Rosemount 708 Specifications

Page 1
Product Data Sheet
February 2017
00813-0100-4708, Rev BD

Rosemount™ 708 Wireless Acoustic Transmitter

Improve energy efficiency and environmental compliance with acoustic monitoring of steam traps and
pressure relief valves
Gain instant visibility to all of your critical steam traps and PRVs through a non-intrusive, WirelessHART
Backed by proven experience in wireless field instrumentation and expert technical support from
Emerson
®
Page 2
Rosemount 708

Emerson’s Wireless Solution

IEC 62591 (WirelessHART)... The industry standard

Self-organizing, adaptive mesh routing
Know you are backed by Emerson’s proven
experience in Wireless field instrumentation and expert technical support
The self-organizing, self-healing network manages
multiple communication paths for any given device. If an obstruction is introduced into the network, data will continue to flow because the device already has other established paths.
Reliable wireless architecture
Standard IEEE 802.15.4 radios
2.4 GHz ISM band sliced into 15 radio-channels
February 2017
Time Synchronized Channel Hopping
Direct sequence spread spectrum (DSSS)
technology delivers high reliability in challenging radio environment

Emerson’s Wireless

Seamless integration to all existing host systems
Native integration into DeltaV
Gateways interface with existing host systems using industry standard protocols including OPC, Modbus
and EtherNet/IP
Layered security keeps your network safe
Ensures data transmissions are received only by the wireless Gateway
Network devices implement industry standard Encryption, Authentication, Verification, Anti-Jamming, and Key Management
Third party security verification including Achilles and FIPS197- User based login and enforced password strength. Password
strength monitoring, user based log in, password reset requirements, automatic lockout, password expiration requirements. Based on guidelines from ISA99.03.03 standard approved level two.
SmartPower™ solutions
and Ovation™ is transparent and seamless
®
TCP/IP, Modbus RTU,
Optimized Emerson instrumentation, both hardware and software, to extend power module life
SmartPower technologies enable predictable power life
Contents
Rosemount 708 Wireless Acoustic Transmitter . . . . . . . 3
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Emerson.com/Rosemount
Page 3
February 2017

Rosemount 708 Wireless Acoustic Transmitter

Ultrasonic acoustic event detection

Reliably detects and transmits information about acoustic events such as leaks
Transmitter output includes acoustic level (0 to 255 counts) and temperature
(–40 to 260 °C)
Transmitter communicates process variable and status information via the wireless
network for integration into existing host systems

Monitor steam traps

Steam Trap Monitoring application provides critical, real-time information on the
condition of your monitored steam trap population
Real-time monitoring provides instantaneous feedback for system maintenance and
optimization
Monitor pressure relief valves or pressure safety
Rosemount 708
valves
Turbulence generated by a leaky valve can be detected using the acoustic transmitter
Notification when release is occurring and when the release has stopped
Emerson Wireless network provides timestamped information to the host
Automated data enables reporting of a tamper-proof data log

Mounting flexibility

The wireless acoustic transmitter can be directly mounted to process piping without
cutting pipes or changing pipe configurations allowing for a flexible, easy installation.

Reliable transmitter performance

The rugged and robust design of the transmitter ensures reliable performance in harsh
environments.
Emerson.com/Rosemount
3
Page 4
Rosemount 708
February 2017

Ordering Information

Table 1. Rosemount Product Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Model Product description
708 Acoustic Transmitter
Output protocol
X Wireless
Measurement
1 Steam Traps with Steam Trap Monitoring Software (order with 7001X)
2 Other measurements
Housing
P Engineered polymer
Waveguide configuration
A1 Acoustic waveguide
Product certifications
NA No hazardous location approval
I1 ATEX Intrinsic Safety
I2 INMETRO Intrinsic Safety
I3 China Intrinsic Safety
I4 TIIS Intrinsic Safety
I5 USA Intrinsically Safe
I6 Canada Intrinsically Safe
I7 IECEx Intrinsic Safety
IM EAC Intrinsically Safe
IP Korea Intrinsically Safe
Mounting hardware
NA00 No mounting hardware
HC01 Stainless steel mounting band, nominal pipe size 1/2- to 21/2-in.
HC02 Stainless steel mounting band, nominal pipe size 3- to 4-in.
HC03 Stainless steel mounting band, nominal pipe size 4- to 10-in.
HT01 High temperature stainless steel mounting hardware, nominal pipe size 1/2- to 11/4-in. (260 to 550 °C)
4
Emerson.com/Rosemount
Page 5
February 2017
Rosemount 708
Table 1. Rosemount Product Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Wireless options (include with selected model number)
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty
Wireless update rate, operating frequency and protocol
WA3 User configurable update rate, 2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni-directional wireless antenna and SmartPower solutions
(1)
WP5 Internal antenna, compatible with green power module (I.S. power module sold separately)
Configuration
C1 Factory configure date, descriptor, message fields and wireless parameters
Typical model number: 708 X 1 P A1 NA HC01 WA3 WP5
1. Power module must be shipped separately, order 701PGNKF.
Table 2. Spare Parts and Accessories
00708-9010-0001 High temperature mounting hardware
Emerson.com/Rosemount
5
Page 6
Rosemount 708

Specifications

February 2017

Functional specifications

Output
IEC 62591 (WirelessHART) 2.4 GHz DSSS
Humidity limits
0–100 percent relative humidity
Tra nsmit rate
User selectable 1 second to 60 minutes
Radio frequency power output from antenna
Internal (WP option) antenna: Maximum of 10 mW (10 dBm) EIRP

Physical specifications

Material selection
Emerson provides a variety of Rosemount products with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for theapplication.Itisthepurchaser’s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product materials, options, and components for the particular application. is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product options, configuration, or materials of construction selected.
Electrical connections/power module
Replaceable, non-rechargeable, Intrinsically Safe
Lithium-Thionyl Chloride power module
Ten-year power module life at reference conditions
Field Communicator connections
Communication Terminals - Clips permanently fixed to power module
(1)
Materials of construction
Housing
PBT/PC
Cover O-ring
Silicone
Power module housing
PBT/PC
Wave guide
Machined 316L SST
Mounting
Transmitters are directly attached to process piping using two stainless steel mounting bands.High temperature mounting hardware should be used when process temperatures exceed 260 °C (500 °F).
Weight
Rosemount 708 with power module –1.31 lb (0.595 kg) Rosemount 708 without power module –0.98 lb (0.445 kg)
Enclosure ratings
®
NEMA
4X and IP66/67

Performance specifications

Vibration effect
Tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10–60 Hz 0.21 mm displacement peak amplitude/60–2000 Hz 3 g).
Temperature limits
Ambient limit: –40 to 85 °C (–40 °F to 185 °F) Storage limit: –40 to 85 °C (–40 °F to 185 °F) Heat from the process is transferred to the transmitter housing. If the process temperature is high, the ambient temperature will need to be lower to account for heat transferred to the transmitter housing. (see Table 3 on page 7)
1. Reference conditions are 70 °F (21 °C), transmit rate of once per minute, and routing data for three additional network devices.
6
Emerson.com/Rosemount
Page 7
February 2017
Rosemount 708
Table 3. Temperature Derating — Direct Mount
Process temperature (°C) Max ambient (°C)
260 41
240 45
220 49
200 53
180 57
160 61
140 64
120 68
100 72
85 75
Table 4. High Temperature — High Temperature Mounting
Option
Process temperature (°C) Max ambient (°C)
550 41
520 45
490 47
460 49
Electro Magnetic Compatibility (EMC)
Meets all relevant requirements of EN 61326-2-3:2013

Wireless output specifications

Acoustic output
0 to 255 counts
Temperature output
–40 to 260 °C (–104 to 500 °F)
430 51
400 53
370 56
340 58
310 60
280 62
260 63
Emerson.com/Rosemount
7
Page 8
Rosemount 708

Product Certifications

Rev 2.1
February 2017

European Union Directive Information

A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at
Emerson.com/Rosemount
.

Telecommunication Compliance

All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification.
Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.

FCC and IC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons.

Ordinary Location Certification

As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

Installing in North America

USA
I5 U.S.A. Intrinsically Safe (IS)
Certificate: (FM) 3043245 Standards: FM Class 3600 – 1998, FM Class 3610 – 2010,
FM Class 3810 – 2005, NEMA 250 – 2003, ANSI/IEC 60529 – 2004
Markings: IS CL I, DIV 1, GP A, B, C, D T4;
CL 1, Zone 0 AEx ia IIC T4; T4(–40 °C ≤ T Rosemount drawing 00708-1000; Type 4X
Special Conditions for Safe Use (X):
1. The Rosemount 708 Wireless Acoustic Transmitter shall only be used with the 701PGNKF Rosemount SmartPower battery pack.
2. Potential Electrostatic charging Hazard – See instructions.
+70 °C) when installed per
a

Canada

I6 Canada Intrinsically Safe
Certificate: (CSA) 2439890 Standards: CAN/CSA C22.2 No. 0-M91,
CAN/CSA C22.2 No. 94-M91, CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No. 157-92, CSA Std C22.2 No. 60529:05
Markings: I.S. CL I, DIV 1, GP A, B, C, D when installed per
Rosemount drawing 00708-1001; T3C; Type 4X

Europe

I1 ATEX Intrinsic Safety
Certificate: Baseefa11ATEX0174X Standards: EN 60079-0: 2012, EN 60079-11: 2012 Markings: II 1 G Ex ia IIC T4 Ga, T4 (–40 °C T
+70 °C)
a
The US National Electrical Code® (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes.
8
Special Conditions for Safe Use (X):
1. The plastic enclosure of the Rosemount 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
2. The Model 701PGNKF Power Module may be replaced in a hazardous area. The power module has a surface resistivity greater than 1GΩ and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.
Emerson.com/Rosemount
Page 9
February 2017
Rosemount 708

International

I7 IECEx Intrinsic Safety
Certificate: IECEx BAS 11.0091X Standards: IEC 60079-0:2011, IEC 60079-11:2011 Markings: Ex ia IIC T4 Ga, T4(–40 °C ≤ T
Special Condition for Safe Use (X):
1. The plastic enclosure of the Rosemount 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
+70 °C)
a

Brazil

I2 INMETRO Intrinsic Safety
Certificate: UL-BR 16.0128X Standards: ABNT NBR IEC 60079-0:2008 + Errata 1:2011,
ABNT NBR IEC 60079-11:2009
Markings: Ex ia IIC T4 Ga, T4(–40 °C ≤ T
Special Condition for Safe Use (X):
1. See certificate for special conditions.
+70 °C)
a

China

I3 China Intrinsic Safety
Certificate: GYJ13.1445X Standards: GB3836.1-2010, GB3836.4-2010,
GB3836.20-2010
Markings: Ex ia IIC Ga T4,–40
~ +70 °C

Japan

I4 TIIS Intrinsically Safe
Certificate: TC20395 Markings: Ex ia IIC T4 X (–20 ~ +60 °C)

EAC - Belarus, Kazakhstan, Russia

IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.Gb05.B.00643 Markings: 0Ex ia IIC T4 Ga X
T4 (–40 °C ≤ T
Special Condition for Safe Use (X):
1. See certificate for special conditions.
+70 °C)
a

Korea

IP Korea Intrinsic Safety
Certificate: 13-KB4BO-0145X Markings: Ex ia IIC T4
T4 (–40 °C ≤ T
Special Condition for Safe Use (X):
1. See certificate for special conditions.
+70 °C)
a
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Emerson.com/Rosemount
9
Page 10
Rosemount 708
4.29
(109.0)
Ø2.22
(56.38)
2.00
(50.8)
3.97
(100.8)
4.25
(108.0)
Ø3.68
(93.47)
5.35
(135.89)
3.13
(79.50)
1.95
(49.5)
A
B
3.80 (97)
1.81 (46)
6.86
(174)
.78
(20)

Dimensional Drawings

Figure 1. Rosemount 708 Direct Mount
February 2017
Dimensions are in inches (millimeters).
Figure 2. Rosemount 708 Acoustic Transmitter with High Temperature Standoff and Fastener Kit
A. For nominal pipe sizes 0.5- to 11/4-in. B. Bracket mounting Dimensions are in inches (millimeters).
10
Emerson.com/Rosemount
Page 11
February 2017
Rosemount 708
Emerson.com/Rosemount
11
Page 12
Rosemount 708
00813-0100-4708, Rev BD
Global Headquarters
Emerson Automation Solutions
6021 Innovation Blvd. Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@Emerson.com
North America Regional Office
Emerson Automation Solutions
8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com
Latin America Regional Office
Emerson Automation Solutions
1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA
+1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@Emerson.com
Product Data Sheet
February 2017
Europe Regional Office
Emerson Automation Solutions Europe GmbH
Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@Emerson.com
Asia Pacific Regional Office
Emerson Automation Solutions Asia Pacific Pte Ltd
1 Pandan Crescent Singapore 128461
+65 6777 8211 +65 6777 0947 Enquiries@AP.Emerson.com
Middle East and Africa Regional Office
Emerson Automation Solutions
Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
+971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Google.com/+RosemountMeasurement
Standard Terms and Conditions of Sale can be found on the Ter ms a nd
Conditions of Sale page.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Ovation, SmartPower, SteamLogic, DeltaV, Rosemount, and Rosemount logotype are trademarks of Emerson. WirelessHART is a registered trademark of the FieldComm Group. Modbus is a registered trademark of Gould Inc. NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association. National Electrical Code is a registered trademark of National Fire Protection Association, Inc. All other marks are the property of their respective owners.
© 2017 Emerson. All rights reserved.