Rosemount 705 Specifications

Page 1
00813-0200-4705, Rev BA
Rosemount™ 705 Wireless Totalizing Transmitter
Product Data Sheet
September 2017
An installation-ready solution that provides simple connection to a turbine meter or a pulse output device
Measure average flow and totalized volume
Flow and volume are continuously measured between wireless updates
Self-organizing network delivers information rich data with greater than 99 percent data reliability
Page 2
Rosemount 705 Wireless Totalizing Transmitter

Emerson™ Wireless solutions

September 2017

IEC 62591 (WirelessHART®)... The industry standard

Self-organizing, adaptive mesh routing
No wireless expertise required, network automatically finds
the best communication paths
The self-organizing, self-healing network manages multiple
communication paths for any given device. If an obstruction is introduced into the network, data will continue to flow because the device already has other established paths. The network will then lay in more communication paths as needed for that device.

Emerson’s Wireless

Reliable wireless architecture
Standard IEEE 802.15.4 radios
2.4 GHz ISM band sliced into 15 radio-channels
Time Synchronized Channel Hopping to avoid interference
from other radios, Wi-Fi, and EMC sources and increase reliability
Direct sequence spread spectrum (DSSS) technology delivers
high reliability in challenging radio environment
Contents
Emerson™ Wireless solutions . . . . . . . . . . . . . . . . . . . . . . . 2
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SmartPower™ solutions
Optimized Emerson instrumentation, both hardware and
software, to extend power module life
Intrinsically safe power module allows field replacements
without removing the transmitter from the process, keeping personnel safe, and reducing maintenance costs
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2
Emerson.com/Rosemount
Page 3
September 2017
Rosemount 705 Wireless Totalizing Transmitter

Ordering Information

Table 1. Rosemount 705 Wireless Totalizing Transmitter Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Product description
705 Totalizing Transmitter (with connector mil-c-5015)
Transmitter outpu t
X Wireless
Transmitter type
D1 Direct mount
R1 Remote mount (10 ft. leads included)
Housing
D Dual compartment housing - aluminum
E Dual compartment housing - SST
Conduit threads
1
1
/2–14 NPT
Certifications
I5 U.S.A Intrinsically Safe
I6 Canada Intrinsically Safe
N5 U.S.A. Division 2, Non-incendive
N6 Canada Division 2, Non-incendive
I1 ATEX Intrinsic Safety
IU ATEX Intrinsic Safety for Zone 2
I7 IECEx Intrinsic Safety
IY IECEx Intrinsic Safety for Zone 2
Wireless options
Wireless update rate, operating frequency and protocol
WA3 User configurable update rate, 2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omni directional wireless antenna and SmartPower solutions
WK1 External antenna, adapter for black power module (I.S. Power module sold separately)
(1)
WM1 Extended range, external antenna, adapter for black power module (I.S. Power module sold separately)
WJ1 Remote antenna, adapter for black power module (I.S.Power module sold separately)
(2)
WN1
High-gain, remote antenna, adapter for black power module (I.S. Power module sold separately)
Emerson.com/Rosemount
3
Page 4
Rosemount 705 Wireless Totalizing Transmitter
Table 1. Rosemount 705 Wireless Totalizing Transmitter Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
September 2017
Other options (Include with selected model number)
Display
M5 LCD display
Mounting bracket
B4 Universal L mounting bracket for 2-in. pipe mounting - SST bracket and bolts
Configuration
C1
Calibration factor (k-factor) configuration (factory configure date, descriptor, message fields, and wireless parameters)
Typical model number: 705 X D1 D 1 I6 WA3 WM1 M5 C1
1. Black Power Module must be shipped separately, order model 701PBKKF or part number 00753-9220-0001.
2. Limited availability, consult factory for details.

Spare parts and accessories

Table 2. Spare Parts and Accessories
Spare parts and accessories
00705-9000-0001 Cable is only 9-in. long
00705-9000-0002 Cable assembly, 10 ft. long for remote mount option
03151-9270-0003 Remote housing bracket kit
701PBKKF Black power module
4
Emerson.com/Rosemount
Page 5
September 2017

Specifications

Rosemount 705 Wireless Totalizing Transmitter

Functional specifications

Wireless output
IEC 62591 (WirelessHART) 2.4 GHz DSSS
Radio frequency power output from antenna
External (WK option) antenna: Maximum of 10 mW (10 dBm) EIRP
Extended range, External (WM option) antenna: Maximum of 18 mW (12.5 dBm) EIRP
High Gain, Remote (WN option) antenna: Maximum of 40 mW (16 dBm) EIRP
Remote (WJ option) antenna: Maximum of 17 mW (12.3 dBm) EIRP
Local display
The optional integral LCD can display totalized volume, average flow rate, and diagnostic information. Display refresh at each wireless update, option to have the display always on.
Humidity limits
0–99 percent relative humidity
Wireless update rate
User selectable, one second to 60 minutes
Flow rate accuracy
Flow rate accurate of better than ±0.01 percent of reading at reference conditions pickup).
(1)
(excluding turbine meter and magnetic

Physical specifications

Electrical connections
Wireless power module
Replaceable, intrinsically safe lithium-thionyl chloride power module with PBT polymer enclosure. Ten year life at reference condition
Wiring terminals
Screw terminals fixed to terminal block
Field Communicator connections
Communication terminals clips permanently fixed to terminal block.
Materials of construction
Enclosure
Housing: Low-copper aluminum, or stainless steel Paint: Polyurethane Cover O-ring: Buna-N
Terminal block
PBT
Antenna
PBT/PC integrated omni directional antenna
Conduit entries
1
/2–14 NPT
Weight
(2)
.
Totalization accuracy
Totalization accurate of better than ±0.01 percent of reading at reference conditions pickup).
1. Reference conditions are 70 °F (21 °C), for frequency 170Hz to 10khz.
Emerson.com/Rosemount
(1)
(excluding turbine meter and magnetic
Low-copper aluminum: 705 without LCD display - 4.6 lb (2.0 kg) 705 with M5 LCD display - 4.7 lb (2.1 kg)
Stainless steel: 705 without LCD display - 8.0 lb (3.6 kg) 705 with M5 LCD display - 8.1 lb (3.7 kg)
Enclosure ratings
NEMA® 4X and IP66/67
Mounting
Transmitters may be attached directly to pulse output device or turbine meters. Brackets also permit remote mounting. See
“Dimensional drawings” on page 10.
2. Continuous exposure to ambient temperature limits (-40 °F or 185 °F) (–40 °C or 85 °C) may reduce specified power module life by less than 20 percent and routing data for three additional network devices.
5
Page 6
Rosemount 705 Wireless Totalizing Transmitter

Performance specifications

Electro Magnetic Compatibility (EMC)
All models
Meets all industrial environment requirements of EN61326 and NAMUR NE-21. Maximum deviation less than 1 percent span during EMC disturbance
Vibration effect
Wireless output unaffected when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10–60 Hz
0.21 mm displacement peak amplitude/60–2000 Hz 3 g).
Temperature limits
Description Operating limit Storage limit
(1)
.
September 2017
Without LCD display
With LCD display
–40 to 185 °F
–40 to 85 °C
–4 to 175 °F –20 to 80 °C
–40 to 185 °F
–40 to 85 °C
–40 to 185 °F
–40 to 85 °C
Input parameter
One input channel available. The device operates at pulse inputs from 3–10,000 Hz and at a minimum sensitivity of 10 mV and maximum sensitivity up to 42.2 V.
Output parameter
The device will output specified average pulse (flow) rate and total pulse accumulation (volume) by user-selected units based on the calibration factor of the pulse input device or the k-factor.
Calibration factor or k-factor
The device requires a calibration factor that can be input via a
®
hand held, AMS Device Manager or factory inputs
HART (requires C1 option). The k-factor is typically supplied by the manufacturer of the pulse generation source.
1. During surge event device may exceed maximum EMC deviation limit or reset; however, device will self-recover and return to normal operation within specified start-up time.
6
Emerson.com/Rosemount
Page 7
September 2017

Product Certifications

Rev 1.1
Rosemount 705 Wireless Totalizing Transmitter

European Directive Information

A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EC Declaration of Conformity can be found at
Emerson.com/Rosemount
.

Telecommunication Compliance

All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification.
Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.

FCC and IC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons.

Ordinary Location Certification from CSA

The transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by CSA, a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

Installing in North America

The US National Electrical Code® (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes.
USA
I5 U.S.A. Intrinsically Safe (IS)
Certificate: CSA 70011131 Standards: FM 3600 – 2011, FM 3610 – 2010,
UL Standard 50 – Eleventh Edition, UL 61010-1 – 3 ANSI/ISA-60079-0 (12.00.01) – 2013, ANSI/ISA-60079-11 (12.02.01) – 2013, ANSI/IEC 60529 – 2004
Markings: IS CL I, DIV 1, GP A, B, C, D T4; Class 1, Zone 0,
AEx ia IIC T4 Ga; T4 (–50 °C ≤ T installed per Rosemount drawing 00705-1020; Type 4X; IP66
See the table at the end of this section for entity parameters.
N5 U.S.A. Division 2, Nonincendive
Certificate: CSA 70011131 Standards: FM 3600 – 2011, FM 3611 – 2004,
UL Standard 50 – Eleventh Edition, UL 61010-1 (3 ANSI/IEC 60529 – 2004
Markings: NI CL I, DIV 2, GP A, B, C, D T4;
T4 (–50 °C ≤ T Type 4X; IP66
Special Conditions for Safe Use (X):
1. For use only with the Model 701P or Rosemount P/N 753-9220-XXXX Smart Power Battery Module.
2. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
rd
Edition,
rd
Edition),
+70 °C);
a
+70 °C) when
a
Canada
I6 Canada Intrinsically Safe (IS)
Certificate: CSA 70011131 Standards: CAN/CSA C22.2 No. 0-10,
CAN/CSA C22.2 No. 94-M91, CSA Std C22.2 No.142-M1987, CAN/CSA-60079-0 - 2011, CAN/CSA-60079-11 - 2014, CSA Std C22.2 No. 60529 - 2005, CAN/CSA-C22.2 No. 61010-1 - 2012
Markings: IS CL I, DIV 1, GP A, B, C, D T4;
Ex ia IIC T4 Ga, T4; T4 (-50 °C ≤ T when installed per Rosemount drawing 00705-1020; Type 4X; IP66
See the table at the end of this section for entity parameters.
+70 °C)
a
Emerson.com/Rosemount
7
Page 8
Rosemount 705 Wireless Totalizing Transmitter
September 2017
N6 Canada Division 2, Nonincendive
Certificate: CSA 70011131 Standards: CAN/CSA C22.2 No. 0-10,
CAN/CSA C22.2 No. 94-M91, CSA Std C22.2 No. 213-M1987 (R2013), CAN/CSA-60079-0 - 2011, CAN/CSA Std C22.2 No. 60529 - 2005, CAN/CSA-C22.2 No. 61010-1 - 2012
Markings: Suitable for Class 1, Division 2,
Groups A, B, C, D T4; T4 (–50 °C ≤ T Type 4X; IP66
Special Conditions for Safe Use (X):
1. For use only with the Model 701P or Rosemount P/N 753-9220-XXXX Smart Power Battery Module.
2. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
+70 °C);
a
Europe
I1 ATEX Intrinsic Safety
Certificate: Baseefa14ATEX0375X Standards: EN 60079-0: 2012, EN 60079-11: 2012 Markings: II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ T
For use with Rosemount SmartPower power module part number 753-9220-0001, or for use with Emerson SmartPower option 701PBKKF.
See the table at the end of this section for entity parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a hazardous area. The Power Modules have a surface resistivity greater than 1 GΩ and must be properly installed I the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 area.
IU ATEX Intrinsic Safety for Zone 2
Certificate: Baseefa15ATEX0059X Standards: EN 60079-0: 2012, EN 60079-11: 2012 Markings: II 3 G Ex ic IIC T4 Gc, T4(-60 °C ≤ T
For use with Rosemount SmartPower power module part number 753-9220-0001, or for use with Emerson SmartPower option 701PBKKF.
See the table at the end of this section for entity parameters.
+70 °C)
a
+70 °C)
a
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a hazardous area. The Power Modules have a surface resistivity greater than 1 GΩ and must be properly installed I the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 area.
International
I7 IECEx Intrinsic Safety
Certificate: IECEx BAS 14.0173X Standards: IEC 60079-0: 2011, IEC 60079-11: 2011 Markings: Ex ia IIC T4 Ga, T4 (–60 °C ≤ T
For use with Rosemount SmartPower power module part number 753-9220-0001, or for use with Emerson SmartPower option 701PBKKF.
See the table at the end of this section for entity parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a hazardous area. The Power Modules have a surface resistivity greater than 1 GΩ and must be properly installed I the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 area.
IY IECEx Intrinsic Safety for Zone 2
Certificate: IECEx BAS 14.0173X Standards: IEC 60079-0: 2011, IEC 60079-11: 2011 Markings: Ex ic IIC T4 Gc, T4 (–60 °C ≤ T
For use with Rosemount SmartPower power module part number 753-9220-0001, or for use with Emerson SmartPower option 701PBKKF.
See the table at the end of this section for entity parameters.
+70 °C)
a
+70 °C)
a
8
Emerson.com/Rosemount
Page 9
September 2017
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a hazardous area. The Power Modules have a surface resistivity greater than 1 GΩ and must be properly installed I the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.
3. The 705 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 area.
4.
Brazil
I2 INMETRO Intrinsic Safety
Certificate: UL-BR 17.0019X Standards: ABNT NBR IEC 60079-0:2008 + Errata 1:2011,
ABNT NBR IEC 60079-11:2009
Markings: Ex ia IIC T4 Ga, T4 (–60 °C ≤ T
table at the end of this section for entity parameters.
+70 °C); See the
a
Rosemount 705 Wireless Totalizing Transmitter
Special Condition for Safe Use (X):
1. See certificate for special conditions.
EAC - Belarus, Kazakhstan, Russia
IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: TC RU C-US.MIO62.B.03122
max/Ui
max/Ii
max/Pi
+70 °C);
a
= 10 V
= 1 mA
= 1 mW
Markings: 0Ex ia IIC T4 Ga X, T4 (–60 °C ≤ T
See the table at the end of this section for entity
parameters.
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Turbine meter terminal
Turbine meter terminal
output parameters
Voc/Uo = 2.5 V V
Isc/Io = 253 μA I
P
= 640 μW P
max/Po
Ca/Co = 2.9 μF Ci = 2.2 nF
La/Lo= 500 mH Li = 4.7 mH
input parameters
Emerson.com/Rosemount
9
Page 10
Rosemount 705 Wireless Totalizing Transmitter
1.50 [38]
A
D
B
C
2.49 [63]
4.20 [107]
7.81 [198]
11.16 [284]
E
7.88 [200]
F
0.42 [11]
6.05 [154]

Dimensional drawings

Figure 1. Rosemount 705 Transmitter
Shown with 2.4 GHz/extended range antenna
September 2017
Shown with optional digital display
and 2.4 GHz/antenna
A. 2.4 GHz/extended range antenna B. 1-in. NPT connection to flow meter C. Ground screw assembly
Dimensions are in inches (millimeters).
Shown without optional digital display
D. Possible antenna rotation E. Digital display cover F. Tr an sm itter ele ct ro nic s
10
Emerson.com/Rosemount
Page 11
September 2017
D
1.03 [26]
4.03 [102]
C
1.38[35]
B
A
Rosemount 705 Wireless Totalizing Transmitter
Figure 2. Rosemount 705 Transmitter Mounting Configurations with Optional Mounting Bracket
A. Pipe mounting B. 2-in. U-bolt for pipe mounting C. Ground screw assembly
Dimensions are in inches (millimeters).
D.1-in. NPT connection to flow meter E. Turbine meter connection
Emerson.com/Rosemount
11
Page 12
Rosemount 705 Wireless Totalizing Transmitter
00813-0200-4705, Rev BA
Global Headquarters
Emerson Automation Solutions
6021 Innovation Blvd. Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@Emerson.com
North America Regional Office
Emerson Automation Solutions
8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com
Latin America Regional Office
Emerson Automation Solutions
1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA
+1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@Emerson.com
Product Data Sheet
September 2017
Europe Regional Office
Emerson Automation Solutions Europe GmbH
Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@Emerson.com
Asia Pacific Regional Office
Emerson Automation Solutions Asia Pacific Pte Ltd
1 Pandan Crescent Singapore 128461
+65 6777 8211 +65 6777 0947 Enquiries@AP.Emerson.com
Middle East and Africa Regional Office
Emerson Automation Solutions
Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
+971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Google.com/+RosemountMeasurement
Standard Terms and Conditions of Sale can be found on the Ter ms a nd
Conditions of Sale page.
The Emerson logo is a trademark and service mark of Emerson Electric Co. SmartPower, Rosemount, and Rosemount logotype are trademarks of Emerson. HART and WirelessHART are registered trademarks of FieldComm Group. NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association. National Electrical Code is a registered trademark of National Fire ProtectionAssociation, Inc. All other marks are the property of their respective owners.
© 2017 Emerson. All rights reserved.
Loading...