the opening phase, the control unit disables the flashing beacon, the automatic closing stage and the radio controls.

PROGRAMMING:

SEL button: selects the type of function to be stored; selection is indicated by a flashing LED.

The desired function can be selected by pressing the button repeatedly. The selection remains active for 10 seconds (indicated by the flashing LED); after 10 seconds, the control unit returns to its original status.

SET button: programmes the information according to the type of function selected previously using the SEL button. IMPORTANT: The function of the SET button can be replaced with the radio control, if programmed previously (CODE LED on).

MAIN MENU

The control unit is supplied by the manufacturer with the option of selecting some important functions.

---------------------- MAIN MENU -----------------

 

Reference LED

LED Off

LED On

 

 

1)

AUT/MANUAL

Step-by-Step

User Present

 

 

2) CODE

No code

Code entered

 

 

3)

INB.CMD.AP

Disabled

Enabled

 

 

4)

LAMP/CORT

Flashing

Courtesy light

 

 

5)

T. MOT.

Automatic motor time

Time programmed

 

 

6)

T. PAUSA.

Without aut. closing

With aut. closing

 

 

7) SEL INPUT 1 - 2

IN1 = P/P - IN2 = DS1

IN1 = Up - IN2 =

 

 

Down

 

 

 

1) AUT/MANUAL (Step-by-Step /Manual operation):

The control unit is supplied by the manufacturer with the manual “User Present” operation mode disabled. To enable the function proceed as follows: use the SEL button to navigate to the AUT/MANUAL LED when flashing and press the SET button: the AUT/MANUAL LED will then remain lit in a fixed manner and programming is complete.

In this mode, using both the radio control and the low voltage keypad to control the gate, the following operation is obtained: the control is constantly enabled so that the gate or shutter can be moved as necessary. The movement stops immediately when the control is released. Repeat the operation to restore the previous configuration.

2) CODE: (Radio control code)

The control unit can store up to 75 radio controls with different fixed or rolling codes.

Programming using a 1- or 2-button radio control:

To programme the transmission codes in the radio control, proceed as follows: press the SEL button and the CODE LED will begin to flash; at the same time send the first code ("Up", corresponding to the opening movement) on the radio control. At this point the CODE LED will begin to flash quickly. Send the second code (“Down”, corresponding to the closing movement) to be stored and the CODE LED will remain lit: programming is now complete. If the second code is not sent within 10 seconds the control unit exits the programming stage, selecting operation using one button on the radio control.

Programming using a 3 button radio control in the “B eFree Series”:

The control unit allows you to store the whole “BeFree” radiocontrol by programming only the UP button.

To programme the “BeFree” radio-control codes, follow this procedure: press the SEL button; the CODE LED begins to flash. Press the UP button of the desired radio control at the same time; the CODE LED will remain lit and programming will be complete.

Deleting the codes: To delete all transmission codes stored in the memory, proceed as follows: press the SEL button; the CODE LED starts flashing. Then press the SET button; the CODE LED switches off and the procedure is complete.

Radio control already stored warning:

The control unit can store up to 75 radio controls with different fixed or rolling codes. If the user attempts to perform the programming procedure for a radio control which is already stored in the memory, the CODE LED will begin to flash rapidly for a few moments to indicate that this procedure cannot be performed; the unit then returns to the programming stage once again.

Maximum number of radio controls which can be stored: The control unit can store up to 75 radio controls with different fixed or rolling codes. If the maximum number of radio controls has been reached, and a programming process started, the control unit will indicate that the programming process has failed by flashing all the LEDs except the CODE LED, which will remain lit in a constant manner. After 10 seconds the control unit exits the programming mode.

3)INB. CMD. AP: (command inhibition during opening and pause time, if entered)

The command inhibition function during opening and pause time, if entered, is used when automation includes the loop detector. During opening or pause time the control unit ignores the commands given by the loop detector, keypad and radio control. During the closing phase a command sent by the loop detector, keypad or 1-button radio control will cause the motor direction to be inverted; if operating with a 2-button radio control the button corresponding to opening movement will cause the motor direction to invert and the closing movement button is ignored; if operating with a radio control in the BeFree series the opening movement button causes inversion, the closing movement button is ignored and the Stop button causes the motor to stop.

The control unit is supplied with the default setting of the command inhibition function during opening and pause time not enabled. To enable the function proceed as follows: use the SEL button to reach the stage when the INB.CMD.AP LED is flashing, then press the SET button: at this moment the INB.CMD.AP LED lights up and remains constant. Repeat the operation to restore the previous configuration.

4)LAMP/CORT: (Selection of flashing beacon or courtesy light)

2

Rev. 1.1 04 -10 - 2007

Loading...
+ 3 hidden pages