Rotel RSP-1066 Service manual

Technical Information
R1
Date: January 1, 2002 Model: RSP 1066 Subject: Software Upgrade
The procedure to upgrade RSP 1066 software is accomplished with the use of the Hyper Terminal computer communications program. Please contact your IT manager if this program is not familiar to you.
Items needed for upgrade:
Computer with serial port connection and AC adaptor
RS 232 cable with DB-9 to RJ-45 terminations (see attached drawing)
Upgrade software from www.Rotel.com
1. Power off the RSP 1066 and all other components in the system
2. Connect the RS 232 cable between the RSP 1066 and the computer
3. Remove the cover plate to reveal the software upgrade switches
4. Set the two software upgrade dip switches to the ON position
5. Launch the HyperTerminal computer program
OTEL OF AMERICA
R
 54 C
ONCORD STREET
ORTH READING
, MA 01864  P
HONE
: 800-370-3741  FAX: 978-664-4109
11/19/02 - Page 2
6. In the Connection Description menu, type RSP 1066, select an icon and click OK
8. In the Connect To menu, select Direct to Comm 1 and click OK
11/19/02 - Page 3
9. In the Comm 1 or 2 Properties menu, select 19200 Bits per second, 8 Data bits, None Parity, 1 Stop bit, None Flow control and click OK
10. In the RSP 1066 Hyper Terminal window, click File and select Properties