Salter Brecknell 3700LP User Manual

3700LP Bench Scale Series User’ s Manual
EUROPEAN COUNTRIES
WARNING
This is a Class A product. In a domestic environment this product may cause radio
interference in which the user may be required to take adequate measures.
CAUTION
Risk of electrical shock. Do not remove cover. No user service­able parts inside. Refer servicing to qualified service personnel.
specifications at any time.
10/16/06 3700LP_U.P65 PN 43018-0018C e2 Printed in USA
2
3700LP Bench Scale Series User’s Manual
Table of Contents
Table of Contents .............................................................................. 3
Specifications..................................................................................... 4
Introduction........................................................................................ 5
Unpacking and Setup ........................................................................ 5
Front Panel ........................................................................................ 6
Operation........................................................................................... 6
Performing a Weighment ............................................................. 6
Printout Output ............................................................................. 7
Operation of the Optional Footswitch ........................................... 8
Sleep Mode and Power Down Timer............................................ 8
Battery Information ............................................................................ 9
Maintenance ...................................................................................... 9
RS-232 Protocols............................................................................... 9
RS-232 Protocol Tables ............................................................... 9
Diagnostics Menu ............................................................................ 13
Installing the Display Mounting Bracket........................................... 15
3700LP Bench Scale Series User’s Manual
3
Specifications
Capacity and Dimensions
Construction
Display
Units of measure
Keys
Power
Model Capacity LB (kg) Dimensions Resolution LB (g)
3730LP 10 (5) 10.4” x 10.4” x 2.5” .002 (1) 3730LP 25 (10) 10.4” x 10.4” x 2.5” .005 (2) 3730LP 50 (25) 10.4” x 10.4” x 2.5” .01 (5) 3732LP 100 (50) 14” x 14” x 2.9” .02 (10) 3732LP 250 (100) 14” x 14” x 2.9” .05 (20) 3734LP 100 (50) 18” x 18” x 3.1” .02 (10) 3734LP 250 (100) 18” x 18” x 3.1” .05 (20)
Aluminum base on 10”x10” model or mild steel base on 14”x14” and 18”x18” models. Stainless steel shroud.
Backlit LCD display with six .5” tall digits. Housed in a 6” aluminum alloy extrusion. Display can be attached to base with supplied aluminum display bracket and secured with magnetic strips. Can also be remotely mounted with 7’ of included cable.
lb, kg, g or oz. Front panel switching between units of measure (Note: only two units active at any one time).
Units, Print and Zero. 120 VAC ±10% - 15%, 60 Hz. (UL/CUL)
Internal resolution
Power supply
Overload
Battery recharge time
Output
Operating environment
Agencies
Options
100,000 internal counts of resolution. Internally mounted on models 3732LP and 3734LP. Wall mounted on
model 3730LP. Up to 200% of scale rated capacity. 6 hours when powered down. Bidirectional RS-232 with selectable baud rates from 1200 to 19.2K. 41°F to 104°F (5°C to 40°C). 10 to 95% relative humidity, non-condensing. NTEP C.O.C. # 02-069, CW&M AM#5507 (5000div class III) Factory installed battery: Up to 20 hours of continuous operation with
backlight turned on. When used with the display backlight turned off or in auto mode, battery operation is extended up to 75 hours of operation. Internally mounted, sealed lead acid gel cell battery provides up to 500 discharge/recharge cycles. Battery fully recharges in 6 hours by plugging the scale into an AC outlet. Scale can be used while recharging. (Not available on 3730LP model)
Distributor installed battery kit – (Not available on 3730LP Models) Auto power off – Two power saving modes can be configured to turn the
backlight off or shut down the scale after inactivity to preserve battery life.
Ball top kit – (Not available on 3730LP Models) Display swivel bracket kit 12” pole display kit Footswitch for zero or print (factory installed)– With 4 ft. or 10 ft. long
cable assembly. 230 VAC operation – 230 VAC ±10% - 15%, 50 Hz
4
3700LP Bench Scale Series User’s Manual
Introduction
The 3700LP Series is made up of several sizes and capacities of low profile bench scales. These scales have heavy duty bases, stainless steel, wrap­around shrouds and easy to see and operate display panels that can be mounted on the unit or remotely, by cable. See Specifications for all the options and models which are available.
This manual covers the following:
• Introduction to the 3700LP family
• Unpacking and setup
• Front Panel
• Operation
• Maintenance
Major sections of the manual are separated by black bar headers as seen above (Introduction). Subheadings appear in the left column along with important notes, tips and warnings.
If you have any problems with your scale, contact your local Avery Weigh­Tronix distributor.
Unpacking and Setup
Only plug this unit into a properly grounded, easily accessible outlet of the proper voltage. Injury or damage to the unit may occur if the unit is not properly grounded.
Unpack your 3700 scale and inspect it for shipping damage. Report any damage to your shipping company immediately and save all packing materi­als.
Place the unit on a stable, level surface. Look at the bubble level under the stainless steel shroud as you adjust the threaded feet to level the scale. Tighten the jam nuts up against the scale base once the scale is level.
Plug the display cable into the proper connector on the back of the scale. Plug the power cord into the proper connector on the back of the scale.
If your unit is battery powered, charge the battery for 6 hours and disconnect from the charger before using the scale. Battery life depends on usage of the backlight and other factors.
The 10” x 10” scales do not have the battery option.
If you have a printer or other peripheral device, plug it into the proper connector on the back of the scale.
3700LP Bench Scale Series User’s Manual
5
Front Panel
The front panel consists of the display window, annunciator labels, and three operation keys; PRINT, UNITS, and ZERO. See Figure 1.
Figure 1
Front panel
The display has five LCD weight digits and annunciators. The display is backlit for greater visibility.
The center-of-zero annunciator lights up when the scale is within ¼ graduation of zero.
Operation
Performing a Weighment
The center-of-zero, lb and kg annunciator labels are indicated as active when the annunciators appear to their left in the display window. In Figure 1, the annunciators show the scale is at zero weight and in the lbs unit of measure.
The key functions are listed below: PRINT Press this key to send serial data to a peripheral printer or other
device. If there is motion on the scale, CANT is displayed and no printing will occur.
UNITS Press this key to toggle between available units of measure. If
the scale is configured to limit the scale to just one unit of measure, the display will show CANT if you try to switch the unit of measure.
ZERO Press this key to zero the weight display. If there is motion on
the scale, CANT is displayed and the zero request is ignored.
To perform a weighment, follow these steps:
1. Remove all weight from the scale and press the ZERO key. Display should show 0 weight.
2. Place the item to be weighed on the scale. Display shows the weight.
3. Remove the item and repeat steps 1 and 2 for each item.