The model 7010SB electronic scale is a user friendly ten pound / 5000 gram
scale designed to to assist the operator in calculating the mailing costs of letters
and parcels for selected USPS classes of mail.
UNPACKING YOUR SCALE
Carefully unpack and inspect the shipping container for evidence of shipping
damage. If such evidence is discovered, stop unpacking and immediately notify
the shipper to arrange to have the shipment inspected by an authorized
representative. All damages must be promptly filed with the shipper.
1. Open the box and carefully remove the scale from the shipping carton (save
the shipping carton for future use).
2. Place the scale on a flat level surface free from vibration.
3. Remove the AC adapter and the RS-232 interface cable from the packaging
material.
4. Before using your scale please plug the scale into a power outlet and turn on
the scale for 10 minutes. This will allow the scale to warm-up and ensure
accurate weighing.
INSTALLING THE BATTERY
Use 9V ALKALINE BATTERY ONLY
No other type provides a suitable power output. The manufacturer
recommends Duracell MN1604 or Ever-Ready Gold Seal 6LF22.
To fit the battery, remove the cover on the underside
of the scale and push the connector firmly onto the
battery terminals. Refit the cover.
PN# 7010SB-01 REV. A Page 1 of 7
Page 2
PN# 7010SB-01 REV. A Page 2 of 7
Page 3
SET-UP INSTRUCTIONS
1. Apply power to the scale by first plugging the round connector into the scale
(see below), then plugging the square AC adapter into an outlet.
RS-232 Interface
Connector
2. Select an unused Serial DE-9 Communication Port located on the back of
your PC (COM 1, 2, 3 or 4) and attach the communication cable provided to
your PC. Attach the other end of the communication cable to the 7010SB
scale in the SMALL plug jack located in the rear of the unit. See below:
Rear View
Power Supply
Connector
PN# 7010SB-01 REV. A Page 3 of 7
Page 4
FUNCTION KEYS
The Model 7010SB has three function keys to operate the scale. The
ON(TARE), OFF, and lb-oz/ grams keys.
ON (TARE) KEY:
The ON key performs two functions. First it applies power to the scale; second it
tares the weight on the scale to zero. To use the “tare” feature:
1. Place an empty container on the weighing platform.
2. Press the ON key. Even though the container weight is on the weighing
platform, the scale will display zero weight.
3. When an item is placed on the container, the scale only displays the weight
of the item, not the weight of the container.
4. To reset the scale for no tare, remove the container and its contents from
the weighing platform. Press the OFF key, then the ON key to reset the
scale to zero weight.
(The tare function will work over the full weighing range of the scale but will not
extend the overall capacity of the scale.)
Important Note: It is recommended to press the “OFF key” then the “ON
key” before placing an item on the scale. This will help ensure accurate
weight readings.
OFF KEY:
This key turns off the power to the scale.
LB-OZ/ GRAMS:
The lb-oz grams key is to switch between weighing lb-oz and grams, it is also
used for entering into the calibration mode.
ZERO THE SCALE:
The proper method of zeroing the scale is to press the “OFF” key, then turn the
scale back on by pressing the “ON” key.
SLEEP MODE:
The default setting for sleep mode is Off ( SLP0). If there is no activity, the scale
will turn itself off after 30 seconds The sleep mode can be configured to On
(SLP1) via software.
PN# 7010SB-01 REV. A Page 4 of 7
Page 5
Error Conditions – Shown in the scales display
Below are the error conditions that may appear on the scale display.
“- - - -“ Under Capacity
When the scale weight is below zero the scale will display all dashes (----) and
transmit a status for this condition. This situation will likely occur after the use of
tare when the tare weight is removed. To clear this indication, press the OFF
key, then the ON key and the scale will re-zero.
“Err” Over Capacity -
When the scale is in an overload condition the scale will also display “OvEr” and
transmit a status for this condition. In this case the weight applied to the scale is
above the 10-pound limit; remove the weight from the scale to clear this
indication.
“Lo” Low Battery-
When “Lo” is displayed replace the battery.
ErrL, ErrH, 8888:
The scale is damaged. If within warranty, return the scale to the factory.
TROUBLE SHOOTING
Symptom Recommended Action
Not weighing correctly OR
Inaccurate weight. . . . . . . . . . . . . . . . . Press OFF key, then the ON key
before placing item on the scale.
OR
The scale may need re-calibration. See
calibration instructions.
Weight fluctuates . . . . . . . . . . . . . . . . . . Press OFF key, then the ON key
before placing item on the scale.
OR
Ensure scale is placed in a stable, level
environment.
PN# 7010SB-01 REV. A Page 5 of 7
Page 6
SCALE CALIBRATION INSTRUCTIONS
Periodically your scale may require calibration to ensure proper weighing. You
will need a 10-pound weight to calibrate the scale. Scale calibration is
accomplished, when needed, by the following instructions:
8. Remove the weight from the scale, press the “ON/TARE” key to continue the
normal weighing mode.
* Note: The “Err” displayed after completing calibration
calibration error. Since, the scale only weighs up-to 9 lbs. 15.5 oz., the ten
pounds on the scale causes the displayed message “Err”.
does not indicate a
PN# 7010SB-01 REV. A Page 6 of 7
Page 7
3.9 Sleep Mode Configuration
The sleep mode can be changed, when needed, by the following
instructions:
Function Scale Response
Remove all weight from the scale
Press and hold the “ON/TARE” key and
Press the “OFF” key once to accept the
sleep mode setting and exit .
PN# 7010SB-01 REV. A Page 7 of 7
Page 8
MODEL 7010SB TECHNICAL SPECIFICATIONS
Construction: ABS Plastic
Capacity: 0-5lb. 8oz x 0.1 oz. / 5lb 8oz -9lb x 15.5oz x 0.5oz
0-2500g x 5g / 2501-5000 x 10g (grams Mode)
Accuracy: +/- 2 divisions (0.2oz / 2g)
Display: Large LCD
Unit Size: 8”W x 7.5”L x 2”H
Platter Size: 8”W x 5”L
Keypad: Membrane switch with ON (Tare), OFF and lb-oz / grams
selection.
Power Supply: 120 VAC, 60Hz Ac adapter with 6’ power cord or 9 volt
battery (battery not included)
CLEANING AND CARE
1. Handle the scale with care. Dropping the scale may cause damage to the
loadcell, which will not allow the scale to weigh properly. This type of damage
is considered abuse and violates the product warranty.
2. To avoid damage to the loadcell, never place objects on the scale that exceed
15 pounds.
3. Clean the scale with a slightly damp cloth. DO NOT immerse the scale in
water or use chemical/abrasive-cleaning agents.
4. If the scale is not being used for a long period of time, remove the battery or
turn off the scale.
WARRANTY
This product has a 90-day warranty from the date of delivery against defects in
material and workmanship. This warranty does not apply if the product was
subject to misuse, neglect, damage or abuse.