Keypad Programming Instructions

for the Profile Series LK and v.G1 Locks

© SARGENT Manufacturing Company

A7716B

www.sargentlock.com

Table of Contents

Page

1

 

 

 

Transaction Log for LK

4

2

 

G1-LU, G1-PA, G1-PK, G1-TU, G1-TA, G1-TP Programming 5-8

3

 

G1-PA and G1-TA Programming

8

4

 

Chain Programming

9

5

 

Log Sheet for Keypad Programming

Back Cover

6

© SARGENT Manufacturing Company

For installation assistance, contact SARGENT at 800-810-WIRE (9473)

Keypad Programming Instructions for the Profile Series LK and v. G1 Locks

Keypad Lock can support 100 (LK) / 2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) users. user is assigned a User Number in addition to the code used for entry.

. G1:

USER TYPE

USER NUMBER

Master

01

 

 

Supervisor

02

 

 

 

 

Standard

04-97 (LK) 04-2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA)

SofLink™ Plus applications software must be used with (G1-PA & G1-TA) controller for programming

The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is also used for programming. Users are deleted through the Master Programming Code only

Emergency code is a 10 second unlock time and will override a thrown deadbolt on a mortise lock

The Supervisory Code is always User “02”. The Supervisory Code allows temporary lock out of selected users, changes duration of unlock time, requests infrared interrogation output, and may add additional User Codes

For LK

Emergency Code is at User location “02”

 

The Supervisory Code is at User location “03”

The User Codes are entered at user location “04” or higher. User numbers do not have to be used or entered sequentially

The “Lock Out” user is location dependent. To ensure that all users are locked out of the keypad, program this user at location "04"

The “Passage” user has precedence over all users except the “Panic” user. The lock must be toggled back into a locked state for other users to function

Programming:

Lock Controller is preset at the factory with Master Code “1234”.

1234 * will unlock the lock allowing the lever handle to retract the latchbolt.

Set-Up Procedures:

The following are typical procedures to be used when setting up your Profile Series v. G1 lock

If a mistake is made during any of the procedures, depress the “*” key several times until the yellow LED goes out

If no keystroke is made in a 30 sec. timeframe, the programming up to that point will default and you will have to start over

1

To determine programming steps for your lock:

+

-

LK

-

+

 

+-

+-

- +

+-

If your label has an LK, use the programming below.

If your label has a G1-LU, G1-PK, G1-PA, G1-TU, G1-TP or G1-TA, turn to programming in Section 3.

Change the Master Code

99# 1234*

Yellow LED blinks

50# 1#

Yellow LED blinks

New Master Code*

Yellow LED blinks quickly

New Master Code*

Yellow LED blinks slowly

*

Yellow LED goes out (If solid, see note)

This example uses the Factory Default 1234*

It is recommended not to use the factory default master code.

© SARGENT Manufacturing Company

For installation assistance, contact SARGENT at 800-810-WIRE (9473)

1

Keypad Programming Instructions for the Profile Series LK Lock

To Enter the Emergency Code

99# Master Code*

Yellow LED blinks

50# 02#

Yellow LED blinks

Emergency (1-6 digits)*

Yellow LED blinks quickly

Emergency (1-6 digits)*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock.

• Factory Emergency Code is 4321

To Enter or Change the Supervisor Code

99# Master Code*

Yellow LED blinks

50# 1# 03#

Yellow LED blinks

Supervisory (1-6 digits)*

Yellow LED blinks quickly

Supervisory (1-6 digits)*

Yellow LED blinks Slowly (If solid, see note)

*

Yellow LED goes out

Enter A User Code

99# Master Code* or Supervisory Code* 50# 1# (User Number 04-100)#

User Code (1-6 digits)* User Code (1-6 digits)*

*

Yellow LED blinks Yellow LED blinks

Yellow LED blinks quickly

Yellow LED blinks slowly (If solid, see note) Yellow LED goes out

Enter A Passage (Maintained) Code

99# Master Code*

Yellow LED blinks

50# 0# (User Number 04-100)#

Yellow LED blinks

User Code (1-6 digits)*

Yellow LED blinks quickly

User Code (1-6 digits)*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Enter A One Time User Code

99# Master Code* or Supervisory Code* 50# 5# (User Number 04-100)#

User Code (1-6 digits)* User Code (1-6 digits)*

*

Yellow LED blinks Yellow LED blinks

Yellow LED blinks quickly

Yellow LED blinks slowly (If solid, see note) Yellow LED goes out

To Deactivate/Reactivate “Beep” With Key Stroke

99# Supervisory or Master Code*

Yellow LED blinks

30# 0# 0# (Off) (1# = On)

Yellow LED blinks

*

Yellow LED blinks quickly

*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Note: If turning beep off, not audible on last two steps.

To Clear the Entire Memory

99# Master Code*

Yellow LED blinks

46# 00000# 00000#

Yellow LED blinks

*

Yellow LED blinks quickly

*

Yellow LED goes solid and begins to blink

*

Yellow LED goes out (If solid, see note)

This deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234*, Door Number to 0001 and Unlock Time to 5 seconds. If the Master Code is not known, factory assistance will be required to clear the memory. Call 1-800-810-9473.