Keypad Programming Instructions
for the Profile Series LK and v.G1 Locks
© SARGENT Manufacturing Company
A7716B |
www.sargentlock.com |
Table of Contents
Page
1 |
|
|
|
Transaction Log for LK |
4 |
2 |
||
|
G1-LU, G1-PA, G1-PK, G1-TU, G1-TA, G1-TP Programming 5-8 |
|
3 |
||
|
G1-PA and G1-TA Programming |
8 |
4 |
||
|
Chain Programming |
9 |
5 |
||
|
Log Sheet for Keypad Programming |
Back Cover |
6 |
© SARGENT Manufacturing Company
For installation assistance, contact SARGENT at 800-810-WIRE (9473)
Keypad Programming Instructions for the Profile Series LK and v. G1 Locks
Keypad Lock can support 100 (LK) / 2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) users. user is assigned a User Number in addition to the code used for entry.
. G1: |
USER TYPE |
USER NUMBER |
|
Master |
01 |
||
|
|||
|
Supervisor |
02 |
|
|
|
|
|
|
Standard |
04-97 (LK) 04-2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) |
SofLink™ Plus applications software must be used with (G1-PA & G1-TA) controller for programming
The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is also used for programming. Users are deleted through the Master Programming Code only
Emergency code is a 10 second unlock time and will override a thrown deadbolt on a mortise lock
The Supervisory Code is always User “02”. The Supervisory Code allows temporary lock out of selected users, changes duration of unlock time, requests infrared interrogation output, and may add additional User Codes
For LK |
Emergency Code is at User location “02” |
|
The Supervisory Code is at User location “03” |
The User Codes are entered at user location “04” or higher. User numbers do not have to be used or entered sequentially
The “Lock Out” user is location dependent. To ensure that all users are locked out of the keypad, program this user at location "04"
The “Passage” user has precedence over all users except the “Panic” user. The lock must be toggled back into a locked state for other users to function
Programming:
Lock Controller is preset at the factory with Master Code “1234”.
1234 * will unlock the lock allowing the lever handle to retract the latchbolt.
Set-Up Procedures:
The following are typical procedures to be used when setting up your Profile Series v. G1 lock
If a mistake is made during any of the procedures, depress the “*” key several times until the yellow LED goes out
If no keystroke is made in a 30 sec. timeframe, the programming up to that point will default and you will have to start over
1
To determine programming steps for your lock:
+ |
- |
LK |
- |
+ |
|
+-
+-
- +
+-
If your label has an LK, use the programming below.
If your label has a G1-LU, G1-PK, G1-PA, G1-TU, G1-TP or G1-TA, turn to programming in Section 3.
Change the Master Code
99# 1234* |
Yellow LED blinks |
50# 1# |
Yellow LED blinks |
New Master Code* |
Yellow LED blinks quickly |
New Master Code* |
Yellow LED blinks slowly |
* |
Yellow LED goes out (If solid, see note) |
This example uses the Factory Default 1234*
It is recommended not to use the factory default master code.
© SARGENT Manufacturing Company
For installation assistance, contact SARGENT at 800-810-WIRE (9473) |
1 |
Keypad Programming Instructions for the Profile Series LK Lock
To Enter the Emergency Code
99# Master Code* |
Yellow LED blinks |
50# 02# |
Yellow LED blinks |
Emergency (1-6 digits)* |
Yellow LED blinks quickly |
Emergency (1-6 digits)* |
Yellow LED blinks slowly (If solid, see note) |
* |
Yellow LED goes out |
Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock.
• Factory Emergency Code is 4321
To Enter or Change the Supervisor Code
99# Master Code* |
Yellow LED blinks |
50# 1# 03# |
Yellow LED blinks |
Supervisory (1-6 digits)* |
Yellow LED blinks quickly |
Supervisory (1-6 digits)* |
Yellow LED blinks Slowly (If solid, see note) |
* |
Yellow LED goes out |
Enter A User Code
99# Master Code* or Supervisory Code* 50# 1# (User Number 04-100)#
User Code (1-6 digits)* User Code (1-6 digits)*
*
Yellow LED blinks Yellow LED blinks
Yellow LED blinks quickly
Yellow LED blinks slowly (If solid, see note) Yellow LED goes out
Enter A Passage (Maintained) Code
99# Master Code* |
Yellow LED blinks |
50# 0# (User Number 04-100)# |
Yellow LED blinks |
User Code (1-6 digits)* |
Yellow LED blinks quickly |
User Code (1-6 digits)* |
Yellow LED blinks slowly (If solid, see note) |
* |
Yellow LED goes out |
Enter A One Time User Code
99# Master Code* or Supervisory Code* 50# 5# (User Number 04-100)#
User Code (1-6 digits)* User Code (1-6 digits)*
*
Yellow LED blinks Yellow LED blinks
Yellow LED blinks quickly
Yellow LED blinks slowly (If solid, see note) Yellow LED goes out
To Deactivate/Reactivate “Beep” With Key Stroke
99# Supervisory or Master Code* |
Yellow LED blinks |
30# 0# 0# (Off) (1# = On) |
Yellow LED blinks |
* |
Yellow LED blinks quickly |
* |
Yellow LED blinks slowly (If solid, see note) |
* |
Yellow LED goes out |
Note: If turning beep off, not audible on last two steps.
To Clear the Entire Memory
99# Master Code* |
Yellow LED blinks |
46# 00000# 00000# |
Yellow LED blinks |
* |
Yellow LED blinks quickly |
* |
Yellow LED goes solid and begins to blink |
* |
Yellow LED goes out (If solid, see note) |
This deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234*, Door Number to 0001 and Unlock Time to 5 seconds. If the Master Code is not known, factory assistance will be required to clear the memory. Call 1-800-810-9473.
© SARGENT Manufacturing Company
2 |
For installation assistance, contact SARGENT at 800-810-WIRE (9473) |