An installation-ready solution that provides simple connection to a turbine meter or a pulse output device
Measure average flow and totalized volume
Flow and volume are continuously measured between wireless updates
Self-organizing network delivers information rich data with greater than 99 percent data reliability
Page 2
Rosemount 705 Wireless Totalizing Transmitter
Emerson™ Wireless solutions
September 2017
IEC 62591 (WirelessHART®)... The
industry standard
Self-organizing, adaptive mesh routing
No wireless expertise required, network automatically finds
the best communication paths
The self-organizing, self-healing network manages multiple
communication paths for any given device. If an obstruction is
introduced into the network, data will continue to flow
because the device already has other established paths. The
network will then lay in more communication paths as needed
for that device.
Emerson’s Wireless
Reliable wireless architecture
Standard IEEE 802.15.4 radios
2.4 GHz ISM band sliced into 15 radio-channels
Time Synchronized Channel Hopping to avoid interference
from other radios, Wi-Fi, and EMC sources and increase
reliability
Direct sequence spread spectrum (DSSS) technology delivers
Table 1. Rosemount 705 Wireless Totalizing Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Omni directional wireless antenna and SmartPower solutions
WK1External antenna, adapter for black power module (I.S. Power module sold separately)★
(1)
WM1Extended range, external antenna, adapter for black power module (I.S. Power module sold separately)★
WJ1Remote antenna, adapter for black power module (I.S.Power module sold separately)
(2)
WN1
High-gain, remote antenna, adapter for black power module (I.S. Power module sold separately)
Emerson.com/Rosemount
3
Page 4
Rosemount 705 Wireless Totalizing Transmitter
Table 1. Rosemount 705 Wireless Totalizing Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
September 2017
Other options (Include with selected model number)
Display
M5LCD display★
Mounting bracket
B4Universal L mounting bracket for 2-in. pipe mounting - SST bracket and bolts★
Typical model number: 705 X D1 D 1 I6 WA3 WM1 M5 C1
1.Black Power Module must be shipped separately, order model 701PBKKF or part number 00753-9220-0001.
2.Limited availability, consult factory for details.
Spare parts and accessories
Table 2. Spare Parts and Accessories
Spare parts and accessories
00705-9000-0001Cable is only 9-in. long
00705-9000-0002Cable assembly, 10 ft. long for remote mount option
03151-9270-0003Remote housing bracket kit
701PBKKFBlack power module
★
4
Emerson.com/Rosemount
Page 5
September 2017
Specifications
Rosemount 705 Wireless Totalizing Transmitter
Functional specifications
Wireless output
IEC 62591 (WirelessHART) 2.4 GHz DSSS
Radio frequency power output from antenna
External (WK option) antenna:
Maximum of 10 mW (10 dBm) EIRP
Extended range, External (WM option) antenna:
Maximum of 18 mW (12.5 dBm) EIRP
High Gain, Remote (WN option) antenna:
Maximum of 40 mW (16 dBm) EIRP
Remote (WJ option) antenna:
Maximum of 17 mW (12.3 dBm) EIRP
Local display
The optional integral LCD can display totalized volume, average
flow rate, and diagnostic information. Display refresh at each
wireless update, option to have the display always on.
Humidity limits
0–99 percent relative humidity
Wireless update rate
User selectable, one second to 60 minutes
Flow rate accuracy
Flow rate accurate of better than ±0.01 percent of reading at
reference conditions
pickup).
(1)
(excluding turbine meter and magnetic
Physical specifications
Electrical connections
Wireless power module
Replaceable, intrinsically safe lithium-thionyl chloride power
module with PBT polymer enclosure. Ten year life at reference
condition
Wiring terminals
Screw terminals fixed to terminal block
Field Communicator connections
Communication terminals clips permanently fixed to terminal
block.
Totalization accurate of better than ±0.01 percent of reading at
reference conditions
pickup).
1.Reference conditions are 70 °F (21 °C), for frequency 170Hz to 10khz.
Emerson.com/Rosemount
(1)
(excluding turbine meter and magnetic
Low-copper aluminum:
705 without LCD display - 4.6 lb (2.0 kg)
705 with M5 LCD display - 4.7 lb (2.1 kg)
Stainless steel:
705 without LCD display - 8.0 lb (3.6 kg)
705 with M5 LCD display - 8.1 lb (3.7 kg)
Enclosure ratings
NEMA® 4X and IP66/67
Mounting
Transmitters may be attached directly to pulse output device or
turbine meters. Brackets also permit remote mounting. See
“Dimensional drawings” on page 10.
2.Continuous exposure to ambient temperature limits (-40 °F or 185 °F)
(–40 °C or 85 °C) may reduce specified power module life by less than 20
percent and routing data for three additional network devices.
5
Page 6
Rosemount 705 Wireless Totalizing Transmitter
Performance specifications
Electro Magnetic Compatibility (EMC)
All models
Meets all industrial environment requirements of EN61326 and
NAMUR NE-21. Maximum deviation less than 1 percent span
during EMC disturbance
Vibration effect
Wireless output unaffected when tested per the requirements of
IEC60770-1 field or pipeline with high vibration level (10–60 Hz
0.21 mm displacement peak amplitude/60–2000 Hz 3 g).
Temperature limits
DescriptionOperating limitStorage limit
(1)
.
September 2017
Without LCD display
With LCD display
–40 to 185 °F
–40 to 85 °C
–4 to 175 °F
–20 to 80 °C
–40 to 185 °F
–40 to 85 °C
–40 to 185 °F
–40 to 85 °C
Input parameter
One input channel available. The device operates at pulse inputs
from 3–10,000 Hz and at a minimum sensitivity of 10 mV and
maximum sensitivity up to 42.2 V.
Output parameter
The device will output specified average pulse (flow) rate and
total pulse accumulation (volume) by user-selected units based
on the calibration factor of the pulse input device or the k-factor.
Calibration factor or k-factor
The device requires a calibration factor that can be input via a
®
hand held, AMS Device Manager or factory inputs
HART
(requires C1 option). The k-factor is typically supplied by the
manufacturer of the pulse generation source.
1.During surge event device may exceed maximum EMC deviation limit or
reset; however, device will self-recover and return to normal operation
within specified start-up time.
6
Emerson.com/Rosemount
Page 7
September 2017
Product Certifications
Rev 1.1
Rosemount 705 Wireless Totalizing Transmitter
European Directive Information
A copy of the EC Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EC
Declaration of Conformity can be found at
Emerson.com/Rosemount
.
Telecommunication Compliance
All wireless devices require certification to ensure that they
adhere to regulations regarding the use of the RF spectrum.
Nearly every country requires this type of product certification.
Emerson is working with governmental agencies around the
world to supply fully compliant products and remove the risk of
violating country directives or laws governing wireless device
usage.
FCC and IC
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions: This device may not cause
harmful interference. This device must accept any interference
received, including interference that may cause undesired
operation. This device must be installed to ensure a minimum
antenna separation distance of 20 cm from all persons.
Ordinary Location Certification from
CSA
The transmitter has been examined and tested to determine
that the design meets the basic electrical, mechanical, and fire
protection requirements by CSA, a nationally recognized test
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).
Installing in North America
The US National Electrical Code® (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in Divisions.
The markings must be suitable for the area classification, gas,
and temperature class. This information is clearly defined in the
respective codes.
USA
I5U.S.A. Intrinsically Safe (IS)
Certificate: CSA 70011131
Standards: FM 3600 – 2011, FM 3610 – 2010,
UL Standard 50 – Eleventh Edition,
UL 61010-1 – 3
ANSI/ISA-60079-0 (12.00.01) – 2013,
ANSI/ISA-60079-11 (12.02.01) – 2013,
ANSI/IEC 60529 – 2004
Markings: IS CL I, DIV 1, GP A, B, C, D T4; Class 1, Zone 0,
AEx ia IIC T4 Ga; T4 (–50 °C ≤ T
installed per Rosemount drawing 00705-1020;
Type 4X; IP66
See the table at the end of this section for entity
parameters.
N5 U.S.A. Division 2, Nonincendive
Certificate: CSA 70011131
Standards: FM 3600 – 2011, FM 3611 – 2004,
UL Standard 50 – Eleventh Edition,
UL 61010-1 (3
ANSI/IEC 60529 – 2004
Markings: NI CL I, DIV 2, GP A, B, C, D T4;
T4 (–50 °C ≤ T
Type 4X; IP66
Special Conditions for Safe Use (X):
1. For use only with the Model 701P or Rosemount P/N
753-9220-XXXX Smart Power Battery Module.
2. The surface resistivity of the antenna is greater than 1 GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
Groups A, B, C, D T4;
T4 (–50 °C ≤ T
Type 4X; IP66
Special Conditions for Safe Use (X):
1. For use only with the Model 701P or Rosemount P/N
753-9220-XXXX Smart Power Battery Module.
2. The surface resistivity of the antenna is greater than 1 GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
≤ +70 °C);
a
Europe
I1ATEX Intrinsic Safety
Certificate: Baseefa14ATEX0375X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings: II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ T
For use with Rosemount SmartPower power module part
number 753-9220-0001, or for use with Emerson
SmartPower option 701PBKKF.
See the table at the end of this section for entity
parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a
hazardous area. The Power Modules have a surface
resistivity greater than 1 GΩ and must be properly
installed I the wireless device enclosure. Care must be
taken during transportation to and from the point of
installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and
given a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion if
located in a Zone 0 area.
IUATEX Intrinsic Safety for Zone 2
Certificate: Baseefa15ATEX0059X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings: II 3 G Ex ic IIC T4 Gc, T4(-60 °C ≤ T
For use with Rosemount SmartPower power module part
number 753-9220-0001, or for use with Emerson
SmartPower option 701PBKKF.
See the table at the end of this section for entity
parameters.
≤ +70 °C)
a
≤ +70 °C)
a
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a
hazardous area. The Power Modules have a surface
resistivity greater than 1 GΩ and must be properly
installed I the wireless device enclosure. Care must be
taken during transportation to and from the point of
installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and
given a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion if
located in a Zone 0 area.
International
I7IECEx Intrinsic Safety
Certificate: IECEx BAS 14.0173X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4 (–60 °C ≤ T
For use with Rosemount SmartPower power module part
number 753-9220-0001, or for use with Emerson
SmartPower option 701PBKKF.
See the table at the end of this section for entity
parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a
hazardous area. The Power Modules have a surface
resistivity greater than 1 GΩ and must be properly
installed I the wireless device enclosure. Care must be
taken during transportation to and from the point of
installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and
given a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion if
located in a Zone 0 area.
IYIECEx Intrinsic Safety for Zone 2
Certificate: IECEx BAS 14.0173X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ic IIC T4 Gc, T4 (–60 °C ≤ T
For use with Rosemount SmartPower power module part
number 753-9220-0001, or for use with Emerson
SmartPower option 701PBKKF.
See the table at the end of this section for entity
parameters.
≤ +70 °C)
a
≤ +70 °C)
a
8
Emerson.com/Rosemount
Page 9
September 2017
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ.
To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a
hazardous area. The Power Modules have a surface
resistivity greater than 1 GΩ and must be properly
installed I the wireless device enclosure. Care must be
taken during transportation to and from the point of
installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and
given a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion if
located in a Zone 0 area.
Standard Terms and Conditions of Sale can be found on the Ter ms a nd
Conditions of Sale page.
The Emerson logo is a trademark and service mark of Emerson Electric
Co.
SmartPower, Rosemount, and Rosemount logotype are trademarks of
Emerson.
HART and WirelessHART are registered trademarks of FieldComm Group.
NEMA is a registered trademark and service mark of the National
Electrical Manufacturers Association.
National Electrical Code is a registered trademark of National Fire
ProtectionAssociation, Inc.
All other marks are the property of their respective owners.