The information presented in this manual is not warranted by Schneider Electric to be authoritative, error free,
or complete. This publication is not meant to be a substitute for a detailed operational and site specific
development plan. Therefore, Schneider Electric assumes no liability for damages, violations of codes,
improper installation, system failures, or any other problems that could arise based on the use of this
Publication.
The information contained in this Publication is provided as is and has been prepared solely for the purpose of
evaluating data center design and construction. This Publication ha s bee n compiled in g ood faith by Schneid er
Electric. However, no representation is made or warranty given, either express or implied, as to the
completeness or accuracy of the information this Publication contains.
IN NO EVENT SHALL SCHNEIDER ELECTRIC, OR ANY PARENT, AFFILIA TE OR SUBSIDIAR Y COMPANY
OF SCHNEIDER ELECTRIC OR THEIR RESPECTIVE OFFICERS, DIRECTORS, OR EMPLOYEES BE
LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL, OR INCIDENTAL
DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, CONTRACT,
REVENUE, DATA, INFORMATION, OR BUSINESS INTERRUPTION) RESULTING FROM, ARISING OUT,
OR IN CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS PUBLICATION OR THE CONTENT,
EVEN IF SCHNEIDER ELECTRIC HAS BEEN EXPRESSLY ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH
RESPECT TO OR IN THE CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME
WITHOUT NOTICE.
Copyright, intellectual, and all other proprietary right s in the content (including bu t not limited to soft ware, audio,
video, text, and photographs) rests with Schneider Electric or it s licensors. All rights in the content not expressly
granted herein are reserved. No rights of any kind are licensed or assigned or shall otherwise pass to persons
accessing this information.
This Publication shall not be for resale in whole or in part.
Table of Contents
General Information...............................................................................................1
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual v
General Information
Overview
KVM2132P / KVM2116P / KVM1116P KVM Switches
NOTE: Save these instructions. Read and adhere to all the instructions. All servicing must be performed
by authorized personnel only.
The KVM switch allows local and remote users to monitor and access multiple servers from a single
console. The switch models differ by number of buses and KVM ports.
SKUBus SupportKVM Ports
KVM2132P1 Local, 2 Remote32
KVM2116P1 Local, 2 Remote16
KVM1116P1 Local shared with 1Remote16
• Each bus permits a separate user session so that up to three (KVM2132P or KVM2116P)
concurrent independent connections to the attached servers can take place.
• The switches use TCP/IP communications protocol. They can be accessed by their IP addresses
from anywhere on the LAN, WAN, or Internet. The location of the connecting computer is
irrelevent.
• Remote users log in using a browser or stand-alone Windows or Java GUI applications. Java
allows the switches to work with JRE (Java Runtime Environment) enabled operating systems,
ensuring multi-platform operability.
• The client software allows operators to exchange keyboard, video and mouse signals with the
servers attached to the switches just as if they were working on the equipment directly.
• Up to 32 (KVM2132P) users can share the switch's buses. A Message Board fea ture allows them
to communicate with each other to facilitate port sharing.
• Administrators can perform maintenance tasks from installing and running GUI applications, to
BIOS level troubleshooting, routine monitoring, concurrent maintenance, and system
administration.
• Local console operation is accomplished by entering hotkey combinations from the keyboa rd with
a full screen GUI display.
• The Auto Scan feature permits automatic switching fro m port to port at user-specified intervals,
while the Panel Array Mode can display the video output of up to 42 servers at the same time.
• CAT 5e cable links the switch to the servers. A 16 or 32 port switch can be installed in a 1U rack,
and use the internal network wiring in most modern commercial buildings.
• The switch receives keyboard input directly. There is no software installation.
• Download firmware updates from www.apc.com.
• Adapter ID function stores port information like the adapter ID, OS, keyboard language, adapter
name, operation modes and more. When a KVM Adapter Cable is moved from one port to
another, the switch recognizes the adapter cable at the new location.
• Upgrade the entire installation from a single remote console located anywhere in the world.
• Virtual Media support.
KVM2132P / KVM2116P KVM Switches only
• Dual power is available on KVM2132P and KVM2116P. Power cords plugged into separate power
sources ensure power to the switch if one power sources fails.
• Variable fan speed: changes according to the switches temperature.
• PDU connection port allows administrators to boot or reboot servers.
• Two 10/100/1000 Mbps NICs for redundant LAN or two IP operations.
1 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Safety
Read all of these instructions. Save them for future reference. Follow all warnings and instructions
marked on the device.
DANGER DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC
FLASH
• Avoid circuit overload. Before energizing, review the
electrical specifications in th e product documentation.
• Use only the supplied power cord or a power cord
approved for use in your region.
• The cord must have voltage and current ratings equal to
or greater than those of the product rating label
requirements.
• Plug the power cord into a grounded (earthed) outlet that
is easily accessible. Do not disable the grounding pin.
• Make sure that all equipment, including power strips, is
properly grounded.
• The AC inlet is the main disconnect device for the
product.
• This product has no user-serviceable parts inside. Do not
remove product cover. All repairs should be performed by
authorized personnel only.
Failure to follow these instructions can result in death
or serious injury.
RISQUE DE CHOC ÉLECTRIQUE, D'EXPLOSION OU
D'ÉCLAIR D'ARC ÉLECTRIQUE
• Évitez de surcharger le circuit. Avant de mettre le circuit
sous tension, vérifiez les caractéristiques électriques
indiquées dans la documentation du produit.
• Utilisez uniquement le cordon d’alimentation fourni ou un
cordon d’alimentation homologué dans votre région.
• Le cordon d'alimentation doit supporter une tension et un
courant égaux ou supérieurs aux exigences indiquées sur
l'étiquette des caractéristiques du produit.
• Reliez le cordon d'alimentation à une prise secteur avec
terre facilement accessible. Ne désactivez pas la broche
de terre.
• Assurez-vous que tout l'équipement est correctement relié
à la terre, y compris les rubans d'alimentation.
• La prise d'alimentation c.a. sert de déconnexion principale
du produit.
• Ce produit n'a aucun composant interne réparable par
l'utilisateur. Ne retirez pas le capot du produit. Toute
réparation doit être effectuée uniquement par du personnel
autorisé.
Le non-respect de ces instructions peut entraîner des
blessures graves, voire mortelles.
CAUTIONATTENTION
HAZARD OF EQUIPMENT DAMAGE
• Do not connect the RJ-11 connector marked
"UPGRADE" to any telecommunication network.
• Plugging in devices other than those specified in the
product documentation may result in equipment damage
• Allow sufficient airflow for safe operation. To avoid
overheating, make sure the product enclosure openings
are never blocked or covered. Rack temperature must be
less than 40°C.
• Uneven mechanical loading can create a hazardous
condition.
• Do not use the product as a shelf.
• Use only the installation mounting hardware provided to
avoid damage.
Failure to follow these instructions can result in injury
or equipment damage.
RISQUE D'ENDOMMAGER L'ÉQUIPEMENT
• Ne raccordez le connecteur RJ-11 marqué « UPGRADE »
à aucun réseau de télécommunication.
• La connexion d'appareils autres que ceux indiqués dans la
documentation du produit peut entraîner des dommages à
l'équipement.
• Laissez une circulation d'air suffisante pour garantir un
fonctionnement en toute sécurité. Pour éviter une
surchauffe, assurez-vous que les ouvertures autour du
produit ne soient jamais obstruées ou recouvertes. La
température du rack doit être inférieure à 40 °C.
• Une charge mécanique inégale peut créer une situation
dangereuse.
• Le produit ne doit pas servir d'étagère.
• Utilisez uniquement la quincaillerie de fixation fournie pour
éviter d'endommager l'équipement.
Le non-respect de ces instructions peut entraîner des
blessures ou endommager l'équipement.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 2
NOTICE
• Do not use the device near water, Never spill liquid of any kind on the device.
• Unplug the device from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for
cleaning.
• To help protect your system from sudden, transient increases and decreases in electrical power, use a surge
suppressor, line conditioner, or uninterruptible power supply (UPS).
• Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and that the full
weight of the rack rests on the floor. Install front and side st abilizers on a single rack or front stabilizers for joined multiple
racks before working on the rack.
• Position system cables and power cables carefully; Be sure that nothing rests on any cables.
• Never push objects of any kind into or through cabinet slots. They may touch dangerous voltage points or short out parts
resulting in a risk of fire or electrical shock.
• Always load the rack from the bottom up, and load the heaviest item in the rack first.
• Make sure that the rack is level and stable before extending a device from the rack.
• Use caution when pressing the device rail release latches and sliding a device into or out of a rack; the slide rails can
pinch your fingers.
• After a device is inserted into the rack, carefully extend the rail into a locking position, and then slide the device into the
rack.
• Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not exceed 80
percent of the branch circuit rating.
• Make sure that all equipment used on the rack, including power strips and other electrical connectors, is properly
grounded.
• Ensure that proper airflow is provided to devices in the rack.
• Ensure that the operating ambient temperature of the rack environment does not exceed the maximum ambient
temperature specified for the equipment by the manufacturer
• Do not step on or stand on any device when servicing other devices in a rack.
• Equipment mounted on rails should not act as shelf or work surface.
• Route the power cord and cables so that they cannot be stepped on or tripped over.
AVIS
• Ne pas utiliser l'appareil près de l'eau, jamais de liquide d'aucune sorte sur l'appareil.
• Débranchez l'appareil de la prise murale avant de le nettoyer. Ne pas utiliser de nettoyants liquides ou en aérosol.
Utilisez un chiffon humide pour le nettoyage.
• Pour aider à protéger votre système contre les augmentations soudaines et transitoires et des diminutions de puissance
électrique, utilisez un limiteur de surtension, un conditionneur de ligne ou d'alimentation sans coupure (UPS).
• Avant de travailler sur le rack, assurez-vous que les stabilisateurs sont fixés au rack, étendu sur le sol, et que le poids
du rack repose sur le sol. Installez les stabilisateurs avant et latéraux d'un seul rack ou les stabilisateurs avant de
plusieurs racks joints avant de travailler sur le rack.
• Câbles du système de positionnement et de câbles électriques attentivement; Assurez-vous que rien ne repose sur les
câbles.
• Ne poussez jamais d'objets d' au cu n e so rte dans ou à travers les fentes du boîtier. Ils peuvent toucher des points de
tension dangereux ou court-circuiter résultant en un risque d'incendie ou de choc électrique.
• Chargez toujours le rack de bas en haut, et charger l'élément le plus lourd dans le rack en premier.
• Assurez-vous que le support est de niveau et stable avant d'étendre un dispositif de l'armoire.
• Faites preuve de prudence lorsque vous appuyez sur de dégagement des rails de dispositif verrous et glissant un
dispositif dans ou hors d'un rack; les glissières peuvent vous pincer les doigts.
• Après un dispositif est inséré dans le rack, étendez le rail avec précaution dans une position de verrouillage, puis faites
glisser l'appareil dans le rack.
• Ne surchargez pas le circuit de dérivation CA qui alimente le rack. La charge totale du rack ne doit pas dépasser 80
pour cent de la capacité du circuit de dé ri va ti on .
• Assurez-vous que tout le matériel utilisé sur le support, y compris les rampes d'alimentation et d'autres connecteurs
électriques, est correctement mis à la terre.
• Assurez-vous que la circulation d'air adéquate est fournie aux dispositifs du rack.
• S'assurer que la température ambiante de fonctionnement de l'environnement de l'armoir e ne dépasse pas la
température ambiante maximale prévue pour l'équipement par le fabricant
• Ne pas marcher ou se tenir debout sur n'importe quel appareil lors de l'entretien d'autres appareils dans un rack.
• Le cordon d'alimentation et les câbles de sorte qu'ils ne peuvent pas être piétiné ou trébucher dessus.
• Les équipements montés sur rails/glissières ne doivent pas faire office d’étagère ou de surface de travail.
3 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Taking Delivery
Examine the components at the time of delivery to be sure all parts are present and in good working
order . Anything missing or damaged must be reported immediately to the shipping firm and to APC.
Inventory
The package consists of:
• KVM Switch
• NEMA 5 - 15 power cord
• C13 - C14 power cord
• Rack Mount Bracket
• Serial Adapter (for modem connection)
• KVM Access Management Software USB key (please retain for future license upgrade)
• Literature Kit: Quick Start Guide, Safety Sheet, China ROHS and CD (containing KVM Access
Management software)
System Requirements
Remote User Computers
Remote user computers (also referred to as client compu ters) are computer s logged into the switch from
remote locations over the internet.
These computers must have the following equipment installed:
• At least a PIII 1 GHz processor, with the screen resolution set to 1024 x 768.
• Browsers must support 128 bit SSL encryption.
• A network transfer speed of at least 512kbps.
• For the browser-based WinClient ActiveX Viewer, DirectX 8 must be present, and at least 150MB
of memory must be available after installation.
• For the browser-based Java Applet Viewer the latest version of the Java Runtime Environment
(JRE) must be installed, and at least 205MB of memory must be available after installation.
• For the Windows Client AP, DirectX 8 must be present, and at least 90MB of memory must be
available after installation.
• For the Java Client AP, the latest version of the Java Runtime Environment (JRE) must be
installed, and at least 145MB of memory must be available after installation.
• For the Log Server, you must have the Microsoft Jet OLEDB 4.0 or higher driver installed.
Servers
Servers are the computers connected to the switch by KVM Adapter Cables.
These servers must have the following equipment installed:
• A VGA, SVGA or multisync port
• For USB KVM Adapter Cable Connections: a Type A USB port and USB host controller
• For PS/2 KVM Adapter Cable Connections: 6-pin Mini-DIN keyboard and mouse ports
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 4
Video
Only the following non-interlaced video signals are supported:
ResolutionRefresh Rates
640 x 48060, 70, 72, 75, 85
720 x 40070, 75
800 x 60056, 60, 70, 72, 75, 85
1024 x 76860, 70, 75, 85
1152 x 86460, 70, 75, 85
1152 x 90066, 76
1280 x 102460, 70, 75, 85,
1600 x 120060
KVM Server Modules and cables
NOTE: KVM server modules are also referred to as adapter cables in some dialog boxes..
• Cat5e (or higher) cable connects the switch to the KVM server modules .
• The following KVM server modules and cables are required for use with the switch.
Cable TypePort Type
KVM-PS2Connect to devices with PS/2 ports
KVM-PS2VMConnect to devices with PS/2 ports, virtual media support
KVM-USBConnect to devices with USB ports
KVM-USBVMConnect to devices with USB ports, virtual media support
KVM-USBVMCACConnect to devices with USB ports, virtual media and smart card/CAC support
KVM-SERIALConnect to serial based devices
AP5641 (Optional) Connect a rack PDU to the KVM
Supported Operating Systems
• Microsoft Windows
• Linux
• UNIX
• Mac
• DOS
Browsers
Supported browsers for remote users:
BrowserVersion
IE6 and higher,
Chrome8.0 and higher
FirefoxWindows3.5 and higher
Linux3.0 and higher
SafariWindows4.0 and higher
Mac3.1 and higher
Opera10.0 and higher
MozillaWindows1.7 and higher
Sun1.7 and higher
Netscape9.0 and higher
5 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Max Server connections
Parent
KVM Model
KVM2132P32KVM0216A *1632 x 16 x 16 = 819216 x 8 x 16 = 20483
KVM2116P 16KVM0216A *1616 x 16 x 16 = 40968 x 8 x 16 = 10243
KVM1116P16KVM0116A *1616 x 16 = 2562
KVM1116P16KVM0108A *816 x 8 =1282
* Not covered in this manual. See the User Guides for these models for more information.
PortsChild
Tiered KVM
PortsServers in a Single
Level Tier
Servers in a Two
Level Tier
Maximum
Levels
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 6
Components
aem0371a
Reset
Power
1 2 3 4 5 6 7 8 9 10111213141516
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Lan 1
Lan 2
Reset
Power
1 2 3 4 5 6 7 8 9 10111213141516
Lan 1
Lan 2
Reset
Power
1 2 3 4 5 6 7 8 9 10111213141516
Lan 1
KVM2132P
KVM2116P
KVM1116P
Front
Item NameDescription
1Power LEDIlluminated when the unit is powered up and ready to operate.
2Port LEDsProvides status information about corresponding KVM Ports.
• GREEN: The computer attached to the port is On Line.
• RED: The computer attached to the port is Selected (has KVM focus).
• GREEN + RED (ORANGE): The computer attached to the port is On Line and Selected.
The LEDs are continuously ON under normal conditions. An LED flashes at half second intervals
when its corresponding port is accessed under Auto Scan Mode or Skip Mode.
3LAN LEDsPrimary and Secondary 10/100/1000 Mbps LAN LEDs.
•RED: 10 Mbps
4Reset Switch Use a small object like a paper clip or ballpoint pen to press the reset switch.
• RED + GREEN (ORANGE): 100 Mbps
• GREEN: 1000 Mbps
Flashes to indicate that the switch is being accessed.
• To perform a system reset, press and release when the unit is running.
• To reset to the factory default settings, press and hold for +3 seconds when the unit is running.NOTE: This does not clear User Account information. See “Factory Default Settings” on
page 104, for information on clearing user account information.
• To return to factory default firmware settings, rather than any upgraded version press and hold
while powering on the unit. This allows recovery from a failed firmware upgrade so the upgrade
may be tried again.NOTE: This operation is only performed after a firmware upgrade failure that results in the device
becoming inoperable.
5Console Port A Rack LCD Console may be installed in this port.
6 USB Ports• Connect USB storage peripherals (CD/DVD, HD, flash drives, etc.).
• A USB keyboard and mouse can be used in place of, or in addition to, a keyboard and mouse
plugged in on the rear panel.
7 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Rear
aem0370a
KVM2132P
KVM2116P
KVM1116P
Item NameDescription
1Power Socket 1Plug power cable for Power Source 1 in here.
2Power Socket 2Plug power cable for Power Source 2 in here.
3LAN Port(s) Connect the unit to the network interface (10/100/1000 Mbps) here
4PDU Port(s) Connect to a PDU unit (which allows se rvers attached to the KVM switch to be booted
remotely over the net).
5Local Console Port(s)Local console devices (keyboard, monitor and mouse), plug in here. Any combination
of USB and PS/2 keyboards and mice can be used.
6KVM Ports Cat 5e cables plug in to link the unit to the KVM Adapter Cables, which connect to the
servers.
7Modem PortDial in connection if th e unit becomes unavailable over the network.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 8
Installation
Overview
KVM Adapter Cables connect the switch to the connected devices. A separate KVM Adapter Cable is
required for each server or device connection. See the list of KVM Adapter Cables on page 5 or contact
Schneider Electric Customer Support for help.
NOTE: 1. Refer to the Safety section of this manual before installing the KVM switch.
2. Power to any device that will be connected to the installation must be turned off. Unplug the
power cords of any computers that have the Keyboard Power On function.
Rack Mounting
The switch can be mounted in a 19" (1U) rack. The mounting brackets can screw into either the front or
the back of the unit so that it can attach to the front or the back of the rack.
NOTE: Use cage nuts (not provided) for racks that are not pre-threaded.
Rack Mounting - Front
1. Position the switch in the front of the rack.
Align the mounting bracket holes with the
holes in the rack.
2. Secure the mounting brackets to the rack.
aem0372a
9 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Rack Mounting - Rear
1. Remove the brackets from the front of the
KVM switch.
Remove the plug from the alignment hole.
2. Install the smaller bracket from the front of
the unit to the back. Install the rack mounting
bracket from the inventory to the rear of the
unit.
3. Slide the switch into the rack. Align the
mounting bracket holes with the holes in the
rack.
4. Secure the mounting brackets to the rear of
the rack.
aem0449a
aem0450a
Optional KVM to LCD Console Mounting
The KVM switch can be mounted to a Rack LCD Console (not included). See the installation sheet for
the Rack LCD Console KVM switch bracket kit for more information.
Single Level Installation
In a single level installation, no additional switches are tiered from the original switch.
1. Plug the keyboard, monitor, and mouse of your Local Console into the Console Ports of the KVM
parent switch. Each port is color coded and marked with an appropriate icon.
NOTE: 1. Any combination of keyboard and mouse connections can be used.
2. USB keyboards and mice can be plugged into the USB ports on the front panel or
into the console ports on the back.
2. Use Cat 5e cable to conn ect a KVM port to a KVM server module appropr iate for the server being
installed.
3. Plug the connectors on the KVM server module into the appropriate server ports.
4. Plug a cable from the LAN or WAN into the KVM switch's primary network interface socket.
5. (Optional) Plug another cable from the LAN or WAN into the KVM switch's backup (secondary)
network interface socket.
6. (Optional) Use Cat 5e cable to connect the switch's Modem port to an SA0142 Serial Adapter.
Connect the Adapter's serial connector to the modem's DB-9 port.
7. Plug the supplied power cord(s) into the switch's power socket(s), then into an AC power source.
8. Turn on the servers.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 10
KVM1116P Single Level Installation Diagram
aem0448a
11 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
KVM2132P Single Level Installation Diagram
aem0379a
LAN 2
PDU 2
LAN 1 PDU 1
LAN/
Internet
LAN/
Internet
Remote
Console
Remote
Console
OR
KVM2132A
NOTE: KVM2116P Single Level Installation is the same except for the number of KVM ports.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 12
Tiering Multiple KVM Switches
aem0376a
KVM1116P
KVM0116A *
KVM-PS2
A tiered installation will greatly expand the number of servers that can be added to the installation.
Cascaded tiering adds capacity to a KVM installation, but the parent loses at least one KVM p ort for each
tiered KVM switch. KVM2132P, and KVM2116P support tiering up to 3 levels. When the KVM consoles
of the first-level KVM switch invoke the OSD, all computers on the tiered KVM installation are listed in the
port directory.
KVM1116P Two Level Installation
Up to 16 additional KVM switches can be tiered from the KVM port s of the origin al KVM switch. As many
as 256 servers can be controlled in a complete two level installation. In a tiered installation, the
(KVM1116P) switch is considered the First Level or Parent unit, the tiered switches are considered
Second Level or Child units (KVM0116A / KVM0108A). Turn off power to all the devices, including all
pre-existing devices on the installation.
1. Use Cat 5e cable to connect any available KVM Port on the First Level unit (KVM1116P) to a
KVM-PS2 Adapter Cable.
2. Plug the adapter cable's KVM connectors to the Keyboard, Vide o, and Mouse Console ports of
the Second Level switch (KVM0116A / KVM0108A).
3. Connect any available KVM port on the Second Level unit to the Keyboard, Video, and Mouse
ports of the server.
4. Power on the First Level switch, then power on the Second Level switches .
5. Turn the servers on last.
Two Level Installation Diagram
* See the User Guide for KVM0116A and KVM0108A for more information about this unit.
13 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Three Level Installation and (1 or 2) Bus Configurations
KVM2132P (or KVM2116P)
KVM0216A *
aem0380a
KVM0216A *
In tiered installations, the number of bus connection s between a paren t and child KVM switch determines
the number of users that can simultaneously a ccess the KVM port s of a child switch. A bu s connection is
established by connecting a KVM port on the parent switch to a LAN port on the child switch. The KVM
switch KVM2132P (or KVM2116P) supports a maximum of two bus connections for each tiered switch.
In a two-bus tiered configuration, two bus connections between every parent switch and child switch in
the installation are created so both KVM consoles on the first-level KVM switch can access the KVM
ports of any tiered switches at the same time. Console connectors of the child switches ar e inoperable.
In a one-bus tiered configuration only a single bus connection is created between a parent switch and a
child switch. Only one of the consoles connected to the p arent switch h as access to a child switch at any
time. The second console can still control and access the port s of the par ent switch. Only one console of
each child switch is available to access the KVM ports on the same level or lower level switch. KVM
consoles connected to tiered switches cannot access the ports of a parent switch and can perform only
port switching and user profile changes. No other administrative functions can be executed.
KVM2132P / KVM2116P Two Bus Tiered Diagram
* See the User Guide for KVM0216A for more information about this KVM switch.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 14
KVM1116P One Bus Tiered Diagram
aem0376a
KVM1116P
KVM0116A *
KVM-PS2
* See the User Guide for KVM0116A and KVM0108A for more information about these KVM switches.
Supported KVM Switches
KVM switches that can be used in a tiered installation:
• KVM2132P / KVM2116P
– KVM0216A
• KVM1116P
– KVM0108A / KVM0116A
NOTE:
functionality of the tiered KVM switch. (For example, KVM0108A / KVM0116A switches do not
support virtual media.)
Some of the KVM switch's features may not be supported, depending on the
Hardware Setup
Cable Length Considerations
NOTE: KVM server modules are also referred to as KVM adapter cables.
• Do not exceed 66 feet (20m) between the switch and the local monitor.
• The distance between the First Level (Parent) KVM switch an d the Second Level (Child) KVM
switch must not exceed 93 feet (30m).
• To support a resolution of 1280x1024, the recommended maximum distance between the KVM
switch and the KVM server module is 164 feet (50m).
• The total distance between any KVM switch and any KVM server module in the installation cannot
Hot Plugging
exceed 164 feet (50m).
The KVM switch supports hot plugging. Components can be removed and added by unplugging and replugging cables from the ports without shutting the unit down.
NOTE: The Operating System of the server must support hot plugging for this function to work properly.
15 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
The Adapter ID Function
Server module information (the Adapter ID, port name, OS, keyboard language, and access mode) is
stored on the server module. The switch's Adapter ID function stores this information along with the
server module's configuration information (access rights, etc.), so that when a server is moved with its
server module from one port to another, its settings do not have to be reconfigured. The Adapter ID
function restores them at the new location. Only the port number changes.
When moving the server and server module cable to another switch, only the information that is stored
on the server module is retained. Other settings must be reconfigured, or the Backup/Restore function
can be used (see page 93).
Port settings are stored with the server module. If a server is moved to a new port without its original
server module, or if a different server is connecte d to the server module, the port settings for the new
server must be manually configured. See “Sidebar Utilities” on page 36 for port configuration details.
Powering Off and Restarting
If the switch is powered off, or if the switch loses power and needs to be restarted, wait 10 seconds
before powering it back on. Servers should not be affected, bu t if any fail, restart them.
Port ID Numbering
Each server on the installation is assigned a unique Port ID.
1. A server attached to a first level KVM switch has a one segment Port ID that corresponds to the
KVM Port number to which it is connected.
2. A server attached to a Second Level KVM switch has a two segment Port ID.
a. The first segment represents the First Level unit’s KVM Port number that connects to the
Second Level KVM unit.
b. The second segment represents the Second Level unit’s KVM Port number that connects
to the server.
Example: A Port ID of 12 - 3 refers to a server connected to KVM Port 3 of a Second Level unit (child)
connected to KVM Port 12 of the First Level unit (parent).
A server attached to a third level KVM switch has a three segment Port ID. Example: 12-03-05.
Port Selection
Port selection is accomplished by means of the GUI. See Port selection details on page 35.
PDU Connection (KVM2132P, KVM2116P)
• Connect the PDU and KVM switch with connection cable AP5641.
• The RJ12 connector plugs into the PDU port labeled “Serial”.
• The RJ45 connector plugs into the KVM port labeled “PDU1” or “PDU2”.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 16
Super Administrator Setup
Overview
First Time Setup
The Super Administrator sets up the unit for user operation (set the network parameters, change the
default Super Administrator login) for the first time from the local console if possible. See “IP Address
Determination” on page 106 to set up remotely.
Since this is the first time you are logging in, use the default Username “apc” and Password “apc”. The
Local Console Main Page will open following a successful login.
NOTE: For security purposes, changing to a unique Username and Password is recommended.
Network Setup
1. Click the Device Management tab.
2. Select the Network tab.
3. Fill in the fields according to the information provided under Network, page 68.
Changing the Super Administrator Login
1. At the top of the screen, click the User tab.
The page lists Users and Groups in the Sidebar at the left, and more details in the center panel.
The first time the page is accessed, only the Super Administrator appears.
17 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
2. Click on Administrator in the left panel or select Administrator in the central panel.
Click Modify at the bottom of the page to open the User Information page.
3. Change the Username and Password.
4. Enter the ne w password again in the Confirm Password field and click Save.
5. Click OK in the dialog box that says the change completed successfu lly.
6. Click on another item on the Local Console Main Page, to close the User Information page.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 18
Logging In
Overview
Switches can be accessed from a local console, an internet browser, a Windows application (AP)
program, and a Java application (AP) program.
The switch's authentication procedure requires a va lid username and p assword. Invalid login i nformation
will open an Invalid Username or Password, or Login Failed message.
NOTE: If the login fails, log in again with a correct username and password. If the number of invalid
login attempts exceeds a specified amount, a timeout period is invoked. The timeout period must expire
before another login is attempted. See Login Failures, page 75.
Local Console Login
Enter your Username and Password, then click Login to open the Local Console Main Page. The Local
Console Main Page is similar to the Web Browser, WinClient and Java Client Main Pages. For a
description of the Web Browser Main Page, see page 21.
Browser Login
The switch can be accessed from an Internet browser running on any platform.
1. Specif y the IP address of the switch you want to access in the browser's address bar.
NOTE:
and the login string along with the IP address when you log in.
2. When a Security Alert dialog box opens, accept the certificate. It can be trusted. If a second
certificate appears, accept it as well to open the login page.
3. Provide your username and password and click Login to open the Web Main Page.
If the administrator added a login string for security purposes, include a forward slas h
Windows Client AP Login
The Windows AP Client allows direct remote access to Windows systems users, without going through a
browser although initially the Windows AP Client program must be downloaded from the browser page.
Double-click the WinClient.exe icon to open the Windows Client Connection Screen:
The Windows Client AP Connection Screen
ItemDescription
Menu BarThe Menu Bar contains two items: File and Help.
• The File Menu allows the operator to Create, Save, and Open user created Work files.
• The Help Menu displays the WinClient AP version.
Server ListWinClient.exe searches the user's local LAN segment for switches, and lists them in this
box. Double-click to connect to one of these units.NOTE: 1. The switch’s Enable Device List configuration parameter must be enabled.
2. Units in the Server List are those whose Access Port settings match the number
specified for Port in the Server area of this dialog box.
ServerUsed when connecting to a switch at a remote location. Select an address from the IP list
box. If the address isn't listed, enter the target IP address in the IP field, and its port
number in the Port field. If you don't know the port number, contact your Administrator.
• When the IP address and Port number have been specified, click Connect.
• When finished, return to this dialog box and click Disconnect to end the connection.
Message PanelLists status messages regarding the connection to the switch.
Switch to Remote View Click to switch to the GUI Main Page (page 23).
19 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Connect using Windows Client AP
1. Select the device from the Server List box and double-click on it or specify its IP address and port
number in the Server IP and Port input boxes.
2. Click Connect to open the Login dialog box.
3. Enter a valid Username and Password, and click OK.
4. Following authentication, the Switch to Remote View button becomes active. Click it to connect
to the switch and bring up its GUI Main Page.
The File Menu
Create, Save, and Open user created Work files. A Work File consists of all the information specified in a
Client session including the Server List, Server IP list items, and Hotkey settings. The Client program
opens with the values contained in the current work file. The current work file consists of the values that
were in effect the last time the program was closed.
NewCreate a named work file so its values will not be lost, and it will be available for future recall.
OpenOpen a previously saved work file and use the values contained in it.
SaveSave the values presently in effect as the current work file.
ExitExits the WinClient.
Java Client AP Login
The Java AP Client provides direct remote access to non-Windows systems users although the Java AP
Client program is initially downloaded from the browser page. Double-click the JavaClient.jar icon to
open the Java Client Connection Screen.
ItemDescription
Server List JavaClient.jar searches the user's local LAN segment for KVM switches, and lists them in
this box. Double-click to connect to one of these units. NOTE: 1. The switch’s Enable Device List configuration parameter must be enabled.
2. Units in the Server List are those whose Access Port settings match the number
ServerUsed when connecting to a switch at a remote location. Select an address from the IP list
box. If the address isn't listed, enter the target IP address in the IP field, and its port
number in the Port field. If you don't know the port number, contact your Administrator.
• When the IP address and Port number have been specified, click Connect.
• When finished, return to this dialog box and click Disconnect to end the connection.
Message PanelLists status messages regarding the connection to the switch.
Switch to Remote View Click this button to switch to the GUI Main Page.
Connect using - Java Client AP
To connect to a KVM switch:
1. Select the device from the Server List box and double-click on it or specify its IP address and port
number in the Server IP and Port input boxes.
2. Click Connect to open the Login dialog box.
3. Enter a valid Username and Password, and click OK.
4. Following authentication, the Switch to Remote View button becomes active. Click it to connect
to the switch and open its GUI Main Page.
specified for Port in the Server area of this dialog box.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 20
The User Interface
Overview
The look of the user interface Main Page varies depending on the method used to log in.
The Web Browser Main Page
Access the KVM switches with most standard web browsers. Once users log in and are authenticated,
the Web Browser Main Page opens with the Port Access page displayed.
NOTE: Depending on a user's type and permissions, not all elements appear.
ItemDescription
Tab BarContains the KVM switch's main operation categories. Items appearing in the tab bar are
determined by user type, and authorization options.
Menu BarContains operational sub-categories related to the selected item in the tab bar. Items in the
menu bar are determined by user type, and authorization options.
SidebarProvides a tree view listing of ports related to the tab bar and menu bar selections. Click an
item in the Sidebar to open a detail page. Expand or narrow the scope of the ports that
appear in the tree by clicking the Filter button at the bottom of the Sidebar. See the Filter
function on page 38 for details.
AboutProvides information regard ing the switch's current firmware version.
LogoutClick this button to log out of your KVM switch session.
Welcome MessageIf enabled (see Welcome Message*, page 112), a welcome message displays here.
Interactive Display PanelThe main work area. The screens reflect menu choices and Sidebar item selection.
21 KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
The Tab Bar
The number and type of icons that appear on the Tab Bar at the top of the page are determined by user
type (Super Administrator, Administrator, User ) and permissions.
IconDescription
Port Access: The Port Access page is used to access and control the devices on the KVM switch
installation. This page is available to all users.
Create and manage Users and Groups, also assign devices to them. This tab is available to the Super
Administrator, administrators, and users who have User Management permission. The tab does not
appear for other administrators and users.
Configure and control the overall operation of the KVM switch. This page is available to the Super
Administrator, administrators, and users who have Device Management permission. The tab doesn't
appear for other administrators and users.
Displays the contents of the log file.
Install new firmware; backup and restore configuration and account information; ping network devices;
and restore default values. This page is available to the Super Administrator (and Administrators and
Users with Maintenance permission). The icon doesn't display on the page of ordinary administrators
and users.
Download AP versions of the Windows Client, the Java Client, and the Log Server. This page is
available to all users. The programs that can be downloaded depend on the user's permissions.
There are two small icons at the extreme right of the page.
Icon Description
Click the About icon to see information about the KVM switch firmware version.
Click the Logout icon to log out and end your KVM switch session.
KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual 22
Loading...
+ 100 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.