Schneider Electric IT Corporation Legal
Disclaimer
The information presented in this manual is not warranted by the Schneider
Electric IT Corporation to be authoritative, error free, or complete. This
publication is not meant to be a substitute for a detailed operational and site
specific development plan. Therefore, Schneider Electric IT Corporation
assumes no liability for damages, violations of codes, improper installation,
system failures, or any other problems that could arise based on the use of
this Publication.
The information contained in this Publication is provided as is and has been
prepared solely for the purpose of evaluating data center design and
construction. This Publication has been compiled in good faith by Schneider
Electric IT Corporation. However, no representation is made or warranty
given, either express or implied, as to the completeness or accuracy of the
information this Publication contains.
IN NO EVENT SHALL SCHNEIDER ELECTRIC IT CORPORATION, OR
ANY PARENT, AFFILIATE OR SUBSIDIARY COMPANY OF SCHNEIDER
ELECTRIC IT CORPORATION OR THEIR RESPECTIVE OFFICERS,
DIRECTORS, OR EMPLOYEES BE LIABLE FOR ANY DIRECT,
INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL, OR INCIDENTAL
DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS
OF BUSINESS, CONTRACT, REVENUE, DATA, INFORMATION, OR
BUSINESS INTERRUPTION) RESULTING FROM, ARISING OUT, OR IN
CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS
PUBLICATION OR THE CONTENT, EVEN IF SCHNEIDER ELECTRIC IT
CORPORATION HAS BEEN EXPRESSLY ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. SCHNEIDER ELECTRIC IT
CORPORATION RESERVES THE RIGHT TO MAKE CHANGES OR
UPDATES WITH RESPECT TO OR IN THE CONTENT OF THE
PUBLICATION OR THE FORMAT THEREOF AT ANY TIME WITHOUT
NOTICE.
Copyright, intellectual, and all other proprietary rights in the content
(including but not limited to software, audio, video, text, and photographs)
rests with Schneider Electric IT Corporation or its licensors. All rights in the
content not expressly granted herein are reserved. No rights of any kind are
licensed or assigned or shall otherwise pass to persons accessing this
information.
This Publication shall not be for resale in whole or in part.
Read the instructions carefully to become familiar with the equipment before trying to
install, operate, service, or maintain it. The following special messages may appear
throughout this manual or on the equipment to warn of potential hazards or to call
attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Danger or Warning safety label indicates
that an electrical hazard exists which will result in personal injury if the
instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided,
can result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can
result in minor or moderate injury.
NOTICE
NOTICE addresses practices not related to physical injury including certain
environmental hazards, potential damage or loss of data.
1
Installation Manual
Safety Information for the Network Management Card 4
The Network Management Card (NMC) contains a removable battery. If this battery
is ingested, seek immediate medical attention.
WARNING
HAZARD OF INTERNAL BURNS
•Do not ingest the battery.
•Keep batteries out of reach of children.
Failure to follow these instructions can result in serious injury or
death.
NOTE: Secure the NMC to the UPS device’s SmartSlot using screws to keep the
battery out of reach.
Installation Manual
2
Preliminary Information
Features
The Schneider Electric UPS Network Management Card (AP9644)
discussed in this document is a Web-based product. Devices with the
NMC installed can be managed using multiple open standards such as:
Hypertext Transfer Protocol (HTTP) Secure SHell (SSH)
Simple Network Management
Protocol versions 1, 2c and 3
File Transfer Protocol (FTP)
SyslogModbus
NOTE: Only HTTPS and SSH are enabled by default.
The AP9644 Network Management Card:
•Provides event logs.
•Enables you to set up notifications through event logging, e-mail, Syslog and
SNMP traps.
•Provides support for PowerChute
•Supports using a Dynamic Host Configuration Protocol (DHCP) or
BOOTstrap Protocol (BOOTP) server to provide the network (TCP/IP) values
of the NMC.
•Provides a selection of security protocols for authentication and encryption.
•Communicates with EcoStruxure IT and StruxureWare Data Center Expert.
•Supports Modbus TCP/IP, and Modbus RTU. For information on how to
configure Modbus RTU, refer to the Modbus Documentation Addendum.
•Supports one universal input/output port, to which you can connect a
temperature (AP9335T) or temperature/humidity sensor (AP9335TH).
Hypertext Transfer Protocol over
Secure Sockets Layer (HTTPS)
Secure File Transfer Protocol
(SFTP)
®
Network Shutdown.
Supported Devices
The Network Management Card 4 is compatible with 3-phase Galaxy VS UPS
devices.