SARGENT 2408 User Manual

0 (0)
SARGENT 2408 User Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Groupcompany. All

permission of

is prohibited.

A7694C

 

 

 

 

 

 

 

 

 

 

1-7/8" 2" Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

an ASSA ABLOY

rights reserved. Reproduction in whole or in part without the expresswritten

Sargent ManufacturingCompany

 

 

When Conflict with Stop Occurs

 

 

 

 

Recessmortise nut

head as shown

1/8" Max. Frame projection

 

Frame face

 

rTopof

door

 

 

3

 

 

(2) 15/16" Conduit

holes for concealed

 

 

 

 

 

 

 

RELEASE DATE OCT 03 TEMPLATE NO. A7700A

SargentManufacturing Company,

 

 

 

 

 

 

 

Frame

ooD

4"

 

Glass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-1/8"

 

 

 

 

12-2468 Closer-Holder withSmoke

Detector Unit, Pull SideMounting

2008,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

©

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

RecessMortiseHeadsNut

1/8"

5/8"

 

Stop

Door

 

1-9/16"

3-7/8"

 

 

2-3/16"

 

 

wiring

 

 

3/4" Bottom Detailjamb“A”of

 

 

DATA SHEET

Copyright

 

 

 

 

 

 

 

 

 

 

See Detail “A”

 

 

 

 

 

 

 

 

 

 

or

 

 

1-3/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of

door

 

 

 

 

 

Wood screws

24-#12x 2-1/4" Flat head

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2"

 

 

 

 

 

 

machinescrews

 

 

 

 

 

 

 

 

 

 

 

 

 

341/8"-

 

25-5/8"

29"

 

21-3/8"

4-3/4" 13-3/4"

(4) #12-24 x 2-1/2"

Flat head

machine screws

Track Assembly

351 Door Closer Bottom

 

 

2-1/2"

 

2"

4-11/16"

 

(4)#123"x

swing

clear and offset pivots

 

1. Reinforce metal doors and frames per ANSI A250.8 &100,SDI-

 

2. Right hand door shown, left hand opposite.

3. For narrow rail doors (minimum 2-1/8"), use 351-A dropplate;

 

 

 

 

 

 

 

 

 

 

 

 

 

2" 9"

 

Hinge: Butts,

 

12 gauge recommended.

see template A6772.

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

1-1/2" 9/16"

of Jamb

 

C

NOTES

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SARGENT® 12-2468 FIREGUARD® Closer-Holder Device

PULL SIDE INSTALLATIONINSTRUCTIONS

CAUTION: FAILURETO INSTALL OR ADJUSTPROPERLYMAYRESULTIN INJURY OR DAMAGE.

For assistance,contactSARGENT at 800-810-WIRE(9473) or www.sargentlock.com

IMPORTANT NOTE: FireAlarmControlPanelsthat cannotignorea 0.5 secondclosureduringa powercycle,can not be used witha 12Fireguard(smoke detector)product.For moreinformationsee bottomof this page or contactSARGENTTechnicalSupport.

NOTE: AN AUXILIARYDOOR STOP IS REQUIREDATHOLD OPEN

! CAUTION:

1. DISCONNECTALL POWER BEFORE INSTALLATION

2. ALL WIRING TO BE PERFORMEDBY QUALIFIED PERSONNEL TO COMPLYWITH ALL APPLICABLE LOCAL CODES.

Right Hand

3.

MAXIMUM WIRE SIZE IS 18 AWG.

Left Hand

 

 

1

Use enclosed template and drill and tap door and frame for 12-24 machine screws, and prepare hole for conduit. Do not drillthrough

 

channel, as damage willoccurvoidingwarranty.

 

 

2

Install closer body to door with spring power nut away from hinge.

3

To provide clearance for cover, install rubber spacer to

Left hand shown.

mounting plate (frame side) in between conduit openings.

 

 

Spring

 

 

351 Closers are

Power

 

 

Nut

 

Place round

non-handed. RH

 

 

 

 

bumper here

must be on top for

 

 

 

right hand doors.

 

 

 

LH must be on

 

 

frame side of

top for LH doors.

 

 

mounting plate

 

 

 

4

Secure track to frame with electronics away from hinge with screws

4A

For retrofit 2467 installation: Install track using screws

provided. Secure conduit or cable (not supplied) per local codes.

shown. Then mark remaining hole, remove track and drill

 

Wire unit according to wiring shown on page 3.

 

and tap.

Remove knockout piece from cover on side facing frame. Install cover as shown.

5

Use screw and washer to secure main arm to spindle with index mark as shown.

 

 

 

 

 

Closer spindle,

Closer spindle,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Washer and Screw

Washer and Screw

 

 

 

 

 

 

R. H. Door

 

 

 

L. H. Door

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R. H.

L. H.

Hinge

Hinge

 

Positioning of Arm When

Positioning of Arm When

Assembling to Spindle

Assembling to Spindle

Index

! WARNING: !

Index

IF NOT PROPERLYINDEXED,

Markon

Markon

DOOR CLOSER WILL NOT

Spindle

Spindle

45°

FUNCTIONPROPERLY.

45°

 

NOTE: The Smoke Detector on the 12Fireguard product has a momentary contact closure of the Alarm output pins 1 and 2 when incoming power is applied or removed from the Fireguard unit. Conventional FACP’s (Fire Alarm Control Panels) may not have circuitry to compensate for this momentary short of 0.5 seconds or less across pins 1 and 2 and may detect a fault, while Addressable FACP’s have the necessary circuitry to compensate for this. For FACP’s that cannot ignore a 0.5 second closure during a power cycles do not use the 12Fireguard (smoke detector) products.

Contact SARGENT Technical Support for more details.

Copyright © 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All

rights reserved. Reproduction in whole or in part without the express written permission of 1 Sargent Manufacturing Company is prohibited.

A7694C

Loading...
+ 1 hidden pages